Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

SU-G-IeP4-06: Feasibility of External Beam Treatment Field Verification Using Cherenkov Imaging

Purpose: Cherenkov light emission has been shown to correlate with ionizing radiation (IR) dose delivery in solid tissue. In order to properly correlate Cherenkov light images with real time dose delivery in a patient, we must account for geometric and intensity distortions arising from observation angle, as well as the effect of monitor units (MU) and field size on Cherenkov light emission. To test the feasibility of treatment field verification, we first focused on Cherenkov light emission efficiency based on MU and known field size (FS). Methods: Cherenkov light emission was captured using a PI-MAX4 intensified charge coupled device(ICCD) system (Princeton Instruments), positioned at a fixed angle of 40° relative to the beam central axis. A Varian TrueBeam linear accelerator (linac) was operated at 6MV and 600MU/min to deliver an Anterior-Posterior beam to a 5cm thick block phantom positioned at 100cm Source-to-Surface-Distance(SSD). FS of 10×10, 5×5, and 2×2cm{sup 2} were used. Before beam delivery projected light field images were acquired, ensuring that geometric distortions were consistent when measuring Cherenkov field discrepancies. Cherenkov image acquisition was triggered by linac target current. 500 frames were acquired for each FS. Composite images were created through summation of frames and background subtraction. MU per image was calculated based on linac pulse delay of 2.8ms. Cherenkov and projected light FS were evaluated using ImageJ software. Results: Mean Cherenkov FS discrepancies compared to light field were <0.5cm for 5.6, 2.8, and 8.6 MU for 10×10, 5×5, and 2×2cm{sup 2} FS, respectably. Discrepancies were reduced with increasing field size and MU. We predict a minimum of 100 frames is needed for reliable confirmation of delivered FS. Conclusion: Current discrepancies in Cherenkov field sizes are within a usable range to confirm treatment delivery in standard and respiratory gated clinical scenarios at MU levels appropriate to standard MLC position segments.

60 APPLIED LIFE SCIENCES↗

R&D ERL: Machine Protection System

The Machine Protection System (MPS) is a device-safety system that is designed to prevent damage to hardware by generating interlocks, based upon the state of input signals generated by selected sub-system. It exists to protect key machinery such as the 50 kW and 1 MW RF Systems. When a fault state occurs, the MPS is capable of responding with an interlock signal within several microseconds. The Machine Protection System inputs are designed to be fail-safe. In addition, all fault conditions are latched and time-stamped. The ERL MPS is based on a National Instruments hardware platform, and is programmed by utilizing National Instruments development environment for a visual programming language.

43 PARTICLE ACCELERATORS↗

Summary of Technologies for National Security Needs

National security needs often require advanced imaging and detection of hidden threats or contraband, a job that can benefit from novel inspection technologies using X-rays or neutrons. In this section we explore the technologies involved in addressing security applications at ports of entry: air, land and sea.

43 PARTICLE ACCELERATORS↗

SENSEI Dark Matter Discovery Project

Researchers at Stony Brook University (Stony Brook) and the Fermi National Accelerator Laboratory (Fermilab) have proposed a new experiment called the Sub-Electron Noise Skipper-CCD Experimental Instrument (SENSEI). Uncovering the identity of dark matter (DM), which makes up about 85% of the matter in the Universe, is among the most important goals of particle physics today. Laboratory-based experimental searches, which have mostly focused on Weakly Interacting Massive Particles (WIMPs) with masses above the GeV-scale (proton mass), have turned up empty thus far. Stony Brook and Fermilab have agreed to provide most of the infrastructure and technical support that will be needed by the collaboration to construct and operate two detectors for the experiment -- SENSEI-10 and SENSEI-100. The Heising-Simons Foundation is providing partial support for the experiment, through a grant to Stony Brook University, which will be used to procure the detector components, support a graduate student to work full-time on the SENSEI experiment, and support travel for collaborators to work on the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the photon detector system for DUNE Vertical Drift TPC

The term DUNE stands for ”Deep Underground Neutrino Experiment”. The program will be carried out as an international, leading-edge, dual-site experiment for neutrino physics and proton decay studies, indeed, the main objective of this experiment is to study long-baseline neutrino oscillations (fig. 1.1)(experiments carried out over the past half century have revealed that neutrinos are found in three states, or flavors, and can transform from one flavor into another. These results indicate that each neutrino flavor state is a mixture of three different nonzero mass states). Moreover, this studies will help us discover more about why matter is more abundant than antimatter (the so called matter-antimatter asymmetry) and DUNE’s capability to collect and analyze neutrino signal from a supernova within the Milky Way would provide a rare opportunity to peer inside a newly formed neutron star and potentially witness the birth of a Black Hole.

47 OTHER INSTRUMENTATION↗

Preparation for DM searches with high Q SRF cavities

This work focuses on the preparatory for two dark matter searches based on high Q SRF cavities. In the context of the SERAPH experiment I participated to experimental work of characterizing the cavity at mK temperature and subsequently analyzed the data collected. For the SHADE experiment, I worked on the preparation of the data analysis starting from the collection of simulated data and built a flexible framework to analyze them. The goal of this report is to present my contribution to these two experiments that are being investigated at Fermilab by the Physics Sensing group at SQMS.

47 OTHER INSTRUMENTATION↗

Six-degree-of-freedom Sensor Fish design and instrumentation

Fish passing through dams may be injured or killed despite advances in turbine design, project operations and other fish bypass systems. The Six-degree-of-freedom (6DOF) Sensor Fish device is an autonomous sensor package designed to characterize the physical conditions and physical stresses fish are exposed to when they pass through complex hydraulic environments. It has been used to identify the locations and operations where conditions are severe enough to injure or kill fish. During the design process, a set of governing equations of motion for the device was derived and simulated in order to understand the design implications of instrument selection and placement within the body of the device. The sensor package includes three rotation sensors, three acceleration sensors, a pressure sensor, and a temperature sensor with a sampling frequency of 2,000 Hz. Its housing is constructed of clear polycarbonate plastic. It is 24.5 mm in diameter and 90 mm in length, weighs about 43 grams, similar to the size and density of a yearling salmon smolt. The relative errors of both the linear acceleration and angular velocity measurements were determined to be less than 5% from laboratory acceptance tests. Since its development in 2005, the 6DOF Sensor Fish device has been successfully deployed at many major dams in the United States.

13 HYDRO ENERGY↗

Detecting alkali-silica reaction in thick concrete structures using linear array ultrasound

The use of concrete structures in commercial nuclear power plants (NPPs) has made its long-term performance crucial for safe operation, especially with license period extensions to sixty years and possibly beyond. Alkali-Silica Reaction (ASR) is a reaction that occurs over time in concrete between alkaline cement paste and reactive, non-crystalline silica (aggregates). In the presence of water, an expansive gel is formed within the aggregates, which results in micro cracks in aggregates and adjacent cement paste. ASR can potentially affect concrete properties and performance characteristics such as compressive strength, modulus of elasticity, flexural stiffness, shear strength, and tensile strength. Currently, no NDE methods have proven effective in identifying ASR before surface cracks form. ASR is usually identified either visibly or by petrographic analysis. While ASR definitely impacts concrete material properties, the performance of concrete structures exhibiting ASR is dependent upon whether or not the concrete is unconfined or confined with reinforcing bars. Confinement by reinforcing bars acts to restrain the expansion of ASR affected concrete similar to pre-stressing, thus improving the performance of a structure. Additionally, there is no direct correlation between the mechanical properties of concrete sample cores and the in-situ properties of the concrete when inside a structure. The University of Tennessee (UTK), along with Oak Ridge National Laboratory and a consortium of universities have developed an accelerated ASR experiment. Three large concrete specimens, representative of NPP infrastructure, were constructed with both embedded and surface instruments. This paper presents preliminary analysis using frequency banded synthetic aperture focusing technique (SAFT).

Ezell, N Dianne↗

Centrifuge with vector-seeking linkage

Technologies pertaining to a centrifuge that comprises a vector-seeking linkage are disclosed herein. In a general embodiment, the centrifuge comprises a spindle that is rotatable about an axis of rotation. The centrifuge also has an arm that is coupled to the spindle, and a vector-seeking linkage that is coupled to the arm. The vector-seeking linkage provides two rotational degrees of freedom with respect to a load coupled to the vector-seeking linkage. The centrifuge is well-suited for a variety of applications, including sensor testing, solution separation, and producing accelerations expected to be experienced during flight.

47 OTHER INSTRUMENTATION↗

Thomson Parabola Spectrometer: a powerful tool to get on-line plasma information

In this contribution we report the results of an experimental measurement performed with a TPS developed at INFN-LNS within the ELIMED project, by means of a powerful and self-consistent technique as a diagnostic tool for the ionic acceleration study in laser-generated-plasmas. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extension of the neutron scatter camera sensitivity to the ~10–200 MeV neutron energy range

The Neutron Scatter Camera (NSC) is a neutron spectrometer and imager that has been developed and improved by the Sandia National Laboratories for several years. Built for special nuclear material searches, the instrument was configured by the design to reconstruct neutron sources within the fission energy range 1–10 MeV. In this work, we present modifications that attempt to extend the NSC sensitivity to neutron energies in the range ~10–200 MeV and discuss the corresponding consequences for the event processing. We present simulation results that manifest important aspects of the NSC response to those intermediate energy neutrons. The simulation results also evidence that the instrument’s spectroscopic capabilities severely deteriorate at those energies, mainly due to the uncertainties in measuring energy, time, and distance between the two neutron scattering interactions. Furthermore, this work is motivated by the need to characterize neutron fluxes at particle accelerators as they may represent important backgrounds for neutrino experiments.

47 OTHER INSTRUMENTATION↗

Development of silicon photomultipliers and their applications to GlueX calorimetry

The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 × 1.2 cm{sup 2}) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a proton microbeam of the PEFP

The PEFP has been developing a 100 MeV proton linear accelerator and user facilities for 20 and 100 MeV proton beams. At one end of the five 20 MeV proton beam lines, a proton microbeam construction was considered for an application in the fields of material, biological, and medical sciences. To develop the proton microbeam, realization of a few MeV proton beam with a few tens of microamperes in diameter of a beam spot was essentially required. In this report, the basic descriptions of the proton microbeam which is composed of an energy degrader, slits, magnetic lens, a target chamber, and detectors are presented including a consideration of unfavorable aspects concerning some specific characteristics of a linear accelerator, such as pulse mode operation and fixed energy. Some calculation results from a Monte Carlo simulation by using the SRIM2006 and the TURTLE codes are also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of a free-electron laser driven by a laser-plasma accelerated beam at Peking University

The percent level energy spread and large divergence of laser-plasma beam are the main challenges of realizing compact short-wavelength free-electron lasers based on laser-plasma accelerators. These issues can be solved with proposed transverse gradient undulator method or bunch decompression method along with proper transport design. We present a study of using an expected 500 MeV laser-plasma beam with 0.3 mm•mrad normalized emittance and 0.3 mrad divergence at Peking University to drive compact free-electron laser at 30 nm. We employ the bunch decompression method with a chromatic matching beamline as well as the transverse gradient undulator method with assumed matched beam. Simulation shows that 700 MW power, 9.7 fs pulse duration and 0.85% relative bandwidth FEL output can be obtained using chromatic matched bunch decompression method. As a result FEL with similar performance can be obtained using the transverse gradient undulator scheme.

47 OTHER INSTRUMENTATION↗

Refine your search to explore more results.