Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

A compact tunable quadrupole lens for brighter and sharper ultra-fast electron diffraction imaging

In this article, we report our proof-of-principle design and experimental commissioning of a broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. The lens system based on electromagnetic (EM) quadrupoles has been built as a part of the existing instrument for ultra-fast electron diffraction (UED) experiments at the Accelerator Test Facility II (ATF-II) at Brookhaven National Laboratory (BNL). We experimentally demonstrated the independent control of the size and divergence of the beam with the charge ranging from 1 to 13 pC. The charge density and divergence of the beam at the sample are the most important factors determining the quality of the Bragg-diffraction image (BDI). By applying the Robust Conjugate Directional Search (RCDS) algorithm for online optimization of the quadrupoles, the transverse beam size can be kept constant down to 75 µm from 1 to 13 pC. The charge density is nearly two orders of magnitude higher than the previously achieved value using a conventional solenoid. Using the BDI method we were able to extract the divergence of the beam in real-time and apply it to the emittance measurement for the first time. Our results agree well with simulations and with the traditional quadrupole scan method. The real-time divergence measurement opens the possibility of online optimization of the beam divergence (< 0.2 mrad) at the sample with the increased beam charge. This optimization is crucial for the future development of single-shot ultra-fast electron microscope (UEM). Finally, we demonstrated BDI with significant improvement, up to 3 times higher peak intensity and 2 times sharper Bragg-diffraction peaks at 13 pC. The charge is now limited by the laser power and increasing charge may improve the quality of BDI further. The capability we demonstrated here provides us with opportunities for new sciences using near-parallel, bright and ultrafast electron beams for single-shot imaging, to directly visualize the dynamics of defects and nanostructured materials, or even record molecular movie, which are impossible using present electron-beam technologies.

43 PARTICLE ACCELERATORS↗

An adaptive approach to machine learning for compact particle accelerators

Abstract Machine learning (ML) tools are able to learn relationships between the inputs and outputs of large complex systems directly from data. However, for time-varying systems, the predictive capabilities of ML tools degrade if the systems are no longer accurately represented by the data with which the ML models were trained. For complex systems, re-training is only possible if the changes are slow relative to the rate at which large numbers of new input-output training data can be non-invasively recorded. In this work, we present an approach to deep learning for time-varying systems that does not require re-training, but uses instead an adaptive feedback in the architecture of deep convolutional neural networks (CNN). The feedback is based only on available system output measurements and is applied in the encoded low-dimensional dense layers of the encoder-decoder CNNs. First, we develop an inverse model of a complex accelerator system to map output beam measurements to input beam distributions, while both the accelerator components and the unknown input beam distribution vary rapidly with time. We then demonstrate our method on experimental measurements of the input and output beam distributions of the HiRES ultra-fast electron diffraction (UED) beam line at Lawrence Berkeley National Laboratory, and showcase its ability for automatic tracking of the time varying photocathode quantum efficiency map. Our method can be successfully used to aid both physics and ML-based surrogate online models to provide non-invasive beam diagnostics.

97 MATHEMATICS AND COMPUTING↗

Highly transferable atomistic machine-learning potentials from curated and compact datasets across the periodic table

Machine learning atomistic potentials trained using density functional theory (DFT) datasets allow for the modeling of complex material properties with near-DFT accuracy while imposing a fraction of its computational cost. The curation of the DFT datasets can be extensive in size and time-consuming to train and refine. In this study, we focus on addressing these barriers by developing minimalistic and flexible datasets for many elements in the periodic table regardless of their mass, electronic configuration, and ground state lattice. These DFT datasets have on average, ~4000 different structures and 27 atoms per structure, which we found sufficient to maintain the predictive accuracy of DFT properties and notably with high transferability. We envision these highly curated training sets as starting points for the community to expand, modify, or use with other machine learning atomistic potential models, whatever may suit individual needs, further accelerating the utilization of machine learning as a tool for material design and discovery.

42 ENGINEERING↗

A compact double-pass Raman backscattering amplifier/compressor

The enhancement of stimulated Raman backscattering (SRBS) amplification was demonstrated by introducing a plasma density gradient along the pump and the seed interaction path and by a novel double-pass design. The energy transfer efficiency was significantly improved to a level of 6.4%. The seed pulse was amplified by a factor of more than 20 000 from the input in a 2 mm long plasma, which also exceeded the intensity of the pump pulse by 2 orders of magnitude. This was accompanied by very effective pulse compression, from 500 fs to 90 fs in the first pass measurements and in the second pass down to approximately 50 fs, as it is indicated by the energy-pulse duration relation. Further improvements to the energy transfer efficiency and the SRBS performance by extending the region of resonance is also discussed where a uniform {approx}4 mm long plasma channel for SRBS was generated by using two subsequent laser pulses in an ethane gas jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact And Robust Laser Impulse Measurement Device, With Ultrashort Pulse Laser Ablation Results

An impulse measurement device and analysis package was conceived, designed, constructed, tested, and demonstrated to be capable of: measuring nanoNewton-seconds to milliNewton-seconds of impulse due to laser-ablation; being transported as carry-on baggage; set-up and tear-down times of less than an hour; target exchange times of less than two minutes (targets can be ablated at multiple positions for thousands of shots); measurements in air and in vacuum; error of just a few percent; repeatability over a wide range of potential systematic error sources; and time between measurements, including ring-down and analysis, of less than 30 seconds. The instrument consists of a cantilever (i.e. leaf spring), whose time-dependent displacement/oscillation is measured and analyzed to determine the impulse imparted by a laser pulse to a target. These shapes are readily/commercially available, and any target material can be used, provided it can be fashioned in the form of a cantilever, or as a coating/film/tape, suitable for mounting on a cantilever of known geometry. The instrument was calibrated both statically and dynamically, and measurements were performed on brass, steel, and Aluminum, using laser pulses of {approx}7 ns, {approx}500 ps, and {approx}500 fs. The results agree well with those published in the literature, with surface effects, atmosphere, and pre-/post-pulses demonstrating interesting effects and indicating areas for further study. These parameters should be carefully controlled and held constant during a series of measurements. The impulse imparted by ablation due to laser filaments in air was also explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel compact high speed x-ray streak camera (invited)

Conventional in-line high speed streak cameras have fundamental issues when their performance is extended below a picosecond. The transit time spread caused by both the spread in the photoelectron (PE) ''birth'' energy and space charge effects causes significant electron pulse broadening along the axis of the streak camera and limits the time resolution. Also it is difficult to generate a sufficiently large sweep speed. This paper describes a new instrument in which the extraction electrostatic field at the photocathode increases with time, converting time to PE energy. A uniform magnetic field is used to measure the PE energy, and thus time, and also focuses in one dimension. Design calculations are presented for the factors limiting the time resolution. With our design, subpicosecond resolution with high dynamic range is expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-flavor CSL phase in compact stars

We suggest a scenario where the three light quark flavors are sequentially deconfined under increasing pressure in cold asymmetric nuclear matter as, e.g., in neutron stars. The basis for our analysis is a chiral quark matter model of Nambu-Jona-Lasinio (NJL) type with diquark pairing in the spin-1 single flavor (CSL), spin-0 two flavor (2SC) and three flavor (CFL) channels. We find that nucleon dissociation sets in at about the saturation density, n{sub 0}, when the down-quark Fermi sea is populated (d-quark dripline) due to the flavor asymmetry induced by {beta}-equilibrium and charge neutrality. At about 3n{sub 0} u-quarks appear and a two-flavor color superconducting (2SC) phase is formed. The s-quark Fermi sea is populated only at still higher baryon density, when the quark chemical potential is of the order of the dynamically generated strange quark mass. We construct two different hybrid equations of state (EoS) using the Dirac-Brueckner Hartree-Fock (DBHF) approach and the EoS by Shen et al. in the nuclear matter sector. The corresponding hybrid star sequences have maximum masses of, respectively, 2.1 and 2.0 M{sub {center_dot}}. Two- and three-flavor quark-matter phases exist only in gravitationally unstable hybrid star solutions in the DBHF case, while the Shen-based EoS produce stable configurations with a 2SC phase component in the core of massive stars. Nucleon dissociation due to d-quark drip at the crust-core boundary fulfills basic criteria for a deep crustal heating process which is required to explain superbusts as well as cooling of X-ray transients.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Mini-Ring project: a compact electrostatic storage ring

The idea of building a small, cheap and transportable electrostatic storage ring emerged in the Lyon and Stockholm groups as a collaborative work in the framework of the ITS-LEIF European network. Such a ring could be devoted to experiments where the ring needs to be transported to different facilities that can deliver exotic particles or means of excitation (e.-g. highly charged ions, X--ray synchrotron...). The design of the so-called Mini-Ring and ion trajectory simulations will be presented. First preliminary results have demonstrated the storage of stable Ar{sup +} ion beams in the millisecond time range. The storage time is presently limited by the poor vacuum conditions (P = 2x10{sup -7} mbar) in the chamber, a feature that is going to be improved in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Compact Dielectric-Loaded Test Accelerator at 11.4 GHz

This paper presents a progress report on the development of a dielectric-loaded test accelerator in the Magnicon Facility at the Naval Research Laboratory (NRL). The accelerator will be powered by an 11.4-GHz magnicon amplifier that provides up to 25 MW of output power in a {approx}250-ns pulse at up to 10 Hz. The accelerator includes a 5-MeV electron injector originally developed at the Tsinghua University in Beijing, China, and can incorporate dielectric-loaded accelerating (DLA) structures of up to 0.5 m in length. The DLA structures are being developed by Argonne National Laboratory and Euclid Techlabs, and shorter test structures fabricated from a variety of dielectric materials have undergone rf testing at NRL at accelerating gradients up to 15 MV/m. The first stage of the accelerator, including the 5-MeV injector, has recently begun operation, and initial operation of the complete dielectric-loaded test accelerator, including injector, DLA test structure, and spectrometer, should take place within the next year.

43 PARTICLE ACCELERATORS↗

A Compact Code for Simulations of Quantum Error Correction in Classical Computers

This study considers implementations of error correction in a simulation language on a classical computer. Error correction will be necessarily in quantum computing and quantum information. We will give some examples of the implementations of some error correction codes. These implementations will be made in a more general quantum simulation language on a classical computer in the language Mathematica. The intention of this research is to develop a programming language that is able to make simulations of all quantum algorithms and error corrections in the same framework. The program code implemented on a classical computer will provide a connection between the mathematical formulation of quantum mechanics and computational methods. This gives us a clear uncomplicated language for the implementations of algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact Detection System for High Sensitivity Hydrogen Profiling of Materials by Nuclear Reaction Analysis

Hydrogen is a ubiquitous contaminant that is known to have dramatic effects on the electrical, chemical, and mechanical properties of many types of materials in even minute quantities. Thus, the detection of hydrogen in materials is of major importance. Nuclear Reaction Analysis (NRA) is a powerful technique for nondestructive profiling hydrogen in materials. However, NRA has found only limited use in many applications because of poor sensitivity due to cosmic ray background (CSRB). Most attempts to eliminate CSRB to achieve ppm detection levels using higher energy nuclear reactions or tons of passive shielding are not compatible with commercial ion beam analysis space and equipment requirements Zimmerman, et al. have previously reported upon a coincidence detector that meets IBA space requirements and reduces the cosmic ray background, but the detector suffers from lower detection efficiency and small sample size. We have replaced the BGO well detector in the Zimmerman coincidence detection scheme with a larger Nal well detector and used faster timing electronics to produce a detector that can handle larger samples with higher detection efficiency, and still eliminate cosmic ray background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research and Development of Compact Neutron Sources based on Inertial Electrostatic Confinement Fusion

Recent progress is described in the research and development of an inertial-electrostatic confinement fusion (IECF) device. Use of a water-cooling jacket with non-uniform thickness shows promising success for landmine detection application, such as effective channeling of neutron flux toward the target and a very stable dc yield in excess of 10{sup 7} D-D neutrons/sec. Addition of an ion source to the conventional glow-discharge-driven IECF enhances the converging deuterium ion energy distribution by allowing a lower operating gas pressure. Improvement in normalized neutron yield, which corresponds to the fusion cross-section averaged over the device radius, by a factor often has been observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a Compact Gamma Tube Interrogation Source

Active interrogation with high-energy monoenergetic gammas can induce photofission signals in fissile materials while minimizing absorbed radiation dose and background from surrounding materials. A first-generation axial-type gamma generator has been developed that utilizes the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction at a 163 keV resonance to produce monoenergetic 12-MeV gamma-rays. The gamma tube employs a water-cooled cylindrical radio frequency (if) induction ion source capable of producing a proton current density of up to 100 mA/cm{sup 2}. The extracted proton beam bombards a lanthanum hexaboride (LaB{sub 6}) target at energies up to 200 keV. The 12-MeV gamma intensity was measured as a function of proton energy, beam current, and angle. Photofission-induced neutrons from depleted uranium (DU) were measured and compared to MCNPX calculations. After extended operation, the high power density of the proton beam was observed to cause damage to the LaB{sub 6} target and the gamma tube improvements currently being made to mitigate this damage are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

A compact electron beam ion source with integrated Wien filter providing mass and charge state separated beams of highly charged ions

A Wien filter was designed for and tested with a room temperature electron beam ion source (EBIS). Xenon charge state spectra up to the charge state Xe{sup 46+} were resolved as well as the isotopes of krypton using apertures of different sizes. The complete setup consisting of an EBIS and a Wien filter has a length of less than 1 m substituting a complete classical beamline setup. The Wien filter is equipped with removable permanent magnets. Hence total beam current measurements are possible via simple removal of the permanent magnets. In dependence on the needs of resolution a weak (0.2 T) or a strong (0.5 T) magnets setup can be used. In this paper the principle of operation and the design of the Wien filter meeting the requirements of an EBIS are briefly discussed. The first ion beam extraction and separation experiments with a Dresden EBIS are presented.

43 PARTICLE ACCELERATORS↗

Compact multiwire proportional counters for the detection of fission fragments

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm{sup 2} and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production of ultradense deuterium: A compact future fusion fuel

Ultradense deuterium as a nuclear fuel in laser-ignited inertial confinement fusion appears to have many advantages. The density of ultradense deuterium D(-1) is as high as 140 kg cm{sup -3} or 10{sup 29} cm{sup -3}. This means that D(-1) will be very useful as a target fuel, circumventing the complex and unstable laser compression stage. We show that the material is stable apart from the oscillation between two forms, and can exist for days in the laboratory environment. We also demonstrate that an amount of D(-1) corresponding to tens of kilojoules is produced in each experiment. This may be sufficient for break-even.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refine your search to explore more results.