Search NASA⌕ Search

SEARCH · Search NASA

Results for “tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Temporally and spatially resolved X-ray densitometry in a shock tube

Gas densities were measured by x-ray absorption spectroscopy to examine spatial inhomogeneity in density behind incident and reflected shock waves in a miniature (12.7 mm bore) high repetition rate shock tube. Shock waves were generated in argon. The pressure and temperature behind the incident shock were P 2 ~ 1.72 bar and T 2 ~ 800 K, while those behind the reflected shock were P 5 ~ 6.5 bar and T 5 ~ 1480 K. Time-resolved line-of-sight transmission measurements using x-rays at 9 keV photon energy were made along various axial and transverse locations covering the entire shock tube cross section. The x-ray transmission at each location was converted to pathlength-integrated densities, which in some conditions could be further converted to pathlength-averaged densities. The measured gas densities were compared with those calculated by the normal shock wave relations, and good agreement was found in the preshock and immediately behind the incident shock regions. Similar agreement was found for reflected shock conditions very near the endwall. However, increasingly large differences between the measured and calculated gas densities were found as distance from the endwall increased. Furthermore, reconstruction by Abel inversion allowed time and radially resolved densities to be obtained from the transverse measurements. While the profiles measured in this experiment are of insufficient signal-to noise level and resolution to definitively assign boundary layer thicknesses, future improvements may be able to do this. The radially resolved densities reveal growing sidewall thermal boundary layers in gases behind the reflected shock. These reconstructions were compared with a model of the thermal boundary layer and are consistent with values of the thermal boundary layer thickness being between 0.25 mm and 1 mm at 0.7 ms after shock reflection.

42 ENGINEERING↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Millimeter wave traveling wave tubes for the 21st Century

Traveling wave tubes are rapidly evolving to provide unprecedented power level in comparison to solid state devices in the millimeter waves region of the spectrum (80–300 GHz) thus enabling a wide range of applications. Wireless communications, imaging, plasma diagnostics, healthcare and many others will gain substantial features if high power at millimeter waves would be available from compact sources. The development of fabrication technologies is proving crucial for introducing new topologies and structures for millimeter wave vacuum electronic devices, compatible with the dimensions dictated by the short wavelength that poses substantial manufacturing challenges due to tight tolerances. This review paper will provide an overview of the principles, evolution and state of the art of one of the most widely utilized vacuum electronic device, the traveling wave tube (TWT). The wide band, high gain features of TWTs make those devices the most promising solutions for high power at millimeter waves and THz frequencies.

42 ENGINEERING↗

(U) Blast Tube Rehabilitation (Final Design Review) [Slides]

Saddle design is being proposed to improve overall response of facility. No plasticity predicted in tube sections buying down risk of a catastrophic failure. Plasticity is predicted in the support for loadings representing 190# C4. The design has been iterated to decrease localized plasticity and buy down risk. It is recommended that no amount of explosive driver be placed in A36 sections. Previous work suggests yielding can develop in the tube section causing rupture. J2 colleagues have reviewed analysis results. Outstanding question of additional plastic strain is developing from subsequent uses.

42 ENGINEERING↗

3D Printing of Solar Absorber Tube with Internal/External Structures for Heat Transfer Enhancement and Temperature Leveling using Additive Manufacturing Technology

In this project, to tackle the technical obstacles, we utilized Laser Additive Alloying (LAA), an additive manufacturing (AM) technology, to 3D print the entire absorber tube with optimized helical fins to improve heat transfer at the expense of minimized pressure drop increase. The 3D printed absorber tubes can increase the uniformity of circumferential temperature distribution, reduced the thermal stresses, decrease the heat loss, and reach the target receiver thermal efficiency.

14 SOLAR ENERGY↗

Fractional Skyrmion Tubes in Chiral‐Interfaced 3D Magnetic Nanowires

Magnetic skyrmions are chiral spin textures with rich physics and great potential for unconventional computing. Typically, skyrmions form in bulk crystals with reduced symmetry or ultrathin film multilayers involving heavy metals. Here, the formation of fractional Bloch skyrmion tubes at room temperature is demonstrated by 3D printing ferromagnetic double‐helix nanowires with two regions of opposite chirality. Using X‐ray microscopy and micromagnetic simulations, it is shown that the coexistence of vortex and anti‐parallel spin states induces the formation of fractional skyrmion tubes at zero magnetic fields, minimizing the energy cost of breaking the coupling between geometric and magnetic chirality. Control over zero‐field states is also demonstrated, including pure vortex, or mixed skyrmion‐vortex states, highlighting the magnetic reconfigurability of these 3D nanowires. This work shows how interfacing chiral geometries at the nanoscale can enable advanced forms of topological spintronics.

X-ray microscopy↗

Entanglement entropy of a color flux tube in (2+1)D Yang-Mills theory

We construct a novel flux tube entanglement entropy (FTE 2 ), defined as the excess entanglement entropy relative to the vacuum of a region of color flux stretching between a heavy quark-anti-quark pair in pure gauge Yang-Mills theory. We show that FTE 2 can be expressed in terms of correlators of Polyakov loops, is manifestly gauge-invariant, and therefore free of the ambiguities in computations of the entanglement entropy in gauge theories related to the choice of the center algebra. Employing the replica trick, we compute FTE 2 for SU(2) Yang-Mills theory in (2+1)D and demonstrate that it is finite in the continuum limit. We explore the properties of FTE 2 for a half-slab geometry, which allows us to vary the width and location of the slab, and the extent to which the slab cross-cuts the color flux tube. Following the intuition provided by computations of FTE 2 in (1+1)D, and in a thin string model, we examine the extent to which our FTE 2 results can be interpreted as the sum of an internal color entropy and a vibrational entropy corresponding to the transverse excitations of the string.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Speed X-Ray Stereo Digital Image Correlation in a Shock Tube

X-ray stereo digital image correlation (DIC) measurements were performed at 10 kHz on the internal surface of a jointed structure in a shock tube at a shock Mach number of 1.42 and compared with optical stereo DIC measurements on the outer, visible surface of the structure. The shock tube environment introduces temperature and density gradients in the gas through which the structure was imaged, resulting in spatial and temporal index of refraction variations. These variations cause bias errors in optical DIC measurements due to beam-steering but have minimal influence on x-ray DIC measurements. These results demonstrate the utility of time-resolved x-ray DIC measurements in complicated environments where optical measurements suffer severe errors and/or are precluded by lack of optical access.

42 ENGINEERING↗

Experimental investigation of probabilistic failure of SiC/SiC composite tubes under multiaxial loading

This paper presents an experimental investigation of the failure behavior of SiC fiber-reinforced SiC matrix (SiC/SiC) composite tubes under multiaxial loading. A new testing apparatus is designed to independently apply axial stress and internal pressure to SiC/SiC tubes. Acoustic emission (AE) is used to monitor the damage growth in the specimen. Based on the measured stress–strain response, a strain-based criterion is proposed to determine the proportional limit stress (PLS). The proposed strain-based criterion is compared with the PLS determined by the AE measurement. The PLS is determined for different loading ratios to form a multiaxial failure surface. By testing multiple replicates, the statistical variations of the PLS are determined. In conclusion, based on the experimental results, a mathematical model is developed to characterize the probability distribution of the PLS of SiC/SiC composites under multiaxial loading.

36 MATERIALS SCIENCE↗

Experimental investigation of Multi-Mode heat transfer to a Free-Falling dilute particle cloud in a heated vertical tube

The development of dilute particle heat exchangers and reactors for advanced energy systems requires an understanding of the multi-mode heat transfer from a heated wall to falling particles. This study presents experimental results of the overall heat transfer coefficient for a free-falling, dilute flow of particles with solid volume fraction from 0.0005 to 0.006 corresponding to feed rates from 3.7 kg s -1 m -2 to 44 kg s -1 m -2 in a vertical, heated tube containing quiescent air at atmospheric pressure. Tube wall temperatures are varied between 300°C to 900°C while keeping the particle inlet temperature constant. The experimental results show that the overall heat transfer coefficient is a strong function of particle feed rate and surface temperature. Good agreement was obtained with prior studies conducted at comparable temperatures but lower particle feed rates (< 4 kg m -2 s -1 ). The established correlations for particle-to-wall radiation and particle-to-gas convection were used to estimate the wall-to-gas convective contribution from the measured overall heat transfer coefficient. The experimental results indicated a 4 to 6 times improvement in the wall convection in the solid-gas mixture compared to that expected from natural convection in a single-phase gas. Furthermore, the data presented here are applicable to characterize heat transfer in dilute particle heat exchangers, furnaces, and solar receivers.

14 SOLAR ENERGY↗

A fast reduced model for a shell-and-tube based latent heat thermal energy storage heat exchanger and its application for cost optimal design by nonlinear programming

Numerical simulation of latent heat thermal energy storage (LHTES) systems plays a fundamental role in studying the physical process and guiding the engineering design. Discretization of the PDEs describing the nonlinear solidification/melting process of phase change materials (PCMs) leads to a large-scale complex dynamics system, where the system behavior depends on a set of parameters. In a design setting, repeated model evaluations are required over the set of parameters results in significant computational burden. In this paper, an explicit analytic solution was built for the propagation of the solidification front in a cylindrical coordinate. The analytic solution approach is further employed to develop a low computational reduced model (RM) as a module for a shell-and-tube based LHTES heat exchanger. The levelized Cost of Energy (LCOE) is used as a design metric and the RM model is used to apply system-level constraints in the nonlinear programming formulation that facilitates efficient global optimal design of the PCM properties, flow conditions and tube geometries. The use of LCOE as the design metric prevents over design of the heat transfer rate and also establishes a fair ground for evaluation of different thermal storage technologies and their integrated applications with other systems. Optimal results showed that a higher effectiveness results in a higher LCOE; the velocity of the HTF and the length of the channel are highly correlated with each other; both larger PCM latent energy and conductivity result in lower LCOE.

25 ENERGY STORAGE↗

Fracture toughness evaluation for Zr-4 clad tubing structure with pellet inserts

Applying fracture mechanics approach to spent nuclear fuel (SNF) system reliability investigation is warranted due to the inherent flaws and hydride structures existed in a SNF system after nuclear reactor operation. However, none of the existing fracture toughness data deal with fuel cladding specific geometry or spent fuel material conditions, such as cladding structure with the pellet-inserts and the associated pellet clad mechanical interactions induced mixed-mode damage mechanisms. Thus, the development of an intrinsic fracture mechanics approach that is suitable for SNF materials is needed. Due to thin wall and small dimension of clad tubing structure, the spiral notch torsion test (SNTT) method of small specimen approach was used to estimate the clad tubing structure fracture toughness. The estimated fracture toughness for Zr-4 cladding with alumina-pellet inserts are presented in this report. For SNTT samples with a short or medium crack length, between 5.4-mm and 8-mm, the estimate JIQ upon fracture initiation for the baseline Zr-4 cladding is at 50 kJ/m2 with 2-sigma uncertainty of 3.26 kJ/m2, and the associated KIQ is at 67.46 MPa√m. For SNTT samples with a long crack length, around 13-mm, the crack initialization is deviated from that of the Mode-I tensile fracture and appears to be a mixed-mode fracture of Mode I – tensile stress and Mode III – out of plane shear stress; the estimated JMQ is at 18.9 kJ/m2, the associated KMQ is at 41.4 MPa√m.

36 MATERIALS SCIENCE↗

Solenoid actuated driver valve for high repetition rate shock tubes

A high speed, high pressure solenoid actuated valve has been developed for use as a driver section for automated shock tubes. The valve is based on a prior design, and significant improvements in the design of the valve are described in this paper. The new design retains the performance of prior versions of the valve and creates very reproducible reaction conditions in the shock tube, which are illustrated by several thousand experiments. Additionally, the longevity of the valve is improved, failures are reduced, and the maintenance and manufacture of the valve are simplified.

47 OTHER INSTRUMENTATION↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Characterization of a new ultra-high pressure shock tube facility for combustion and propulsion studies

A new shock tube facility has been designed, constructed, and characterized at the University of Central Florida. This facility is capable of withstanding pressures of up to 1000 atm, allowing for combustion diagnostics of extreme conditions, such as in rocket combustion chambers or in novel power conversion cycles. For studies with toxic gas impurities, the high initial pressures required the development of a gas delivery system to ensure the longevity of the facility and the safety of the personnel. Data acquisition and experimental propagation were implemented with remote access to ensure safety, paired with a LabVIEW- and Python-based user interface. Thus far, test pressures of 270 atm, blast pressures of 730 atm, and temperatures approaching 10 000 K have been achieved. The extreme limitations of this facility allow for emission spectroscopy to be performed during the oxidation of fuel mixtures, e.g., alkanes diluted in argon and carbon dioxide. Ignition delay times were determined and compared to simulations using chemical kinetic mechanisms. The design, experimental procedures, processes of analysis, and uncertainty determination are outlined, and typical pressure profiles are compared with a new gas dynamics solver and empirical correlations developed across multiple shock tube facilities. Preliminary reactive mixture analyses are included with further investigation of the mixtures outlined.

47 OTHER INSTRUMENTATION↗

Multiaxial Plastic Deformation of Zircaloy-4 Nuclear Fuel Cladding Tubes

Here, this work is motivated by the desire to devise an internal pressure test that can mimic a displacement-controlled loading scenario and demonstrate how to apply the multiaxial stress and strain data from the test to develop an elastic/plastic constitutive model for a thin-walled tubular component. This is achieved by conducting simultaneous measurements of tangential and axial strain during the pressure test and integrating these strain measures into a feedback loop with the pressure controller. It is shown how data from such a test can be used to develop a large mechanical property data set relevant to biaxial loading conditions. The data obtained have high confidence evidenced by their low variability and alignment with other literature studies. Additionally, data from these internal pressure tests combined with full-tube axial tensile tests allow for the derivation of the Hill anisotropic yield function. The developed Hill yield function is validated by comparing the plastic strain ratios from the full-tube tension tests and by comparing the predicted yield stress in the tangential direction with measured values from ring tension tests in a previous study.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗