Search NASA⌕ Search

SEARCH · Search NASA

Results for “units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Life Cycle Analysis of Natural Gas Supply Chain and End Use Applications in the United States

Natural gas (NG) plays a crucial role in current and future energy systems in the United States due to its abundance and affordability. In this study a life cycle analysis of the NG supply chain in the United States was conducted using Argonne's R&D GREET model, examining stages from recovery to distribution using reported field data processed and documented by National Energy Technology Laboratory. Supply chain emissions were evaluated across multiple spatial scales, including national average, overall regional production, region-to-region, and basin-to-region scenarios. The GHG intensity of the U.S. average NG supply chain was estimated at 10.3 kg CO 2 e/MMBtu (lower heating value), with a range across regions from 7.8 kg CO 2 e/MMBtu (Northeast) to 15.1 kg CO 2 e/MMBtu (Pacific). The analysis further assessed how upstream NG emissions influence the life cycle GHG emissions of key end-use applications, including electricity generation (0.044–0.086 kg CO 2 e/kWh from upstream NG in combined cycle facilities), hydrogen production (1.04–2.20 kg CO 2 e/kg H 2 for steam methane reforming [SMR] and 1.06–2.23 kg CO 2 e/kg for autothermal reforming [ATR]), and transit bus operation utilizing compressed natural gas fuel (0.19–0.37 kg CO 2 e/mile) and hydrogen fuel (0.12–0.25 kg CO 2 e/mile for hydrogen produced in SMR and ATR).

compression↗

A Decomposition-Based Learn-To-Optimize Approach with Feasibility Layer Assistance for Sub-Hourly Unit Commitment

Sub-hourly unit commitment (UC) with 15-min intervals is gaining significant attention as a way to respond rapidly to the fluctuations in electricity supply and demand introduced by renewable resources. However, the increased temporal resolution and complex inter-temporal dependencies pose substantial computational challenges for traditional optimization methods. To this end, this paper explores a decomposition-based learn-to-optimize approach. Building on recent advances in machine learning, our method revisits the long- overlooked Lagrangian relaxation framework, which is a classical decomposition technique that enables tractable subproblem solving. These smaller subproblems are inherently well-suited for machine learning, as their reduced dimensionality and structural regularity allow predictive models to efficiently learn and generalize solution patterns. We thus propose a generic predictive model, which embeds Gated Recurrent Units (GRUs) and Attention in the encoder-decoder structure, and integrate a rule-based feasibility layer to capture temporal dependencies, reduce training effort, and improve feasibility w.r.t. unit-level constraints. Our method has been validated on the IEEE 118-bus system, demonstrating promising performance in solving sub-hourly UC problems efficiently and feasibly.

97 MATHEMATICS AND COMPUTING↗

Techno-economic analysis and network design for CO 2 conversion to jet fuels in the United States

The conversion of carbon dioxide (CO 2 ) into jet fuel holds significant potential for reducing CO 2 emissions, providing an alternative to carbon-based resources, and offering a renewable means of energy storage. The objective of this study is to conduct a techno-economic analysis and optimize the supply chain network for converting CO 2 to jet fuel in the United States, aiming to minimize total costs while assessing the environmental and economic feasibility of two CO 2 conversion pathways. This first pathway is based on Fischer-Tropsch synthesis (FTS), and the other one is based on the valorization and upgrading of light methanol (MeOH). Incorporating spatial and techno-economic data, a mixed-integer linear programming model was developed to select source plants and conversion pathways, locations of conversion refinery sites, and the amount of captured CO 2 across the United States. The optimal results indicate that the FTS pathway is adopted at all selected refineries when the hydrogen price is 1000 dollars/t and the operating cost, mainly electricity used in conversion, is reduced to 5 % of its current level. Under this scenario, the total annual profit is 8 billion dollars, and the net carbon emissions are -88,783,284 tons. The sensitivity analyses reveal that the prices of electricity and hydrogen significantly contribute to total production costs. The CO 2 recycle percentage of the FTS pathway influences the choice of applied pathways at refineries. Additionally, a higher conversion rate holds a substantial promise for reducing the total production cost and can make the MeOH pathway a viable choice.

10 SYNTHETIC FUELS↗

gRASPA

GPU Monte Carlo Simulation Code with a taste of RASPA We present enhancements in Monte Carlo simulation speed and functionality within an open-source code, gRASPA, which uses graphical processing units (GPUs) to achieve significant performance improvements compared to serial, CPU implementations of Monte Carlo. The code supports a wide range of Monte Carlo simulations, including canonical ensemble (NVT), grand canonical, NVT Gibbs, Widom test particle insertions, and continuous-fractional component Monte Carlo. Implementation of grand canonical transition matrix Monte Carlo (GC-TMMC) and a novel feature to allow different moves for the different components of metal-organic framework (MOF) structures exemplify the capabilities of gRASPA for precise free energy calculations and enhanced adsorption studies, respectively. The introduction of a High-Throughput Computing (HTC) mode permits many Monte Carlo simulations on a single GPU device for accelerated materials discovery. The code can incorporate machine learning (ML) potentials. The open-source nature of gRASPA promotes reproducibility and openness in science, and users may add features to the code and optimize it for their own purposes. The code is written in CUDA/C++ and SYCL/C++ to support different GPU vendors. The gRASPA code is publicly available at https://github.com/snurr-group/gRASPA.

Li, Zhao [Purdue/Northwestern/Notre Dame Universit↗

Leaf-level physiological strategies related to productivity and plasticity of Populus in the Southeastern United States

Introduction: Populus and its hybrids are attractive bioenergy crops and the southeastern United States has broad ability to supply bioenergy markets with woody biomass. Breeding and hybridization have led to superior eastern cottonwood (Populus deltoides W. Bartram ex Marshall) and hybrid poplars adapted to a wide variety of site types not suited for agricultural production. In order to maximize productivity and minimize inputs, genotypes need to efficiently use available site resources and tolerate environmental stresses. In addition, we need to determine plasticity of traits and their coordination across sites to select traits that will broadly characterize genotypes. Therefore, our study objectives were to determine (1) which leaf traits were correlated with growth, (2) if traits and genotypes exhibited significant plasticity across sites, and (3) how traits were coordinated within and across sites and Populus taxa. Methods: We measured trees at two sites in northeastern Mississippi, United States: one upland and one alluvial terrace site. Genotypes included eastern cottonwoods as well as F 1 crosses of eastern cottonwood and P. maximowiczii (Henry), P. nigra (L.) and P. trichocarpa (Torr. & Gray). Results: We found that sites differed in which leaf traits were correlated with productivity; with water use efficiency specifically being positively correlated with growth at an alluvial terrace site, but negatively correlated with growth at an upland site. Tree height growth, leaf isotope composition (δ 13 C and δ 15 N), as well as leaf mass per area (LMA) exhibited the least plasticity across sites, while physiological gas exchange parameters and leaf nitrogen concentration exhibited the highest plasticity. Broadly across taxa, leaf carbon isotope ratios were correlated with intrinsic water use efficiency, and stomatal conductance was positively correlated with photosynthetic nitrogen use efficiency across sites, while leaf nitrogen isotope ratios exhibited contrasting relationships with leaf nitrogen concentration. Discussion: Overall, these results allow us to refine selections of productive genotypes based on site conditions and site-specific relationships with physiological parameters to better match Populus taxa with sites and landowner objectives.

bioenergy feedstocks↗

Integration of GOES Data for Solar Resource Assessment of the Contiguous United States

The National Solar Radiation Database (NSRDB), produced by the National Laboratory of the Rockies (NLR), provides high-resolution solar resource data for the contiguous United States (CONUS) using Geostationary Operational Environmental Satellite (GOES) East and West observations. This study evaluates the integration of multi-satellite data within the GOES-East/West overlap regions, where conventional longitude-based selection methods often produce an artificial boundary seam. Our results demonstrate that an advanced blending algorithm, which incorporates sun-satellite scattering angles and satellite viewing zenith angles, improves NSRDB accuracy and creates a spatially continuous dataset. Validation against ground-based irradiance measurements reveals reductions in both percentage error (PE) and normalized Root Mean Square Error (nRMSE), particularly in the central United States. The dynamical integration of multi-satellite data provides a robust foundation for more precise modeling of solar resource and improved spatiotemporal analysis of solar ramp across the CONUS.

14 SOLAR ENERGY↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Cropland abandonment between 1986 and 2018 across the United States: spatiotemporal patterns and current land uses

Knowing where and when croplands have been abandoned or otherwise removed from cultivation is fundamental to evaluating future uses of these areas, e.g. as sites for ecological restoration, recultivation, bioenergy production, or other uses. However, large uncertainties remain about the location and time of cropland abandonment and how this process and the availability of associated lands vary spatially and temporally across the United States. Here, we present a nationwide, 30 m resolution map of croplands abandoned throughout the period of 1986–2018 for the conterminous United States (CONUS). We mapped the location and time of abandonment from annual cropland layers we created in Google Earth Engine from 30 m resolution Landsat imagery using an automated classification method and training data from the U.S. Department of Agriculture Cropland Data Layer. Our abandonment map has overall accuracies of 0.91 and 0.65 for the location and time of abandonment, respectively. From 1986 to 2018, 12.3 (±2.87) million hectares (Mha) of croplands were abandoned across CONUS, with areas of greatest change over the Ogallala Aquifer, the southern Mississippi Alluvial Plain, the Atlantic Coast, North Dakota, northern Montana, and eastern Washington state. The average annual nationwide abandoned area across our study period was 0.51 Mha per year. Annual abandonment peaked between 1997 and 1999 at a rate of 0.63 Mha year –1 , followed by a continuous decrease to 0.41 Mha year –1 in 2009–2011. Among the abandoned croplands, 53% (6.5 Mha) changed to grassland and pasture, 18.6% (2.28 Mha) to shrubland and forest, 8.4% (1.03 Mha) to wetlands, and 4.6% (0.56 Mha) to non-vegetated lands. Of the areas that we mapped as abandoned, 19.6% (2.41 Mha) were enrolled in the Conservation Reserve Program as of 2020. Our new map highlights the long-term dynamic nature of agricultural land use and its relation to various competitive pressures and land use policies in the United States.

54 ENVIRONMENTAL SCIENCES↗

No evidence of Bartonella infections in host-seeking Ixodes scapularis and Ixodes pacificus ticks in the United States

Background. Bartonella spp. infect a variety of vertebrates throughout the world, with generally high prevalence. Several Bartonella spp. are known to cause diverse clinical manifestations in humans and have been recognized as emerging pathogens. These bacteria are mainly transmitted by blood-sucking arthropods, such as fleas and lice. The role of ticks in the transmission of Bartonella spp. is unclear. Methods. A recently developed quadruplex polymerase chain reaction (PCR) amplicon next-generation sequencing approach that targets Bartonella-specific fragments on gltA, ssrA, rpoB, and groEL was applied to test host-seeking Ixodes scapularis ticks (n=1641; consisting of 886 nymphs and 755 adults) collected in 23 states of the eastern half of the United States and Ixodes pacificus ticks (n=966; all nymphs) collected in California in the western United States for the presence of Bartonella DNA. These species were selected because they are common human biters and serve as vectors of pathogens causing the greatest number of vector-borne diseases in the United States. Results. No Bartonella DNA was detected in any of the ticks tested by any target. Conclusions. Owing to the lack of Bartonella detection in a large number of host-seeking Ixodes spp. ticks tested across a broad geographical region, our results strongly suggest that I. scapularis and I. pacificus are unlikely to contribute more than minimally, if at all, to the transmission of Bartonella spp.

59 BASIC BIOLOGICAL SCIENCES↗

An Updated Life Cycle Assessment of Utility-Scale Solar Photovoltaic Systems Installed in the United States

Given the high deployment targets for solar photovoltaics (PV) needed to meet U.S. decarbonization goals, and the limited carbon budget remaining to limit global temperature rise, accurate accounting of the energy-use and greenhouse-gas emissions over the life-cycle of PV systems is needed. In the United States, most PV systems are large utility-scale systems which use single-axis trackers and central inverters, which are not commonly examined in existing life-cycle assessment (LCA) literature. In this study, we present a cradle-to-grave LCA of a typical silicon U.S. utility PV (UPV) installation which is consistent with the utility system features documented in the annual NREL PV system cost benchmark reports. We analyze and present results for four main metrics: cumulative energy demand (CED), greenhouse gas (GHG) emissions, energy payback time (EPBT), and carbon payback time (CPBT). We consider six primary manufacturing options: three based on an imported PV module supply chain (comparing low-carbon imports, high-carbon imports, and average imports), and three based on a potential domestic PV module supply chain (comparing low-carbon U.S. regions, high-carbon U.S. regions, and average U.S. regions). These manufacturing options were then paired with installation locations to create six main cases: low-carbon options were installed in Phoenix (Arizona), high-carbon options were installed in Seattle (Washington), and average options were installed in Fredonia (Kansas). These locations were selected to represent a range of irradiance and grid mixes in the United States, in order to illustrate the likely range of EPBTs and CPBTs possible across the United States. For all six cases, a sensitivity analysis for end-of-life (EOL) handling was explored to capture current and future management options: landfilling, partial recycling, and high-quality recycling. For the purposes of this report, the benchmark system was defined to use an average imported supply chain with partial recycling, installed in Fredonia (Kansas). CED results show ratios at or below 0.1 MJ oil-eq /MJgenerated which demonstrates efficient use of primary energy resources (below a 1:1 ratio), and represents a slight improvement over previous results in literature. GHG emissions per kWh range from 10-36 g CO 2 e, which are consistent with or lower than previous results published by NREL and IEA-PVPS. We use a graphical approach for calculating EPBT and CPBT in this report, which improves upon methods typically used in literature by accounting for non-linearity and avoiding data quality issues associated with long-term projections. EPBT was determined to vary from 0.5 to 1.2 years, with a benchmark EPBT of 0.6 years; CPBT was shown to vary from 0.8 to 20 years, with benchmark CPBT of 2.1 years, which is lower than other estimates from recent literature (typically >2 years).

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global Ecosystem Dynamics Investigation (GEDI) Structural Verification Unit (SVU) Vibration Test

This presentation describes the vibration test campaign of the Structural Verification Unit for the Global Ecosystem Dynamics Investigation (GEDI) mission The Structural Verification Unit test campaign served multiple purposes including the qualification of the instrument primary structure, verification of the structure's stiffness, Aperture Control Mechanism assembly level verification, and validation of the control approach for protoflight instrument vibration testing. Testing included three axes of sine burst, random, and sine vibration excitation. This test sequence required a high number of response instrumentation sensors that included tri-axial accelerometers and tri-axial force gauges. Multiple response limiting methods that included acceleration, force, and moment measurements were used to ensure the safety of the flight hardware. The lessons and specific test details learned on the structural verification unit test campaign will reduce test risks for the upcoming instrument-level vibration tests.

Structural Verification Unit↗

Subseasonal-to-Seasonal Hindcast Skill Assessment of Ridging Events Related to Drought Over the Western United States

Persistent atmospheric ridging events centered near the western United States are associated with widespread precipitation deficits and meteorological drought. Due to the relatively low skill of- dynamical models in forecasting precipitation on subseasonal‐to‐seasonal (S2S) time scales across this region, forecasts of ridging are explored in this study as a potential bridge for early warning drought prediction. To assess skill, we evaluate deterministic and probabilistic S2S hindcasts (out to 6 week lead time) of ridging events and geopotential height anomalies over the western United States in five ensemble hindcast systems. Prediction skill for ridging events is shown to be highly variable across models. For some models, longer‐time‐averaged patterns of geopotential height anomalies across the first 6 weeks can be skillfully simulated, when evaluated probabilistically against climatology. The most skillful models show modest skill in forecasting above normal ridging occurrences at lead times of Weeks 3–4 and Weeks 5–6,with some sensitivity to the specific ridge location and method for determining skill. Using the European Centre for Medium‐Range Weather Forecasts (ECMWF) model as a case study, longer lead time forecast busts are shown to often occur under extended periods of highly active La Nina‐like tropical convection. Model errors at simulating these tropical convection features may have a disproportionately large impact and degrade downstream forecasts over the western United States. Despite the documented model shortcomings, our results highlight an opportunity to target skillful ridging forecasts from dynamical models for improving early warning drought forecasting at S2S lead times.

S2S↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

An Analysis of Future Wind Energy Resources and Cost Uncertainties Across the United States

Wind power is a growing source of energy generation that relies on complex global atmospheric and earth system processes. There has been evidence of reductions in average wind speeds over land in North America since the 1980s, and several models project that average wind speeds will continue to decrease. Concurrently, the cost of wind energy systems in the United States has been decreasing since around 2010, a trend also projected to continue. There is considerable uncertainty in these future projections, with quantitative estimates of future wind resource and system costs varying widely. To study this, we run wind energy models with possible future system costs, turbine designs, and meteorological inputs from multiple downscaled earth system models over the contiguous United States. Changes in mean annual energy production from 2000-2019 to 2040-2059 can be as high as +10% in South Texas or as low as -20% in Iowa. Larger turbines and moderate reductions in system costs can offset the largest projected decreases in wind resource, but much uncertainty remains in the extent to which wind resources will change and to what extent system costs can be reduced. An analysis of variance shows, in several states in the Midwest, uncertainty in future wind resources can influence the cost of wind energy nearly as much as uncertainty in future system costs.

17 WIND ENERGY↗

Lepton flavor violation by three units

The conservation of lepton flavor is a prediction of the Standard Model and is still an excellent approximate symmetry despite our observation of neutrino oscillations. Lepton flavor violation by one or two units has been discussed for decades, with several dedicated experiments exploring the vast model landscape but no discoveries so far. Here, we explore operators and processes that violate at least one lepton flavor by three units and identify testable signatures. In the Standard Model effective field theory, such operators already arise at mass dimension 7 and can be tested through their contributions to Michel parameters in leptonic decays. True neutrinoless charged-lepton flavor violation arises at mass dimension 10 and can realistically only be seen in the tau decay channels 𝜏 → $𝑒⁢𝑒⁢𝑒⁢\bar{𝜇}⁢\bar{𝜇}$ or 𝜏 → $𝜇⁢𝜇⁢𝜇\bar{𝑒}\bar{𝑒}$, for example in Belle II. Testable rates for these tau decays require light new particles and subsequently predict an avalanche of remarkably clean but so-far unconstrained collider signatures.

Feynman diagrams↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗