Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

TH-A-BRF-05: MRI of Individual Lymph Nodes to Guide Regional Breast Radiotherapy

Purpose: In regional radiotherapy (RT) for breast-cancer patients, direct visualization of individual lymph nodes (LNs) may reduce target volumes and Result in lower toxicity (i.e. reduced radiation pneumonitis, arm edema, arm morbidity), relative to standard CT-based delineations. To this end, newly designed magnetic resonance imaging (MRI) sequences were optimized and assessed qualitatively and quantitatively. Methods: In ten healthy female volunteers, a scanning protocol was developed and optimized. Coronal images were acquired in supine RT position positioned on a wedge board on a 1.5 T Ingenia (Philips) wide-bore MRI. In four volunteers the optimized MRI protocol was applied, including a 3-dimensional (3D) T1-weighted (T1w) fast-field-echo (FFE). T2w sequences, including 3D FFE, 3D and 2D fast spin echo (FSE), and diffusion-weighted single-shot echo-planar imaging (DWI) were also performed. Several fatsuppression techniques were used. Qualitative evaluation parameters included LN contrast, motion susceptibility, visibility of anatomical structures, and fat suppression. The number of visible axillary and supraclavicular LNs was also determined. Results: T1 FFE, insensitive to motion, lacked contrast of LNs, which often blended in with soft tissue and blood. T2 FFE showed high contrast, but some LNs were obscured due to motion. Both 2D and 3D FSE were motion-insensitive having high contrast, although some blood remained visible. 2D FSE showed more anatomical details, while in 3D FSE, some blurring occurred. DWI showed high LN contrast, but suffered from geometric distortions and low resolution. Fat suppression by mDixon was the most reliable in regions with magnetic-field inhomogeneities. The FSE sequences showed the highest sensitivity for LN detection. Conclusion: MRI of regional LNs was achieved in volunteers. The FSE techniques were robust and the most sensitive. Our optimized MRI sequences can facilitate direct delineation of individual LNs. This can Result in smaller target volumes and reduced toxicity in regional RT compared to standard CT planning.

60 APPLIED LIFE SCIENCES↗

TU-D-202-03: Gating Is the Best ITV Killer

Respiratory motion has long been recognized as an important factor affecting the precision of radiotherapy. After the introduction of the 4D CT to visualize the respiratory motion in 3D, the internal target volume (ITV) has been widely adopted as simple method to take the motion into account in treatment planning and delivery. The ITV is generated as the union of the CTVs as the patient goes through the respiratory cycle. Many issues have been identified with the ITV. In this session three alternatives for the ITV will be discussed: 1) An alternative motion-inclusive approach with better imaging and smaller margins, called mid-position CT. 2) The tracking approach and 3) The gating approach. The following topics will be addressed by Marcel van Herk (“Is ITV the correct motion encompassing strategy”): Magnitude of respiratory motion, effect of motion on radiotherapy, motion encompassing strategies, and software solutions to assist in motion encompassing strategies. Then Paul Keall (“Make margins simple: Use real-time target tracking”) will discuss tracking with: clinical drivers for tracking, current clinical status of tumor tracking, future tumor tracking technology, and margin margin challenges with and without tracking. Finally Daniel Low will discuss gating (“Gating is the best ITV killer”): why ITV in the first place, requirements for planning, requirements at the machine, benefits and costs. The session will end with a discussion and live demo of motion simulation software to illustrate the issues and explain the relative benefit and appropriate uses for the three methods. Learning Objectives: Explain the 4D imaging and treatment planning process. Summarize the various approaches to deal with respiratory motion during radiotherapy Discuss the tradeoffs involved when choosing one of the three discussed approaches. Explain in which situation each method is the best choice Research is partly funded by Elekta Oncology Systems and the Dutch Cancer Foundation; M. van Herk, Part of the research was funded by Elekta Oncology Systems and the Dutch Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Scientific Data Management Center for Enabling Technologies

Managing scientific data has been identified by the scientific community as one of the most important emerging needs because of the sheer volume and increasing complexity of data being collected. Effectively generating, managing, and analyzing this information requires a comprehensive, end-to-end approach to data management that encompasses all of the stages from the initial data acquisition to the final analysis of the data. Fortunately, the data management problems encountered by most scientific domains are common enough to be addressed through shared technology solutions. Based on community input, we have identified three significant requirements. First, more efficient access to storage systems is needed. In particular, parallel file system and I/O system improvements are needed to write and read large volumes of data without slowing a simulation, analysis, or visualization engine.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Testing of a 3-D Sonar for Future Deployment to Image Solids on the Floor of Hanford, HLW Conditioning Tanks - 15646

Florida International University (FIU) has tested the capability of 2-D and 3-D sonar systems to image solids settled on the floor of tanks, on the bottom of streams and small rivers, and in 55 gallon drums. FIU developed and successfully tested the Solid-Liquid Interface Monitor (SLIM) for mapping the interface between supernatant and settled solids in several test tanks. SLIM is comprised of: a sonar, a mechanical system for deploying the system into large high-level radioactive waste (HLW) tanks, and imaging programs and algorithms developed at and by FIU faculty and staff. Early testing had the objective to demonstrate the ability of SLIM to image and quantify the height and volume of settled solids on the floor of 1-million-gallon, HLW tanks at Hanford. Testing showed that SLIM: (1) functions accurately in liquid radioactive HLW tank conditions [i.e., caustic (pH>14), warm (up to 45 degrees Centigrade), and highly radioactive]; (2) provides accurate imaging of solids surfaces (1-2% relative error in the height of interfaces); and (3) provides an excellent volume estimation of the solids, thereby allowing engineers to fill tanks closer to the maximum allowed level and optimize solids retrieval; and (4) enables better placement of pumps inside tanks during retrieval to minimize the potential for plugging. The New Hanford technology need is for rapid imaging (even during vigorous mixing) of solids on the floor of conditioning (mixing) tanks. Results of recent successful testing show imaging times under 1 minute, solids volume estimates with <5% error and effective filtering and visualization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers

Purpose: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). Methods and Materials: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed. Results: The mean seroma volume was 36.9 cm{sup 3} and 34.2 cm{sup 3} for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 {+-} 1.0 from 2.5 {+-} 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001). Conclusions: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Validating the RTOG-Endorsed Brachial Plexus Contouring Atlas: An Evaluation of Reproducibility Among Patients Treated by Intensity-Modulated Radiotherapy for Head-and-Neck Cancer

Purpose: To evaluate interobserver variability for contouring the brachial plexus as an organ-at-risk (OAR) and to analyze its potential dosimetric consequences in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: Using the Radiation Therapy Oncology Group (RTOG)-endorsed brachial plexus contouring atlas, three radiation oncologists independently delineated the OAR on treatment planning computed-tomography (CT) axial scans from 5 representative patients undergoing IMRT to a prescribed dose of 70 Gy for head-and-neck cancer. Dose-volume histograms for the brachial plexus were calculated, and interobserver differences were quantified by comparing various dosimetric statistics. Qualitative analysis was performed by visually assessing the overlapping contours on a single beam's eye view. Results: Brachial plexus volumes for the 5 patients across observers were 26 cc (18-35 cc), 25 cc (21-30 cc), 29 cc (28-32 cc), 29 cc (23-38 cc), and 29 cc (23-34 cc). On qualitative analysis, minimal variability existed except at the inferolateral portion of the OAR, where slight discrepancies were noted among the physicians. Maximum doses to the brachial plexus ranged from 71.6 to 72.6 Gy, 75.2 to 75.8 Gy, 69.1 to 71.0 Gy, 76.4 to 76.9 Gy, and 70.6 to 71.4 Gy. Respective volumes receiving doses greater than 60 Gy (V60) were 8.6 to 10.9 cc, 6.2 to 8.1 cc, 8.2 to 11.6 cc, 8.3 to 10.5 cc, and 5.6 to 9.8 cc. Conclusion: The RTOG-endorsed brachial plexus atlas provides a consistent set of guidelines for contouring this OAR with essentially no learning curve. Adoption of these contouring guidelines in the clinical setting is encouraged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualizing metagenomic and metatranscriptomic data: A comprehensive review

The fields of Metagenomics and Metatranscriptomics involve the examination of complete nucleotide sequences, gene identification, and analysis of potential biological functions within diverse organisms or environmental samples. Despite the vast opportunities for discovery in metagenomics, the sheer volume and complexity of sequence data often present challenges in processing analysis and visualization. This article highlights the critical role of advanced visualization tools in enabling effective exploration, querying, and analysis of these complex datasets. Emphasizing the importance of accessibility, the article categorizes various visualizers based on their intended applications and highlights their utility in empowering bioinformaticians and non-bioinformaticians to interpret and derive insights from meta-omics data effectively.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-R-25: Automatic Identification of Suspicious Recurrent/residual Disease Regions After Prostatectomy

Purpose: To automatically identify and outline suspicious regions of recurrent or residual disease in the prostate bed using Dynamic Contrast Enhanced-MRI (DCE-MRI) in patients after prostatectomy. Methods: Twenty-two patients presenting for salvage radiotherapy and with identified Gross Tumor Volume (GTV) in the prostate bed were retrospectively analyzed. The MRI data consisted of Axial T2weighted-MRI (T2w) of the pelvis: resolution 1.25×1.25×2.5 mm; Field of View (FOV): 320×320 mm; slice thickness=2.5mm; 72 slices; and Dynamic Contrast Enhanced MRI (DCE-MRI)–12 series of T1w with identical spatial resolution to T2w and at 30–34s temporal resolution. Unsupervised pattern recognition was used to decompose the 4D DCE data as the product W.H of weights W of k patterns H. A well-perfused pattern Hwp was identified and the weight map Wwp associated to Hwp was used to delineate suspicious volumes. Threshold of Wwp set at mean(Wwp)+S*std(Wwp), S=1,1.5,2 and 2.5 defined four volumes labeled as DCE1.0 to DCE2.5. These volumes were displayed on T2w and, along with GTV, were correlated with the highest pre-treatment PSA values, and with pharmacokinetic analysis constants. Results: GTV was significantly correlated with DCE2.0(ρ= 0.60, p<0.003), and DCE 2.5 (ρ=0.58, p=0.004)). Significant correlation was found between highest pre-treatment PSA and GTV(ρ=0.42, p<0.049), DCE2.0(ρ= 0.52, p<0.012), and DCE 2.5 (ρ=0.67, p<<0.01)). Kruskal-Wallis analysis showed that Ktrans median value was statistically different between non-specific prostate bed tissue NSPBT and both GTV (p<<0.001) and DCE2.5 (p<<0.001), but while median Ve was statistically different between DCE2.5 and NSPBT (p=0.002), it was not statistically different between GTV and NSPBT (p=0.054), suggesting that automatic volumes capture more accurately the area of malignancy. Conclusion: Software developed for identification and visualization of suspicions regions in DCE-MRI from post-prostatectomy patients has been validated by PSA and pharmacokinetic constants analysis showing that it generates clinically relevant volumes.

60 APPLIED LIFE SCIENCES↗

Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm{sup 3}. Organs with volumes <3 cm{sup 3} and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm{sup 3}), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of contours.” Conclusions: Use of DIR-based contour propagation in the routine clinical setting is expected to increase the efficiency of H and N replanning, reducing the amount of time needed for manual target and organ delineations.

60 APPLIED LIFE SCIENCES↗

From Voxels to Knowledge: A Practical Guide to the Segmentation of Complex Electron Microscopy 3D-Data

Modern 3D electron microscopy approaches have recently allowed unprecedented insight into the 3D ultrastructural organization of cells and tissues, enabling the visualization of large macromolecular machines, such as adhesion complexes, as well as higher-order structures, such as the cytoskeleton and cellular organelles in their respective cell and tissue context. Given the inherent complexity of cellular volumes, it is essential to first extract the features of interest in order to allow visualization, quantification, and therefore comprehension of their 3D organization. Each data set is defined by distinct characteristics, e.g., signal-to-noise ratio, crispness (sharpness) of the data, heterogeneity of its features, crowdedness of features, presence or absence of characteristic shapes that allow for easy identification, and the percentage of the entire volume that a specific region of interest occupies. All these characteristics need to be considered when deciding on which approach to take for segmentation. The six different 3D ultrastructural data sets presented were obtained by three different imaging approaches: resin embedded stained electron tomography, focused ion beam- and serial block face- scanning electron microscopy (FIB-SEM, SBF-SEM) of mildly stained and heavily stained samples, respectively. For these data sets, four different segmentation approaches have been applied: (1) fully manual model building followed solely by visualization of the model, (2) manual tracing segmentation of the data followed by surface rendering, (3) semi-automated approaches followed by surface rendering, or (4) automated custom-designed segmentation algorithms followed by surface rendering and quantitative analysis. Depending on the combination of data set characteristics, it was found that typically one of these four categorical approaches outperforms the others, but depending on the exact sequence of criteria, more than one approach may be successful. Based on these data, we propose a triage scheme that categorizes both objective data set characteristics and subjective personal criteria for the analysis of the different data sets.

3D electron microscopy↗

Planning the Breast Boost: Comparison of Three Techniques and Evolution of Tumor Bed During Treatment

Purpose: To evaluate the accuracy of two clinical techniques for electron boost planning compared with computed tomography (CT)-based planning. Additionally, we evaluated the tumor bed characteristics at whole breast planning and boost planning. Methods and Materials: A total of 30 women underwent tumor bed boost planning within 2 weeks of completing whole breast radiotherapy using three planning techniques: scar-based planning, palpation/clinical-based planning, and CT-based planning. The plans were analyzed for dosimetric coverage of the CT-delineated tumor bed. The cavity visualization score was used to define the CT-delineated tumor bed as well or poorly defined. Results: Scar-based planning resulted in inferior tumor bed coverage compared with CT-based planning, with the minimal dose received by 90% of the target volume >90% in 53% and a geographic miss in 53%. The results of palpation/clinical-based planning were significantly better: 87% and 10% for the minimal dose received by 90% of the target volume >90% and geographic miss, respectively. Of the 30 tumor beds, 16 were poorly defined by the cavity visualization score. Of these 16, 8 were well demarcated by the surgical clips. The evaluation of the 22 well-defined tumor beds revealed similar results. A comparison of the tumor bed volume from the initial planning CT scan to the boost planning CT scan revealed a decrease in size in 77% of cases. The mean decrease in volume was 52%. Conclusion: The results of our study have shown that CT-based planning allows for optimal tumor bed coverage compared with clinical and scar-based approaches. However, in the setting of a poorly visualized cavity on CT without surgical clips, palpation/clinical-based planning can help delineate the appropriate target volumes and is superior to scar-based planning. CT simulation at boost planning could allow for a reduction in the boost volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Immersive Visual Analytics for Transformative Neutron Scattering Science

The ORNL Spallation Neutron Source (SNS) provides the most intense pulsed neutron beams in the world for scientific research and development across a broad range of disciplines. SNS experiments produce large volumes of complex data that are analyzed by scientists with varying degrees of experience using 3D visualization and analysis systems. However, it is notoriously difficult to achieve proficiency with 3D visualizations. Because 3D representations are key to understanding the neutron scattering data, scientists are unable to analyze their data in a timely fashion resulting in inefficient use of the limited and expensive SNS beam time. We believe a more intuitive interface for exploring neutron scattering data can be created by combining immersive virtual reality technology with high performance data analytics and human interaction. In this paper, we present our initial investigations of immersive visualization concepts as well as our vision for an immersive visual analytics framework that could lower the barriers to 3D exploratory data analysis of neutron scattering data at the SNS.

data visualization↗

SU-E-J-264: Comparison of Two Commercially Available Software Platforms for Deformable Image Registration

Purpose: To evaluate and compare the deformable image registration algorithms available in the Velocity (Velocity Medical Solutions, Atlanta, GA) and RayStation (RaySearch Americas, Inc., Garden city NY). Methods: Ten consecutive patient cone beam CTs (CBCT) for each fraction were collected. The CBCTs along with the simulation CT were exported to the Velocity and the RayStation software. Each CBCT was registered using deformable image registration to the simulation CT and the resulting deformable vector matrix was generated. Each registration was visually inspected by a physicist and the prescribing physician. The volumes of the critical organs were calculated for each deformable CT and used for comparison. Results: The resulting deformable registrations revealed differences between the two algorithms. These differences were realized when the organs at risk were contoured on each deformed CBCT. Differences in the order of 10% ±30% in volume were observed for bladder, 17 ±21% for rectum and 16±10% for sigmoid. The prostate and PTV volume differences were in the order of 3±5%. The volumetric differences observed had a respective impact on the DVHs of all organs at risk. Differences of 8–10% in the mean dose were observed for all organs above. Conclusion: Deformable registration is a powerful tool that aids in the definition of critical structures and is often used for the evaluation of daily dose delivered to the patient. It should be noted that extended QA should be performed before clinical implementation of the software and the users should be aware of advantages and limitations of the methods.

60 APPLIED LIFE SCIENCES↗

SU-E-T-13: A Feasibility Study of the Use of Hybrid Computational Phantoms for Improved Historical Dose Reconstruction in the Study of Late Radiation Effects for Hodgkin's Lymphoma

Purpose: Radiation-induced cancer effects are well-documented following radiotherapy. Further investigation is needed to more accurately determine a dose-response relationship for late radiation effects. Recent dosimetry studies tend to use representative patients (Taylor 2009) or anthropomorphic phantoms (Wirth 2008) for estimating organ mean doses. In this study, we compare hybrid computational phantoms to patient-specific voxel phantoms to test the accuracy of University of Florida Hybrid Phantom Library (UFHP Library) for historical dose reconstructions. Methods: A cohort of 10 patients with CT images was used to reproduce the data that was collected historically for Hodgkin's lymphoma patients (i.e. caliper measurements and photographs). Four types of phantoms were generated to show a range of refinement from reference hybrid-computational phantom to patient-specific phantoms. Each patient is matched to a reference phantom from the UFHP Library based on height and weight. The reference phantom is refined in the anterior/posterior direction to create a ‘caliper-scaled phantom’. A photograph is simulated using a surface rendering from segmented CT images. Further refinement in the lateral direction is performed using ratios from a simulated-photograph to create a ‘photograph and caliper-scaled phantom’; breast size and position is visually adjusted. Patient-specific hybrid phantoms, with matched organ volumes, are generated and show the capabilities of the UF Hybrid Phantom Library. Reference, caliper-scaled, photograph and caliper-scaled, and patient-specific hybrid phantoms are compared with patient-specific voxel phantoms to determine the accuracy of the study. Results: Progression from reference phantom to patient specific hybrid shows good agreement with the patient specific voxel phantoms. Each stage of refinement shows an overall trend of improvement in dose accuracy within the study, which suggests that computational phantoms can show improved accuracy in historical dose estimates. Conclusion: Computational hybrid phantoms show promise for improved accuracy within retrospective studies when CTs and other x-ray images are not available.

60 APPLIED LIFE SCIENCES↗

SU-E-T-255: Optimized Supine Craniospinal Irradiation with Image-Guided and Field Matched Beams

Purpose: Conventional craniospinal irradiation (CSI) challenges include dose inhomogeneity at field junctions and position uncertainty due to the field divergence, particular for the two spinal fields. Here we outline a new supine CSI technique to address these difficulties. Methods: Patient was simulated in supine position. The cranial fields had isocenter at C2/C3 vertebral and were matched with 1st spinal field. Their inferior border was chosen to avoid the shoulder, as well as chin from the 1st spine field. Their collimator angles were dependent on asymmetry jaw setting of the 1st spinal field. With couch rotation, the spinal field gantry angles were adjusted to ensure, the inferior border of 1st and superior border of 2nd spinal fields were perpendicular to the table top. The radio-opaque wire position for the spinal junction was located initially by the light field from an anterior setup beam, and was finalized by the portal imaging of the 1st spinal field. With reference to the spinal junction wire, the fields were matched by positioning the isocenter of the 2nd spinal field. A formula was derived to optimize supine CSI treatment planning, by utilizing the relationship among the Yjaw setting, the spinal field gantry angles, cranial field collimator angles, and the spinal field isocenters location. The plan was delivered with portal imaging alignment for the both cranial and spinal junctions. Results: Utilizing this technique with matching beams, and conventional technique such as feathering and forwarding planning, a homogenous dose distribution was achieved throughout the entire CSI treatment volume including the spinal junction. Placing the spinal junction wire visualized in both spinal portals, allows for precise determination and verification of the appropriate match line of the spine fields. Conclusion: This technique of optimization supine CSI achieved a homogenous dose distributions and patient localization accuracy with image-guided and matched beams.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Software upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.

60 APPLIED LIFE SCIENCES↗

minilosurface

The miniIsosurface package provides a collection of reference implementations for finding a representation for a contour of a scalar field in a volume. Contouring is a well-studied algorithm in scientific visualization and there are many algorithm variations to solve it. The miniIsosurface package provides a convenient collection of the most popular variations of the contour algorithm and some variations to run in different parallel environments.

Borgeois, Daniel↗