Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Radioactive Waste Management and Environmental Contamination Issues at the Chernobyl Site

The destruction of the Unit 4 reactor at the Chernobyl Nuclear Power Plant resulted in the generation of radioactive contamination and radioactive waste at the site and in the surrounding area (referred to as the Exclusion Zone). In the course of remediation activities, large volumes of radioactive waste were generated and placed in temporary near surface waste-storage and disposal facilities. Trench and landfill type facilities were created from 1986 to 1987 in the Chernobyl Exclusion Zone at distances 0.5 to 15 km from the NPP site. This large number of facilities was established without proper design documentation, engineered barriers, or hydrogeological investigations and they do not meet contemporary waste-safety requirements. Immediately following the accident, a Shelter was constructed over the destroyed reactor; in addition to uncertainties in stability at the time of its construction, structural elements of the Shelter have degraded as a result of corrosion. The main potential hazard of the Shelter is a possible collapse of its top structures and release of radioactive dust into the environment. A New Safe Confinement (NSC) with a 100-years service life is planned to be built as a cover over the existing Shelter as a longer-term solution. The construction of the NSC will enable the dismantlement of the current Shelter, removal of highly radioactive, fuel-containing materials from Unit 4, and eventual decommissioning of the damaged reactor. More radioactive waste will be generated during NSC construction, possible Shelter dismantling, removal of fuel containing materials, and decommissioning of Unit 4. The future development of the Exclusion Zone depends on the future strategy for converting Unit 4 into an ecologically safe system, i.e., the development of the NSC, the dismantlement of the current Shelter, removal of fuel containing material, and eventual decommissioning of the accident site. To date, a broadly accepted strategy for radioactive waste management at the reactor site and in the Exclusion Zone, and especially for high-level and long-lived waste, has not been developed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Point source contamination in CMB non-Gaussianity analyses

In this paper we analyze the biasing effect of point sources, either thermal Sunyaev-Zeldovich clusters or standard radio sources, on the estimated strength of the non-Gaussianity in the cosmic microwave background (CMB). We show that the biggest contribution comes from the cross correlation of the CMB with the matter density rather than from the Poisson term which is conventionally assumed in these calculations. For the three year WMAP data, we estimate that point sources could produce a non-Gaussian signature equivalent to a bias in f{sub NL} of 0.35, 0.24, -0.097, -0.13 in the Ka, Q, V, and W bands, respectively. The level of bias we find is largely insufficient to explain the very high f{sub NL} values recently detected by Yadav and Wandelt. For Planck, we estimate the point source bispectra to contaminate the f{sub NL} estimator with a bias of 1.3, 0.34, -0.25, -0.48 at 30, 44, 70, 100 GHz, respectively. These results depend on the assumed redshift distribution of the point sources. However, given the projected Planck sensitivity of {delta}f{sub NL}{approx_equal}5 (95% C.L.), a good estimate of point sources' properties including their number density and redshift distribution is essential before deriving strong conclusions on primordial non-Gaussianity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contamination cannot explain the lack of large-scale power in the cosmic microwave background radiation

Several anomalies appear to be present in the large-angle cosmic microwave background (CMB) anisotropy maps of the Wilkinson Microwave Anisotropy Probe. One of these is a lack of large-scale power. Because the data otherwise match standard models extremely well, it is natural to consider perturbations of the standard model as possible explanations. We show that, as long as the source of the perturbation is statistically independent of the source of the primary CMB anisotropy, no such model can explain this large-scale power deficit. On the contrary, any such perturbation always reduces the probability of obtaining any given low value of large-scale power. We rigorously prove this result when the lack of large-scale power is quantified with a quadratic statistic, such as the quadrupole moment. When a statistic based on the integrated square of the correlation function is used instead, we present strong numerical evidence in support of the result. The result applies to models in which the geometry of spacetime is perturbed (e.g., an ellipsoidal universe) as well as explanations involving local contaminants, undiagnosed foregrounds, or systematic errors. Because the large-scale power deficit is arguably the most significant of the observed anomalies, explanations that worsen this discrepancy should be regarded with great skepticism, even if they help in explaining other anomalies such as multipole alignments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of instrumental systematic contamination on the lensing mass reconstruction using the CMB polarization

In this paper, we study the effects of instrumental systematics on the reconstruction of the deflection angle power spectrum from weak lensing of cosmic microwave background (CMB) temperature and polarization observations. We consider 7 types of effects which are related to known instrumental systematics: calibration, rotation, pointing, spin-flip, monopole leakage, dipole leakage, and quadrupole leakage. These effects can result in the distortion in the CMB field and can be characterized by 11 distortion fields. Each of these systematic effects can mimic the effective projected matter power spectrum and hence contaminate the lensing reconstruction. To demonstrate the effect of these instrumental systematics on CMB lensing measurements, we consider two types of experiments: one with a detector noise level for polarization of 9.6 {mu}K arcmin and FWHM of 8.0{sup '}, typical of upcoming ground and balloon-based CMB experiments; and a CMBPol-like instrument with a detector noise level for polarization of 2.0 {mu}K arcmin and FWHM of 4.0{sup '}, typical of future space-based CMB experiments. For each systematics field, we consider various choices of coherence scale {alpha}{sub s}, starting from {alpha}{sub s}=10{sup '} to the maximum of {alpha}{sub s}=120{sup '}. Among all the 11 systematic parameters, rotation {omega}, and monopole leakage {gamma}{sub a} and {gamma}{sub b} place the most stringent requirements, while quadrupole leakage q, pointing error p{sub a} and p{sub b}, and calibration a are among the least demanding. The requirements from lensing extraction are about 1-2 orders of magnitude less stringent than the requirements to measure the primordial B modes with an inflationary energy scale of 1.0x10{sup 16} GeV. On the other hand, the requirements for lensing reconstruction are comparable or even more stringent for some systematic parameters than the requirements to detect primordial B modes with an inflationary scale of E{sub i}=3.0x10{sup 16} GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Structure of the dihydrolipoamide succinyltransferase catalytic domain from Escherichia coli in a novel crystal form: a tale of a common protein crystallization contaminant

The crystallization of amidase, the ultimate enzyme in the Trp-dependent auxin-biosynthesis pathway, from Arabidopsis thaliana was attempted using protein samples with at least 95% purity. Cube-shaped crystals that were assumed to be amidase crystals that belonged to space group I 4 (unit-cell parameters a = b = 128.6, c = 249.7 Å) were obtained and diffracted to 3.0 Å resolution. Molecular replacement using structures from the PDB containing the amidase signature fold as search models was unsuccessful in yielding a convincing solution. Using the Sequence-Independent Molecular replacement Based on Available Databases ( SIMBAD ) program, it was discovered that the structure corresponded to dihydrolipoamide succinyltransferase from Escherichia coli (PDB entry 1c4t), which is considered to be a common crystallization contaminant protein. The structure was refined to an R work of 23.0% and an R free of 27.2% at 3.0 Å resolution. The structure was compared with others of the same protein deposited in the PDB. This is the first report of the structure of dihydrolipoamide succinyltransferase isolated without an expression tag and in this novel crystal form.

59 BASIC BIOLOGICAL SCIENCES↗

The advancement of a technique using principal component analysis for the non-intrusive depth profiling of radioactive contamination

A non-intrusive technique using principal component analysis, to infer the depth of the fission fragment caesium-137, when it is buried under silica sand has been described. Using energy variances within different {gamma}-ray spectra, a complete depth model was produced for a single caesium-137 source buried under 1 mm depths ranging between 5-50 mm. This was achieved using a cadmium telluride detector and a bespoke phantom. In this paper we describe the advancement of the technique by further validating it using blind tests for applications outside of the laboratory, where not only the depth (z) but also the surface (x, y) location of {gamma}-ray emitting contamination is often poorly characterised. At present the technique has been tested at the point of maximum activity above the entrained {gamma}-ray emitting source (where the optimal x, y location is known). This is not usually practical in poorly characterized environments where the detector cannot be conveniently placed at such an optimal location to begin with and scanning at multiple points around the region of interest is often required. Using a uniform scanning time, the point of maximum intensity can be located by sampling in terms of total count rate, and converging on this optimal point of maximum intensity. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remediation of subsurface and groundwater contamination with uranium from fuel fabrication facilities at Hanau (Germany)

This paper presents aspects of site decommissioning and clearance of a former fuel fabrication facility (development and production of fuel assemblies for research reactors and HTR) at Hanau (Germany). The main pathways for environmental contamination were deposition on soil surface and topsoil and pollution of deep soil and the aquifer by waste water channel leakage. Soil excavation could be done by classical excavator techniques. An effective removal of material from the saturated zone was possible by using advanced drilling techniques. A large amount of demolished building structure and excavated soil had to be classified. Therefore the use of conveyor detector was necessary. Nearly 100000 Mg of material (excavated soil and demolished building material) were disposed of at an underground mine. A remaining volume of 700 m{sup 3} was classified as radioactive waste. Site clearance started in 2006. Groundwater remediation and monitoring is still ongoing, but has already provided excellent results by reducing the remaining Uranium considerably. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design innovation for the management of alpha contaminated unserviceable glove boxes

With the maturing of nuclear industry, there is an added burden on the Back End of fuel cycle. Radioactive facilities are in the need for refurbishment. This paper describes the steps adopted for managing such alpha contaminated unserviceable Glove Boxes. The first step consisted of in-situ encasement of individual Glove Boxes, encountering the challenges of low head room and space congestion in these laboratories with cognizance to regulatory requirement related to radiation safety. The second step was removal, transfer and placement of encased Glove Boxes in a dedicated facility under continuous surveillance. The glove boxes will remain stored in this facility until arrangements are completed for dismantling and volume reduction in another facility dedicated for this purpose. The final step is the development of an appropriate technique for dismantling/cutting of Glove Boxes in an alpha-tight facility constructed to prevent spread of airborne activity, collection of cut pieces, subsequent decontamination of these metallic wastes and disposal. The paper describes the design scheme for dismantling of the glove box. The description also includes hands on evaluation of tools and gadgets in pilot set-up with a view to incorporating the most credible choice in an upcoming active facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-AB-201-03: Characterization of Electron Beam Out-Of-Field Doses and Neutron Contamination from Modern Varian and Elekta Linear Accelerators

Purpose: To investigate out-of-field electron doses and neutron production from electron beams from modern Varian and Elekta linear accelerators. Methods: Electron dose measurements were made using 10×10cm{sup 2} applicators on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at energies from 6 to 20 MeV. Out-of-field dose profiles and PDD curves were measured in a Wellhofer water phantom using a Farmer chamber. Neutron measurements were made with a combination of moderator buckets and gold activation-foils placed on the treatment couch at various locations in the patient plane on both the 21iX and Versa HD linear accelerators. Results: Electron doses were highest for the highest electron energies. Dose profile curves for the Varian units were found to be lower than those from the Versa HD unit, and were lower than photon beams. Elekta’s dose profiles were higher and exhibited a second dose peak around 20–30 cm from central-axis. Electron doses in this region (0.8–1.3% of dmax at central-axis) were close to 5 times (2.5–4.8) greater than doses from photon beams with similar energies. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Q-values and neutron dose equivalent increased with energy and were typically higher on central-axis. 18 MV photon beam neutron dose equivalents were greater than any electron beam, being approximately 40 times greater than for the 20 MeV electron beam (21iX). Conclusion: The Versa HD exhibited higher than expected out-of-field electron doses in comparison to typical radiotherapy photon beams. Fortunately, out-of-field electron doses can be substantially reduced by applying a water-equivalent bolus with thickness of E(MeV)/4 in cm. Neutron contamination from clinical electron beams can be considered negligible in relation to photon beams but may need to be considered for special cases. This work was supported by Public Health Service Grant CA180803 awarded by the National Cancer Institute, United States Department of Health and Human Services.

07 ISOTOPE AND RADIATION SOURCES↗

Diversity, abundance, and consistency of microbial oxygenase expression and biodegradation in a shallow contaminated aquifer

The diversity of Rieske dioxygenase genes and short-term temporal variability in the abundance of two selected dioxygenase gene sequences were examined in a naphthalene-rich, coal tar waste-contaminated subsurface study site. Using a previously published PCR-based approach (S. M. Ni Chadhain, R. S. Norman, K. V. Pesce, J. J. Kukor, and G. J. Zylstra, Appl. Environ. Microbiol. 72: 4078-4087, 2006) a broad suite of genes was detected, ranging from dioxygenase sequences associated with Rhodococcus and Sphingomonas to 32 previously uncharacterized Rieske gene sequence clone groups. The nag genes appeared frequently (20% of the total) in two groundwater monitoring wells characterized by low (similar to 10{sup 2} ppb; similar to 1 {mu} M) ambient concentrations of naphthalene. A quantitative competitive PCR assay was used to show that abundances of nag genes (and archetypal nah genes) fluctuated substantially over a 9-month period. To contrast short-term variation with long-term community stability, in situ community gene expression (dioxygenase mRNA) and biodegradation potential (community metabolism of naphthalene in microcosms) were compared to measurements from 6 years earlier. cDNA sequences amplified from total RNA extracts revealed that nah- and nag-type genes were expressed in situ, corresponding well with structural gene abundances. Despite evidence for short-term (9-month) shifts in dioxygenase gene copy number, agreement in field gene expression (dioxygenase mRNA) and biodegradation potential was observed in comparisons to equivalent assays performed 6 years earlier. Thus, stability in community biodegradation characteristics at the hemidecadal time frame has been documented for these subsurface microbial communities.

01 COAL, LIGNITE, AND PEAT↗

Dismantling of the PETRA glove box: tritium contamination and inventory assessment

The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followed by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for determining coal carbon in the reclaimed minesoils contaminated with coal

Minesoils developed on the reclaimed surface-mined sites for coal are contaminated with coal particles resulting from mining and reclamation activities. Therefore, the total organic carbon (TOC) pool in these sites is a mixture of coal and plant-derived recent soil organic carbon (SOC). Accurate estimates of SOC pools and C sequestration rates in the reclaimed minesoils (RMS) is limited by the lack of a standard and cost-effective method for determination of coal C concentrations in the RMS. The chemi-thermal method, based on the oxidative resistance of coal, was developed and validated with radiocarbon analysis using selected artificial soil-coal mixtures and minesoil samples. Radiocarbon analysis of RMS samples indicated that minesoils from the top 10-cm depth developing from topsoil applied during reclamation was coal C free. The contribution of coal C and the radiocarbon age of TOC increased with increasing soil depth. The coal C fraction accounted for 0 to 92% of TOC in the RMS samples. The coal C fraction was highly correlated with {delta}{sup 13}C (r{sup 2} = 0.84), suggesting that stable isotope composition could estimate the coal C concentration in RMS samples. Analysis of coal and artificial soil and coal mixtures indicated that chemi-thermal treatment was effective in removing recent SOC with minimum effect on coal. Analysis of RMS samples indicated that both radiocarbon activity and the chemi-thermal method were effective in estimating coal C concentration in RMS of southeast Ohio. The coal C concentrations for both methods were highly correlated (r{sup 2} = 0.95), suggesting that the chemi-thermal method was as effective as radiocarbon activity measurement in estimating coal C concentration in these soils.

01 COAL, LIGNITE, AND PEAT↗

Influence of Wetting and Mass Transfer Properties of Organic Chemical Mixtures in Vadose Zone Materials on Groundwater Contamination by Nonaqueous Phase Liquids

Previous studies have found that organic acids, organic bases, and detergent-like chemicals change surface wettability. The wastewater and NAPL mixtures discharged at the Hanford site contain such chemicals, and their proportions likely change over time due to reaction-facilitated aging. The specific objectives of this work were to (1) determine the effect of organic chemical mixtures on surface wettability, (2) determine the effect of organic chemical mixtures on CCl4 volatilization rates from NAPL, and (3) accurately determine the migration, entrapment, and volatilization of organic chemical mixtures. Five tasks were proposed to achieve the project objectives. These are to (1) prepare representative batches of fresh and aged NAPL-wastewater mixtures, (2) to measure interfacial tension, contact angle, and capillary pressure-saturation profiles for the same mixtures, (3) to measure interphase mass transfer rates for the same mixtures using micromodels, (4) to measure multiphase flow and interphase mass transfer in large flow cell experiments, all using the same mixtures, and (5) to modify the multiphase flow simulator STOMP in order to account for updated P-S and interphase mass transfer relationships, and to simulate the impact of CCl4 in the vadose zone on groundwater contamination. Results and findings from these tasks and summarized in the attached final report.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 547: Miscellaneous Contaminated Waste Sites, Nevada National Security Site, Nevada, Revision 0

The purpose of this CADD/CAP is to present the corrective action alternatives (CAAs) evaluated for CAU 547, provide justification for selection of the recommended alternative, and describe the plan for implementing the selected alternative. Corrective Action Unit 547 consists of the following three corrective action sites (CASs): (1) CAS 02-37-02, Gas Sampling Assembly; (2) CAS 03-99-19, Gas Sampling Assembly; and(3) CAS 09-99-06, Gas Sampling Assembly. The gas sampling assemblies consist of inactive process piping, equipment, and instrumentation that were left in place after completion of underground safety experiments. The purpose of these safety experiments was to confirm that a nuclear explosion would not occur in the case of an accidental detonation of the high-explosive component of the device. The gas sampling assemblies allowed for the direct sampling of the gases and particulates produced by the safety experiments. Corrective Action Site 02-37-02 is located in Area 2 of the Nevada National Security Site (NNSS) and is associated with the Mullet safety experiment conducted in emplacement borehole U2ag on October 17, 1963. Corrective Action Site 03-99-19 is located in Area 3 of the NNSS and is associated with the Tejon safety experiment conducted in emplacement borehole U3cg on May 17, 1963. Corrective Action Site 09-99-06 is located in Area 9 of the NNSS and is associated with the Player safety experiment conducted in emplacement borehole U9cc on August 27, 1964. The CAU 547 CASs were investigated in accordance with the data quality objectives (DQOs) developed by representatives of the Nevada Division of Environmental Protection (NDEP) and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAU 547. Existing radiological survey data and historical knowledge of the CASs were sufficient to meet the DQOs and evaluate CAAs without additional investigation. As a result, further investigation of the CAU 547 CASs was not required. The following CAAs were identified for the gas sampling assemblies: (1) clean closure, (2) closure in place, (3) modified closure in place, (4) no further action (with administrative controls), and (5) no further action. Based on the CAAs evaluation, the recommended corrective action for the three CASs in CAU 547 is closure in place. This corrective action will involve construction of a soil cover on top of the gas sampling assembly components and establishment of use restrictions at each site. The closure in place alternative was selected as the best and most appropriate corrective action for the CASs at CAU 547 based on the following factors: (1) Provides long-term protection of human health and the environment; (2) Minimizes short-term risk to site workers in implementing corrective action; (3) Is easily implemented using existing technology; (4) Complies with regulatory requirements; (5) Fulfills FFACO requirements for site closure; (6) Does not generate transuranic waste requiring offsite disposal; (7) Is consistent with anticipated future land use of the areas (i.e., testing and support activities); and (8) Is consistent with other NNSS site closures where contamination was left in place.

54 ENVIRONMENTAL SCIENCES↗

Fixation of Radiological Contamination; International Collaborative Development

A cooperative international project was conducted by the Idaho National Laboratory (INL) and the United Kingdom’s National Nuclear Laboratory (NNL) to integrate a capture coating with a high performance atomizing process. The initial results were promising, and lead to further trials. The somewhat longer testing and optimization process has resulted in a product that could be demonstrated in the field to reduce airborne radiological dust and contamination.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results For The Fourth Quarter 2014 Tank 50 WAC Slurry Sample: Chemical And Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the Calendar Year (CY) 2014 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the First, Second, and Third Quarter Calendar Year 2015 Tank 50H WAC slurry samples chemical and radionuclide contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the Calendar Year (CY) 2015 First, Second, and Third Quarter sampling of Tank 50H for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering (D&S-FE) to support the transfer of low-level aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50H Waste Characterization System. Previous memoranda documenting the WAC analyses results have been issued for these three samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refine your search to explore more results.