Search NASA⌕ Search

SEARCH · Search NASA

Results for “trip analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

TRACE Input Modernization

This work presents a Tom’s Obvious Minimal Language (TOML)-based representation of input for the US Nuclear Regulatory Commission’s TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics code. Implemented using the Workbench Analysis Sequence Processor (WASP), the approach maps traditional TRACE input structures to a hierarchical format composed of named parameters, typed values, and native data collections. The resulting representation preserves TRACE’s existing modeling capabilities while providing a modern, structured interface for model development and management. WASP further extends TOML through a file import directive that supports modular model composition and reusable input organization. In addition, WASP provides extended array data entry convenience with various data repeat and interpolation capabilities. Examples of the new TOML syntax are provided for major TRACE input categories, including hydraulic components, heat structures, control systems, and trip logic. The TOML representation establishes a foundation for improved validation, tooling, automation, and model maintainability while remaining compatible with existing TRACE workflows. To facilitate migration to the TOML-based input format, the TRACE executable now supports conversion of native TRACE input into an intermediate JSON representation. A Python utility subsequently transforms the JSON data into an equivalent TOML model. Lastly, the TRACE executable now supports execution using TOML-formatted input.

Lefebvre, Robert A. [Oak Ridge National Laboratory↗

Implementation of a realistic artificial data generator for crash data generation

In this paper, a framework is outlined to generate realistic artificial data (RAD) as a tool for comparing different models developed for safety analysis. The primary focus of transportation safety analysis is on identifying and quantifying the influence of factors contributing to traffic crash occurrence and its consequences. The current framework of comparing model structures using only observed data has limitations. With observed data, it is not possible to know how well the models mimic the true relationship between the dependent and independent variables. Further, real datasets do not allow researchers to evaluate the model performance for different levels of complexity of the dataset. RAD offers an innovative framework to address these limitations. Hence, we propose a RAD generation framework embedded with heterogeneous causal structures that generates crash data by considering crash occurrence as a trip level event impacted by trip level factors, demographics, roadway and vehicle attributes. Within our RAD generator we employ three specific modules: (a) disaggregate trip information generation, (b) crash data generation and (c) crash data aggregation. For disaggregate trip information generation, we employ a daily activity-travel realization for an urban region generated from an established activity-based model for the Chicago region. We use this data of more than 2 million daily trips to generate a subset of trips with crash data. For trips with crashes crash location, crash type, driver/vehicle characteristics, and crash severity. The daily RAD generation process is repeated for generating crash records at yearly or multi-year resolution. In conclusion, the crash databases generated can be employed to compare frequency models, severity models, crash type and various other dimensions by facility type - possibly establishing a universal benchmarking system for alternative model frameworks in safety literature.

42 ENGINEERING↗

Reversible solid oxide cells: Early performance and microstructural evolution during electrolysis and switched mode operation

Incorporating more renewables into our energy mix will require a diversity of technological solutions. Reversible solid oxide cell systems (RSOCs) operating reversibly between fuel cell and electrolysis modes with high round-trip efficiencies offer one such solution. However, questions remain about the stability of the oxygen and fuel electrodes under reversible operation. Here, in this study, single cells with the configuration Ni-YSZ|YSZ|GDC10|NNO-NDC50|NNO are operated by reversible cycling under potentiostatic conditions. Test conditions are chosen to be representative of average stack conditions that are likely to be encountered during operation of a stack constructed of such cells. The results of reversible cycling over 500 h (21 cycles) are compared with operating the cells under potentiostatic conditions in the electrolysis-only mode (i.e., without cycling). Voltage-current density (DC), AC complex impedance spectroscopy, distribution of relaxation times (DRT) analysis, and scanning electron microscopy (SEM) indicate excellent reversibility and stability of the neodymium nickelate-based oxygen electrodes in both electrolysis and reversible cycling modes. Degradation behavior is attributed to the loss and coarsening of connected Ni particles in the fuel electrode, particularly in the active layer. However, reversible operation mitigates this degradation compared to operation in the electrolysis-only (SOEC-only) mode.

25 ENERGY STORAGE↗

The ABCs of On-Demand Transit (ODT)

On-demand mobility - also referred to as on-demand transit (ODT) - is a form of public mobility that is flexible with respect to where and when service is provided, and ODT deployments have increased significantly in recent years. Transit agencies are becoming increasingly interested in ODT, and due to differing definitions and various service design and business model options, it can be difficult to learn about the emerging industry. This work provides an overview of the definitions of ODT, recent trends internationally and in the U.S., ODT's benefits and challenges (particularly compared to fixed-route transit), three primary service design options, system costs and funding considerations, and a metrics framework for evaluating ODT systems to ensure continued successful performance. Identified benefits include increased service areas, short ride and wait times, increased user flexibility, potential to reduce energy consumption and emissions through shared trips and smaller, right-sized vehicles, increased safety and comfort through door-to-door service, and rich data streams including granular spatio-temporal data that can be analyzed to continuously improve the service. Challenges include scaling ODT service up as small increases in ridership require additional supply to keep service quality high, serving peak times including keeping low wait times, the lack of fixed schedule being challenging for commuters, integrating ODT services with nearby transit systems, and equity for riders without smartphones who cannot track the vehicle in a mobile app. Finally, an overview of seven ODT case studies (in Texas, Missouri, New York, and Ontario, Canada) performed by NREL and related analysis of travel time, energy and emissions, costs, and equity are presented. Initial key findings include: ODT can be cost- and energy-effective compared to fixed-route transit, ODT serves more people than other transit options, and ODT system deployments can be followed by rapid growth.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

Closed Loop Pumped Storage Hydropower Resource Assessment of the United States

The data includes a geospatial and spreadsheet representation of a resource analysis for closed loop pumped storage systems across the Continental United States, Alaska, Hawaii, and Puerto Rico. The data includes energy storage potential, water volume, distance from source to storage, hydraulic head, dollars per kilowatt of storage, and transmission spurline cost for each pumped storage hydropower (PHS) reservoir. Each reservoir represented in this dataset is represented on potential 10 hour storage duration PSH system comprised of two reservoirs. Units of measure are laid out in the dataset. Pumped storage hydropower (PSH) represents the bulk of the United States' current energy storage capacity: 23 gigawatts (GW) of the 24 GW national total (Denholm et al. 2021). This capacity was largely built between 1960 and 1990. PSH is a mature and proven method of energy storage with competitive round-trip efficiency and long life spans. These qualities make PSH a very attractive potential solution to energy storage needs, particularly for longer-duration storage (8 hours or more); such storage will be crucial to bridge gaps in electricity production as variable wind and solar production continue to comprise an ever-larger portion of the United States' energy portfolio. This study seeks to better understand the technical potential for PSH development in the United States by developing a national-scale resource assessment for closed-loop PSH. For more information, please refer to the Closed Loop Pumped Storage Hydropower Resource Assessment for the United States linked in the resources.

Array↗

Entropy-Stabilized Multication Fluorides as a Conversion-Type Cathode for Li-Ion Batteries–Impact of Element Selection

Metal fluorides (e.g., FeF 2 and FeF 3 ) have received attention as conversion-type cathode materials for Li-ion batteries due to their higher theoretical capacity compared to that of common intercalation materials. However, their practical use has been hindered by low round-trip efficiency, voltage hysteresis, and capacity fading. Cation substitution has been proposed to address these challenges, and recent advancements in battery performance involve the introduction of entropy stabilization in an attempt to facilitate reversible conversion reactions by increasing configurational entropy. Building on this concept, high entropy fluorides with five cations were synthesized by using a simple mechanochemical route. In order to examine the impact of element selection, Co 0.2 Cu 0.2 Ni 0.2 Zn 0.2 Fe 0.2 F 2 (HEF-Fe) was compared with Co 0.2 Cu 0.2 Ni 0.2 Zn 0.2 Mg 0.2 F 2 (HEF-Mg), replacing electrochemically inactive Mg with Fe as an active participant in the conversion reaction. Combining electrochemical measurements with first-principles calculations, high-resolution electron microscopy, and synchrotron X-ray analysis, HEFs’ battery performances and conversion reaction mechanisms were investigated in detail. The results highlighted that replacement of Mg with Fe was beneficial, with enhanced capacity, rate capability, and surface stability. In addition, it was found that HEF-Fe showed similar cycle stability without an electrochemically inactive element. In conclusion, these findings provide valuable insights for the design of high entropy multielement fluorides for improved Li-ion battery performance.

25 ENERGY STORAGE↗

Effect of Accurate Modeling of Converter Interfaced Generation (CIG) on a Practical Bulk Power System

With increased penetration of converter interfaced generation (CIG) in power systems, it becomes imperative to adequately model them in both steady-state and dynamic simulations. There are several modeling approaches and simulation platforms for CIG. In addition, it is noted that suitability of modeling approaches and models is also dependent on the system conditions. However, their suitability has yet to be systematically analyzed, and this becomes a challenge in the industry without a systemic method. To tackle these challenges, in this paper, we first develop a methodology for identifying the maximum penetration of aggregated rooftop sources that can be represented as negative loads in both the steady state and dynamic analysis. Then we verify the suitability of positive-sequence performance-based model and detailed electromagnetic transient (EMT) model for utility-scale PV plants under different fault conditions. Based on the results, we perform dynamic simulations on a large practical system with both positive-sequence transient stability(TS) and EMT-TS hybrid simulation. Our study shows that positive-sequence performance based PV plant model is more suitable for study cases with faults relatively far away from the point of connection, and that positive-sequence models and TS simulation approach can produce comparable results with reference to EMT-TS hybrid simulation for normally-cleared single-line-to-ground faults, but the inadequacy of positive-sequence based model and simulation approach becomes obvious for prolonged-tripping of unbalanced faults in proximity of the PV plants.

Huang, Qiuhua↗

Decision Support Tool for Planning Neighborhood-Scale Deployment of Low-Speed Shared Automated Shuttles

Increasing interest and investment in connected, automated, and electric vehicles as well as mobility-as-a-service (MaaS) concepts are paving the way for the next major transformation in transportation through automated and shared mobility. The initial excitement toward rapid deployment and adoption of automated vehicles (AVs) has subsided, and low-speed automated shuttles are emerging as a more pragmatic pathway for introducing automated mobility in geofenced districts. Such shuttles hold the promise to provide a viable alternative for serving short trips in urban districts with high travel densities. As interest in low-speed automated shuttle systems (to improve urban mobility) increases, the need for tools that can inform communities in relation to benefits or disadvantages of automated shuttle deployments is imminent. However, most of the existing transportation planning and simulation tools are not capable of handling emerging shared automated mobility options. This paper presents a microscopic simulation toolkit that can be used by cities and communities to plan for the deployment of low-speed automated shuttles systems, as well as other shared mobility options. Labeled as the Automated Mobility District modeling and simulation toolkit, the proposed decision support tool intends to help cities evaluate the mobility and sustainability impacts of deploying shared automated vehicles (SAVs) in geofenced regions. This paper describes the toolkit, as well as a sample scenario analysis for the deployment of low-speed automated shuttles in Greenville, South Carolina, U.S. Results from the scenario study demonstrate the effectiveness of the proposed simulation toolkit in planning for advanced mobility systems.

47 OTHER INSTRUMENTATION↗

A highly efficient and durable air electrode for intermediate-temperature reversible solid oxide cells

Solid oxide cells (SOCs) are considered the most efficient system for reversible conversion between chemical and electrical energy, thus having potential to be an attractive technology for a sustainable energy future. To achieve high round-trip efficiency, highly efficient and durable air electrode materials are needed to minimize energy loss associated with oxygen reduction reaction (ORR) and oxygen evolution reaction (OER). Here we report a bi-functional air electrode material, PrBa 0.9 Co 1.96 Nb 0.04 O 5+δ , demonstrating outstanding electrochemical performance (e.g., achieving peak power densities of over 1.5 and 1 W cm –2 , respectively, for Gd 0.1 Ce 0.9 O 1.95 and BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ based fuel cells at 600 °C) while maintaining excellent stability (e.g., having a degradation rate of 40 mV per 1,000 h for H 2 O electrolysis cells). Finally, the excellent property of the new electrode is attributed to the improved stability from Nb doping and the enhanced electrocatalytic activity from tuning Ba deficiency, as confirmed by experimental results and computational analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Decision Support Tool for Planning Neighborhood-Scale Deployment of Low-Speed Shared Automated Shuttles

Increasing interest and investment in connected, automated, and electric vehicles, and mobility-as-a-service concepts are paving the way for the next major shift in transportation through automated and shared mobility. The initial excitement towards rapid deployment and adoption of automated vehicles has subsided, and low-speed automated shuttles are emerging as a more pragmatic pathway for introducing automated mobility in geo-fenced districts. Such shuttles hold the promise to provide a viable alternative for serving short trips in urban districts with high travel densities. As interest in low-speed automated shuttle systems (to improve urban mobility) increases, the need for tools that can inform communities regarding benefits or dis-benefits of automated shuttle deployments is imminent. However, most of the existing transportation planning and simulation tools are not capable of handling emerging shared automated mobility options. This presentation presents a microscopic simulation toolkit that can be used by cities and communities to plan for the deployment of low-speed automated shuttles systems, as well as other shared mobility options. Labeled as the Automated Mobility District (AMD) modeling and simulation toolkit, the proposed decision support tool can help cities evaluate the mobility and sustainability impacts of deploying shared automated vehicles in geofenced regions. This paper presents a description of the toolkit, as well as a sample scenario analysis for the deployment of low-speed automated shuttles in Greenville, South Carolina. Results from the scenario study demonstrate the effectiveness of the proposed simulation toolkit in planning for advanced mobility systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

System Study: Residual Heat Removal 1998-2020

This report presents an unreliability evaluation of the residual heat removal (RHR) system in two modes of operation (low-pressure injection in response to a large loss-of-coolant accident and in response to post-trip shutdown cooling) at 104 U.S. commercial nuclear reactors. Demand, run hour, and failure data from 1998–2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the RHR results.

99 GENERAL AND MISCELLANEOUS↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Electrochemical recovery of Gd into liquid Bi in molten LiCl-KCl-GdCl 3

The electrochemical recovery of Gd into liquid Bi electrodes was investigated in molten LiCl-KCl-GdCl 3 electrolyte at 773–973 K using constant currents of 10–150 mA cm −2 . High round-trip coulombic efficiency (>97 %) was demonstrated for deposition and removal of Gd into and from liquid Bi at all temperatures, confirming chemically reversible electrode reactions towards high recovery yield of Gd using liquid Bi. Furthermore, the overpotential associated with deposition of Gd into the liquid Bi electrode gradually increased with current density and decreased with temperature. At the lowest temperature of 773 K, a steep increase in overpotential was evident at high current densities due to slower mass transport and low solubility of Gd in liquid Bi (0.5 at.% Gd). Based on the impedance spectra of Bi electrodes at 773–973 K, the exchange current density was estimated to be 110–220 mA cm −2 , indicating facile charge transfer at the liquid electrode-electrolyte interface. Post-mortem characterization of Bi cathodes after electrolysis at 873 K indicated the formation of a solid GdBi(s) compound layer at the Bi electrode surface. Chemical analysis of Bi cathodes at various deposited Gd compositions resulted in Faradaic efficiencies of ∼75–84 %, promising a high recovery yield of Gd from molten salts using a strongly-interacting liquid Bi electrode.

36 - MATERIALS SCIENCE↗

E-scooter safety: How attitudinal factors influence risky behavior among shared e-scooter riders

In recent years, e-scooter usage for short-distance trips has grown rapidly. This surge in e-scooter use, combined with the high exposure of e-scooter riders to accident risk, has sparked concerns regarding e-scooter safety. Despite some studies focusing on e-scooter safety, little is known about how attitudinal factors lead e-scooter riders to engage in risky riding behaviors. In this paper, we developed a survey-based empirical model to identify the attitudinal factors influencing engagement in risky behaviors among e-scooter users. We used survey data collected from 420 shared e-scooter users in Chicago in 2022. The survey showed that 47.7% of respondents had experienced at least one collision or fall-off while riding e-scooters. We employed the Partial Least Squares Structural Equation Model (PLS-SEM) to examine the relationships between latent attitudinal factors and risky behavior engagement. Moreover, we conducted Permutation Multi-group Analysis (PMGA) to assess the moderating effect of socio-demographic factors within the estimated model. The findings suggest that riders’ unsafe riding attitude and riding confidence are the most influential factors shaping their risky behavior engagement. In addition, accident experience, infrastructure suitability, perceived enjoyment, traffic risk perception, and operational risk perception are among the other significant predictors. Among socio-demographic factors, gender, age, education, and car use frequency significantly influence riders’ engagement in risky behaviors. The results highlight the importance of infrastructure suitability and accident experience in analyzing e-scooter users’ riding behavior. The developed model advances our understanding of factors contributing to e-scooter riders’ risky behavior engagement. The findings offer valuable insights for policymakers and e-scooter vendors aiming to mitigate e-scooter users’ accident risk. Specifically, we recommend three safety countermeasures: (1) safety training programs to encourage a safer attitude, (2) practice-based initiatives to enhance riding confidence, and (3) infrastructure improvements, especially the expansion of bike lanes.

E-scooter↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗