Practical Applications for Emerging Plasma-Assisted Combustion Technology
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This presentation highlights early wins, updated progress, and upcoming developments on ‘national-scale shared development platform’ for rapid prototyping, testing and validation of various integrated Mechanical Pod solutions and form factors. Such pod solutions consist of a set of all-electric heat pump mechanical equipment that have integrated functionalities through built-in controls, with heating, cooling, hot water, ventilation (including energy recovery), electrical management, and battery storage within a single package. The presentation draws inspiration from the success of bathroom pods in the US modular construction industry, UK’s efforts with unitizing mechanical systems as ‘utility cupboards’, and VEIC’s early wins in design-build of all-electric Mechanical Pod solutions in Vermont. The presentation includes researchers and partners involved with NREL in Design for Manufacturing and Assembly (DfMA), Virtual Design and Construction (VDC), and digital twin based process optimization modeling of integrated Mechanical Pod solutions. The presentation aims to highlight early wins from such a platform and how various physical and virtual tools are currently being employed as part of NREL’s ongoing multi-year project funded by US DOE. Streamlined procurement, coordination, installation, and O&M of Mechanical Pods such that the majority of work is delegated to the off-site modular factory implies monetary savings. Such a seemingly basic shift in location of the construction process leads to great reduction in complexity, first cost, lead time, and waste, and greater opportunities for innovative compartmentalization and integration of mechanical systems appropriately sized for each apartment or hotel guest room. However, past studies on unitized combination systems show that high installation costs, maintenance issues, challenges with system integration, limitations in existing electrical infrastructure, and lack of architecturally appealing solutions are key barriers. NREL and partners aim to address key barriers through DfMA approach, rapid prototyping and testing, and digital twin process optimization modeling. The presentation is also a call for interested entities to partner with NREL as part of the national-scale development platform, help drive both product and process innovation, and encourage open source sharing of learnings. Learning objectives include (1) learn about the vision of national-scale shared development platform for process-product innovation on integrated mechanical pod solutions and how to get involved, (2) gain an understanding of the components of an all-electric, high performance home, design characteristics and equipment included in an all-electric mechanical pod, integration of mechanical systems within a modular factories’ assembly line, and the system’s commissioning, operation and maintenance. The pre-planning and coordination with the factory and sub-contractors are also highlighted, (3) gain an understanding of using process modeling tools to quantify resource-constrained performance of operations (such as integration of energy efficiency strategies) to manufacture modules of varying design, (4) gain insights on virtual design, rapid prototyping, and emulated testing of various form factors across different climatic conditions. The need for such preliminary testing with open source sharing of learnings will also be highlighted.
Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.
An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.
An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.
QUEST (Q-shu university experiment with steady state spherical tokamak) aims at effective plasma current start-up and stable maintenance of plasma discharge. To solve the inherent problems in a spherical tokamak (ST) arising from insufficient space for placing the inductive center solenoid, electron cyclotron current drive (ECCD) and transient coaxial helicity injection (T-CHI) are implemented as a non-inductive plasma start-up method in QUEST. Efficient ECCD assisted by energetic electrons could be achieved. By combining control of the wave injection angle and application of a negative toroidal electric field, the bulk electron temperature could be raised up to 1 keV due to selective wave power absorption in the bulk electrons. The plasma current of over 50 kA contained within the closed flux surface could be obtained with a floating single biased electrode placed on lower divertor plates for T-CHI. Long-pulse operations on QUEST are impeded frequently due to wall saturation and subsequent density runaway caused by fuel particle imbalance. Since 2014, a unique tool called the ‘hot wall’ has been implemented to overcome the imbalance. The hot wall has a capability to regulate its surface temperature using a heater and two water cooling channels. With the help of the hot wall, 6 h discharges were obtained in 2020. Cooling down of the surface of the hot wall was significantly effective in recovering the wall pumping and was useful to extend the pulse duration. Augmentation of the toroidal magnetic field, B T up to 0.5 T from 0.25 T and a continuous wave (CW) gyrotron of 28 GHz are planned for QUEST in the near future. As raising B T provides a fundamental resonance of electron cyclotron waves (ECWs) with 28 GHz, more effective plasma current start-up and heating will be performed. Long-pulse operations with higher plasma parameters are expected.
This research focuses on twin tower regenerative closed loop desiccant dryers, specifically: blower heater non-purge (BHNP) with and without cooling water pumps, compressed-air heater purge (CHP), blower heater purge (BHP) and pressure swing heaterless (PSH). The research was conducted by collecting and analysing real time current draw data on air compressors and associated dryers at eight different facilities (13 air compressors) in terms of energy, power and cost. A decision tool was developed to depict the operational characteristics (power, energy and cost) of each type of dryer if used in conjunction with the selected compressor system. Finally, this research, on an equivalent normalised basis, compared and contrasted the different types of dryers in terms of performance and cost. Here, the research concluded that of the five types of desiccant dryer types observed the most energy efficient was the BHNP (with cooling water pump), subject to the operational conditions.
Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.
Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.
Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.
Process heating with nuclear energy can reduce greenhouse gas emissions by reducing combustion of fossil fuels in fired heaters as steam boilers. Light water reactors can replace the majority of steam duties used by industry; however, high temperature processes such as steam methane reforming require advanced high temperature reactors. Here, guidance on matching the scale of nuclear reactors with specific industries is provided. Principles of heat transport, temperature boosting, and substitution for hot combustion gases are also discussed in this section.
Abstract An experimental apparatus was constructed to correlate water flowrate and temperature rise under an external band heater. Due to the physical characteristics of the band heater, its transient heating behavior is unknown. This paper investigates the application of inverse heat conduction problem (IHCP) methods to characterize the heat flux from the band heater. Three experiments with different heating times (5, 10, and 20 s) and no flowrate were conducted to measure the transient temperature under the 400 W band heater. Type-T thermocouples measure surface temperature at the centerline of the band heater. The experimental results are computed with five different heat conduction models. The models are chosen to identify how the heat flux response varies from a simplified to a realistic model. Additionally, the results of the experimental heat flux are compared to the manufacturer band heater data (58.9 kW/m2) for each model. The minimum time needed for the heater to fully energize the system is from 10 to 12 s. The residuals for each model are analyzed and used to evaluate the appropriateness of the five different models. The results show that the use of simpler models can achieve results similar to those of complex models, with less time and computational cost.
The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.
The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.
Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.
The purpose of this study is to create a STAR-CCM+ model of a Belowground Vertical Dry Cask Simulator (BVDCS) at Sandia National Laboratories (SNL) and validate the model with SNL’s experimental results. The BVDCS consists of a single boiling water reactor assembly fitted with electric heaters encompassed by a containment vessel and shell to represent a belowground spent nuclear fuel (SNF) dry storage system. Blowers are located near the inlet and outlet of the BVDCS to simulate crosswind conditions. In addition to the experimental results, the STAR-CCM+ model developed for this study is compared with a previous computational fluid dynamics (CFD) model in a different software program, which is used as a software-to-software benchmark. The experimental results provide a dataset to compare the STAR-CCM+ model results for a variety of different conditions. The main objective is to validate and improve STAR-CCM+ CFD models for spent nuclear fuel storage systems with explicitly modeled external environments and “wind driven” crossflows. These CFD models aide in the study of external particle deposition in spent nuclear fuel storage systems, which is important to predicting the significance of chloride induced stress corrosion cracking (CISCC). In addition to experimental comparison, a sensitivity analysis study is performed using the STAR-CCM+ model. The sensitivity analysis provides a quantitative assessment of the sensitivity of various parameters. This helps provide information on various parameters that are of particular importance to constructing a model representative of real life systems. The STAR-CCM+ model compared well to the experimental results showing similar responses to changes in cross wind flow, and a number of parameters are identified for model improvement.
In high-level radioactive waste geological repositories, compacted bentonite undergoes coupled thermo-hydraulic processes due to heat released from a central waste canister and groundwater imbibition from the surrounding host rock. An understanding of these processes is essential for long-term simulations of radionuclide migration and canister corrosion, which requires an understanding of temperature effects on the coupled thermo-hydraulic properties governing these processes. In this study, a tank-scale radial infiltration test was used to investigate water imbibition processes in compacted bentonite under a central heater temperature of 200 °C that simulates high thermal gradients in a repository. Interpretation of this test focuses on evaluation of the liquid water wetting front during hydration and the interpretation of the temperature-dependent transient soil water retention curve (SWRC), thermal conductivity function (TCF), and hydraulic conductivity function (HCF). The SWRC during imbibition follows a temperature-dependent wetting path. Temperature effects on the hydraulic conductivity of bentonite in saturated conditions had the greatest effect on the shape of the HCF, with minimal temperature effects at higher suctions. The transient thermal conductivity data matched well with a new TCF linked with the SWRC shape. Although the bentonite layer was restrained, local deformations during hydration may have affected the shapes of the TCF and HCF.
In June 2018 the team embarked on an ambitious project to address the slow development pace of Alaska’s 20+ billion barrels heavy oil resource via the first ever polymer flood pilot. Following the successful commencement of the pilot in August 2018, the field demonstration, supporting laboratory experiments and numerical simulation have steadily progressed. A significant amount of valuable data and lessons learned have been collected, and are reported in this paper. The ongoing pilot and the research activities is making headway toward the primary objective of validating the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. The pilot is conducted in two pre-existing pairs of horizontal injectors and producers in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field. A customized polymer blending and pumping unit injects HPAM polymer at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP. Supporting coreflood laboratory experiments have focused on quantification of polymer retention in the rock, and effect of injection water salinity, polymer, and their combinations on oil recovery. The injection and production response of the pilot flood pattern is utilized to develop a history matched reservoir simulation model for forecasting oil recovery beyond the pilot. Finally, specially designed laboratory experiments address anticipated operating concerns regarding post-polymer breakthrough such as oil-water separation efficiency and polymer induced fouling of heater tubes. Polymer has been injected continuously since startup except for two short equipment modification shutdowns, and more recently a prolonged disruption due to polymer hydration issues at the J-pad field site. Cumulatively, over 600,000 lbs. of polymer has been injected, corresponding to ~7%PV. The two producers show significant decrease in the water cut, gradually increasing oil rate, and no polymer breakthrough. Two main observations from the coreflood are a significant uncertainty in polymer retention values, and positive oil recovery response to low salinity water (2,600 mg/liter TDS). The heterogeneity in the flood pattern presents some challenges in obtaining a robust history matched simulation model. Experimental results on produced fluids treatment indicate the formation of a dense polymer deposit, at certain conditions, on heating tubes that can negatively impact the heat transfer efficiency. The scientific knowledge, including the lessons learned during unanticipated shutdowns, quality control, logistics and field data that is being acquired from this effort has referential value for other planned EOR projects. Finally, by all indications, the polymer field pilot is steadily progressing toward achieving the ultimate goal of unlocking the massive heavy oil resources on Alaska North Slope (ANS).