Boron-10 Lined Proportional Counter Model Validation

The decreasing supply of 3He is stimulating a search for alternative neutron detectors; one potential 3He replacement is 10B-lined proportional counters. Simulations are being performed to predict the performance of systems designed with 10B-lined tubes. Boron-10-lined tubes are challenging to model accurately because the neutron capture material is not the same as the signal generating material. Thus, to simulate the efficiency, the neutron capture reaction products that escape the lining and enter the signal generating fill gas must be tracked. The tube lining thickness and composition are typically proprietary vendor information, and therefore add additional variables to the system simulation. The modeling methodologies used to predict the neutron detection efficiency of 10B-lined proportional counters were validated by comparing simulated to measured results. The measurements were made with a 252Cf source positioned at several distances from a moderated 2.54-cm diameter 10B-lined tube. Models were constructed of the experimental configurations using the Monte Carlo transport code MCNPX, which is capable of tracking the reaction products from the (n,10B) reaction. Several different lining thicknesses and compositions were simulated for comparison with the measured data. This paper presents the results of the evaluation of the experimental and simulated data, and a summary of how the different linings affect the performance of a coincidence counter configuration designed with 10B-lined proportional counters.

Lintereur, Azaree T.↗

A Comparison of Adaptive and Template Matching Techniques for Radio-Isotope Identification

We compare and contrast the effectiveness of a set of adaptive and non-adaptive algorithms for isotope identi cation based on gamma-ray spectra. One dimensional energy spectra are simulated for a variety of dwell-times and source to detector distances in order to reflect conditions typically encountered in radiological emergency response and environmental monitoring applications. We nd that adaptive methods are more accurate and computationally efficient than non-adaptive in cases of operational interest.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-293: Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers

Purpose: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). Methods: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position was calculated according to the breathing cycle. The dose to the MD region was obtained through accumulating the treatment planning system calculated doses at different positions in a breathing cycle. A phantom experiment was then conducted to validate the calculated results using a motion phantom (The CIRS ‘Dynamic’ Thorax Phantom). The simulated breathing pattern used a cos4(x) curve with an amplitude of 10mm. A 3-D conformal 7-field plan with 6X energy was created and the dose was calculated in the average intensity projection (AIP) simulation CT images. Both films (EBT2) and optically stimulated luminescence (OSL) detectors were inserted in the target of the phantom to measure the dose during radiation delivery (Varian Truebeam) and results were compared to planning dose parameters. Results: The Gamma analysis (3%/3mm) between measured dose using EBT2 film and calculated dose using AIP was 80.5%, indicating substantial dosimetric differences. While the Gamma analysis (3%/3mm) between measured dose using EBT2 and accumulated dose using 4D-CT was 98.9%, indicating the necessity of dose accumulation using 4D-CT. The measured doses using OSL and theoretically calculated doses using probability distribution function at the corresponding position were comparable. Conclusion: Use of static dose calculation in the treatment planning system could substantially underestimate the actually delivered dose in the MD region for a moving target. Funding Supported by NSFC, No.81372436.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-10: Molecular Imaging with Clinical X-Ray Sources and Compton Cameras

Purpose: The application of Compton cameras (CC) is a novel approach translating XFCT to a practical modality realized with clinical CT systems without the restriction of pencil beams. The dual modality design offers additional information without extra patient dose. The purpose of this work is to investigate the feasibility and efficacy of using CCs for volumetric x-ray fluorescence (XF) imaging by Monte Carlo (MC) simulations and statistical image reconstruction. Methods: The feasibility of a CC for imaging x-ray fluorescence emitted from targeted lesions is examined by MC simulations. 3 mm diameter water spheres with various gold concentrations and detector distances are placed inside the lung of an adult human phantom (MIRD) and are irradiated with both fan and cone-beam geometries. A sandwich design CC composed of Silicon and CdTe is used to image the gold nanoparticle distribution. The detection system comprises four 16×26 cm{sup 2} detector panels placed on the chest of a MIRD phantom. Constraints of energy-, spatial-resolution, clinical geometries and Doppler broadening are taken into account. Image reconstruction is performed with a list-mode MLEM algorithm with cone-projector on a GPU. Results: The comparison of reconstruction of cone- and fan-beam excitation shows that the spatial resolution is improved by 23% for fan-beams with significantly decreased processing time. Cone-beam excitation increases scatter content disturbing quantification of lesions near the body surface. Spatial resolution and detectability limit in the center of the lung is 8.7 mm and 20 fM for 50 nm diameter gold nanoparticles at 20 mGy. Conclusion: The implementation of XFCT with a CC is a feasible method for molecular imaging with high atomic number probes. Given constrains of detector resolutions, Doppler broadening, and limited exposure dose, spatial resolutions comparable with PET and molecular sensitivities in the fM range are realizable with current detector technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Measurement of Plutonium in Spent Fuel with X-ray Fluoresence

Currently, the only NDA technique that directly measures Pu in SNF involves XRF measurements. Measurements and simulations were used to demonstrate that with a properly - 15 - configured detector system, it is feasible to measure the Pu/U atom ratio at the surface of a fuel pin using measurements of the 103.7 keV K X-ray from Pu. Since the Pu/U atom ratio at the surface of the pin is directly related to the average Pu/U concentration for the pin, the technique might be applicable to measuring the Pu/U concentration in an LWR spent fuel pin. However, the technique requires knowledge of the fuel pin design and operating history to properly correlate surface Pu to average Pu for a pin. Fuel history information is available from operator declarations and can be verified by complementary measurements including gamma spectroscopy and passive gross neutron counts. While the count times of 4 to 12 hours used in these measurements were longer than would be acceptable in most applications, efforts are being made to improve counting time. These include the use of a segmented HPGe detector and reduction of Compton scattering background. These measurements are useful for individual fuel pins and provide a complementary, validating measurement for full assembly techniques. For future work, optimized detector systems and measurement approaches will be explored with the goal of measuring the Pu/U X-ray ratio with shorter count times. Measurements will be compared with the results of destructive analysis, which is to be completed this year, to provide a correlation between the measured Pu/U ratio and the total Pu/U ratio in the fuel. In addition, the sensitivity of this method to variations in system parameters will be studied to determine the expected accuracy of the technique.

Romano, Catherine E.↗

Evaluation of Various Collimators for UF6 Gas Pipe Measurement

On-line gamma measurements of the enrichment of uranium in UF6 gas in pipes is carried out as part of international safeguards. The 186 keV line from 235 U is measured in NaI detectors. One complication in the analysis is that the 186 keV line also comes from the (time-dependent) amount of uranium-bearing material deposited on the interior walls of the pipe. This contribution has to be subtracted before the enrichment of the gas can be calculated. The relative contributions to the total 186 keV count rate from the gas and from the deposit depends on the amount of deposit, but also on the type of collimation/shielding used between the NaI detector and the gas pipe. Several different collimation/shielding designs have been simulated in order to determine which provides the best performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Measurements on the Neutrino Mass: KATRIN and Project 8 (Final Technical Report for DE-SC0014130)

The overarching goal of the funded research is to build experiments and develop techniques towards the major goal of measuring the mass of the neutrino, particularly by the method of high-resolution spectroscopy of the endpoint of tritium. The goals of this project were to make hardware and intellectual contributions towards the KATRIN experiment, an international project under construction in Germany, and towards the "Project 8" R&D program to develop new electron spectroscopy methods and apply them to tritium. A minor goal of the project was to support simulation work and R&D on future neutrino and dark matter detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reaction Rate Ratios for Recent Fast Metal Experiments with Large Plutonium Masses

Reaction rate ratios are integral responses that are used within the criticality experiments field because they contain spectral information. While these types of measurements have been utilized for nuclear data validation with historic experiments, few experiments of this type have been utilized for recent experiments, as few exist. This work focuses on measured reaction rate ratios for two nearly bare plutonium critical assemblies with different geometries: one that is cube like (with a Pu mass of 40 kg) and one that is slab like (with a Pu mass of 109 kg). Irradiations were performed with both configurations in which foils were placed near the center of the assembly. Plutonium, highly enriched uranium, depleted uranium, and Au foils were included in the irradiation and counted via high-purity germanium detectors. From these measurements, reaction rate ratios were calculated. Measured and simulated values and uncertainties are presented for the reaction rate ratios. Ratios utilizing the following reactions are given in this work: 197 Au(n, γ), 197 Au(n,2n), 235 U(n,fission), 238 U(n, fission), 238 U(n,2n), 238 U(n,γ), and 239 Pu(n,fission). Uncertainties for the measured reaction rate ratios ranged from 4% to 7%, and the contribution of various parameters to this uncertainty was investigated. The results are compared to historical experiments and should be used for nuclear data validation for future nuclear data library releases. These measurements are part of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project, which utilizes measurement responses in addition to k eff (such as these reaction rate ratios) to help reduce uncertainties in 239 Pu nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A cosmic dust composition analyzed with a spark ion source

Simulated iron micrometeoroids were fired unto a capacitor-type micrometeoroid detector which responded to an impact with a spark. Large ion currents were extracted from the spark and analyzed in a crude ion time-of-flight mass spectrometer. The mass spectra show the elements of both detector and particle materials.

Auer, S.↗

High resolution Doppler lidar

A high resolution lidar system was implemented to measure winds in the lower atmosphere. The wind speed along the line of sight was determined by measuring the Doppler shift of the aerosol backscattered laser signal. The system in its present configuration is stable, and behaves as indicated by theoretical simulations. This system was built to demonstrate the capabilities of the detector system as a prototype for a spaceborne lidar. The detector system investigated consisted of a plane Fabry-Perot etalon, and a 12-ring anode detector. This system is generically similar to the Fabry-Perot interferometer developed for passive wind measurements on board the Dynamics Explorer satellite. That this detector system performs well in a lidar configuration was demonstrated.

Abreu, Vincent J.↗

Monitoring of Time-Dependent System Profiles by Multiplex Gas Chromatography with Maximum Entropy Demodulation

The maximum entropy technique was successfully applied to the deconvolution of overlapped chromatographic peaks. An algorithm was written in which the chromatogram was represented as a vector of sample concentrations multiplied by a peak shape matrix. Simulation results demonstrated that there is a trade off between the detector noise and peak resolution in the sense that an increase of the noise level reduced the peak separation that could be recovered by the maximum entropy method. Real data originated from a sample storage column was also deconvoluted using maximum entropy. Deconvolution is useful in this type of system because the conservation of time dependent profiles depends on the band spreading processes in the chromatographic column, which might smooth out the finer details in the concentration profile. The method was also applied to the deconvolution of previously interpretted Pioneer Venus chromatograms. It was found in this case that the correct choice of peak shape function was critical to the sensitivity of maximum entropy in the reconstruction of these chromatograms.

Becker, Joseph F.↗

Counterintuitive MCNPX Results for Scintillator Surface Roughness Effect

We have reported on our recent MCNPX simulation results of energy deposition for a group of 8 scintillation detectors, coupled with various rough surface patterns. The MCNPX results generally favored the detectors with various rough surface patterns. The observed MCNPX results are not fully explained by this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The exposure of the hybrid detector of the Pierre Auger Observatory

The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The 'hybrid' detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Charge Detector for the Imaging Calorimeter for ACCESS (ICA)

NASA's Advanced Cosmic Ray Experiment for the Space Station (ACCESS) Mission is planned to consist of a transition radiation detector (TRD) and a thin ionization calorimeter. In order to measure the charge of the primary cosmic ray, it is necessary for the calorimeter to have its own charge detector. Silicon detectors are chosen for the charge detector because of their excellent resolution, small size and nearly square shape. Monte Carlo simulations are performed to find the probability of misidentifying protons as alpha particles due to backscattered radiation from the calorimeter. Simulations were also used to investigate identifying primary cosmic rays that fragmented in the TRD before reaching the calorimeter. For this study algorithms have been developed for determining a direction of the core shower in the calorimeter. These algorithms are used to find the approximate location of the primary particle in the silicon detectors. Results show the probability to misidentify the charge depends upon the energy and direction of the primary particles.

Lee, Jeongin↗

Étude et simulation de la lumière de scintillation produite et se propageant dans une chambre à dérive double-phase à argon liquide, dans le contexte du projet DUNE

DUNE is a future long-baseline neutrino experiment designed to determine, among others, the neutrino mass hierarchy and to measure the CP violation phase that enters the neutrino oscillation process. This project is based on a 1300 km long high intensity neutrino beam and a massive detector containing more than 40 kilotons of liquid argon using the liquid argon time projection chamber technology (LArTPC). Two approaches of this technology are currently under development, leading to the construction of two prototypes to be in place at the end of 2018 at CERN. The work of this thesis is part of the ProtoDUNE-DP project, which aims at probing the capabilities of the so-called “dual-phase” technology, that uses both gaseous and liquid argon, for a large-scale detector. Two kind of signals, a charge signal and a scintillation light signal, are expected in a LArTPC. The light signal can be used as a trigger, for the identification and rejection of the cosmic background, and for precise calorimetric measurements. Prior simulations of this signal are needed in order to improve our understanding of the scintillation light signal and to develop the identification algorithms. This work addresses the development of this simulation and the study of the scintillation photon behavior in the liquid argon detector. The different scintillation light production mechanisms, the developed simulation and the different studies on the light propagation in ProtoDUNE-DP are presented. These simulations have also been compared with light data taken at CERN in 2017 with a first demonstrator, in order to validate and tune the simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos

Herein, this article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a first- ever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications. During its first phase, the detector will provide a critical large-scale test of the ability to tag neutrons and thus distinguish low energy electron neutrinos and antineutrinos. This would make WATCHMAN the only detector capable of providing both direction and flavor identification of supernova neutrinos. It would also be the third largest supernova detector, and the largest underground in the western hemisphere. In a follow-on phase incorporating the IsoDAR neutrino beam, the detector would have world-class sensitivity to sterile neutrino signatures and to non-standard electroweak interactions (NSI). WATCHMAN will also be a major, U.S. based integration platform for a host of technologies relevant for the Long-Baseline Neutrino Facility (LBNF) and other future large detectors. This white paper describes the WATCHMAN conceptual design,and presents the results of detailed simulations of sensitivity for the project's nonproliferation and physics goals. Furthermore, it describes the advanced technologies to be used in WATCHMAN, including high quantum efficiency photomultipliers, Water-Based Liquid Scintillator (WbLS), picosecond light sensors such as the Large Area Picosecond Photo Detector (LAPPD), and advanced pattern recognition and particle identification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OBSERVATION OF DIFFUSE COSMIC AND ATMOSPHERIC GAMMA RAYS AT BALLOON ALTITUDES WITH AN ELECTRON-TRACKING COMPTON CAMERA

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronautical Science/Japan Aerospace Exploration Agency on 2006 September 1, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 deg. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm{sup -2} we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be 10 times better than that of other experiments at around 1 MeV.