Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

A fully coupled two-level Schwarz preconditioner based on smoothed aggregation for the transient multigroup neutron diffusion equations

The neutron multigroup diffusion equations is an important approximation of the neutron transport equation, and has been widely used for studying the motion of neutrons and their interactions with the stationary background materials. Solving the multigroup diffusion equations faces challenging because many variables are coupled together and a lot of computing resources are required. In this paper, we focus on the development of a scalable parallel algorithm framework for the system of equations arising from the discretization of the multigroup diffusion equations using a finite element method in space and using an implicit scheme in time. The parallel agorithm framweork consists of an inexact Jacobian-free Newton for the nonlinear equations, a Krylov subspace method for the Jacobian system and a parallel Schwarz preconditioner for the acceleration of the algorithm convergence. A coarse space based on smoothed aggregation is introduced to construct a two-level method to improve the parallel performance of the Schwarz preconditioner. We numerically shown that compared with the one-level method, the proposed two-level method works significantly better in terms of the number of linear iterations and the compute time for a system of equations with millions of unknowns and a supercomputer with thousands of processors.

97 MATHEMATICS AND COMPUTING↗

Projection-to-Born-improved subtractions at NNLO

While the current frontier in fixed-order precision for collider observables is N 3 LO, important steps are necessary to consolidate NNLO cross-section predictions with improved stability and efficiency. Slicing methods have been successfully applied to obtain NNLO and N 3 LO predictions, but have shown poor performance in the presence of fiducial cuts due to large kinematical power corrections. In this paper we implement Projection-to-Born-improved q T (P2B q T ) and jettiness (P2Bτ 0 ) subtractions for a large class of color singlet processes in MCFM. This method allows for the efficient evaluation of fiducial power corrections in any non-local subtraction scheme using a Projection-to-Born subtraction. We demonstrate the significant numerical improvements of this method based on fiducial Drell-Yan and Higgs cross-sections. Moreover, with fiducial power corrections removed via this method, the leading-logarithmic power corrections that have only been calculated without fiducial cuts can be included, further improving the calculations. For di-photon production with photon isolation, we devise a novel method in combination with P2B-improved subtractions, which we name P2B γ τ 0 , and P2B γ q T for the two subtraction schemes, respectively. This method allows the inclusion of both fiducial power corrections due to kinematic cuts on the photons and a set of isolation power corrections in the fragmentation channel where a quark may enter the isolation cone. We find significant improvements in the convergence of NNLO di-photon cross-sections with photon isolation cuts, demonstrating that it is possible to achieve a stable and efficient calculation of di-photon cross-sections using slicing methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A model and variance reduction method for computing statistical outputs of stochastic elliptic partial differential equations

We present a model and variance reduction method for the fast and reliable computation of statistical outputs of stochastic elliptic partial differential equations. Our method consists of three main ingredients: (1) the hybridizable discontinuous Galerkin (HDG) discretization of elliptic partial differential equations (PDEs), which allows us to obtain high-order accurate solutions of the governing PDE; (2) the reduced basis method for a new HDG discretization of the underlying PDE to enable real-time solution of the parameterized PDE in the presence of stochastic parameters; and (3) a multilevel variance reduction method that exploits the statistical correlation among the different reduced basis approximations and the high-fidelity HDG discretization to accelerate the convergence of the Monte Carlo simulations. The multilevel variance reduction method provides efficient computation of the statistical outputs by shifting most of the computational burden from the high-fidelity HDG approximation to the reduced basis approximations. Furthermore, we develop a posteriori error estimates for our approximations of the statistical outputs. Based on these error estimates, we propose an algorithm for optimally choosing both the dimensions of the reduced basis approximations and the sizes of Monte Carlo samples to achieve a given error tolerance. We provide numerical examples to demonstrate the performance of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge Breeding Application of EBIS/T Devices

The demand of highly charged ions of isotopes from all mass regions of the nuclear chart for low energy experiment or for the post acceleration has driven the development of different charge breeding methods. Charge state breeder employ high charge state ion sources like the Electron Beam Ion Source/Trap (EBIS/T) and the Electron Cyclotron Resonance Ion Source (ECRIS). Existing radioactive beam facilities like REX-ISOLDE or ISAC (TRIUMF) are already using charge state boosters for the post acceleration of radioactive ions. Upcoming facilities like the MSU re-accelerator project, SPIRAL II, SPES, EURISOL and MATS within FAIR have identified the need of a breeding system, because of the demand for highly charged ions at low energies and due to the available budget. Charge state breeding with EBIS/T devices requires several steps, which need to be optimized. A beam of singly charged ions must be prepared prior to injection into an EBIS/T in order to match the acceptance of the electron beam. An efficient injection and short breeding times are required as well as a high abundance in one specific charge state, which can be manipulated in EBIS/T devices. Further issues of charge breeder development are extraction and purification of the wanted highly charged ion species. The present paper will review the efforts of the EBIS/T community and will give an overview of the planned and running facilities.

43 PARTICLE ACCELERATORS↗

Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s{sup 2}). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle-in-cell simulation of laser wakefield accelerators with oblique lasers in quasicylindrical geometry

In the studies of optical injections in laser or beam-driven wakefield accelerators, there is a frequent demand for using obliquely propagating assistant lasers in particle-in-cell simulations. In conventional methods, this is only possible in either two- or three-dimensional Cartesian geometries, which have the drawbacks of either lack of fidelity for the actual situation or requiring a huge amount of computational resources. In this work, we develop a new method that uses an expression-defined oblique laser field to simulate such situations in quasicylindrical geometry particle-in-cell simulations, having the advantages of both maintaining good fidelity and saving computational resources. As an example, we use this method in the scissor-cross ionization injection scheme for the optimization of the injected beam quality. This method is widely applicable to particle injections with assistant lasers in wakefield accelerators, as long as the assistant lasers only influence the injected particles during the injection process. Published by the American Physical Society 2025

Ma, Minghao (ORCID:0009000602317775)↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

ShiftKit

ShiftKit is a modular, science-focused domain adaptation framework for PyTorch, built around clean interfaces for fast implementation of different deep learning architectures, datasets, and domain adaptation methods.

Ciprijanovic, Aleksandra [Fermi National Accelerat↗

High Performance Superconducting Undulator Development

Initial Phase I work has involved a collaborative technical analysis of the superconducting magnet design. ANL has provided CMI with a history of the SCAPE prototype including the short 0.5m wet coil versions as well as thoughts on possible manufacturing methods.

43 PARTICLE ACCELERATORS↗

MO-F-CAMPUS-I-03: GPU Accelerated Monte Carlo Technique for Fast Concurrent Image and Dose Simulation

Purpose: To develop an accurate and fast Monte Carlo (MC) method of simulating CT that is capable of correlating dose with image quality using voxelized phantoms. Methods: A realistic voxelized phantom based on patient CT data, XCAT, was used with a GPU accelerated MC code for helical MDCT. Simulations were done with both uniform density organs and with textured organs. The organ doses were validated using previous experimentally validated simulations of the same phantom under the same conditions. Images acquired by tracking photons through the phantom with MC require lengthy computation times due to the large number of photon histories necessary for accurate representation of noise. A substantial speed up of the process was attained by using a low number of photon histories with kernel denoising of the projections from the scattered photons. These FBP reconstructed images were validated against those that were acquired in simulations using many photon histories by ensuring a minimal normalized root mean square error. Results: Organ doses simulated in the XCAT phantom are within 10% of the reference values. Corresponding images attained using projection kernel smoothing were attained with 3 orders of magnitude less computation time compared to a reference simulation using many photon histories. Conclusion: Combining GPU acceleration with kernel denoising of scattered photon projections in MC simulations allows organ dose and corresponding image quality to be attained with reasonable accuracy and substantially reduced computation time than is possible with standard simulation approaches.

60 APPLIED LIFE SCIENCES↗

Cone Beam Computed Tomography Number Errors and Consequences for Radiotherapy Planning: An Investigation of Correction Methods

Purpose: The potential of keV cone beam computed tomography (CBCT) for guiding adaptive replanning is well-known. There are impediments to this, one being CBCT number accuracy. The purpose of this study was to investigate CBCT number correction methods and the affect of residual inaccuracies on dose deposition. Four different correction strategies were applied to the same patient data to compare performance and the sophistication of correction-method needed for acceptable dose errors. Methods and Materials: Planning CT and CBCT reconstructions were used for 12 patients (6 brain, 3 prostate, and 3 bladder cancer patients). All patients were treated using Elekta linear accelerators and XVI imaging systems. Two of the CBCT number correction methods investigated were based on an algorithm previously proposed by the authors but only previously applied to phantoms. Two further methods, based on an approach previously suggested in the research literature, were also examined. Dose calculations were performed using scans of a 'worst' subset of patients using the Pinnacle{sup 3} version 9.0 treatment planning system and the patients' clinical plans. Results: All mean errors in CBCT number were <50 HU, and all correction methods performed well or adequately in dose calculations. The worst single dose discrepancy identified for any of the examined methods or patients was 3.0%. Mean errors in the doses to treatment volumes or organs at risk were negatively correlated with the mean error in CT number. That is, a mean CT number that was too large, averaged over the entire CBCT volume, implied an underdosing in a volume-of-interest and vice versa. Conclusions: Results suggest that (1) the correction of CBCT numbers to within a mean error of 50 HU in the scan volume provides acceptable discrepancies in dose (<3%) and (2) this is achievable with even quite unsophisticated correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-278: Realization of Dose Verification Tool for IMRT Plan Based On DPM

Purpose: To build a Monte Carlo dose verification tool for IMRT Plan by implementing a irradiation source model into DPM code. Extend the ability of DPM to calculate any incident angles and irregular-inhomogeneous fields. Methods: With the virtual source and the energy spectrum which unfolded from the accelerator measurement data,combined with optimized intensity maps to calculate the dose distribution of the irradiation irregular-inhomogeneous field. The irradiation source model of accelerator was substituted by a grid-based surface source. The contour and the intensity distribution of the surface source were optimized by ARTS (Accurate/Advanced Radiotherapy System) optimization module based on the tumor configuration. The weight of the emitter was decided by the grid intensity. The direction of the emitter was decided by the combination of the virtual source and the emitter emitting position. The photon energy spectrum unfolded from the accelerator measurement data was adjusted by compensating the contaminated electron source. For verification, measured data and realistic clinical IMRT plan were compared with DPM dose calculation. Results: The regular field was verified by comparing with the measured data. It was illustrated that the differences were acceptable (<2% inside the field, 2–3mm in the penumbra). The dose calculation of irregular field by DPM simulation was also compared with that of FSPB (Finite Size Pencil Beam) and the passing rate of gamma analysis was 95.1% for peripheral lung cancer. The regular field and the irregular rotational field were all within the range of permitting error. The computing time of regular fields were less than 2h, and the test of peripheral lung cancer was 160min. Through parallel processing, the adapted DPM could complete the calculation of IMRT plan within half an hour. Conclusion: The adapted parallelized DPM code with irradiation source model is faster than classic Monte Carlo codes. Its computational accuracy and speed satisfy the clinical requirement, and it is expectable to be a Monte Carlo dose verification tool for IMRT Plan. Strategic Priority Research Program of the China Academy of Science(XDA03040000); National Natural Science Foundation of China (81101132)

60 APPLIED LIFE SCIENCES↗

Method for energy dither of a particle beam

A method for varying the wavelength of a free electron laser (FEL) by applying an energy dither to the charged particles supplying the FEL. Bunches of charged particle beams are accelerated by cavities that are operated at a harmonic of the bunch repetition rate. The method involves adding one or more secondary radiofrequency accelerator cavities after the primary beam transport and near the wiggler to apply a fluctuation between individual bunches with a pseudo-random distribution. The secondary radiofrequency accelerator cavities provide fine variations of the beam energy about a nominal operating point. Operating a free electron laser (FEL) with a 1% change in the electron beam energy via the added secondary cavities will result in a 2% wavelength variation of the FEL output.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of the INSTANT-HPS PN Transport Code to the C5G7 Benchmark Problem

INSTANT is the INL's next generation neutron transport solver to support high-fidelity multi-physics reactor simulation INSTANT is in continuous development to extend its capability Code is designed to take full advantage of middle to large cluster (10-1000 processors) Code is designed to focus on method adaptation while also mesh adaptation will be possible. It utilizes the most modern computing techniques to generate a neutronics tool of full-core transport calculations for reactor analysis and design. It can perform calculations on unstructured 2D/3D triangular, hexagonal and Cartesian geometries. Calculations can be easily extended to more geometries because of the independent mesh framework coded with the model Fortran. This code has a multigroup solver with thermal rebalance and Chebyshev acceleration. It employs second-order PN and Hybrid Finite Element method (PNHFEM) discretization scheme. Three different in-group solvers - preconditioned Conjugate Gradient (CG) method, preconditioned Generalized Minimal Residual Method (GMRES) and Red-Black iteration - have been implemented and parallelized with the spatial domain decomposition in the code. The input is managed with extensible markup language (XML) format. 3D variables including the flux distributions are outputted into VTK files, which can be visualized by tools such as VisIt and ParaView. An extension of the code named INSTANTHPS provides the capability to perform 3D heterogeneous transport calculations within fuel pins. C5G7 is an OECD/NEA benchmark problem created to test the ability of modern deterministic transport methods and codes to treat reactor core problems without spatial homogenization. This benchmark problem had been widely analyzed with various code packages. In this transaction, results of the applying the INSTANT-HPS code to the C5G7 problem are summarized.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GPU Acceleration of Large-Scale Full-Frequency GW Calculations

Many-body perturbation theory is a powerful method to simulate electronic excitations in molecules and materials starting from the output of density functional theory calculations. By implementing the theory efficiently so as to run at scale on the latest leadership high-performance computing systems it is possible to extend the scope of GW calculations. Here, we present a GPU acceleration study of the full-frequency GW method as implemented in the WEST code. Excellent performance is achieved through the use of (i) optimized GPU libraries, e.g., cuFFT and cuBLAS, (ii) a hierarchical parallelization strategy that minimizes CPU-CPU, CPU-GPU, and GPU-GPU data transfer operations, (iii) nonblocking MPI communications that overlap with GPU computations, and (iv) mixed precision in selected portions of the code. A series of performance benchmarks has been carried out on leadership high-performance computing systems, showing a substantial speedup of the GPU-accelerated version of WEST with respect to its CPU version. Good strong and weak scaling is demonstrated using up to 25 920 GPUs. Finally, we showcase the capability of the GPU version of WEST for large-scale, full-frequency GW calculations of realistic systems, e.g., a nanostructure, an interface, and a defect, comprising up to 10 368 valence electrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator

Purpose: To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up to 221 MeV. Methods: The spot scanning beam nozzle is modeled using TOPAS code, a simulation tool based on Geant4.9.6. The model contained a beam pipe vacuum window, a beam profile monitor, a drift chamber, two plane-parallel ionization chambers, and a spot-position monitor consisted of a multiwire ionization chamber. A water phantom is located with its upstream surface at the isocenter plane. The initial proton beam energy and anglar deflection are modeled using a Gaussian distribution with FWHM (Full Widths at Half Maximum) deponding on its beam energy. The phase space file (PSF) on a virtual surface located at the center between the two magnets is recorded. PSF is used to analyze the pencil beam features and offset the pencil beam position. The source model parameters are verificated by fitting the simulated Result to the measurement. Results: The simulated percentage depth dose (PDD) and lateral profiles of scanning pencil beams of various incident proton energies are verificated to the measurement. Generally the distance to agreement (DTA) of Bragg peaks is less than 0.2cm. The FWHM of Gaussian anglar distribution was adjusted to fit the lateral profile difference between the simulation and the measurement to less than 2∼3cm. Conclusion: A Monte Carlo model of a spot scanning proton beam was bullt based on a synchrotron proton therapy accelerator. This scanning pencil beam model will be as a block to build the broad proton beam as a proton TPS dose verification tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 2 MV Van de Graaff accelerator as a tool for planetary and impact physics research

Investigating the dynamical and physical properties of cosmic dust can reveal a great deal of information about both the dust and its many sources. Over recent years, several spacecraft (e.g., Cassini, Stardust, Galileo, and Ulysses) have successfully characterised interstellar, interplanetary, and circumplanetary dust using a variety of techniques, including in situ analyses and sample return. Charge, mass, and velocity measurements of the dust are performed either directly (induced charge signals) or indirectly (mass and velocity from impact ionisation signals or crater morphology) and constrain the dynamical parameters of the dust grains. Dust compositional information may be obtained via either time-of-flight mass spectrometry of the impact plasma or direct sample return. The accurate and reliable interpretation of collected spacecraft data requires a comprehensive programme of terrestrial instrument calibration. This process involves accelerating suitable solar system analogue dust particles to hypervelocity speeds in the laboratory, an activity performed at the Max Planck Institut fuer Kernphysik in Heidelberg, Germany. Here, a 2 MV Van de Graaff accelerator electrostatically accelerates charged micron and submicron-sized dust particles to speeds up to 80 km s{sup -1}. Recent advances in dust production and processing have allowed solar system analogue dust particles (silicates and other minerals) to be coated with a thin conductive shell, enabling them to be charged and accelerated. Refinements and upgrades to the beam line instrumentation and electronics now allow for the reliable selection of particles at velocities of 1-80 km s{sup -1} and with diameters of between 0.05 {mu}m and 5 {mu}m. This ability to select particles for subsequent impact studies based on their charges, masses, or velocities is provided by a particle selection unit (PSU). The PSU contains a field programmable gate array, capable of monitoring in real time the particles' speeds and charges, and is controlled remotely by a custom, platform independent, software package. The new control instrumentation and electronics, together with the wide range of accelerable particle types, allow the controlled investigation of hypervelocity impact phenomena across a hitherto unobtainable range of impact parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Clinical Evaluation of a Three-Dimensional Cone-Beam Computed Tomography Estimation Method Using a Deformation Field Map

Purpose: To develop a three-dimensional (3D) cone-beam computed tomography (CBCT) estimation method using a deformation field map, and to evaluate and optimize the efficiency and accuracy of the method for use in the clinical setting. Methods and Materials: We propose a method to estimate patient CBCT images using prior information and a deformation model. Patients' previous CBCT data are used as the prior information, and the new CBCT volume to be estimated is considered as a deformation of the prior image volume. The deformation field map is solved by minimizing deformation energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. This method was implemented in 3D form using hardware acceleration and multi-resolution scheme, and it was evaluated for different scan angles, projection numbers, and scan directions using liver, lung, and prostate cancer patient data. The accuracy of the estimation was evaluated by comparing the organ volume difference and the similarity between estimated CBCT and the CBCT reconstructed from fully sampled projections. Results: Results showed that scan direction and number of projections do not have significant effects on the CBCT estimation accuracy. The total scan angle is the dominant factor affecting the accuracy of the CBCT estimation algorithm. Larger scan angles yield better estimation accuracy than smaller scan angles. Lung cancer patient data showed that the estimation error of the 3D lung tumor volume was reduced from 13.3% to 4.3% when the scan angle was increased from 60 Degree-Sign to 360 Degree-Sign using 57 projections. Conclusions: The proposed estimation method is applicable for 3D DTS, 3D CBCT, four-dimensional CBCT, and four-dimensional DTS image estimation. This method has the potential for significantly reducing the imaging dose and improving the image quality by removing the organ distortion artifacts and streak artifacts shown in images reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refine your search to explore more results.