Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides↗

The solidification of Al–Pd–Mn studied by high-energy X-ray diffraction from electrostatically levitated samples

Here, we report on the results of a high-energy x-ray diffraction study of Al–Pd–Mn to investigate the solidification products obtained during free-cooling using an electrostatic levitation furnace. The primary solidification product from the melt is i-Al–Pd–Mn which coexists with a significant remaining liquid component. As the sample cools further, we find that the solidification pathway is consistent with the liquidus projection and pseudo-binary cut through the ternary phase diagram reported previously. At ambient temperature we have identified the major phase to be the ξ'-phase orthorhombic approximant, along with minor phases identified as Al and, most likely, the R-phase orthorhombic approximant. We have also observed a distinct prepeak in the liquid at high temperature, signifying the presence of extended atomic order. Interestingly, this prepeak was not observed in previous neutron diffraction measurements on the Al–Pd–Mn system. No undercooling was observed preceding the solidification of the i-Al–Pd–Mn phase from the melt which may signal the close similarity of the short-range order in the solid and liquid. However, this can not be clearly determined because of the potential for heterogenous nucleation associated with the presence of an Al2O3 impurity at the surface of the sample.

36 MATERIALS SCIENCE↗

Characterization of proteins by powder diffraction.

A simulation of a protein powder diffraction pattern was stunning in the apparent amount of information that was seen. A subsequent experiment on metmyoglobin gave a powder diffraction pattern that showed very little sample broadening; the peak widths were essentially limited by the instrument resolution. The challenge is to make use of this in protein structure analysis. This talk will recall some of those early experiments and data analyses as well as an overview of current progress and future possibilities.

59 BASIC BIOLOGICAL SCIENCES↗

Letter - X-ray diffraction and Mossbauer spectroscopy of Fe{sup 3+}-bearing Mg-silicate post-perovskite at 128-138 GPa.

The effect of ferric iron on the properties of Mg-silicate post-perovskite (PPv) were studied up to 138 GPa using synchrotron X-ray diffraction and Moessbauer spectroscopy. Our diffraction measurements revealed that the incorporation of Fe{sup 3+} has virtually no effect on the volume of PPv, in contrast to Fe{sup 2+}, which increases the volume. Therefore, incorporation of Fe{sup 3+} increases the density of PPv much more effectively than Fe{sup 2+}. Moessbauer spectroscopy suggests that Fe{sup 3+} enters PPv through charge-coupled substitution and is high spin in the bipolar prismatic site and low spin in the octahedral site (i.e., mixed spin state). Our results may have important implications for the gravitational stability of lower-mantle heterogeneities.

36 MATERIALS SCIENCE↗

In Situ High Energy X-ray Diffraction Characterization of Phase Transformations and Mechanical Behaviors in Rapidly Solidified Titanium and Stainless Steel Alloys [Thesis]

Advanced manufacturing techniques like additive manufacturing (AM) have poised themselves to revolutionize metal manufacturing. A wide range of AM techniques are capable of manufacturing metal components with unique, complex geometries and hastening the scientific-engineering-development cycle. Metal AM relies on a layer-by-layer rapid manufacturing process to build components from the substrate up. Rapid solidification is a large departure from traditional metal manufacturing due to its complex physics. Characterization of rapid solidification is difficult, stemming from the small volumes used in AM and the fast dynamics of the process. High energy X-ray diffraction (HEXRD) is a solution to the characterization problems of rapidly solidified alloys and AM. HEXRD can probe small volumes at fast rates and provides a wide range of thermomechanical and kinetic information. This thesis presents the application of HEXRD to rapidly solidified titanium and stainless steel alloys through a series of case studies. In the first two studies, HEXRD is applied to rapidly solidified titanium and stainless steel welds. The materials are characterized for their temperature history, phase changes, kinetics, and microstructural evolution. In the next case study, HEXRD is applied to characterize phase changes in elastocaloric NiTi shape memory alloys (SMAs) under thermomechanical load. HEXRD, in conjunction with other tools, is used to explain the superior performance of the additively manufactured SMAs. In the final two case studies, HEXRD is used to measure the mechanical response of AM parts with complex geometries; namely, the octet truss lattice. Diffraction reveals a wide range of materials information about the AM microstructure including unexpected phases, texture, and mechanical response to loading. The mechanical results from HEXRD and then compared with theoretical predictions about the performance of octet truss lattices. Summarily, HEXRD is a diverse tool that is poised to address the complex characterization problems of many aspects of the additive manufacturing process.

36 MATERIALS SCIENCE↗

Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement

The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration.

42 ENGINEERING↗

Intact, Commercial Lithium-Polymer Batteries: Spatially Resolved Grating-Based Interferometry Imaging, Bragg Edge Imaging, and Neutron Diffraction

We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.

36 MATERIALS SCIENCE↗

Simultaneous Multi-Bragg Peak Coherent X-ray Diffraction Imaging

The simultaneous measurement of two Bragg reflections by Bragg coherent X-ray diffraction is demonstrated on a twinned Au crystal, which was prepared by the solid-state dewetting of a 30 nm thin gold film on a sapphire substrate. The crystal was oriented on a goniometer so that two lattice planes fulfill the Bragg condition at the same time. The Au 111 and Au 200 Bragg peaks were measured simultaneously by scanning the energy of the incident X-ray beam and recording the diffraction patterns with two two-dimensional detectors. While the former Bragg reflection is not sensitive to the twin boundary, which is oriented parallel to the crystal–substrate interface, the latter reflection is only sensitive to one part of the crystal. The volume ratio between the two parts of the twinned crystal is about 1:9, which is also confirmed by Laue microdiffraction of the same crystal. The parallel measurement of multiple Bragg reflections is essential for future in situ and operando studies, which are so far limited to either a single Bragg reflection or several in series, to facilitate the precise monitoring of both the strain field and defects during the application of external stimuli.

47 OTHER INSTRUMENTATION↗

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

Bending Behavior of a Wrought Magnesium Alloy Investigated by the In Situ Pinhole Neutron Diffraction Method

The tensile twinning and detwinning behaviors of a wrought magnesium alloy have been investigated during in situ four-point bending using the state-of-the-art high spatial resolution pinhole neutron diffraction (PIND) method. The PIND method allowed us to resolve the tensile twinning/detwinning and lattice strain distributions across the bending sample during a loading-unloading sequence with a 0.5 mm step size. It was found that the extensive tensile twinning and detwinning occurred near the compression surface, while no tensile twinning behavior was observed in the middle layer and tension side of the bending sample. During the bending, the neutral plane shifted from the compression side to the tension side. Compared with the traditional neutron diffraction mapping method, the PIND method provides more detailed information inside the bending sample due to a higher spatial resolution.

36 MATERIALS SCIENCE↗

Study on the High-Pressure Behavior of Goethite up to 32 GPa Using X-Ray Diffraction, Raman, and Electrical Impedance Spectroscopy

Goethite is a major iron-bearing sedimentary mineral on Earth. In this study, we conducted in situ high-pressure x-ray diffraction, Raman, and electrical impedance spectroscopy measurements of goethite using a diamond anvil cell (DAC) at room temperature and high pressures up to 32 GPa. We observed feature changes in both the Raman spectra and electrical resistance at about 5 and 11 GPa. However, the x-ray diffraction patterns show no structural phase transition in the entire pressure range of the study. The derived pressure-volume (P-V) data show a smooth compression curve with no clear evidence of any second-order phase transition. Fitting the volumetric data to the second-order Birch–Murnaghan equation of state yields V 0 = 138.9 ± 0.5 Å 3 and K 0 = 126 ± 5 GPa.

58 GEOSCIENCES↗

Using Complementary Methods of Synchrotron Radiation Powder Diffraction and Pair Distribution Function to Refine Crystal Structures with High Quality Parameters—A Review

Determination of the atomic-scale structures of certain fine-grained minerals using single-crystal X-ray diffraction (XRD) has been challenging because they commonly occur as submicron and nanocrystals in the geological environment. Synchrotron powder diffraction and scattering techniques are useful complementary methods for studying this type of minerals. In this review, we discussed three example studies investigated by combined methods of synchrotron radiation XRD and pair distribution function (PDF) techniques: (1) low-temperature cristobalite; (2) kaolinite; and (3) vernadite. Powder XRD is useful to determine the average structure including unit-cell parameters, fractional atomic coordinates, occupancies and isotropic atomic displacement parameters. X-ray/Neutron PDF methods are sensitive to study the local structure with anisotropic atomic displacement parameters (ADP). The results and case studies suggest that the crystal structure and high-quality ADP values can be obtained using the combined methods. The method can be useful to characterize crystals and minerals that are not suitable for single-crystal XRD.

58 GEOSCIENCES↗

Exploring the High-Pressure Phases of Carbon through X-ray Diffraction of Dynamic Compression Experiments on Sandia’s Z Pulsed Power Facility

The carbon phase diagram is rich with polymorphs which possess very different physical and optical properties ideal for different scientific and engineering applications. An understanding of the dynamically driven phase transitions in carbon is particularly important for applications in inertial confinement fusion, as well as planetary and meteorite impact histories. Experiments on the Z Pulsed Power Facility at Sandia National Laboratories generate dynamically compressed high-pressure states of matter with exceptional uniformity, duration, and size that are ideal for investigations of fundamental material properties. X-ray diffraction (XRD) is an important material physics measurement because it enables direct observation of the strain and compression of the crystal lattice, and it enables the detection and identification of phase transitions. Several unique challenges of dynamic compression experiments on Z prevent using XRD systems typically utilized at other dynamic compression facilities, so novel XRD diagnostics have been designed and implemented. We performed experiments on Z to shock compress carbon (pyrolytic graphite) samples to pressures of 150–320 GPa. The Z-Beamlet Laser generated Mn-Heα (6.2 keV) X-rays to probe the shock-compressed carbon sample, and the new XRD diagnostics measured changes in the diffraction pattern as the carbon transformed into its high-pressure phases. Quantitative analysis of the dynamic XRD patterns in combination with continuum velocimetry information constrained the stability fields and melting of high-pressure carbon polymorphs.

36 MATERIALS SCIENCE↗

Stress Relaxation Related to Spontaneous Thin Film Buckling: Correlation between Finite Element Calculations and Micro Diffraction Analysis

Compressive residual stresses generated during thin film deposition may lead to undesirable film damage, such as delamination, buckling, and flaking, ultimately leading to the failure of the device employing the film. Understanding the residual stress generation and role in these damage mechanisms is necessary to preserve thin film integrity and optimize its functional properties. Thin shell theory has been used for decades to predict buckling but the results have not yet been correlated with experimental data since the techniques used to measure stress in metallic films were not able to do so at the required micron scale until recently. Micro scanning X-ray diffraction now enables the direct mapping of the local stress of metallic films. In this paper, finite element method based on thin shell theory and synchrotron X-ray micro diffraction have been used to determine stress maps of thin film buckling patterns. Calculations of the stress distribution in the metallic films have been performed taking into account the buckling geometry determined from optical measurements. Stress distributions over gold blisters and tungsten wrinkles obtained with the two techniques are in fair agreement and allow for the accurate determination of the stress relaxation profile from the bottom to the top of the buckling, validating the thin shell theory model.

36 MATERIALS SCIENCE↗

Beyond the Streetlight Effect: A United Future for Relaxation and Diffraction Methods for Residual Stress Measurement

Residual stress measurement techniques can be categorized as either relaxation or diffraction methods. Practitioners often advocate a particular category and sometimes a specific technique (hole drilling, contour, XRD, neutron, etc) based on their experience or capability rather than using the best technique for the particular application. This paper considers some of the implications from applying this “drunkard’s search” or “streetlight” approach by examining examples where the critical stress could be hidden from both relaxation and diffraction measurements. A better approach to planning residual stress measurements would begin with a detailed consideration of why the stresses should be measured and how the results will be used. Only then can the most appropriate measurement plan be developed. Since a single measurement technique cannot reveal the full state of stress, especially in challenging parts, the use of multiple measurement types often provides the most useful information to customers.

36 MATERIALS SCIENCE↗

Effect of thermomechanical processing on the microstructure and retained austenite stability during in situ tensile testing using synchrotron x-ray diffraction of NbMoAI TRIP steel.

In this work we compare and contrast the stability of retained austenite during tensile testing of Nb-Mo-Al transformation-induced plasticity steel subjected to different thermomechanical processing schedules. The obtained microstructures were characterised using optical metallography, transmission electron microscopy and X-ray diffraction. The transformation of retained austenite to martensite under tensile loading was observed by in-situ high energy X-ray diffraction at 1ID / APS. It has been shown that the variations in the microstructure of the steel, such as volume fractions of present phases, their morphology and dimensions, play a critical role in the strain-induced transition of retained austenite to martensite.

36 MATERIALS SCIENCE↗

Crystallization and preliminary X-ray diffraction analysis of restriction endonuclease EcoRII

Crystals of the restriction endonuclease EcoRII have been obtained by the vapor-diffusion technique in the presence of ammonium sulfate or polyethylene glycol. The best crystals were grown with ammonium sulfate as a precipitant. Crystals with dimensions of up to 0.6 x 0. 6 x 0.6 mm have been observed. The crystals diffract to about 4.0 A resolution at a cryo-temperature of 100 K using a rotating-anode X-ray source and a Rigaku R-AXIS IV imaging-plate detector. The space group has been determined to be either I23 or I2(1)3, with unit-cell parameters a = b = c = 160.3 A, alpha = beta = gamma = 90 degrees. The crystal asymmetric unit contains two protein molecules, and self-rotation function analysis shows a pseudo-twofold symmetry relating the two monomers. Attempts to improve the resolution of crystal diffraction and to search for heavy-atom derivatives are under way.

Deoxyribonucleases, Type II Site-Specific/chemistr↗

Refine your search to explore more results.