Search NASA⌕ Search

SEARCH · Search NASA

Results for “vanes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Measured and calculated wall temperatures on air-cooled turbine vanes with boundary layer transition

Convection cooled turbine vane metal wall temperatures experimentally obtained in a hot cascade for one vane design were compared with wall temperatures calculated with TACT1 and STAN5 computer codes which incorporated various models for predicting laminar-to-turbulent boundary layer transition. Favorable comparisons on both vane surface were obtained at high Reynolds number with only one of these transition models. When other models were used, temperature differences between calculated and experimental data obtained at the high Reynolds number were as much as 14 percent in the separation bubble region of the pressure surface. On the suction surface and at lower Reynolds number, predictions and data unsatisfactorily differed by as much as 22 percent. Temperature differences of this magnitude can represent orders of magnitude error in blade life prediction.

Liebert, C. H.↗

JT90 thermal barrier coated vanes

The technology of plasma sprayed thermal barrier coatings applied to turbine vane platforms in modern high temperature commercial engines was advanced to the point of demonstrated feasibility for application to commercial aircraft engines. The three thermal barrier coatings refined under this program are zirconia stabilized with twenty-one percent magnesia (21% MSZ), six percent yttria (6% YSZ), and twenty percent yttria (20% YSZ). Improvement in thermal cyclic endurance by a factor of 40 times was demonstrated in rig tests. A cooling system evolved during the program which featured air impingement cooling for the vane platforms rather than film cooling. The impingement cooling system, in combination with the thermal barrier coatings, reduced platform cooling air requirements by 44% relative to the current film cooling system. Improved durability and reduced cooling air requirements were demonstrated in rig and engine endurance tests. Two engine tests were conducted, one of 1000 cycles and the other of 1500 cycles. All three coatings applied to vanes fabricated with the final cooling system configuration completed the final 1500 cycle engine endurance test. Results of this test clearly demonstrated the durability of the 6% YSZ coating which was in very good condition after the test. The 21% MSZ and 20% YSZ coatings had numerous occurrences of significant spalling in the test.

Sheffler, K. D.↗

Axial vane-type swirler performance characteristics

The performance of an axial vane-type swirler was investigated to aid in computer modeling of gas turbine combustor flowfields and in evaluation of turbulence models for swirling confined jet flow. The swirler studied is annular with a hub-to-swirler diameter ratio of 0.25 and ten adjustable vanes of pitch-to-chord ratio 0.68. Measurements of time-mean axial, radial, and tangential velocities were made at the swirler exit plane using a five-hole pitot probe technique with computer data reduction. Nondimensionalized velocities from both radial and azimuthal traverses are tabulated and plotted for a range of swirl vane angles phi from 0 to 70 degrees. A study was done of idealized exit-plane velocity profiles relating the swirl numbers S and S' to the ratio of maximum swirl and axial velocities for each idealized case, and comparing the idealized swirl numbers with ones calculated from measured profiles.

Sander, G. F.↗

Measurements of heat transfer distribution over the surfaces of highly loaded turbine nozzle guide vanes

The results of an experimental study of aerodynamic (surface velocity) and heat transfer distributions over the surfaces of two different, highly loaded, low-solidity contemporary turbine vane designs are presented. The aerodynamic configurations of the two vanes were carefully selected to emphasize fundamental differences in the character of the solution surface pressure distributions and the consequent effect on surface heat transfer distributions. The experimental measurements were made in moderate-temperature, three-vane cascades under steady-state conditions. The principal independent parameters (Mach number, Reynolds number, turbulence intensity, and wall-to-gas temperature ratio) were varied over ranges consistent with actual engine operation, and the heat matrix was structured to provide an assessment of the independent influence of each parameter. These measurements are intended to serve as verification data for a parallel analytical code development effort. The results of this parallel effort are briefly reviewed, and the principal conclusions to date are summarized.

Nealy, D. A.↗

Reduction of Vane Noise in Wind-Tunnel Nozzles

Vane-induced noise reduced by adhering thin layer of porous material such as foam to downwind surface of vanes, particularly near sharp trailing edges, to prevent occurrence of edge tones. Other modifications made to aerodynamically streamline vane structure were rounding leading edges and smoothly fairing trailing edges. Boundary layer trip applied to leading edge to prevent laminar tone shedding from trailing edge.

Martin, R. M.↗

Noise radiation directivity from a wind-tunnel inlet with inlet vanes and duct wall linings

The acoustic radiation patterns from a 1/15th scale model of the Ames 80- by 120-Ft Wind Tunnel test section and inlet have been measured with a noise source installed in the test section. Data were acquired without airflow in the duct. Sound-absorbent inlet vanes oriented parallel to each other, or splayed with a variable incidence relative to the duct long axis, were evaluated along with duct wall linings. Results show that splayed vans tend to spread the sound to greater angles than those measured with the open inlet. Parallel vanes narrowed the high-frequency radiation pattern. Duct wall linings had a strong effect on acoustic directivity by attenuating wall reflections. Vane insertion loss was measured. Directivity results are compared with existing data from square ducts. Two prediction methods for duct radiation directivity are described: one is an empirical method based on the test data, and the other is a analytical method based on ray acoustics.

Soderman, P. T.↗

Vibration-Free Vanes Direct Cryogenic Flow

Upstream fluid-dynamic surface prevents oscillations. Simple structural addition to liquid-oxygen manifold prevents vibration and allows increased flow. T-shaped manifold uses vanes to distribute liquid oxygen. Far from vanes, spoiler suppresses vibrations caused by unstable dynamic coupling between flow and elasticity of vanes.

Rao, Gadicherla V. R.↗

Time-averaged aerodynamic loads on the vane sets of the 40- by 80-foot and 80- by 120-foot wind tunnel complex

Time-averaged aerodynamic loads are estimated for each of the vane sets in the National Full-Scale Aerodynamic Complex (NFAC). The methods used to compute global and local loads are presented. Experimental inputs used to calculate these loads are based primarily on data obtained from tests conducted in the NFAC 1/10-Scale Vane-Set Test Facility and from tests conducted in the NFAC 1/50-Scale Facility. For those vane sets located directly downstream of either the 40- by 80-ft test section or the 80- by 120-ft test section, aerodynamic loads caused by the impingement of model-generated wake vortices and model-generated jet and propeller wakes are also estimated.

Aoyagi, Kiyoshi↗

Flow-induced vibrations of the SSME LOX inlet tee vanes

This paper describes the results of a program initiated to identify the cause and the mechanism of 4-kHz vibrations of the Space Shuttle main engine's (SSME's) LOX inlet tee, which were revealed in 17 percent of the SSMEs during ground tests. The results of the engines' inspection, structural analyses, computational fluid dynamics studies, literature reviews, expert consultations, and laboratory testings identified the probable cause of the 4-kHz vibrations being related to the fact that the walls of some tees were thinner than in the mojority of tees, resulting in less stiff structures. The mechanism of the vibrations was identified as vortex shedding in combination with a structural coupling with the thrust cone, which increased the vane mobility, which, in turn, aggravated the fluid coupling with the thrust cone. As a result, the vane mobility was increased, aggravating the fluid coupling with the vanes. An internal modification was developed and was successfully demonstrated on an engine that had previously exhibited a 4-kHz problem.

O'Connor, G. M.↗

The K-Gill - A twin propeller-vane anemometer for measurements of atmospheric turbulence

A twin propeller-vane anemometer developed at the University of British Columbia was successfully used for unattended measurement of atmospheric turbulence over extended periods of time during moderate to high winds in the presence of sea spray. In this paper, a new design in twin propeller-vane anemometers is introduced. The instrument consists of two Gill anemometers mounted on a vane. The propeller shafts, one pointing up and the other pointing down, make an angle of 45 deg with the horizontal (hence, the name K-Gill). In addition to the desirable characteristics of the earlier design the K-Gill has symmetry, so that updraft and downdraft winds are measured with equal sensitivity. An algorithm for obtaining the vertical and downstream horizontal components of the wind velocity is described. Various sources of error and their magnitudes are discussed.

Atakturk, Serhad S.↗

The effectiveness of vane-aileron excitation in the experimental determination of flutter speed by parameter identification

The effectiveness of aerodynamic excitation is evaluated analytically in conjunction with the experimental determination of flutter dynamic pressure by parameter identification. Existing control surfaces were used, with an additional vane located at the wingtip. The equations leading to the identification of the equations of motion were reformulated to accommodate excitation forces of aerodynamic origin. The aerodynamic coefficients of the excitation forces do not need to be known since they are determined by the identification procedure. The 12 degree-of-freedom numerical example treated in this work revealed the best wingtip vane locations, and demonstrated the effectiveness of the aileron-vane excitation system. Results from simulated data gathered at much lower dynamic pressures (approximately half the value of flutter dynamic pressure) predicted flutter dynamic pressures with 2-percent errors.

Nissim, Eli↗

Time-dependent Navier-Stokes computations for flow-induced vibrations of vanes

Flows over two curved vane configurations were computed using a time-accurate compressible Navier-Stokes flow model. One configuration showed the presence of strong flow-induced vibrations at Strouhal numbers near 0.19 and 0.38 for bending and torsional excitation. In the other configuration, a simple modification reduced both types of response. Laminar flows were analyzed for the effects of flow-induced vibrations, and flow fields were solved for a rigid vane and a vane undergoing forced vibrations at prescribed amplitude and frequency simulating vibration response to a coupled vortex-shedding/elastic motion feedback cycle.

Liu, B. L.↗

The effect of swirl recovery vanes on the cruise noise of an advanced propeller

The SR-7A propeller was acoustically tested with and without downstream swirl recovery vanes to determine if any extra noise was caused by the interaction of the propeller wakes and vortices with these vanes. No additional noise was observed at the cruise condition over the angular range tested. The presence of the swirl recovery vanes did unload the propeller and some small peak noise reductions were observed from lower propeller loading noise. The propeller was also tested alone to investigate the behavior of the peak propeller noise with helical tip Mach number. As observed before on other propellers, the peak noise first rose with helical tip Mach number and then leveled off or decreased at higher helical tip Mach numbers. Detailed pressure-time histories indicate that a portion of the primary pressure pulse is progressively cancelled by a secondary pulse as the helical tip Mach number is increased. This cancellation appears to be responsible for the peak noise behavior at high helical tip Mach numbers.

Dittmar, James H.↗

The effect of swirl recovery vanes on the cruise noise of an advanced propeller

The SR-7A propeller was acoustically tested with and without downstream swirl recovery vanes to determine if any extra noise was caused by the interaction of the propeller wakes and vortices with these vanes. No additional noise was observed at the cruise condition over the angular range tested. The presence of the swirl recovery vanes did unload the propeller and some small peak noise reductions were observed from lower propeller loading noise. The propeller was also tested alone to investigate the behavior of the peak propeller noise with helical tip Mach number. As observed before on other propellers, the peak noise first rose with helical tip Mach number and then leveled off or decreased at higher helical tip Mach numbers. Detailed pressure-time histories indicate that a portion of the primary pressure pulse is progressively cancelled by a secondary pulse as the helical tip Mach number is increased. This cancellation appears to be responsible for the peak noise behavior at high helical tip Mach numbers.

Dittmar, James H.↗

Ames 40 X 80/80 X 120 Foot Wind Tunnel: Turning Vanes Design

A number of different turning vanes are designed for the NASA Ames wind tunnel. Computer codes are used to design and analyze the turning vanes to insure that they comply with their individual constraints. The presentation is given in viewgraph format and displays pressure coefficients for the different turning vanes as well as loss coefficients versus inlet flow angles.

Sanz, J.↗

Performance of a vane driven-gear pump

Given here are the results of a test conducted in a wind tunnel on the performance of a vane-driven gear pump used to pump gasoline upward into a small tank located within the upper wing from which it flows by gravity to the engine carburetor. Information is given on the efficiency of the pump, the head resistance of the vanes, the performance and characteristics of the unit with and without housing about the vanes, the pump performance when motor driven, and resistance and power characteristics.

Heald, R H↗

Investigation of Blade-row Flow Distributions in Axial-flow-compressor Stage Consisting of Guide Vanes and Rotor-blade Row

A 30-inch tip-diameter axial-flow compressor stage was investigated with and without rotor to determine individual blade-row performance, interblade-row effects, and outer-wall boundary-layer conditions. Velocity gradients at guide-vane outlet without rotor approximated design assumptions, when the measured variation of leaving angle was considered. With rotor in operation, Mach number and rotor-blade effects changed flow distribution leaving guide vanes and invalidated design assumption of radial equilibrium. Rotor-blade performance correlated interpolated two-dimensional results within 2 degrees, although tip stall was indicated in experimental and not two-dimensional results. Boundary-displacement thickness was less than 1.0 and 1.5 percent of passage height after guide vanes and after rotor, respectively, but increased rapidly after rotor when tip stall occurred.

COMPRESSORS - AXIAL FLOW↗

Evaluation of Some Slow-wave Vane Structures for Aminiature Traveling-wave Tube at 30 Ghz

The dispersion characteristics of six vane type slow wave structures were experimentally measured near 1 GHz to determine applicability in an electrostatically focused 30 GHz miniature traveling wave tube (TWT). From the measured results, the trapezoidal vane structure appeared to be the most promising exhibiting an interaction impedance equal to 337.9 ohms at beta(L)/pi equal to 0.3. A 30 GHz trapezoidal vane structure with coupling irises was fabricated using electrical discharge machining (EDM). This structure, however, was too lossy for a short electrostatically focused tube, but several of the structures are amenable to a tube with permanent magnetic focusing.

Kavanagh, Frank↗