Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Transient aerodynamic forces on a fighter model during simulated approach and landing with thrust reversers

Previous wind tunnel tests of fighter configurations have shown that thrust reverser jets can induce large, unsteady aerodynamic forces and moments during operation in ground proximity. This is a concern for STOL configurations using partial reversing to spoil the thrust while keeping the engine output near military (MIL) power during landing approach. A novel test technique to simulate approach and landing was developed under a cooperative Northrop/NASA/USAF program. The NASA LaRC Vortex Research Facility was used for the experiments in which a 7-percent F-18 model was moved horizontally at speeds of up to 100 feet per second over a ramp simulating an aircraft to ground rate of closure similar to a no-flare STOL approach and landing. This paper presents an analysis of data showing the effect of reverser jet orientation and jet dynamic pressure ratio on the transient forces for different angles of attack, and flap and horizontal tail deflection. It was found, for reverser jets acting parallel to the plane of symmetry, that the jets interacted strongly with the ground, starting approximately half a span above the ground board. Unsteady rolling moment transients, large enough to cause the probable upset of an aircraft, and strong normal force and pitching moment transients were measured. For jets directed 40 degrees outboard, the transients were similar to the jet-off case, implying only minor interaction.

Humphreys, A. P.↗

Numerical analysis of pulse facility transient flow through a supersonic combustion model

The supersonic high enthalpy flow from a shock tunnel facility flowing through a two-dimensional duct simulating a combustor has been computed for two test conditions for both steady and transient inflow. The nominal test conditions had stagnation enthalpies of 4.3 and 12.1 MJ/kg, with corresponding flight Mach numbers of 9 and 16, respectively. A full Navier-Stokes code (SPARK) was used to compute the flow development and the mixing of a hydrogen jet injected from the base of a central strut. Results of the calculations are presented and compared with wall pressure data. Additional comparisons of the transient and steady inflow results are presented to assess the effect of transient flow on the data. This paper presents a status of the progress in applying CFD codes to analyze the transient flow from a pulse facility.

Rogers, R. Clayton↗

High-resolution heat-transfer-coefficient maps applicable to compound-curve surfaces using liquid crystals in a transient wind tunnel

Tests were performed in a transient heat transfer tunnel in which the model under test was preheated prior to allowing room temperature air to be suddenly drawn over the model. The resulting movement of isothermal contours on the model is revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record is obtained of a temperature and time data pair for all points on the model during a single test. Experiments on a duct model are reported in which the model was preheated using a hot air stream. A manner in which initial model temperature nonuniformities could be taken into account was investigated. The duct model was also tested with a steady-state measurement technique and results were compared with the transient measurements, but recognizing that differences existed between the upstream thermal boundary conditions. The steady-state and transient measurements were shown to be consistent with predicted values. The main advantage of this transient heat transfer technique using liquid crystals is that since the test model need not be actively heated, high-resolution measurements on surfaces with complex shapes may be obtained.

Jones, Terry V.↗

Deep-level transient spectroscopy of Al(x)Ga(1-x)As/GaAs using nondestructive acousto-electric voltage measurement

The amplitude and the transient time constant of the acoustoelectric voltage were measured as a function of temperature to determine the activation energy of deep levels in Al(x)Ga(1-x)As/GaAs grown by molecular-beam epitaxy. In comparison to other methods based on monitoring the capacitance transient, deep-level transient spectroscopy has several advantages. The technique is nondestructive and highly sensitive, and, because of the dependence of the polarity of the acoustoelectric voltage on the carrier type, it yields information about the charge of the transient carriers and the type of deep traps involved in the release or trapping of these carriers.

Tabib-Azar, Massood↗

Some aspects of transient cooling of a radiating rectangular medium

The emission from a gray radiating medium is analyzed for transient cooling in surroundings at a low temperature. The medium is rectangular with no variations in the direction normal to the cross section. The integral equation for the transient temperature distribution is solved numerically using a two-dimensional Gaussian integration subroutine. The emissive ability for a rectangle at uniform temperature is compared with that for transient cooling where the temperature distribution of the region has reached a fully developed shape, as shown by a separation of variables solution. The two solutions provide the upper and lower bounds for the emittance of a rectangle during transient cooling. The emittances for various aspect ratios are presented as a function of the mean length of the rectangle and are compared with results for a plane layer and a cylinder.

Siegel, Robert↗

Numerical investigation of the transient SSME fuel preburner combustor flowfield

A computational fluid dynamics (CFD) model with finite-rate reactions, FDNS2DR, has been developed to study the start transient of the Space Shuttle Main Engine Fuel Preburner (FPB) operation. This design tool can predict accurately the severe thermal gradients which are impressed upon the fuel preburner and turbine during the start transient. An axisymmetric configuration with a grid size of 68 x 45 is used to represent the FPB flowfield. The transient upstream boundary conditions are obtained from a one-dimensional Digital Transient Model simulation to better represent the actual operation. The results of the CFD calculation show temperature spikes near the FPB exit whose timing and magnitude agree well with those of the measured turbine inlet temperature data.

Wang, Ten-See↗

Emittance bounds for transient radiative cooling of a scattering rectangular region

Transient cooling was analyzed for a two-dimensional gray rectangular region that emits, absorbs, and isotropically scatters radiation. The region, initially at uniform temperature, is placed in surroundings at a much lower temperature. The cooling analysis yields two simultaneous equations for the transient temperature and scattering source function distributions. The region starts to cool with the medium at uniform temperature. For this condition, the local emittance around the perimeter was obtained by a numerical solution of the radiative equations, and the rate of heat loss from the entire medium was evaluated. As cooling continues, the emissive ability decreases because of the lower temperatures in the outer regions of the rectangle. Based on some previous work, a lower limit for the transient overall emittance was found by obtaining a similarity solution. For some ranges of optical thickness and scattering albedo, the lower limit is only a small amount below the initial emittance. For these conditions, the initial emittance can be used to compute the entire transient resulting in a considerable simplification.

Siegel, Robert↗

Transient loads analysis for space flight applications

A significant part of the flight readiness verification process involves transient analysis of the coupled Shuttle-payload system to determine the low frequency transient loads. This paper describes a methodology for transient loads analysis and its implementation for the Spacelab Life Sciences Mission. The analysis is carried out using two major software tools - NASTRAN and an external FORTRAN code called EZTRAN. This approach is adopted to overcome some of the limitations of NASTRAN's standard transient analysis capabilities. The method uses Data Recovery Matrices (DRM) to improve computational efficiency. The mode acceleration method is fully implemented in the DRM formulation to recover accurate displacements, stresses, and forces. The advantages of the method are demonstrated through a numerical example.

Thampi, S. K.↗

Transient cooling of a square region of radiating medium

A time-accurate numerical solution was carried out for transient radiative cooling of a gray emitting and absorbing medium in a square two-dimensional region. The integro-differential energy equation for transient temperature distributions was solved in two stages. At each time increment, the local radiative source term was obtained by numerical integration of the temperature field using two-dimensional Gaussian integration over rectangular subregions. Then the differential portion of the equation was integrated forward in time by use of the local first and second time derivatives. The results were compared with available limiting case, and excellent agreement was obtained. Transient results are given for a wide range of optical thicknesses of the region. Optimum transient cooling is obtained when the optical side length is about 4.

Siegel, Robert↗

Transient liquid-crystal technique used to produce high-resolution convective heat-transfer-coefficient maps

In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.

Hippensteele, Steven A.↗

Giant transient decreases of cosmic rays in the outer heliosphere in September 1991

Large transient decreases over 20 percent were observed above 70 MeV cosmic ray intensity in September 1991, at the three spacecraft, V1, V2, and P10, in the outer heliosphere between 35 and 53 AU. These decreases appear to be related to the intense solar activity occurring in late May and early June, which was responsible for a series of rapid transient decreases at the earth that probably reduced the over 70-MeV intensity by more than 50 percent to the 1owest level ever recorded. Average transit speeds of about 600 to 800 km/s are deduced for the propagation of these transients between the earth and the outer heliosphere. The overall picture of the propagation of these transients is consistent with a massive, almost spherical modulating region moving outward in the heliosphere. The smooth almost exponential recovery of intensities at all three spacecraft for over 160 days after the decrease, and the large total modulation beyond P10 at the time of the decrease, suggest that the modulation boundary is well beyond 53 AU and probably beyond 100 AU.

Webber, W. R.↗

2D axisymmetric analysis of SRM ignition transient

To analyze ignition transient of Space Shuttle solid rocket motor, a transient two-dimensional numerical model based on turbulent compressible Navier-Stokes equations in a generalized coordinate system was developed. One-dimensional numerical models (Peretz et al., 1973; Han, 1992; Pardue and Han, 1992) with empirical correlations data obtained from steady turbulent boundary layer flows agrees reasonably well with test rocket data by adjusting a few parameters. However, a 1D model can not provide a physical insight into the complex multidimensional thermal fields and flowfields in the chamber and the converging-diverging rocket nozzle. As an interim step, a 2D model was developed and compared with test data. A modified version of SIMPLE algorithm was used for the numerical model, and the standard k-epsilon model with a wall function was used for turbulence closure. Transient flowfields and thermal fields in the combustion chamber and the attached nozzle were obtained for a selected rocket geometry and propellant. Transient behaviors of the flow and thermal fields were analyzed, and were found to be in good agreement with physical expectations.

Bai, S. D.↗

Ignition Transient Calculations in the Space Shuttle Solid Rocket Motor

The work presented is part of an effort to develop a multidimensional ignition transient model for large solid propellant rocket motors. On the Space Shuttle, the ignition transient in the slot is induced when the igniter, itself a small rocket motor, is fired into the head-end portion of the main rocket motor. The computational results presented in this paper consider two different igniter configurations. The first configuration is a simulated Space Shuttle RSRM igniter which has one central nozzle that is parallel to the centerline of the motor. The second igniter configuration has a nozzle which is canted at an angle of 45 deg from the centerline of the motor. This paper presents a computational fluid dynamic (CFD) analyses of certain flow field characteristics inside the solid propellant star grain slot of the Space Shuttle during the ignition transient period of operation for each igniter configuration. The majority of studies made to date regarding ignition transient performance in solid rocket motors have concluded that the key parameter to be determined is the heat transfer rate to the propellant surface and hence the heat transfer coefficient between the gas and the propellant. In this paper the heat transfer coefficients, pressure and velocity distributions are calculated in the star slot. In order to validate the computational method and to attempt to establish a correlation between the flow field characteristics and the heat transfer rates a series of cold flow experimental investigations were conducted. The results of these experiments show excellent qualitative and quantitative agreement with the pressure and velocity distributions obtained from the CFD analysis. The CFD analysis utilized a classical pipe flow type correlation for the heat transfer rates. The experimental results provide an excellent qualitative comparison with regard to spatial distribution of the heat transfer rates as a function of nozzle configuration and igniter pressure. The results indicate that from a quantitative point of view that the pipe flow correlation gives reasonably good results. Furthermore, there appears to be a direct correlation between igniter pressure and an average Reynolds number in the star grain slot. This may lead to a simple method for modifying the convection heat transfer correlation. Calculated results of pressure-vs-time for the first 200 msec of motor firing of the Space Shuttle RSRM support the trends shown for the heat transfer rate comparisons between the cold flow CFD and experimental data.

Jenkins, Rhonald M.↗

Effects of the cooling system parameters on heat transfer and performance of the PAFC stack during transient operation

An experimental investigation for the effects of transient operation of a phosphoric acid fuel-cell stack on heat transfer and temperature distribution in the electrodes has been conducted. The proposed work utilized the experimental setup with modifications, which was designed and constructed under NASA Contract No. NCC-3-17(5). The experimental results obtained from this investigation and the mathematical model obtained under NASA Contract No. NCC3-17(4) after modifications, were utilized to develop mathematical models for transient heat transfer coefficient and temperature distribution in the electrode and to evaluate the performance of the cooling - system under unsteady state conditions. The empirical formulas developed were then implemented to modifying the developed computer code. Two incompressible coolants were used to study experimentally the effect of the thermophysical properties of the cool-ants on the transient heat transfer coefficient and the thermal contact resistance during start-up and shut-down processes. Coolant mass flow rates were verified from 16 to 88.2 Kg/hr during the transient process when the electrical power supply was gradually increased or decreased in the range (O to 3000 W/sq m). The effect of the thermal contact resistance with a range of stack pressure from O to 3500 KPa was studied.

Ridha, Rabi M. J.↗

Transient responses of phosphoric acid fuel cell power plant system

An analytical and computerized study of the steady state and transient response of a phosphoric acid fuel cell (PAFC) system was completed. Parametric studies and sensitivity analyses of the PAFC system's operation were accomplished. Four non-linear dynamic models of the fuel cell stack, reformer, shift converters, and heat exchangers were developed based on nonhomogeneous non-linear partial differential equations, which include the material, component, energy balance, and electrochemical kinetic features. Due to a lack of experimental data for the dynamic response of the components only the steady state results were compared with data from other sources, indicating reasonably good agreement. A steady state simulation of the entire system was developed using, nonlinear ordinary differential equations. The finite difference method and trial-and-error procedures were used to obtain a solution. Using the model, a PAFC system, that was developed under NASA Grant, NCC3-17, was improved through the optimization of the heat exchanger network. Three types of cooling configurations for cell plates were evaluated to obtain the best current density and temperature distributions. The steady state solutions were used as the initial conditions in the dynamic model. The transient response of a simplified PAFC system, which included all of the major components, subjected to a load change was obtained. Due to the length of the computation time for the transient response calculations, analysis on a real-time computer was not possible. A simulation of the real-time calculations was developed on a batch type computer. The transient response characteristics are needed for the optimization of the design and control of the whole PAFC system. All of the models, procedures and simulations were programmed in Fortran and run on IBM 370 computers at Cleveland State University and the NASA Lewis Research Center.

Lu, Cheng-Yi↗

SMM observations of gamma-ray transients. 3: A search for a broadened, redshifted positron annihilation line from the direction of the Galactic center

We have searched for 1980-1988 Solar Maximum Mission gamma-ray spectrometer data for transient emission on timescales from hours to approximately 12 days of broad gamma-ray lines at energies approximately 400 keV, which were reported by the High Energy Astronomy Observatory (HEAO) 1 and SIGMA experiments from two sources lying toward the Galactic center. The lines have been interpreted as the product of the annihilation of positrons in pair plasmas surrounding the black hole candidate 1E 1740.7-2942 and the X-ray binary 1H 1822-371. Our results from a combined exposure of approximately 1.5 x 10(exp 7)s provide no convincing evidence for transient emission of this line on any timescale between approximately 9 hr and approximately 1 yr. Our 3 sigma upper limits on the line flux during approximately 12 day intervals are characteristically 4.8 x 10(exp -3) photon/sq cm/s, while for approximately 1 day intervals our 3 sigma upper limits are characteristically 4.9 x 10(exp -3) photon/sq cm/s. These results imply a duty cycle of less than 1.3% for the transient line measured from 1H 1822-371 during a approximately 3 week interval in 1977 by HEAO 1, and a duty cycle of less than or = 0.8% for the transient line detected in 1990 and 1992 from 1E 1740.7-2942 on approximately 1 day timescales by SIGMA.

Harris, Michael J.↗

Two-Flux and Green's Function Method for Transient Radiative Transfer in a Semi-Transparent Layer

A method using a Green's function is developed for computing transient temperatures in a semitransparent layer by using the two-flux method coupled with the transient energy equation. Each boundary of the layer is exposed to a hot or cold radiative environment, and is heated or cooled by convection. The layer refractive index is larger than one, and the effect of internal reflections is included with the boundaries assumed diffuse. The analysis accounts for internal emission, absorption, heat conduction, and isotropic scattering. Spectrally dependent radiative properties are included, and transient results are given to illustrate two-band spectral behavior with optically thin and thick bands. Transient results using the present Green's function method are verified for a gray layer by comparison with a finite difference solution of the exact radiative transfer equations; excellent agreement is obtained. The present method requires only moderate computing times and incorporates isotropic scattering without additional complexity. Typical temperature distributions are given to illustrate application of the method by examining the effect of strong radiative heating on one side of a layer with convective cooling on the other side, and the interaction of strong convective heating with radiative cooling from the layer interior.

Siegel, Robert↗

Steady-State and Transient Boundary Element Methods for Coupled Heat Conduction

Boundary element algorithms for the solution of steady-state and transient heat conduction are presented. The algorithms are designed for efficient coupling with computational fluid dynamic discretizations and feature piecewise linear elements with offset nodal points. The steady-state algorithm employs the fundamental solution approach; the integration kernels are computed analytically based on linear shape functions, linear elements, and variably offset nodal points. The analytic expressions for both singular and nonsingular integrands are presented. The transient algorithm employs the transient fundamental solution; the temporal integration is performed analytically and the nonsingular spatial integration is performed numerically using Gaussian quadrature. A series solution to the integration is derived for the instance of a singular integrand. The boundary-only character of the algorithm is maintained by integrating the influence coefficients from initial time. Numerical results are compared to analytical solutions to verify the current boundary element algorithms. The steady-state and transient algorithms are numerically shown to be second-order accurate in space and time, respectively.

Kontinos, Dean A.↗