Alternate-Fueled Combustor-Sector Performance

In order to realize alternative fueling for military and commercial use, the industry has set forth guidelines that must be met by each fuel. These aviation fueling requirements are outlined in MILDTL- 83133F(2008) or ASTM D 7566 Annex (2011) standards, and are classified as drop-in fuel replacements. This paper provides combustor performance data for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100, relative to JP-8+100 as baseline fueling. Data were taken at various nominal inlet conditions: 75 psia (0.52 MPa) at 500 F (533 K), 125 psia (0.86 MPa) at 625 F (603 K), 175 psia (1.21 MPa) at 725 F (658 K), and 225 psia (1.55 MPa) at 790 F (694 K). Combustor performance analysis assessments were made for the change in flame temperatures, combustor efficiency, wall temperatures, and exhaust plane temperatures at 3%, 4%, and 5% combustor pressure drop (% delta P) for fuel: air ratios (F/A) ranging from 0.010 to 0.025. Significant general trends show lower liner temperatures and higher flame and combustor outlet temperatures with increases in FT fueling relative to JP-8+100 fueling. The latter affects both turbine efficiency and blade/vane life.

Thomas, Anna E.↗

Heating and Efficiency Comparison of a Fischer-Tropsch (FT) Fuel, JP-8+100, and Blends in a Three-Cup Combustor Sector

In order to realize alternative fueling for military and commercial use, the industry has set forth guidelines that must be met by each fuel. These aviation fueling requirements are outlined in MIL-DTL-83133F(2008) or ASTM D 7566-Annex standards and are classified as drop-in fuel replacements. This paper provides combustor performance data for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100, relative to JP-8+100 as baseline fueling. Data were taken at various nominal inlet conditions: 75 psia (0.52 MPa) at 500 aF (533 K), 125 psia (0.86 MPa) at 625 aF (603 K), 175 psia (1.21 MPa) at 725 aF (658 K), and 225 psia (1.55 MPa) at 790 aF (694 K). Combustor performance analysis assessments were made for the change in flame temperatures, combustor efficiency, wall temperatures, and exhaust plane temperatures at 3%, 4%, and 5% combustor pressure drop (% P) for fuel:air ratios (F/A) ranging from 0.010 to 0.025. Significant general trends show lower liner temperatures and higher flame and combustor outlet temperatures with increases in FT fueling relative to JP-8+100 fueling. The latter affects both turbine efficiency and blade/vane life. In general, 100% SPK-FT fuel and blends with JP-8+100 produce less particulates and less smoke and have lower thermal impact on combustor hardware.

Thomas, Anna E.↗

Alternate-Fueled Combustor-Sector Performance

In order to realize alternative fueling for military and commercial use, the industry has set forth guidelines that must be met by each fuel. These aviation fueling requirements are outlined in MIL-DTL-83133F(2008) or ASTM D 7566 Annex (2011) standards, and are classified as "drop-in" fuel replacements. This report provides combustor performance data for synthetic-paraffinic-kerosene- (SPK-) type (Fischer-Tropsch (FT)) fuel and blends with JP-8+100, relative to JP-8+100 as baseline fueling. Data were taken at various nominal inlet conditions: 75 psia (0.52 MPa) at 500 degF (533 K), 125 psia (0.86 MPa) at 625 degF (603 K), 175 psia (1.21 MPa) at 725 degF (658 K), and 225 psia (1.55 MPa) at 790 degF (694 K). Combustor performance analysis assessments were made for the change in flame temperatures, combustor efficiency, wall temperatures, and exhaust plane temperatures at 3, 4, and 5 percent combustor pressure drop (DP) for fuel:air ratios (F/A) ranging from 0.010 to 0.025. Significant general trends show lower liner temperatures and higher flame and combustor outlet temperatures with increases in FT fueling relative to JP-8+100 fueling. The latter affects both turbine efficiency and blade and vane lives.

Thomas, Anna E.↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 – 15.8 × 10 6 m −1 . Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10×10 6 m −1 in quiet flow, while transition was already observed on the shoulders below 5×10 6 m −1 in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 × 10 6 m −1 quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 -- 15.8 x 10^6 m^{-1}. Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10 x 10^6 m^{-1} in quiet flow, while transition was already observed on the shoulders below 5 x 10^6 m^{-1} in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 x 10^6 m^{-1} quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

CFD Predictions of Boiling Regime Transitions during Line Chilldown validated against a 1G LN2 Experiment

Introduction Before filling a propellant tank on the ground or in Space, the transfer line between the donor and receiver tanks must be cooled down preferably by sacrificing a minimum amount of the cryogenic fluid. The cryogenic line chill-down process involves a transition between different flow boiling regimes, namely, film boiling, transition film boiling, and nucleate boiling which are complex and may be quite gravity-dependent. Capturing these boiling phenomena and predicting the transition between them in a CFD framework is new and challenging both for 1g and microgravity applications. Materials & Methods The present work addresses this challenge by employing a two-phase Eulerian approach in the context of a homogeneous fluid mixture together with the Lee phase change model to capture the film boiling regime of the chill-down process using ANSYS Fluent®. The nucleate boiling regime is predicted by incorporating an in-house developed sub-grid model that accounts for bubble nucleation, bubble growth, bubble departure diameter, and their shedding frequency. The sub-grid model is encoded and implemented into Fluent via a user-defined function for the wall-fluid heat flux calculations. The mathematical formulation and numerical implementation of the CFD model are described in detail. The coupled CFD-Subgrid model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Results Numerical simulation results show good agreements between the CFD predictions of the wall temperature evolution, rewetting temperature, and transition between film and nucleate boiling, with the experimental measurements published by Darr et al [2] for several different LN2 flowrates in the vertical pipe orientation. The CFD predictions for the wall temperature distribution indicate a rapid quenching of the wall at two upstream and downstream temperature sensing locations as compared to the experimental measurement. The only tuning parameter in the CFD model is the Lee mass transfer coefficient. The CFD Model predicts the Liedenfrost rewetting temperature in close agreement with the experiment. This marks a transition between stable and transitionary flow boiling regimes. The CFD-predicted boiling curve for the downstream sensor location is also compared against its experimental counterpart and indicates that the model is able to predict all the key temperature and heat flux parameters during the transitions from stable to transitionary film boiling to nucleate boiling in close agreement with the experiment. A sequence of predicted volume fraction, and temperature contours depicting these transitions will be presented.

Evaporation Condensation↗

Calculated heating on the afterbody nozzle of a hypersonic aircraft concept

The present analysis was carried out to estimate the heating levels of the external nozzle of a scramjet/airframe-integrated research aircraft. A parametric examination of the effects of Mach number, reference length, and wall temperature showed that the heating rate distributions are independent of reference length and wall temperature. The initial heating rates obtained for a Mach 6 flight are in the (3 to 8) x 10 to the 5th power W/sq m range. Underlying the entire study is the question of nozzle boundary layer formation and growth, as well as the question of the reference length value that should be used in the computations. It is shown that the reference length is not the dominant factor setting the heating levels; an attempt to bound the actual length was made. A more detailed calculation of the rates requires further work to gain a better understanding of the combustor exit boundary layer.

Talcott, N. A., Jr.↗

Cryogenic wind tunnels: Problems of continuous operation at low temperatures

The design of a cryogenic wind tunnel which operates continuously, and is capable of attaining transonic speeds at generating pressures of about 3 bars is described. Its stainless steel construction with inside insulation allows for very rapid temperature variations promoted by rapid changes in the liquid nitrogen flow. A comparative study of temperature measuring probes shows a good reliability of thin sheet thermocouples. To measure fluctuations, only a cold wire makes it possible to record frequencies of about 300 Hz. The use of an integral computer method makes it possible to determine the impact of the wall temperature ratio to the adiabatic wall temperature for the various parameters characterizing the boundary layer. These cases are processed with positive and negative pressure gradients.

Faulmann, D.↗

A compressible boundary layer algorithm for use with SINDA '85

It is useful to interface a high-speed-flow solution and SINDA to analyze the thermal behavior of systems that include both conduction and high speed flows. When interfacing a high-speed-flow solution to SINDA, it may be necessary to include the viscous effects in the energy equations. Boundary layer effects of interest include heat transfer coefficients (including convection and viscous dissipation) and friction coefficients. To meet this need, a fast, uncoupled, compressible, two-dimensional, boundary layer algorithm was developed that can model flows with and without separation. This algorithm was used as a subroutine with SINDA. Given the core flow properties and the wall heat flux from SINDA, the boundary layer algorithm returns a wall temperature to SINDA and boundary layer algorithm are iterated until they predict the same wall temperature.

Sakowski, Barbara↗

Numerical Modeling of Conjugate Heat Transfer in Fluid Network

Fluid network modeling with conjugate heat transfer has many applications in Aerospace engineering. In modeling unsteady flow with heat transfer, it is important to know the variation of wall temperature in time and space to calculate heat transfer between solid to fluid. Since wall temperature is a function of flow, a coupled analysis of temperature of solid and fluid is necessary. In cryogenic applications, modeling of conjugate heat transfer is of great importance to correctly predict boil-off rate in propellant tanks and chill down of transfer lines. In TFAWS 2003, the present author delivered a paper to describe a general-purpose computer program, GFSSP (Generalized Fluid System Simulation Program). GFSSP calculates flow distribution in complex flow circuit for compressible/incompressible, with or without heat transfer or phase change in all real fluids or mixtures. The flow circuit constitutes of fluid nodes and branches. The mass, energy and specie conservation equations are solved at the nodes where as momentum conservation equations are solved at the branches. The proposed paper describes the extension of GFSSP to model conjugate heat transfer. The network also includes solid nodes and conductors in addition to fluid nodes and branches. The energy conservation equations for solid nodes solves to determine the temperatures of the solid nodes simultaneously with all conservation equations governing fluid flow. The numerical scheme accounts for conduction, convection and radiation heat transfer. The paper will also describe the applications of the code to predict chill down of cryogenic transfer line and boil-off rate of cryogenic propellant storage tank.

Majumdar, Alok↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of recovery temperature on an airfoil in the Langley 0.3-m transonic cryogenic tunnel

Experimental measurements of recovery temperature were made on an airfoil in the Langley 0.3-m Transonic Cryogenic Tunnel at Mach numbers of 0.60 and 0.84 over a Reynolds number per meter range from about 15,000,000 to about 335,000,000. The measured recovery temperatures were considerably below those associated with ideal-gas ambient temperature wind tunnels. This difference was accentuated as the stagnation pressure increased and the total temperature decreased. A boundary-layer code modified for use with cryogenic nitrogen adequately predicted the measured adiabatic wall temperature at all conditions. A quantitative, on-line assessment of the nonadiabatic condition of a model can be made during the operation of a cryogenic wind tunnel by using a correlation for the adiabatic wall temperature which is only a function of total temperature, total pressure, and local Mach number on the model.

Johnson, C. B.↗

In-flight transition measurement on a 10 deg cone at Mach numbers from 0.5 to 2.0

Boundary layer transition measurements were made in flight on a 10 deg transition cone tested previously in 23 wind tunnels. The cone was mounted on the nose of an F-15 aircraft and flown at Mach numbers room 0.5 to 2.0 and altitudes from 1500 meters (5000 feet) to 15,000 meters (50,000 feet), overlapping the Mach number/Reynolds number envelope of the wind tunnel tests. Transition was detected using a traversing pitot probe in contact with the surface. Data were obtained near zero cone incidence and adiabatic wall temperature. Transition Reynolds number was found to be a function of Mach number and of the ratio of wall temperature to adiabatic all temperature. Microphones mounted flush with the cone surface measured free-stream disturbances imposed on the laminar boundary layer and identified Tollmien-Schlichting waves as the probable cause of transition. Transition Reynolds number also correlated with the disturbance levels as measured by the cone surface microphones under a laminar boundary layer as well as the free-stream impact.

Fisher, D. F.↗

Preliminary Drag and Heat-transfer Data Obtained from Air-launched Cone-cylinder Test Vehicle over Mach Number Range from 1.5 to 5.18

An air-launched cone-cylinder test vehicle designed to obtain data at Mach numbers above 4.0 was rocket boosted from a release Mach number of 5.18. The vehicle was launched at an altitude of 35,000 feet and reached peak velocity of 5150 feet per second at 28,500 feet. The total-drag coefficient (based on maximum cross-sectional area) decreased gradually from 0.31 at a Mach number of 1.75 to 0.145 at a Mach number of 5.18, while the Reynold's number (based on body length) increased from 31 x 10 to the 6th power to 107 x 10 to the 6th power. The skin friction coefficients, in general, were slightly lower than Van Driest's theoretical values for similar wall-temperature conditions. Convective heat-transfer coefficients were obtained from a single skin-thermocouple measurement. The maximum wall temperature recorded was 1240 degrees r.

Messing, Wesley E↗

Experimental Studies of the Heat Transfer to RBCC Rocket Nozzles for CFD Application to Design Methodologies

Rocket thrusters for Rocket Based Combined Cycle (RBCC) engines typically operate with hydrogen/oxygen propellants in a very compact space. Packaging considerations lead to designs with either axisymmetric or two-dimensional throat sections. Nozzles tend to be either two- or three-dimensional. Heat transfer characteristics, particularly in the throat, where the peak heat flux occurs, are not well understood. Heat transfer predictions for these small thrusters have been made with one-dimensional analysis such as the Bartz equation or scaling of test data from much larger thrusters. The current work addresses this issue with an experimental program that examines the heat transfer characteristics of a gaseous oxygen (GO2)/gaseous hydrogen (GH2) two-dimensional compact rocket thruster. The experiments involved measuring the axial wall temperature profile in the nozzle region of a water-cooled gaseous oxygen/gaseous hydrogen rocket thruster at a pressure of 3.45 MPa. The wall temperature measurements in the thruster nozzle in concert with Bartz's correlation are utilized in a one-dimensional model to obtain axial profiles of nozzle wall heat flux.

Santoro, Robert J.↗

An experimental investigation of endwall heat transfer and aerodynamics in a linear vane cascade

The purpose of this experimental investigation was to produce a data base of endwall heat transfer data under conditions that simulate those in the passage of the first-stage stator in advanced turbine engines. The data base is intended to be sufficiently complete to provide verification data for refined computational models, and to provide a basis for advanced core engine endwall cooling designs. A linear, two-dimensional cascade was used to generate the data base. The test plan provided data to examine the effects of exit Mach number, exit Reynolds number, inlet boundary layer thickness, gas-to-wall temperature ratio, inlet pressure gradients, and inlet temperature gradients. The data generated consist of inlet, intrapassage, and exit aerodynamic data plus intrapassage endwall heat flux, adiabatic wall temperature measurements, and inlet turbulence data.

York, R. E.↗

Thermal Analysis of Compressible CO2 Flow for Major Equipment of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. The purpose of this analysis is to determine the discharged CO2 mass from the PFE tank through the Temporary Sleep Station (TeSS) nozzle in reflecting to the latest design of the extended nozzle, and to evaluate the thermal issues associated to the latest nozzle configuration. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 of. In order to investigate the thermal effect on the nozzle due to discharging C02, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 OF, and the TeSS nozzle cover wall temperatures for the three segments are 47 OF, 53 OF and 37 OF, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Michael Y.↗

Thermal Analysis of Compressible CO2 Flow for PFE TeSS Nozzle of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 F. In order to investigate the thermal effect on the nozzle due to discharging CO2, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 F, and the TeSS nozzle cover wall temperatures for the three segments are 47 F, 53 F and 37 F, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Y. Michael↗