Search NASA⌕ Search

SEARCH · Search NASA

Results for “wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Direct comparison of wire, foil, and hybrid X-pinches on a 200 kA, 150 ns current driver

Wire X-pinches (WXPs) have been studied comprehensively as fast (~1 ns pulse width), small (~1 μm) x-ray sources, created by twisting two or more fine wires into an “X” to produce a localized region of extreme magnetic pressure at the cross-point. Recently, two alternatives to the traditional WXP have arisen: the hybrid X-pinch (HXP), composed of two conical electrodes bridged by a thin wire or capillary, and the laser-cut foil X-pinch (LCXP), cut from a thin foil using a laser. We present a comparison of copper wire, hybrid, and laser-cut foil X-pinches on a single experimental platform: UC San Diego’s ~200 kA, 150 ns rise time GenASIS driver. All configurations produced 1–2 ns pulse width, ≤5 μm soft x-ray (Cu L-shell, ~1 keV) sources (resolutions diagnostically limited) with comparable fluxes. WXP results varied with linear mass and wire count, but consistently showed separate pinch and electron-beam-driven sources. LCXPs produced the brightest (~1 MW), smallest (≤5 μm) Cu K-shell sources, and spectroscopic data showed both H-like Cu K α lines indicative of source temperatures ≥2 keV, and cold K α (~8050 eV) characteristic of electron beam generated sources, which were not separately resolved on other diagnostics (within 1–2 ns and ≤200 μm). HXPs produced minimal K-shell emission and reliably single, bright, and small L-shell sources after modifications to shape the early current pulse through them. Benefits and drawbacks for each configuration are discussed to provide potential X-pinch users with the information required to choose the configuration best suited to their needs.

42 ENGINEERING↗

The action-integral and energy to explode short gold wires in ambient air

This paper is about electrically induced explosions of short (1 mm) and thin (38 μm diameter) gold bridgewires in ambient air and contrasts this behavior with that observed for longer wires in a vacuum used in applications such as Z-pinch systems. The action-integral (the time integral of the wire current squared) and energy-to-burst are measured using high current discharge systems. It is found that in contrast to some reports, the action-integral to burst is not a constant for a specific wire geometry and material but, instead, is a function of the rate of current change in the wire around the time of burst and the related metric of the current flux at burst. Furthermore, it is found that the accuracy of the constant action-integral to burst approximation is dependent on the discharge system used. Short gold wires such as these have relevancy to exploding bridgewire detonators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of strain, inter-layer interaction and critical current in CORC ® wires under axial strain by T-A modeling

Superconducting conductors on round core (CORC ® ) cables and wires can meet the needs of large high-field magnets, such as particle accelerators and compact nuclear fusion machines, due to their simple cabling process, high current-carrying capacity and reliable operation under high mechanical stresses. Many high-field magnets require CORC ® cables to carry a current of thousands of amperes in a background magnetic field exceeding 20 T. As a result, the large electromagnetic forces will deform the cable in the axial direction due to hoop stress and in the transverse direction by compressive stress. Therefore, it is essential to determine the irreversible deformation limit of the CORC ® cable under axial tensile load and optimize the cabling parameters to potentially extend this limit. Analytical and numerical methods are developed to assess the performance degradation of CORC ® wires under axial tensile load. The strain level, interlayer contact pressure and friction and their impact on the critical current are calculated by combining the mechanical response and the T-A method. Analyzing the results shows that the winding angle of the tape and the Poisson’s ratio of the inner core are key factors affecting the irreversible tensile strain limit of CORC ® wires. The smaller the winding angle and the higher the Poisson’s ratio of the inner core, the higher the irreversible tensile strain limit. For multi-layer CORC ® wires, the initial contact pressure caused by the cabling process must also be considered. The inter-layer interaction is coupled with the tape strain of each layer. The results of this research can serve as a basis for optimizing and designing CORC ® wires with extended irreversible strain limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An initial magnet experiment using high-temperature superconducting STAR ® wires

A dipole magnet generating 20 T and beyond will require high-temperature superconductors such as Bi 2 Sr 2 CaCu 2 O 8-x and REBa 2 Cu 3 O 7-x (RE = rare earth, rebco). Symmetric tape round (star ® ) wires based on rebco tapes are emerging as a potential conductor for such a magnet, demonstrating a whole-conductor current density of 580 A mm -2 at 20 T, 4.2 K, and at a bend radius of 15 mm. There are, however, few magnet developments using star ® wires. Here we report a subscale canted cos$\theta$ dipole magnet as an initial experiment for two purposes: to evaluate the conductor performance in a magnet configuration and to start developing the magnet technology, leveraging the small bend radius afforded by star ® wires. The magnet was wound with two star ® wires, electrically in parallel and without transposition. We tested the magnet at 77 and 4.2 K. The magnet reached a peak current of 8.9 kA, 78% of the short-sample prediction at 4.2 K, and a whole-conductor current density of 1500 A mm -2 . The experiment demonstrated a minimum viable concept for dipole magnet applications using star ® wires. Here the results also allowed us to identify further development needs for star ® conductors and associated magnet technology to enable high-field rebco magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Protected helical transport in magnetically doped quantum wires: Beyond the one-dimensional paradigm

One-dimensional (1D) quantum wires, which are functionalized by magnetic ad-atoms, can host ballistic helical transport. Helicity protects transport from an undesirable influence of material imperfections and makes the magnetically doped wire very promising elements for nanoelectronics and spintronics. However, fabricating purely 1D conductors is experimentally very challenging and not always feasible. In this paper, we show that the protected helical transport can exist even inquasi-1D wires. We model the quasi-1D magnetically doped wire as two coupled dense 1D Kondo chains. Each chain consists of itinerant electrons interacting with localized quantum magnetic moments - Kondo impurities. We have analyzed the regimes of weak-, intermediate- and strong inter-chain coupling and found conditions necessary for the origin of the aforementioned protected transport. Our results give a push for experimental realizations of the helical states in magnetically doped wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

WIRE SCANNER FOR HIGH INTENSITY BEAM PROFILE DIAGNOSITICS

A control and data acquisition system of a high speed wire scanner is developed for high intensity beam profile diagnostics. The control system of the wire scanner includes two IOCs, a Soft IOC and a VME IOC. The Soft IOC connects with an Aerotech Ensemble motor drive through EPCIS motor record and controls the movement of the wire scanner. An Electrical Input card samples the real-time position of the wire through an incremental encoder, and generates a pulse to synchronize a VME ADC data acquisition card, which digitizes and samples the beam-induced signal after pre-amplification. A VME Relay Output card is installed to control the Brake Solenoid and Actuator Solenoid. All the VME I/O cards are installed on one VME crate and controlled by the VME IOC. The system configuration and software of the wire scanner are under development.

Yan, J.↗

Advantages of Superconducting Device using 26 MgB2 Wire

Superconducting undulator (SCU) which can run at higher temperature than 4 Kelvin range has been anticipated for a long time. However, the performance of high-temperature superconductor (HTS) tapes have not improved over the last decade as the industry mostly concentrates on the cost reduction. Magnesium Diboride (MgB2) has a critical temperature of 39 K and the 1 st generation (1G) wire has been in production but it was not sufficient to be used in SCU. Recently the 2 nd generation (2G) wire has been developed. It is estimated to give a similar performance as NbTi wire at 20K. In this paper the advantages of a SCU with 2G MgB2 wire compared to a conventional SCU with NbTi or Nb3Sn3 wire.

43 PARTICLE ACCELERATORS↗

Processability and Material Behavior of NiTi Shape Memory Alloys Using Wire Laser-Directed Energy Deposition (WL-DED)

Utilizing additive manufacturing (AM) techniques with shape memory alloys (SMAs) like NiTi shows great promise for fabricating highly flexible and functionally superior 3D metallic structures. Compared to methods relying on powder feedstocks, wire-based additive manufacturing processes provide a viable alternative, addressing challenges such as chemical composition instability, material availability, higher feedstock costs, and limitations on part size while simplifying process development. This study presented a novel approach by thoroughly assessing the printability of Ni-rich Ni55.94Ti (Wt. %) SMA using the wire laser-directed energy deposition (WL-DED) technique, addressing the existing knowledge gap regarding the laser wire-feed metal additive manufacturing of NiTi alloys. For the first time, the impact of processing parameters—specifically laser power (400–1000 W) and transverse speed (300–900 mm/min)—on single-track fabrication using NiTi wires in the WL-DED process was examined. An optimal range of process parameters was determined to achieve high-quality prints with minimal defects, such as wire dripping, stubbing, and overfilling. Building upon these findings, we printed five distinct cubes, demonstrating the feasibility of producing nearly porosity-free specimens. Notably, this study investigated the effect of energy density on the printed part density, impurity pick-up, transformation temperature, and hardness of the manufactured NiTi cubes. The results from the cube study demonstrated that varying energy densities (46.66–70 J/mm3) significantly affected the quality of the deposits. Lower to intermediate energy densities achieved high relative densities (>99%) and favorable phase transformation temperatures. In contrast, higher energy densities led to instability in melt pool shape, increased porosity, and discrepancies in phase transformation temperatures. These findings highlighted the critical role of precise parameter control in achieving functional NiTi parts and offer valuable insights for advancing AM techniques in fabricating larger high-quality NiTi components. Additionally, our research highlighted important considerations for civil engineering applications, particularly in the development of seismic dampers for energy dissipation in structures, offering a promising solution for enhancing structural performance and energy management in critical infrastructure.

Dabbaghi, Hediyeh↗

Magnetic Field Sensing via Acoustic Sensing Fiber with Metglas® 2605SC Cladding Wires

Magnetic field sensing has the potential to become necessary as a critical tool for long-term subsurface geophysical monitoring. The success of distributed fiber optic sensing for geophysical characterization provides a template for the development of next generation downhole magnetic sensors. In this study, Sentek Instrument’s picoDAS is coupled with a multi-material single mode optical fiber with Metglas® 2605SC cladding wire inclusions for magnetic field detection. The response of acoustic sensing fibers with one and two Metglas® 2605SC cladding wires was evaluated upon exposure to lateral AC magnetic fields. An improved response was demonstrated for a sensing fiber with in-cladding wire following thermal magnetic annealing (~400 °C) under a constant static transverse magnetic field (~200 μT). A minimal detectable magnetic field of ~500 nT was confirmed for a sensing fiber with two 10 μm cladding wires. The successful demonstration of a magnetic field sensing fiber with Metglas® cladding wires fabricated via traditional draw processes sets the stage for distributed measurements and joint inversion as a compliment to distributed fiber optic acoustic sensors.

Dejneka, Zach (ORCID:0000000179415708)↗

High-temperature strength of refractory-metal wires and consideration for composite applications

Tensile and stress-rupture tests were conducted on wires of W-Hf-C, W-Re-Hf-C, ASTAR 811C (a tantalum alloy), and B-88 (a columbium alloy) at room temperature, 1093 C (2000 F), and 1204 C (2200 F). Metallographic examinations were also made of the wire microstructure after testing. Ultimate tensile strength values up to 2170 meganewtons per square meter (314000 psi) at 1093 C (2000 F) and 1940 meganewtons per square meter (281 000 psi) at 1204 C (2200 F) were obtained for W-Re-Hf-C wire. The best strength values obtained for a 100-hour rupture life were, 1410 meganewtons per square meter (205 000 psi) at 1093 C (2000 F) and 910 meganewtons per square meter (132 000 psi) at 1240 C (2200 F) for W-Re-Hf-C wire. The properties obtained suggested that the wires studied showed promise as potential fiber reinforcement in the 1093 to 1204 C (2000 to 2200 F) temperature range.

Petrasek, D. W.↗

Postulation of the arc restrike mechanisms for exploding wires and tubes.

The many facets of exploding wire restrikes are studied. They are related to the cylindrical shock wave which pumps down the density of the center region of a line energy source or around the surface of the heated wire continuously to a lower density. When the density of any region is pumped down to lower than Paschen's electric breakdown criteria, restrike occurs. The cylindrical shocks occurring in exploding wires are, in general, divided into two types. In the first type the shock is generated by the wire explosion and in the second type the shock is generated by the heat conduction of the wire to the surrounding gas. Application of this mechanism to exploding tubes will enable us to create arc channels in arbitrary gaseous atmospheres with controllable plasma density with the contamination excluded. Neutral density shielded plasma experiments, therefore, can be conducted in a controllable environment.

Cheng, D. Y.↗

Means for accommodating large overstrain in lead wires

An electrical wire is reported along whose length loops are formed at intervals and retained in a plastic capsule that allows unfolding of the loop when tension is exerted on the opposite ends of the wire. The capsule is formed by encompassing each loop with a sleeve of heat shrinkable synthetic plastic material which overlaps the loop and heat shrinking the overlapping portions. Thus, a length of electrical wire is formed which stores extra lengths of wire in the quantity needed to match the expected stretching of materials or elements such as ropes, cords and the like of high elongation to which the electrical wire may be attached.

Rumble, C. V.↗

Method for making a hot wire anemometer and product thereof

A hot wire anemometer probe is described that includes a ceramic body supporting two conductive rods parallel to each other. The body has a narrow edge surface from which the rods protrude. A probe wire is welded to the rods and extends along the edge surface. A ceramic adhesive is used to secure the probe wire to the surface so that the probe wire is rigid. A method for fabricating the probe is also described in which the body is molded and precisely shaped by machining techniques before the probe wires are installed.

Milkulla, V.↗

Selected developments in laser wire stripping

The operation of mechanical and thermal strippers and the early development of laser wire strippers are reviewed. NASA sponsored development of laser wire stripping for space shuttle includes bench-type strippers as well as an advanced portable hand-held stripper which incorporates a miniaturized carbon dioxide laser and a rotating optics unit with a gas-jet assist and debris exhaust. Drives and controls girdle the wire and slit the remaining slug without manual assistance. This unit can strip wire sizes 26 through 12 gage. A larger-capacity hand-held unit for wire sizes through 1/0 gage was built using a neodynium-doped yttrium aluminum garnet (Nd:YAG) laser. The hand-held units have a flexible umbilical cable to an accompanying cart that carries the power supply, gas supply, cooling unit, and the controls.

Source record↗

Laser measuring system for wire-wrapped frame assemblies

The laser measuring system is designed to automatically measure and record the distances between small diameter wires on a wire wrapped grid frame assembly to an accuracy of 0.00635 mm (0.00025 in.). The system utilizes a helium-neon gas laser beam as the measuring instrument with a remote interferometer and retroreflector, a light source and photodetector to detect the wire positions, in conjunction with recording, display and printout units. The laser measuring system is utilized to perform precise automatic measurements for wire application machines or as an automatic feedback device for positioning wires and/or to adjust them for out of tolerance conditions.

Etzel, J. G.↗

Civil helicopter wire strike assessment study. Volume 1: Findings and recommendations

Approximately 208 civil helicopter wire strike accidents for a ten year period 1970 to 1979 are analyzed. It is found that 83% of the wire strikes occurred during bright clear weather. Analysis of the accidents is organized under pilot, environment, and machine factors. Methods to reduce the wire strike accident rate are discussed, including detection/warning devices, identification of wire locations prior to flight, wire cutting devices, and implementation of training programs. The benefits to be gained by implementing accident avoidance methods are estimated to be fully justified by reduction in injury and death and reduction of aircraft damage and loss.

Tuomela, C. H.↗

The Analysis of Turbulent Flow by Hot Wire Signals

When measuring velocities in turbulent gas flow, approximation signal analysis with hot wire anemometers having one and two wire probes are used. A numeric test of standard analyses shows the resulting systemmatic error increases quickly with increasing turbulent intensity. Since it also depends on the turbulence structure, it cannot be corrected. The use of such probes is thus restricted to low turbulence. By means of three wire probes (in two dimensional flows with X wire probes) in principle, instantaneous values of velocity can be determined, and an asymmetric arrangement of wires has a theoretical advantage.

Bartenwerfer, M.↗