Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Space-Time Finite Element Tensor Network Approach for the Time-Dependent Convection–Diffusion–Reaction Equation with Variable Coefficients

In this paper, we present a new space-time Galerkin-like method, where we treat the discretization of spatial and temporal domains simultaneously. This method utilizes a mixed formulation of the tensor-train (TT) and quantized tensor-train (QTT) (please see Section Tensor-Train Decomposition), designed for the finite element discretization (Q1-FEM) of the time-dependent convection–diffusion–reaction (CDR) equation. We reformulate the assembly process of the finite element discretized CDR to enhance its compatibility with tensor operations and introduce a low-rank tensor structure for the finite element operators. Recognizing the banded structure inherent in the finite element framework’s discrete operators, we further exploit the QTT format of the CDR to achieve greater speed and compression. Additionally, we present a comprehensive approach for integrating variable coefficients of CDR into the global discrete operators within the TT/QTT framework. The effectiveness of the proposed method, in terms of memory efficiency and computational complexity, is demonstrated through a series of numerical experiments, including a semi-linear example.

convection–diffusion–reaction equation↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines: Preprint

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be timeconsuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the towerbase damage equivalent loading and better tracking of the rated generator speed and power.

closed-loop control↗

Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

42 ENGINEERING↗

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chiral Kirigami for Bend‐Tolerant Reconfigurable Hologram with Continuously Variable Chirality Measures

Abstract Despite the commonality of static holograms, the holography with multiple information layers and reconfigurable grey‐scale images at communication frequencies remain a confluence of scientific challenges. One well‐known difficulty is the simultaneous modulation of phase and amplitude of electromagnetic wavefronts with a high modulation depth. A less appreciated challenge is scrambling of the information and images with hologram bending. Here, this work shows that chirality‐guided pixelation of plasmonic kirigami sheets enables tunable multiplexed holography at terahertz (THz) frequencies. The convex and concave structures with slanted Au strips exhibit gradual variations in geometries facilitating modulation of light ellipticity reaching 40 deg. Real‐time switching of 3D images of the letter “ M ” and the Mona Lisa demonstrates the possibility of complex grey‐scale information content and importance of continuously variable mirror asymmetry. Microscale chirality measures of each pixel experiences little change with bending while retaining controllable reconfigurability upon stretching, which translates to remarkable resilience of chiral holograms to bending. Simplicity of their design with local chirality measures opens the door to information technologies with fault‐tolerant THz encryption, wearable holographic devices, and new communication technologies.

36 MATERIALS SCIENCE↗

Degassing fluxes in a temperate hydropower reservoir predictable by deep‐water dissolved oxygen but highly sensitive to discharge variability

Hydropower reservoirs contribute to methane (CH 4 ) and carbon dioxide (CO 2 ) emissions, like all aquatic ecosystems. Unique to hydropower reservoirs are degassing emissions that occur when deep-water intakes move water with high CH 4 and CO 2 concentrations through turbines, leading to the release of these gases. However, few studies from hydropower reservoirs have measured seasonal variability and drivers of degassing fluxes, especially in temperate systems. We measured monthly degassing emissions in temperate Douglas Reservoir (Tennessee, USA) from 2023 to 2024. We found that degassing fluxes were highest in the summertime, and deep-water CH 4 and CO 2 concentrations were predictable by deep-water dissolved oxygen (DO) concentrations. Degassing emissions accounted for 37–62% of annually estimated CH 4 emissions, outweighing ebullitive emissions during summer months. We highlight the value of using DO data to estimate deep-water CH 4 and CO 2 concentrations and degassing fluxes at higher temporal resolution to improve annualization and extrapolation of reservoir degassing emissions at broader scales.

Pilla, Rachel M. [Oak Ridge National Laboratory (O↗

Measurement of the dineutrino system kinematic variables in dileptonic top quark pair production in proton-proton collisions at $\sqrt{s}=13$ TeV

Differential top quark pair production cross sections are measured in the dilepton final states e + e − , μ + μ − , and e ± μ ∓ , as a function of kinematic variables of the two-neutrino system: the transverse momentum $p^{vv}_{\textrm{T}}$ of the dineutrino system, the minimum distance in azimuthal angle between $\vec{p}^{vv}_{\textrm{T}}$ and leptons, and in two dimensions in bins of both observables. The measurements are performed using CERN LHC proton-proton collisions at $\sqrt{s}=13$ TeV, recorded by the CMS detector between 2016 and 2018, corresponding to an integrated luminosity of 138 fb −1 . The measured cross sections are unfolded to the particle level using an unregularized least squares method. Results are compared with predictions by the standard model of particle physics, and found to be in agreement with theoretical calculations as well as Monte Carlo simulations.

Hadron-Hadron Scattering↗

$t\overline{t}b\overline{b}$ at NLO precision in a variable flavor number scheme

Top-quark pair production in association with two $b$-jets is computed at next-to-leading order QCD precision, including effects of the $b$-quark mass, and matched to a $t\overline{t}$+jets simulation in a variable flavor number scheme. The Monte Carlo realization of this method, called fusing, consistently embeds the four-flavor calculation in a particle-level event generator. As a first phenomenological application, we present observables relevant to the data-driven estimation of irreducible backgrounds to $t\overline{t}H$ -production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impacts of year-to-year weather variability and inter-panel spacing on agrivoltaic crop yields in Massachusetts

Deployment of utility-scale solar power plants could lead to agricultural land-use changes. Agrivoltaics, a dual land use combining solar and agriculture on the same land, can provide multiple environmental benefits, including improving soil quality and water use efficiency. The body of agrivoltaic field data is still growing, and crop responses to different solar configurations under different local climates are highly varied. We investigate the impact of adding spacing between adjacent solar panels in a fixed-tilt system to improve light diffusion to crops. For four crops (broccoli, peppers, kale, Swiss chard) grown across 3 years in an agrivoltaic system in Massachusetts, we found that only kale had a linearly increasing trend as the inter-panel spacing increased from 0.6 m to 1.5 m (2 ft to 5 ft). However, there were significant year-to-year differences in the yield of agrivoltaic versus control fields. Agrivoltaic and full sun fields produced equivalent yields in a hot, dry year, whereas the full-sun control beds produced more salable yield for all four crops in a warm, wet year. This demonstrates variability of agricultural outcomes and the need for more multi-year studies to ensure agrivoltaic impacts are not under- or overestimated.

14 SOLAR ENERGY↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

The environmental impact of hydropower: a systematic review of the ecological effects of sub-daily flow variability on riverine fish

Hydropower can help facilitate power grid decarbonization because it can respond to short-term changes in power demand and is comparatively more reliable than intermittent wind and solar. However, flexible hydropower operations can create rapid and abnormal fluctuations in downstream flow conditions, which can negatively impact aquatic ecosystems. Accordingly, we conducted a systematic review on the ecological effects of hydropower-driven sub-daily flow variability (SDFV) on riverine fishes. We reviewed and synthesized 109 articles relevant to fish-SDFV relationships from seven sources, most of which focused on Salmonids in North America and northern and western Europe and were published in the last 15 years. We found strong agreement in the literature that SDFV increases fish stranding risk, destabilizes habitat, and decreases production and diversity. We found moderate agreement that SDFV interrupts fish reproduction, increases or has no impact on condition, and prompts or discourages movement depending on local channel conditions. We found little to no agreement for relationships between SDFV and mortality, physiology, and behavior. The effects of SDFV on riverine fish ecology are intertwined in the complex suite of biotic and abiotic characteristics that structure aquatic ecosystems and are highly site-, species-, and life stage-specific. Assessments of the impact of SDFV on fish ecology should first characterize local habitat and channel quality and fish community composition to identify specific, measurable ecological outcomes to sustain or enhance, and then design mitigation strategies tailored to those ecological objectives.

13 HYDRO ENERGY↗

Assessing Climate Change-Induced Variability in Generation Potential and Droughts of Renewable Energy Systems in India

Solar photovoltaic (PV) and wind energy systems are crucial for decarbonizing the electricity sector and achieving climate goals. However, these systems are weather-dependent, and ignoring the potential changes in their generation levels due to climate change could compromise achieving climate targets and meeting future electricity demand. This study evaluates the impact of climate change on the generation potential of wind and solar PV systems in India for three future periods, 2030 (2021-2040), 2050 (2041-2060), and 2070 (2061-2080) compared to the baseline year 2000 (1991-2010), under three emission scenarios: SSP245, SSP370, and SSP585. Solar PV generation levels consistently decline (up to 10 %) across all regions and scenarios. Wind energy shows more pronounced variability (-20 % to 30 %). The South and Southeastern regions of India show improvements in wind potential across all scenarios and time periods. This study also investigated the projected changes in the generation droughts of both energy systems. For solar PV, drought days increase across most regions (exceeding 500 days under SSP370 across the 20-year period). In contrast, wind energy sees a reduction in drought days, especially in parts of South and Southeast India (declines exceeding 50 days across different scenarios). For both energy systems, the patterns of generation drought and generation potential are similar, and indicate that Western and Northern India may be less favorable for the future expansion of solar PV and wind energy, respectively. These results highlight the need to account for the potential impacts in future capacity planning.

14 SOLAR ENERGY↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Enhancement of oxidative dehydrogenation over cerium-doped nickel niobium catalysts and analysis of batch-to-batch variability

Nickel based catalysts are inexpensive and efficient for use in the oxidative dehydrogenation of ethane. NiO doped with niobium and cerium shows increased ethylene production. Small amounts of Ce doped onto a NiNb catalyst led to increased Ni activity. The catalyst that had the highest ethylene production rate per g of catalyst had 1 atom% Ce, 86 at% Ni, and 13 at% Nb (1CeNiNb) while, if surface area is incorporated into the calculation, the catalyst that had the highest ethylene production rate per m 2 was the 0.5CeNiNb catalyst. The ethylene production rates of these Ce-containing catalysts are 27 %-127 % higher than those with NiNb alone previously reported in the literature. Here, to fully understand how cerium affects the NiNb catalyst, the Ce content and effect on active sites has been fully characterized over multiple batches. In doing this, light has been shed on batch-to-batch variability. Characterization techniques such as powder X-ray diffraction, hydrogen temperature programmed reduction, X-ray photoelectron spectroscopy, synchrotron X-ray absorption spectroscopy, and methanol adsorption were used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sylvester-preconditioned adaptive-rank implicit time integrators for advection-diffusion equations with variable coefficients

Here, we consider the adaptive-rank integration of multi-dimensional time-dependent advection-diffusion partial differential equations (PDEs) with variable coefficients. We employ a standard finite-difference method for spatial discretization coupled with high-order diagonally implicit Runge-Kutta temporal schemes. The discrete equation is a generalized Sylvester equation (GSE), which we solve with a projection-based adaptive-rank algorithm structured around two key strategies: (i) constructing dimension-wise subspaces using a novel atypical extended Krylov strategy, and (ii) efficiently solving the basis coefficient matrix with a preconditioned GMRES solver. The low-rank decomposition is performed in 2D using SVD and with high-order SVD (HOSVD) in 3D to represent the tensor in a compressed Tucker format. For d-dimensional problems (here, d = 2 or 3), the computational complexity and memory storage of the approach are found numerically to scale as and $\mathscr{O}(Nr^2) + \mathscr{O} (r^{d+1})$ and $\mathscr{O}(Nr) + \mathscr{O} (r^{d})$, respectively, with the one-dimensional resolution and the maximal rank during the Krylov iteration (which we find to be largely independent of on our numerical examples). We present numerical examples that illustrate the advertised properties of the algorithm.

97 MATHEMATICS AND COMPUTING↗

Variable rate neural compression for sparse detector data

Particle colliders produce data at extraordinary rates, posing major challenges for transmission and storage. High-throughput compression algorithms are therefore essential. In the sPHENIX experiment taking data at the Relativistic Heavy Ion Collider, a time projection chamber records three-dimensional (3D) particle trajectories that are highly sparse, making conventional learning-free lossy compression ineffective. Convolutional neural networks have surpassed traditional methods in compression ratio and accuracy. However, they fail to exploit sparsity for efficiency. To address these gaps, we present BCAE-VS, a bicephalous convolutional autoencoder with variable compression ratio for sparse data, which adapts compression to input complexity through key-point identification and sparse convolution. BCAE-VS achieves higher accuracy and compression ratios than prior neural approaches while being orders of magnitude smaller. Moreover, its throughput increases with sparsity—a property not observed in other methods. Although it was developed for collider experiments, BCAE-VS readily extends to other sparse data domains, such as light detection and ranging (LiDAR) sensing and 3D microscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗