Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Automatic Reactor Control System (ARCS) Upgrade, version 2.0 for TREAT

The Transient REActor Test Facility (TREAT) recently underwent an upgraded to the Automatic Reactor Control System (ARCS). The purpose of the upgrade was to institute a new software architecture that is better suited for the programming environment, patched software bugs and applied two new segments for reactor control. This paper will focus on the new segments for reactor control. The two new control segments added to ARCS are called Generic Power and Generic Rods. The original version of ARCS provided only two power related functions, namely periods and ramps, that had to be spliced together to generate any power shape. The Generic Power segment allows the user to input data points to define the function and then the algorithm does its best to create the desired shape. The original ARCS program utilized two direct rod commands (i.e. open loop control), these were a rod stop and clip. A Generic Rod segment extends the ability of the computer to directly command any rod position. The functionality of these new segments was proven during the TREAT outage in 2024.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Application of automated measurement and verification to utility energy efficiency program data

Trustworthy savings calculations are critical to convincing regulators of both the cost-effectiveness of energy efficiency program investments and their ability to defer supply-side capital investments. Today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of energy efficiency programs. They also require time-consuming data acquisition. A spectrum of savings calculation approaches is used, with some relying more heavily on measured data and others relying more heavily on estimated, modeled, or stipulated data. The increasing availability of “smart” meters and devices that report near-real time data, combined with new analytical approaches to quantify savings, offers the potential to conduct M&V more quickly and at lower cost, with comparable or improved accuracy. Commercial energy management and information systems (EMIS) technologies are beginning to offer these ‘M&V 2.0’ capabilities, and program administrators want to understand how they might assist programs in quickly and accurately measuring energy savings. This paper presents the results of recent testing of the ability to use automation to streamline the M&V process. In this paper, we apply an automated whole-building M&V tool to historic data sets from energy efficiency programs to begin to explore the accuracy, cost, and time trade-offs between more traditional M&V, and these emerging streamlined methods that use high-resolution energy data and automated computational intelligence. For the data sets studied we evaluate the fraction of buildings that are well suited to automated baseline characterization, the uncertainty in gross savings that is due to M&V 2.0 tools’ model error, and indications of labor time savings, and how the automated savings results compare to prior, traditionally determined savings results. The results show that 70% of the buildings were well suited to the automated approach. In a majority of the cases (80%) savings and uncertainties for each individual building were quantified to levels above the criteria in ASHRAE Guideline 14. In addition the findings suggest that M&V 2.0 methods may also offer time-savings relative to traditional approaches. Lastly, we discuss the implications of these findings relative to the potential evolution of M&V, and pilots currently being launched to test how M&V automation can be integrated into ratepayer-funded programs and professional implementation and evaluation practice.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Cost of Saving Electricity Through Energy Efficiency Programs Funded by Utility Customers: 2009–2015

The average cost to utilities to save a kilowatt-hour (kWh) in the United States is 2.5 cents, according to the most comprehensive assessment to date of the cost performance of energy efficiency programs funded by electricity customers. These costs are similar to those documented earlier. Cost-effective efficiency programs help ensure electricity system reliability at the most affordable cost as part of utility planning and implementation activities for resource adequacy. Building on prior studies, Berkeley Lab analyzed the cost performance of 8,790 electricity efficiency programs between 2009 and 2015 for 116 investor-owned utilities and other program administrators in 41 states. The Berkeley Lab database includes programs representing about three-quarters of total spending on electricity efficiency programs in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility Green Tariff Programs in the U.S.: Overview and Opportunities for Cost Savings

Federal agencies may want to procure renewable energy from an off-site generator. Green tariffs allow large utility customers in traditionally regulated states to procure renewable energy from their utility through a special tariff for energy from a specific renewable energy project, typically through a long-term contract. Some of these green tariffs provide customers with cost savings. The webinar will explain how these tariffs are structured, how to evaluate cost savings potential and what agencies need to consider when examining this purchasing option.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Virginia Solar Pathways Project: Economic Study of Utility-Administered Solar Programs: Soft Costs, Community Solar, and Tax Normalization Considerations

This report presents economic considerations for solar development in support of the Virginia Solar Pathways Project (VSPP), an effort funded by the U.S. Department of Energy (DOE) SunShot Initiative that seeks to develop a collaborative utility-administered solar strategy for the Commonwealth of Virginia. The results presented are intended to be considered alongside the results of other studies conducted under the VSPP that evaluate the impacts of solar energy on the electric distribution, transmission, and generation systems in Virginia.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Cost of Saving Electricity: A Multi-Program Cost Curve for Programs Funded by U.S. Utility Customers

This study analyzed the cost performance of electricity efficiency programs implemented by 116 investor-owned utilities between 2009 and 2015 in 41 states, representing about three-quarters of the total spending on U.S. efficiency programs. We applied our typology to characterize efficiency programs along several dimensions (market sector, technology, delivery approach, and intervention strategy) and report the costs incurred by utilities and other program administrators to achieve electricity savings as a result of the programs. Such cost performance data can be used to compare relative costs of different types of efficiency programs, evaluate efficiency options alongside other electricity resources, benchmark local efficiency programs against regional and national cost estimates, and assess the costs of meeting state efficiency policies. The savings-weighted average cost of saved electricity for the period was $0.025/kilowatt-hour (kWh). The cost of saved electricity for programs that targeted residential customers was $0.021/kWh, compared to $0.025/kWh for programs for commercial and industrial customers. Ultimately, we developed an aggregate program savings “cost curve” for the actual electricity efficiency resource during the period that provides insights into the relative costs of various types of efficiency programs and the savings contribution of each program type to the efficiency resource at a national level.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Assurance Planning Guide for Utility Energy Service Contracts: 2025 Edition

Administered by the U.S. Department of Energy's (DOE) Federal Energy Management Program (FEMP), the Utility Program has fostered collaboration among federal agencies and their serving utilities for more than 25 years. The Utility Program supports agencies using Utility Energy Service Contracts (UESCs), a well-developed, effective contracting vehicle that enable the latest approaches to cost-effective energy management at federal sites. Federal agencies have successfully used UESCs to award over 2,000 energy and water efficiency and renewable energy projects, investing approximately $\$$2.8 billion in furthering the Federal Government's efforts to reduce energy intensity. Authorized by 42 U.S. Code section 8256 (10 U.S. Code section 2913 for the Department of Defense), a UESC is a limited-source acquisition between a federal agency and an eligible serving utility for energy management services that generate savings from the implementation of energy- and water -conservation measures (collectively referred to as ECMs), with 42 U.S. Code section 8287 (Defense Federal Acquisition Regulation Supplement, Part 241), providing the term of a UESC, which may extend up to 25 years. Through a UESC, the utility partner assesses designs, and implements the desired ECMs - which can range from lighting retrofits and renewable energy systems, to combined heat and power plants or other technologies and strategies, and may provide financing for the project. The agency may use any combination of appropriations and third-party financing to pay for the project, providing useful flexibility. There is no limit to the project size, big or small, that can be implemented using a UESC. To assist agencies implementing a UESC, FEMP has developed a Utility Energy Service Contract Guide and this companion guidance document to help agencies and their utility partners better understand the best practices for to ensure UESCs continue to perform and generate savings throughout their performance period. These best practices utilize a combination of effective project management, communication, documentation, and a detailed Performance Assurance Plan. This plan is a project specific set of actionable protocols that define important tasks and responsibilities throughout the contract term and reflects the site conditions, complexities, agency capabilities, and operating and maintaining planned ECMs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Vicinity Property Assessments at Formerly Utilized Sites Remedial Action Program Project Sites in the New York District - 13420

The Formerly Utilized Sites Remedial Action Program (FUSRAP) has addressed sites across the nation for almost 4 decades. Multiple stake holder pressures, multiple regulations, and process changes occur over such long time periods. These result in many challenges to the FUSRAP project teams. Initial FUSRAP work was not performed under Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Records of Decision (ROD). The ROD identifies the remedy decision and ultimately the criteria to be used to release a site. Early FUSRAP projects used DOE Orders or the Uranium Mill Tailings Radiation Control Act (UMTRCA) standards. Under current RODs, regulations may differ, resulting in different cleanup criteria than that used in prior Vicinity Property (VP) remediation. The USACE, in preparation for closeout of Sites, conducts reviews to evaluate whether prior actions were sufficient to meet the cleanup criteria specified in the current ROD. On the basis of these reviews, USACE has conducted additional sampling, determined that prior actions were sufficient, or conducted additional remediation consistent with the selected remedy in the ROD. As the public pressures, regulations, and processes that the FUSRAP encounters continue to change, the program itself continues to evolve. Assessment of VPs at FUSRAP sites is a necessary step in the life cycle of our site management. (authors)

54 ENVIRONMENTAL SCIENCES↗

The Program Administrator Cost of Energy Saved for Utility Customer-Funded Energy Efficiency Programs

End-use energy efficiency is increasingly being relied upon as a resource for meeting electricity and natural gas utility system needs within the United States. There is a direct connection between the maturation of energy efficiency as a resource and the need for consistent, high-quality data and reporting of efficiency program costs and impacts. To support this effort, LBNL initiated the Cost of Saved Energy Project (CSE Project) and created a Demand-Side Management (DSM) Program Impacts Database to provide a resource for policy makers, regulators, and the efficiency industry as a whole.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating the Drivers of the Cost of Saved Electricity in Utility Customer-Funded Energy Efficiency Programs

Energy efficiency programs funded by utility customers provide an electricity resource in most U.S. states, but their scale and cost of saving electricity varies significantly by state. In this paper, we explore the drivers of the cost of saved electricity in these programs with an econometric model and nearly a decade of data reported by efficiency program administrators. We found strong evidence for economies of scale and weak evidence for diseconomies of scale, which suggests that states with low levels of efficiency savings relative to retail sales can increase the size of their efficiency programs without large increases to the cost of saved electricity. We discuss examples of energy efficiency forecasting and potential modeling in light our econometric analysis and identify methodological improvements relevant to utilities and grid operators. This paper provides insights into the economics of customer-funded efficiency programs that will support regulators, utilities, and policymakers to utilize energy efficiency as a resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Winners are not keepers: Characterizing household engagement, gains, and energy patterns in demand response using machine learning in the United States

Demand-response programs can help utilities manage rapidly evolving electric grids, but these programs are subject to the complexities of human behavior. This paper explores a novel method for uncovering heterogeneity in households. In this work, we use a machine-learning method known as a Conditional Inference Tree (c-tree) algorithm to categorize households based on their energy behavior characteristics collected via smart meters, and explore how this translates through into heterogeneity in their real-world response to a DR program. Using data from randomized controlled trial, we generate estimates of the changes in energy use caused by the program within each household group. Our results show that the c-tree approach differentiates households by their energy-use characteristics in a way that increases the spread in enrollment rates and critical peak reduction among household groups, compared with the spreads achieved via several conventional segmentation methods. Thus, the c-tree analysis enables the most tailored targeting of major potential energy savers and could provide the greatest increase in cost-effectiveness of household recruitment into DR programs. Our results also offer fresh insights into the relationships between household energy behavior characteristics – such as peak energy use and “structural winningness” (the ability to save money under a DR program without changing energy-use behaviors) – and household decisions about enrolling in DR programs and reducing energy use. Our research also demonstrates the potential of smart meter data, combined with machine learning and econometric methods, to provide significant value to utilities, program implementers, researchers, and other stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishing Building-Level Energy Goals in Procurement Documents: Lessons Learned from Pilot Utility and Portfolio Projects

Encouraging commercial building owners to set measurable energy goals before design begins can drive design and contractor teams to develop innovative energy efficiency solutions within conventional building budgets. A federal building owner piloted this technique and created a large-scale zero energy office building on a budget comparable to local market construction rates. The successes and lessons learned from this performance-based procurement project formed the basis of an expanded program using utilities as the outreach channel to replicate the approach. The utilities delivered incentive-based offerings to focus building owners on the whole building rather than on individual building components and systems. In addition, a ripple effect was evident, with individual building owners as well as owners of multiple-building portfolios adopting the techniques, sometimes with variations, but always maintaining the same core principles. The original performance-based procurement process and its successful implementation in a federal building project informed all these efforts. Those successes and lessons learned demonstrate that the approach can be adapted to utility programs with some variation and is a powerful tool for engaging building owners as they make critical design decisions that impact energy performance over the life of the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishing Building-Level Energy Goals in Procurement Documents: Lessons Learned from Pilot Utility and Portfolio Projects: Preprint

Encouraging commercial building owners to set measurable energy goals before design begins can drive design and contractor teams to develop innovative energy efficiency solutions within conventional building budgets. A federal building owner piloted this technique and created a large-scale zero energy office building on a budget comparable to local market construction rates. The successes and lessons learned from this performance-based procurement project formed the basis of an expanded program using utilities as the outreach channel to replicate the approach. The utilities delivered incentive-based offerings to focus building owners on the whole building rather than on individual building components and systems. In addition, a ripple effect was evident, with individual building owners as well as owners of multiple-building portfolios adopting the techniques, sometimes with variations, but always maintaining the same core principles. The original performance-based procurement process and its successful implementation in a federal building project informed all these efforts. Those successes and lessons learned demonstrate that the approach can be adapted to utility programs with some variation and is a powerful tool for engaging building owners as they make critical design decisions that impact energy performance over the life of the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Who is participating in residential energy efficiency programs? Exploring demographic and other household characteristics of participants in utility customer-funded energy efficiency programs

In addition to benefiting all customers by reducing the total electric system cost, utility customer-funded energy efficiency programs provide direct benefits to the participants. Understanding the current demographic and household characteristics of participants will help assess the extent of inequities in program participation and figure out what characteristics need to be targeted to achieve equitable outcomes. This report describes how 11 demographic and household characteristics including income, race and ethnicity, and education affect participation in residential utility customer-funded energy efficiency programs. It compiles previous work on this topic and adds new primary analysis of four datasets with different levels of detail from the Residential Energy Consumption Survey (RECS), two New England states, and a Midwestern state.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗