Search NASA⌕ Search

SEARCH · Search NASA

Results for “variational method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Few-nucleon matrix elements in pionless effective field theory in a finite volume

Here, pionless effective field theory in a finite volume (FVEFT $\notπ$ ) is investigated as a framework for the analysis of multinucleon spectra and matrix elements calculated in lattice QCD (LQCD). By combining FVEFT π with the stochastic variational method, the spectra of nuclei with atomic number A ∈ {2, 3} are matched to existing finite-volume LQCD calculations at heavier-than-physical quark masses corresponding to a pion mass m $\notπ$ = 806 MeV , thereby enabling infinite-volume binding energies to be determined using infinite-volume variational calculations. Based on the variational wave functions that are constructed in this approach, the finite-volume matrix elements of various local operators are computed in FVEFT $\notπ$ and matched to LQCD calculations of the corresponding QCD operators in the same volume, thereby determining the relevant one- and two-body effective field theory counterterms and enabling an extrapolation of the LQCD matrix elements to infinite volume. As examples, the scalar, tensor, and axial matrix elements are considered, in addition to the magnetic moments and the isovector longitudinal momentum fraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-248: Near Real-Time Analysis of Radiation Delivery and Imaging, Accuracy to Ensure Patient Safety

Purpose: To develop and optimize an effective software method for comparing planned to delivered control point machine parameters for all VARIAN TrueBeam treatments so as to permit (1) assessment of a large patient pool throughout their treatment course to quantify treatment technique specific systematic and random uncertainty of observables, (2) quantify the site specific daily imaging shifts required for target alignment, and (3) define tolerance levels for mechanical parameters and imaging parameters based on statistical analysis data gathered, and the dosimetric impact of variations. Methods: Treatment and imaging log files were directly compared to plan parameters for Eclipse and Pinnacle planned treatments via 3D, IMRT, control point, RapidArc, and electrons. Each control point from all beams/arcs (7984) for all fractions (1940) of all patients treated over six months were analyzed. At each control point gantry angle, collimator angle, couch angle, jaw positions, MLC positions, MU were compared. Additionally per-treatment isocenter shifts were calculated. Results were analyzed as a whole in treatment type subsets: IMRT, 3D, RapidArc; and in treatment site subsets: brain, chest/mediastinum, esophagus, H and N, lung, pelvis, prostate. Results: Daily imaging isocenter shifts from initial external tattoo alignment were dependent on the treatment site with < 0.5 cm translational shifts for H and N, Brain, and lung SBRT, while pelvis, esophagus shifts were ∼1 cm. Mechanical delivery parameters were within tolerance levels for all sub-beams. The largest variations were for RapidArc plans: gantry angle 0.11±0.12,collimator angle 0.00±0.00, jaw positions 0.48±0.26, MLC leaf positions 0.66±0.08, MU 0.14±0.34. Conclusion: Per-control point validation reveals deviations between planned and delivered parameters. If used in a near real-time error checking system, patient safety can be improved by equipping the treatment delivery system with additional forcing functions which by-pass human error avenues.

60 APPLIED LIFE SCIENCES↗

Measurement of neutron and gamma-ray noise in large subcritical condition for criticality safety - 14485

Various experimental methods have been proposed for subcriticality measurement and neutron noise analysis method is one of important experimental techniques for this purpose. The variance to mean value method, called Feynman-alpha method, is one of well-known noise analysis methods. In this method, variation of neutron count rate distribution from the Poisson distribution caused by fission chain reactions, which is called Y-value, is measured, however, it is difficult to measure the Y-value in large subcritical state such as nuclear fuel facility, because number of emitted neutrons by fission chain reaction is small, which causes large statistical error. We developed new experimental technique based on Feynman-alpha method combined with pulsed neutron source, called Delayed Neutron Noise Analysis (DNNA) method, to monitor the change of subcriticality. In this new method, neutron and gamma-ray counts measured only appeared in the delayed neutron region after injection of pulsed neutron are analyzed, and the prompt neutron region is completely ignored. The advantage of DNNA compared with conventional method is that spatial dependency of detector positions on measured results can be greatly decreased, which result in increase of accuracy of measured subcriticality. The validity of the DNNA method was experimentally investigated in the Kyoto University Critical Assembly (KUCA) at Kyoto University Research Reactor Institute. In the experiments, pulsed neutrons by D-T reactions are injected into the core and we used {sup 3}He detectors to measure neutron noise signals and BGO scintillation detectors to measure gamma-ray noise signals, and all data in the delayed neutron region were analyzed based on Feynman-alpha method. From the experimental results, it was found that the Y-values are clearly larger than zero in the case of existence of fuel assemblies and this method can be applied to detection of hidden special nuclear materials for example in a cargo container. (authors)

42 ENGINEERING↗

Detecting sulphate aerosol geoengineering with different methods

Sulphate aerosol injection has been widely discussed as a possible way to engineer future climate. Monitoring it would require detecting its effects amidst internal variability and in the presence of other external forcings. Here, we investigate how the use of different detection methods and filtering techniques affects the detectability of sulphate aerosol geoengineering in annual-mean global-mean near-surface air temperature. This is done by assuming a future scenario that injects 5 Tg yr -1 of sulphur dioxide into the stratosphere and cross-comparing simulations from 5 climate models. 64% of the studied comparisons would require 25 years or more for detection when no filter and the multi-variate method that has been extensively used for attributing climate change are used, while 66% of the same comparisons would require fewer than 10 years for detection using a trend-based filter. This then highlights the high sensitivity of sulphate aerosol geoengineering detectability to the choice of filter. With the same trend-based filter but a non-stationary method, 80% of the comparisons would require fewer than 10 years for detection. This does not imply sulphate aerosol geoengineering should be deployed, but suggests that both detection methods could be used for monitoring geoengineering in global, annual mean temperature should it be needed.

54 ENVIRONMENTAL SCIENCES↗

Small-Angle Neutron Scattering for Studying Lipid Bilayer Membranes

Small-angle neutron scattering (SANS) is a powerful tool for studying biological membranes and model lipid bilayer membranes. The length scales probed by SANS, being from 1 nm to over 100 nm, are well-matched to the relevant length scales of the bilayer, particularly when it is in the form of a vesicle. However, it is the ability of SANS to differentiate between isotopes of hydrogen as well as the availability of deuterium labeled lipids that truly enable SANS to reveal details of membranes that are not accessible with the use of other techniques, such as small-angle X-ray scattering. In this work, an overview of the use of SANS for studying unilamellar lipid bilayer vesicles is presented. The technique is briefly presented, and the power of selective deuteration and contrast variation methods is discussed. Approaches to modeling SANS data from unilamellar lipid bilayer vesicles are presented. Finally, recent examples are discussed. While the emphasis is on studies of unilamellar vesicles, examples of the use of SANS to study intact cells are also presented.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and Management of Interfractional Anatomic Changes for Pancreatic Cancer Radiotherapy

Purpose: To quantitatively characterize interfractional anatomic variations in pancreatic cancer radiotherapy (RT) and to study dosimetric advantages for using an online adaptive replanning scheme to account for these variations. Methods and Materials: Targets and organs at risk (OAR) were delineated by autosegmentation based on daily computed tomography (CT) images acquired using a respiration-gated in-room CT during daily image-guided RT (IGRT) for 10 pancreatic cancer patients. Various parameters, including the maximum overlap ratio (MOR) between the volumes based on planning and daily CTs for a structure, while the overlapping volumes were maximized, were used to quantify the interfractional organ deformation with the intrafractional variations largely excluded. An online adaptive RT (ART) was applied to these daily CTs. To evaluate the dosimetric benefits of ART, the dose distributions from the online ART were compared to those from the repositioning in the current standard IGRT practice. Results: The interfractional anatomic variations, particularly the organ deformation, are significant during pancreas irradiation. For the patients studied, the average MORs of all daily CTs were 80.2%, 61.7%, and 72.2% for pancreatic head, duodenum, and stomach, respectively. The online ART leads to improved dosimetric plan with better target coverage and/or OAR sparing than IGRT repositioning. For the patients studied, the mean V{sub 50.4Gy} (volume covered by 50.4 Gy) for the duodenum was reduced from 43.4% for IGRT to 15.6% for the online ART scheme. Conclusions: The online adaptive RT scheme can effectively account for the significant interfractional anatomic variations observed in pancreas irradiation. The dosimetric advantages with the online ART may enable safe dose escalation in radiation therapy for pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lattice study of quark distribution amplitudes in the pion and its excitations

Lattice QCD serves as a computational framework capable of predicting the spectrum of hadronic excitations from first principles. Our desire to describe the wealth of existing experimental data on the spectrum and to predict the outcomes of future experiments poses numerous challenges. Thus, obtaining an accurate resolution of excited states using methods of LQCD is complicated due to the faster decay of excited state correlation functions in Euclidean space in comparison with those of ground states, which we overcome through the use of anisotropic lattices with a finer temporal than spatial discretization. The aim of this project is to go beyond the spectrum to discern the structure of the states through the computation of the quark distribution amplitudes for both the ground and excited pion states on improved anisotropic lattices developed by the Hadron Spectrum Collaboration. Application of variational method allows us to extract the excited-state spectrum. When combined with undergoing parallel perturbative study of renormalization coefficients for quark bilinear operators, this work will enable us to explore the internal structure of the excited states, and to investigate the approach to a quark and gluon description of hadrons when probed at high-momentum transfers.

Mastropas, Ekaterina↗

Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy

Purpose: To quantify interfractional anatomic variations and limitations of the current practice of image-guided radiation therapy (IGRT) for prostate-bed patients and to study dosimetric benefits of an online adaptive replanning scheme that addresses the interfractional variations. Methods: Contours for the targets and organs at risk (OARs) from daily diagnostic-quality CTs acquired with in-room CT (CTVision, Siemens) were generated by populating the planning contours using an autosegmentation tool based on deformable registration (ABAS, Elekta) with manual editing for ten prostate-bed patients treated with postoperative daily CT-guided IMRT. Dice similarity coefficient (DSC) obtained by maximizing the overlap of contours for a structure between the daily and plan contours was used to quantify the organ deformation between the plan and daily CTs. Three interfractional-variation-correction schemes, the current standard practice of IGRT repositioning, a previously developed online adaptive RT (ART), and the full reoptimization, were applied to these daily CTs and a number of dose-volume quantities for the targets and organs at risk were compared for their effectiveness to account for the interfractional variations. Results: Large interfractional organ deformations in prostate-bed irradiation were seen. The mean DSCs for CTV, rectum, and bladder were 86.6 ± 5.1% (range from 61% to 97%), 77.3% ± 7.4% (range from 55% to 90%), and 75.4% ± 11.2% (range from 46% to 96%), respectively. The fractional and cumulative dose-volume quantities for CTV and PTV: V100 (volume received at least 100% prescription dose), and rectum and bladder: V{sub 45Gy} and V{sub 60Gy} (volume received at least 45 or 60 Gy), were compared for the repositioning, adaptive, reoptimization, and original plans. The fractional and cumulative dosimetric results were nearly the same. The average cumulative CTV V100 were 88.0%, 98.4%, 99.2%, and 99.3% for the IGRT, ART, reoptimization, and original plans, respectively. The corresponding rectal V{sub 45Gy} (V{sub 60Gy}) were 58.7% (27.3%), 48.1% (20.7%), 43.8% (16.1%), and 44.9% (16.8%). The results for bladder were comparable among three schemes. Paired two-tailed Wilcoxon signed-rank tests were performed and it was found that ART and reoptimization provide better target coverage and better OAR sparing, especially rectum sparing. Conclusions: The interfractional organ motions and deformations during prostate-bed irradiation are significant. The online adaptive replanning scheme is capable of effectively addressing the large organ deformation, resulting in cumulative doses equivalent to those originally planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Establishing reference ranges for circulating biomarkers of drug‐induced liver injury in healthy human volunteers 1

Aims The potential of mechanistic biomarkers to improve prediction of drug‐induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration, as well as to characterize their natural variability and impact of diurnal variation. Methods Serum samples from 227 healthy volunteers were recruited as part of a cross‐sectional study; of these, 25 subjects had weekly serial sampling over 3 weeks, while 23 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA‐122 (miR‐122), High Mobility Group Box‐1 (HMGB1), total Keratin‐18 (K18), caspase‐cleaved Keratin‐18 (ccK18), Glutamate Dehydrogenase (GLDH) and Macrophage Colony‐Stimulating Factor‐1 (CSF‐1) were assayed. Results Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models. Intra‐individual variability was found to be non‐significant, and there was no significant impact of diurnal variation. Conclusion Reference intervals for novel DILI biomarkers have been described. An upper limit of a reference range might represent the most appropriate mechanism to utilize these data. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification as required by regulatory authorities.

Jorgensen, Andrea L. [Department of Health Data Sc↗

Adaptive Replanning to Account for Lumpectomy Cavity Change in Sequential Boost After Whole-Breast Irradiation

Purpose: To evaluate the efficiency of standard image-guided radiation therapy (IGRT) to account for lumpectomy cavity (LC) variation during whole-breast irradiation (WBI) and propose an adaptive strategy to improve dosimetry if IGRT fails to address the interfraction LC variations. Methods and Materials: Daily diagnostic-quality CT data acquired during IGRT in the boost stage using an in-room CT for 19 breast cancer patients treated with sequential boost after WBI in the prone position were retrospectively analyzed. Contours of the LC, treated breast, ipsilateral lung, and heart were generated by populating contours from planning CTs to boost fraction CTs using an auto-segmentation tool with manual editing. Three plans were generated on each fraction CT: (1) a repositioning plan by applying the original boost plan with the shift determined by IGRT; (2) an adaptive plan by modifying the original plan according to a fraction CT; and (3) a reoptimization plan by a full-scale optimization. Results: Significant variations were observed in LC. The change in LC volume at the first boost fraction ranged from a 70% decrease to a 50% increase of that on the planning CT. The adaptive and reoptimization plans were comparable. Compared with the repositioning plans, the adaptive plans led to an improvement in target coverage for an increased LC case (1 of 19, 7.5% increase in planning target volume evaluation volume V{sub 95%}), and breast tissue sparing for an LC decrease larger than 35% (3 of 19, 7.5% decrease in breast evaluation volume V{sub 50%}; P=.008). Conclusion: Significant changes in LC shape and volume at the time of boost that deviate from the original plan for WBI with sequential boost can be addressed by adaptive replanning at the first boost fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Latent Twins

Over the past decade, scientific machine learning has transformed the development of mathematical and computational frameworks for analyzing, modeling, and predicting complex systems. From inverse problems to numerical partial differential equations (PDEs), dynamical systems, and model reduction, these advances have pushed the boundaries of what can be simulated. Yet they have often progressed in parallel, with representation learning and algorithmic solution methods evolving largely as separate pipelines. With Latent Twins, we propose a unifying mathematical framework that creates a hidden surrogate in latent space for the underlying equations. Whereas digital twins mirror physical systems in the digital world, Latent Twins mirror mathematical systems in a learned latent space governed by operators. Through this lens, classical modeling, inversion, model reduction, and operator approximation all emerge as special cases of a single principle. We establish the fundamental approximation properties of Latent Twins for both ordinary differential equations (ODEs) and PDEs and demonstrate the framework across three representative settings: (i) canonical ODEs, capturing diverse dynamical regimes; (ii) a PDE benchmark using the shallow-water equations, contrasting Latent Twin simulations with deep operator network and forecasts with a four-dimensional variational method baseline; and (iii) a challenging real-data geopotential reanalysis dataset, reconstructing and forecasting from sparse, noisy observations. Latent Twins provide a compact, interpretable surrogate for solution operators that evaluate across arbitrary time gaps in a single-shot, while remaining compatible with scientific pipelines such as assimilation, control, and uncertainty quantification. Looking forward, this framework offers scalable, theory-grounded surrogates that bridge data-driven representation learning and classical scientific modeling across disciplines.

Latent Twins↗

Inference offers a metric to constrain dynamical models of neutrino flavor transformation

The multimessenger astrophysics of compact objects presents a vast range of environments where neutrino flavor transformation may occur and may be important for nucleosynthesis, dynamics, and a detected neutrino signal. Development of efficient techniques for surveying flavor evolution solution spaces in these diverse environments, which augment and complement existing sophisticated computational tools, could leverage progress in this field. To this end we continue our exploration of statistical data assimilation (SDA) to identify solutions to a small-scale model of neutrino flavor transformation. SDA is a machine learning formula wherein a dynamical model is assumed to generate any measured quantities. Specifically, we use an optimization formulation of SDA wherein a cost function is extremized via the variational method. Regions of state space in which the extremization identifies the global minimum of the cost function will correspond to parameter regimes in which a model solution can exist. Our example study seeks to infer the flavor transformation histories of two monoenergetic neutrino beams coherently interacting with each other and with a matter background. We require that the solution be consistent with measured neutrino flavor fluxes at the point of detection, and with constraints placed upon the flavor content at various locations along their trajectories, such as the point of emission, and the locations of the Mikheyev-Smirnov-Wolfenstein resonances. We show how the procedure efficiently identifies solution regimes and rules out regimes where solutions are infeasible. Overall, results in this work intimate the promise of this “variational annealing” methodology to efficiently probe an array of fundamental questions that traditional numerical simulation codes render difficult to access.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-262: Variability in Texture Analysis of Gynecological Tumors in the Context of An 18F-FDG PET Adaptive Protocol

Purpose: This study examines the effect on texture analysis due to variable reconstruction of PET images in the context of an adaptive FDG PET protocol for node positive gynecologic cancer patients. By measuring variability in texture features from baseline and intra-treatment PET-CT, we can isolate unreliable texture features due to large variation. Methods: A subset of seven patients with node positive gynecological cancers visible on PET was selected for this study. Prescribed dose varied between 45–50.4Gy, with a 55–70Gy boost to the PET positive nodes. A baseline and intratreatment (between 30–36Gy) PET-CT were obtained on a Siemens Biograph mCT. Each clinical PET image set was reconstructed 6 times using a TrueX+TOF algorithm with varying iterations and Gaussian filter. Baseline and intra-treatment primary GTVs were segmented using PET Edge (MIM Software Inc., Cleveland, OH), a semi-automatic gradient-based algorithm, on the clinical PET and transferred to the other reconstructed sets. Using an in-house MATLAB program, four 3D texture matrices describing relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 textural features characterizing texture were calculated in addition to SUV histogram features. The percent variability among parameters was first calculated. Each reconstructed texture feature from baseline and intra-treatment per patient was normalized to the clinical baseline scan and compared using the Wilcoxon signed-rank test in order to isolate variations due to reconstruction parameters. Results: For the baseline scans, 13 texture features showed a mean range greater than 10%. For the intra scans, 28 texture features showed a mean range greater than 10%. Comparing baseline to intra scans, 25 texture features showed p <0.05. Conclusion: Variability due to different reconstruction parameters increased with treatment, however, the majority of texture features showed significant changes during treatment independent of reconstruction effects.

60 APPLIED LIFE SCIENCES↗

Solid-State Solvation and Enhanced Exciton Diffusion in Doped Organic Thin Films under Mechanical Pressure

Direct modification of exciton energy has been previously used to optimize the operation of organic optoelectronic devices. One demonstrated method for exciton energy modification is through the use of the solvent dielectric effects in doped molecular films. To gain a deeper appreciation of the underlying physical mechanisms, we test the solid-state solvation effect in molecular thin films under applied external pressure. We observe that external mechanical pressure increases dipole–dipole interactions, leading to shifts in the Frenkel exciton energy and enhancement of the time-resolved spectral red shift associated with the energy-transfer-mediated exciton diffusion. Measurements are performed on host:dopant molecular thin films, which show bathochromic shifts in photoluminescence (PL) under increasing pressure. This is in agreement with a simple solvation theory model of exciton energetics with a fitting parameter based on the mechanical properties of the host matrix material. We measure no significant change in exciton lifetime with increasing pressure, consistent with unchanged aggregation in molecular films under compression. However, we do observe an increase in exciton spectral thermalization rate for compressed molecular films, indicating enhanced exciton diffusion for increased dipole–dipole interactions under pressure. The results highlight the contrast between molecular energy landscapes obtained when dipole–dipole interactions are increased by the pressure technique versus the conventional dopant concentration variation methods, which can lead to extraneous effects such as aggregation at higher doping concentrations. The present work demonstrates the use of pressure-probing techniques in studying energy disorder and exciton dynamics in amorphous molecular thin films.

36 MATERIALS SCIENCE↗

Evaluation of molecular volume change of block copolymer depending on temperature: A SANS study

Amphiphilic Pluronic triblock copolymers form various self-assembled structures such as sphere, cylinder, lamellae and so on, depending on temperature, leading to the increase of hydrophobicity of block copolymers. However, the effective molecular volume change of the block copolymer has not been fully exploited yet, when temperature increases. Here in this paper, we have investigated the effective molecular volume change of the block copolymer upon heating by using the contrast variation small angle neutron scattering. The scattering length densities (SLDs) of the block copolymer were experimentally obtained from the neutron scattering contrast variation method between the solvent and the block copolymer at varying temperature. Even though the SLD, which is the intrinsic property of the material, should not be changed by temperature elevation, it was dependent on temperature, indicating that the molecular volume is changed. Therefore, we obtained the increase rate of the molecular volume change of the block copolymer (the effective molecular volume change) from the comparison of the calculated SLD and the standard SLD, which is evaluated by plotting the SANS intensity at the first order Bragg peak as the function of temperature at each volume fraction of D 2 O and H 2 O that is about 25.5%–51.3% depending on temperature.

36 MATERIALS SCIENCE↗

MO-FG-202-01: A Fast Yet Sensitive EPID-Based Real-Time Treatment Verification System

Purpose: To create a real-time EPID-based treatment verification system which robustly detects treatment delivery and patient attenuation variations. Methods: Treatment plan DICOM files sent to the record-and-verify system are captured and utilized to predict EPID images for each planned control point using a modified GPU-based digitally reconstructed radiograph algorithm which accounts for the patient attenuation, source energy fluence, source size effects, and MLC attenuation. The DICOM and predicted images are utilized by our C++ treatment verification software which compares EPID acquired 1024×768 resolution frames acquired at ∼8.5hz from Varian Truebeam™ system. To maximize detection sensitivity, image comparisons determine (1) if radiation exists outside of the desired treatment field; (2) if radiation is lacking inside the treatment field; (3) if translations, rotations, and magnifications of the image are within tolerance. Acquisition was tested with known test fields and prior patient fields. Error detection was tested in real-time and utilizing images acquired during treatment with another system. Results: The computational time of the prediction algorithms, for a patient plan with 350 control points and 60×60×42cm^3 CT volume, is 2–3minutes on CPU and <27 seconds on GPU for 1024×768 images. The verification software requires a maximum of ∼9ms and ∼19ms for 512×384 and 1024×768 resolution images, respectively, to perform image analysis and dosimetric validations. Typical variations in geometric parameters between reference and the measured images are 0.32°for gantry rotation, 1.006 for scaling factor, and 0.67mm for translation. For excess out-of-field/missing in-field fluence, with masks extending 1mm (at isocenter) from the detected aperture edge, the average total in-field area missing EPID fluence was 1.5mm2 the out-of-field excess EPID fluence was 8mm^2, both below error tolerances. Conclusion: A real-time verification software, with EPID images prediction algorithm, was developed. The system is capable of performing verifications between frames acquisitions and identifying source(s) of any out-of-tolerance variations. This work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Probing Actinide Electronic Structure through Pu Cluster Calculations

The calculations for the electronic structure of clusters of plutonium have been performed, within the framework of the relativistic discrete-variational method. Moreover, these theoretical results and those calculated earlier for related systems have been compared to spectroscopic data produced in the experimental investigations of bulk systems, including photoelectron spectroscopy. Observation of the changes in the Pu electronic structure as a function of size provides powerful insight for aspects of bulk Pu electronic structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗