Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy

Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages for 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.

60 APPLIED LIFE SCIENCES↗

Consequences of Anatomic Changes and Respiratory Motion on Radiation Dose Distributions in Conformal Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer

Purpose: To determine the effect of interfractional changes in anatomy on the target and normal tissue dose distributions during course of radiotherapy in non-small-cell lung cancer patients. Methods and Materials: Weekly respiration-correlated four-dimensional computed tomography scans were acquired for 10 patients. Original beam arrangements from conventional and inverse treatment plans were transferred into each of the weekly four-dimensional computed tomography data sets, and the dose distributions were recalculated. Dosimetric changes to the target volumes and relevant normal structures relative to the baseline treatment plans were analyzed by dose-volume histograms. Results: The overall difference in the mean {+-} standard deviation of the doses to 95% of the planning target volume and internal target volume between the initial and weekly treatment plans was -11.9% {+-} 12.1% and -2.5% {+-} 3.9%, respectively. The mean {+-} standard deviation change in the internal target volume receiving 95% of the prescribed dose was -2.3% {+-} 4.1%. The overall differences in the mean {+-} standard deviation between the initial and weekly treatment plans was 3.1% {+-} 6.8% for the total lung volume exceeding 20 Gy, 2.2% {+-} 4.8% for mean total lung dose, and 34.3% {+-} 43.0% for the spinal cord maximal dose. Conclusion: Serial four-dimensional computed tomography scans provided useful anatomic information and dosimetric changes during radiotherapy. Although the observed dosimetric variations were small, on average, the interfractional changes in tumor volume, mobility, and patient setup was sometimes associated with dramatic dosimetric consequences. Therefore, for locally advanced lung cancer patients, efforts to include image-guided treatment and to perform repeated imaging during the treatment course are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical Measurement Technologies for High Temperature, Radiation Exposure, and Corrosive Environments—Significant Activities and Findings: In-vessel Optical Measurements for Advanced SMRs

Development of advanced Small Modular Reactors (aSMRs) is key to providing the United States with a sustainable, economically viable, and carbon-neutral energy source. The aSMR designs have attractive economic factors that should compensate for the economies of scale that have driven development of large commercial nuclear power plants to date. For example, aSMRs can be manufactured at reduced capital costs in a factory and potentially shorter lead times and then be shipped to a site to provide power away from large grid systems. The integral, self-contained nature of aSMR designs is fundamentally different than conventional reactor designs. Future aSMR deployment will require new instrumentation and control (I&C) architectures to accommodate the integral design and withstand the extreme in-vessel environmental conditions. Operators will depend on sophisticated sensing and machine vision technologies that provide efficient human-machine interface for in-vessel telepresence, telerobotic control, and remote process operations. The future viability of aSMRs is dependent on understanding and overcoming the significant technical challenges involving in-vessel reactor sensing and monitoring under extreme temperatures, pressures, corrosive environments, and radiation fluxes.

advanced small modular reactors↗

Investigation of Superparamagnetism in Microwave and Conventional Processed Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} Nanoparticles

Nanoparticles of spinel cubic Mn{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4} are first prepared by the coprecipitation method and then subjected to conventional solid-state sintering and microwave processing techniques. Particle sizes are estimated by field emission scanning electron microscopy (FESEM) to be in the nanometer (5–13 nm) range. Transmission electron microscopy (TEM) also supports the FESEM data. The magnetization measurement by vibration sample magnetometry of the conventionally sintered sample shows a paramagnetic nature at room temperature, a superparamagnetic behaviour at low temperature, and a ferromagnetic nature at even lower temperature. The blocking temperature is estimated to be nearly 110 K. Microwave-processed samples show a superparamagnetic nature even at room temperature. The Fe{sup 3+} cations are found at both the sites confirmed by X-ray photoelectron spectroscopy (XPS), are prepared by microwave processing, and have better magnetic properties as compared to the conventionally sintered particles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decoding the Pair Distribution Function of Uranium in Molten Fluoride Salts from X-Ray Absorption Spectroscopy Data by Machine Learning

Thermal properties of actinides in molten salts are linked to the strongly disordered local environment of actinide ions. Here, we illustrate both the limitations of the commonly used fitting method for analysis of extended X-ray absorption fine structure (EXAFS) spectra in molten UF 4 and a possible solution using an "objective neural network - EXAFS" (ONNE) method. ONNE provides both extraction of the pair distribution function, as validated by its application to the EXAFS spectra calculated on molecular dynamics trajectory, and the EXAFS data reconstruction. The ONNE analysis of the molten UF4 has revealed reduction of the first nearest neighbor U-F coordination number, expansion of the U-F bond length and smaller contribution to the second shell compared to its crystalline counterpart. This method is therefore an attractive alternative to conventional EXAFS analysis and molecular dynamics simulations for studies of disordered environment of actinides in molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Far Infrared Synchrotron Near-Field Nanoimaging and Nanospectroscopy

Here, scattering scanning near-field optical microscopy (s-SNOM) has emerged as a powerful imaging and spectroscopic tool for investigating nanoscale heterogeneities in biology, quantum matter, and electronic and photonic devices. However, many materials are defined by a wide range of fundamental molecular and quantum states at far-infrared (FIR) resonant frequencies currently not accessible by s-SNOM. Here we show ultrabroadband FIR s-SNOM nanoimaging and spectroscopy by combining synchrotron infrared radiation with a novel fast and low-noise copper-doped germanium (Ge:Cu) photoconductive detector. This approach of FIR synchrotron infrared nanospectroscopy (SINS) extends the wavelength range of s-SNOM to 31 μm (320 cm –1 , 9.7 THz), exceeding conventional limits by an octave to lower energies. We demonstrate this new nanospectroscopic window by measuring elementary excitations of exemplary functional materials, including surface phonon polariton waves and optical phonons in oxides and layered ultrathin van der Waals materials, skeletal and conformational vibrations in molecular systems, and the highly tunable plasmonic response of graphene.

47 OTHER INSTRUMENTATION↗

In situ study of defect migration kinetics in nanoporous Ag with enhanced radiation tolerance

Defect sinks, such as grain boundaries and phase boundaries, have been widely accepted to improve the irradiation resistance of metallic materials. However, free surface, an ideal defect sink, has received little attention in bulk materials as surface-to-volume ratio is typically low. Here by using in situ Kr ion irradiation technique in a transmission electron microscope, we show that nanoporous (NP) Ag has enhanced radiation tolerance. Besides direct evidence of free surface induced frequent removal of various types of defect clusters, we determined, for the first time, the global and instantaneous diffusivity of defect clusters in both coarse-grained (CG) and NP Ag. Opposite to conventional wisdom, both types of diffusivities are lower in NP Ag. Such a surprise is largely related to the reduced interaction energy between isolated defect clusters in NP Ag. Determination of kinetics of defect clusters is essential to understand and model their migration and clustering in irradiated materials.

NANOSCIENCE AND TECHNOLOGY↗

Crystallization of implanted amorphous silicon during millisecond annealing by infrared laser irradiation

We investigated the homogenous nucleation of crystalline grains in amorphous Si during transient temperature pulse of few milliseconds IR laser irradiation. The crystallized volume fraction is approx80%. Significant crystallization occurs in nonsteady regime because of the rapid temperature variation (10{sup 6} noC/s). Our model combines the time evolution of the crystal grain population with the consumption of the amorphous volume due to the growth of grains. Thanks to the experimental approach based on a laser source to heat alpha-Si and the theoretical model we extended the description of the spontaneous crystallization up to 1323 K or 250 K above the temperature investigated by conventional annealing.

36 MATERIALS SCIENCE↗

Comparison between laser terahertz emission microscope and conventional methods for analysis of polycrystalline silicon solar cell

A laser terahertz emission microscope (LTEM) can be used for noncontact inspection to detect the waveforms of photoinduced terahertz emissions from material devices. In this study, we experimentally compared the performance of LTEM with conventional analysis methods, e.g., electroluminescence (EL), photoluminescence (PL), and laser beam induced current (LBIC), as an inspection method for solar cells. The results showed that LTEM was more sensitive to the characteristics of the depletion layer of the polycrystalline solar cell compared with EL, PL, and LBIC and that it could be used as a complementary tool to the conventional analysis methods for a solar cell.

14 SOLAR ENERGY↗

THE EFFELSBERG-BONN H I SURVEY: DATA REDUCTION

Starting in winter 2008/2009 an L-band seven-feed-array receiver is used for a 21 cm line survey performed with the 100 m telescope, the Effelsberg-Bonn H I survey (EBHIS). The EBHIS will cover the whole northern hemisphere for decl. > - 5{sup 0} comprising both the galactic and extragalactic sky out to a distance of about 230 Mpc. Using state-of-the-art FPGA-based digital fast Fourier transform spectrometers, superior in dynamic range and temporal resolution to conventional correlators, allows us to apply sophisticated radio frequency interference (RFI) mitigation schemes. In this paper, the EBHIS data reduction package and first results are presented. The reduction software consists of RFI detection schemes, flux and gain-curve calibration, stray-radiation removal, baseline fitting, and finally the gridding to produce data cubes. The whole software chain is successfully tested using multi-feed data toward many smaller test fields (1-100 deg{sup 2}) and recently applied for the first time to data of two large sky areas, each covering about 2000 deg{sup 2}. The first large area is toward the northern galactic pole and the second one toward the northern tip of the Magellanic Leading Arm. Here, we demonstrate the data quality of EBHIS Milky Way data and give a first impression on the first data release in 2011.

79 ASTRONOMY AND ASTROPHYSICS↗

An adaptive masking method for beam halo measurement by a digital micro mirror device

We report that in high intensity particle beams, irregularities in cathode emission, scattering effects, dark current and space charge forces can lead to a common phenomenon termed beam halo with associated emittance growth, beam loss and overall beam quality degradation. It is of fundamental interest and practical importance to precisely monitor such beam halo, which could offer valuable insights into the experimental strategy for the suppression of this undesired feature. A Digital Micro mirror Device (DMD) is a computer-controlled micro-electrical-mechanical system that contains a compact array of physically independent reflective mirrors. Using a standard DMD, we come up with an adaptive masking method for halo measurement, which demonstrates superior robustness and efficiency comparing to the conventional approaches as confirmed by simulation and experimental results. Our development includes an integrated package of hardware, software and a graphic user interface (GUI) that is robust and portable and can be applied as a beam halo diagnostic for electron guns or radiating charged particle beams in general.

43 PARTICLE ACCELERATORS↗

CAN STELLAR MIXING EXPLAIN THE LACK OF TYPE Ib SUPERNOVAE IN LONG-DURATION GAMMA-RAY BURSTS?

The discovery of supernovae associated with long-duration gamma-ray burst observations is primary evidence that the progenitors of these outbursts are massive stars. One of the principle mysteries in understanding these progenitors has been the fact that all of these gamma-ray-burst-associated supernovae are Type Ic supernovae with no evidence of helium in the stellar atmosphere. Many studies have focused on whether or not this helium is simply hidden from spectral analyses. In this Letter, we show results from recent stellar models using new convection algorithms based on our current understanding of stellar mixing. We demonstrate that enhanced convection may lead to severe depletion of stellar helium layers, suggesting that the helium is not observed simply because it is not in the star. We also present light curves and spectra of these compact helium-depleted stars compared to models with more conventional helium layers.

79 ASTRONOMY AND ASTROPHYSICS↗

Aharonov-Bohm phases in a quantum LC circuit

We study novel types of contributions to the partition function of the Maxwell system defined on a small compact manifold. These contributions, often not addressed in the perturbative treatment with physical photons, come about as a result of tunneling transitions between topologically distinct but physically identical vacuum winding states. These new terms give an extra contribution to the Casimir pressure, yet to be measured. We argue that this effect is highly sensitive to a small external electric field, which should be contrasted with the conventional Casimir effect, where the vacuum photons are essentially unaffected by any external field. Furthermore, photons will be emitted from the vacuum in response to a time-dependent electric field, similar to the dynamical Casimir effect in which real particles are radiated from the vacuum due to the time-dependent boundary conditions. We also propose an experimental setup using a quantum LC circuit to detect this novel effect. We expect physical electric charges to appear on the capacitor plates when the system dimension is such that coherent Aharonov-Bohm phases can be maintained over macroscopically large distances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-J-149: Beam and Cryostat Scatter Characteristics of the Elekta MR-Linac

Purpose: The Elekta MR-Linac combines a digital linear accelerator system with a 1.5T Philips MRI machine. This study aimed to determine key characteristic information regarding the MR-Linac beam and in particular it evaluated the effect of the MR cryostat on the out of field scatter dose. Methods: Tissue phantom ratios, profiles and depth doses were acquired in plastic water with an IC-profiler or with an MR compatible water tank using multiple system configurations (Full (B0= 1.5T), Full (B0=0T) and No cryostat). Additionally, an in-house CAD based Monte Carlo code based on Penelope was used to provide comparative data. Results: With the cryostat in place and B0=0T, the measured TPR for the MR Linac system was 0.702, indicating an energy of around 7MV. Without the cryostat, the measured TPR was 0.669. For the Full (B0=0T) case, out of field dose at a depth of 10 cm in the isocentric plane, 5 cm from the field edge was 0.8%, 3.1% and 5.4% for 3×3 cm{sup 2}, 10×10 cm{sup 2} and 20×20 cm{sup 2} fields respectively.The out of field dose (averaged between 5 cm and 10 cm beyond the field edges) in the “with cryostat” case is 0.78% (absolute difference) higher than without the cryostat for clinically relevant field sizes (i.e. 10×10 cm{sup 2}) and comparable to measured conventional 6MV treatment beams at a depth of 10 cm (within 0.1% between 5 cm and 6 cm from field edge). At dose maximum and at 5 cm from the field edge, the “with cryostat” out of field scatter for a 10×10 cm{sup 2} field is 1.5% higher than “without cryostat', with a modest increase (0.9%) compared to Agility 6MV in the same conditions. Conclusion: The study has presented typical characteristics of the MR-Linac beam and determined that out of field dose is comparable to conventional treatment beams. All authors are employed by Elekta Ltd., who are developing an MR-Linac.

60 APPLIED LIFE SCIENCES↗

The association between high birth weight and the risks of childhood CNS tumors and leukemia: an analysis of a US case-control study in an epidemiological database

Background: High birth weight (BW), 4000 g or larger, is an established risk factor for childhood leukemia. However, its association with central nervous system (CNS) tumor risk is yet unclear. The present study examined it, analyzing data obtained from a case-control study conducted among three states from the US. The association with childhood leukemia risk was also further examined. Methods: In this study, a data set provided by the Comprehensive Epidemiologic Data Resource was analyzed with an official permission. The original case-control study was conducted to examine the association between paternal preconception exposure to ionizing radiation and childhood cancer risk. Cases with childhood cancer were mainly ascertained from local hospitals, and controls were selected, matched with birth year (1-year category), county of residence, sex, ethnicity and maternal age (+/-2 years). Since the ID numbers were unavailable, conventional logistic analyses were conducted adjusting for those matching variables except for the county of residence. In addition to those variables, gestational age, age at diagnosis and study sites as covariables were included in the logistic models. Results: Analyzed subjects were 72 CNS tumor cases, 124 leukemia cases and 822 controls born from 1945 to 1989. The odds ratios (ORs) of CNS tumor risk for children with low BWs (<2500 g) and high BWs (>4000 g) were 2.0 (95% confidence interval [CI]) = 0.7, 5.9) and 2.5 (95%CI = 1.2, 5.2)], respectively. When high-BW children were restricted to those who were large for gestational age (LGA), the OR for high-BW children remained similar (OR = 2.7; 95%CI = 1.1, 6.2). On the other hand, the ORs of leukemia risk for children with low and high BWs were 0.8 (95%CI = 0.2, 3.0) and 1.4 (95%CI = 0.7, 2.6), respectively. In the normal range of BW (2500–4000 g), higher BW was positively associated with CNS tumor risk (beta = 0.0011, p for trend = 0.012). However, the association with leukemia risk was not significant (beta = -0.0002, p for trend = 0.475). Conclusion: High-BW and LGA children had an elevated childhood CNS tumor risk. In the normal BW range, the BW itself was positively related to CNS tumor risk. No significant association between BW and childhood leukemia risk was observed in this study.

60 APPLIED LIFE SCIENCES↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

Atmospheric absorption measurements in the region of 1 mm wavelength.

A Froome-type plasma-metal-junction device (1962) was used in high-resolution radiation transmission measurements in the atmosphere at wavelengths from 0.5 to 3.0 mm. The experimental and theoretical results for water vapor absorption lines in two submillimeter wavelength windows were compared, showing that this technique provided a much higher wavelength accuracy than more conventional optical-type spectroscopy.

Emery, R.↗

Fabrication of sensitive high Tc bolometers

The rapid change of resistance with temperature of high quality films of high T sub c superconductors can be used to make resistance thermometers with very low temperature noise. Measurements on c-axis yttrium barium copper oxide (YBCO) films have given a spectral intensity of temperature noise less than 4 times 10(exp -8) K/Hz(exp 1/2) at 10 Hz. Consequently, the opportunity exists to make useful bolometric infrared detectors that operate near 90 K which can be cooled with liquid nitrogen. The fabrication and measurement of two bolometer architectures are discussed. The first is a conventional bolometer which consists of a 3000 A thick YBCO film deposited in situ by laser ablation on top of a 500 A thick SrTiO3 thickness and diced into 1x1 mm(exp 2) bolometer chips. Gold black smoke was used as the radiation absorber. The voltage noise was less than the amplifier noise when the film was current biased. Optical measurements gave an NEP of 5 times 10(exp -11) W/Hz(exp 1/2) at 10 Hz. The second architecture is that of an antenna-coupled microbolometer which consists of a small (5x10 cubic microns) YBCO film deposited directly on a bulk substrate with a low thermal conductance (YSZ) and an impedance matched planar lithographed spiral or log-periodic antenna. This structure is produced by standard photolithographic techniques. Measurements gave an electrical NEP of 4.7 times 10(exp -12) W/Hz(exp 1/2) at 10 kHz. Measurements of the optical efficiency are in progress. The measured performance of both bolometers will be compared to other detectors operating at or above liquid nitrogen temperatures so as to identify potential applications.

Nahum, Michael↗

Refine your search to explore more results.