Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Extracting Non-propagating Oscillatory Fields in Concrete to Detect Distributed Cracking

We introduce work to find and locate distributed subsurface cracks in concrete by extracting non-propagating oscillatory fields. The medium of interest is concrete, but the approach also applies to other types of inhomogeneous media. The theoretical basis of the work is first presented through a one-dimensional point-scatterer model that considers the wavefield set up by multiple distinct scatterers. More complex scattering scenarios are then investigated using numerical simulation. The numerical models consider two types of scatterers: elliptic large-scale particles distributed throughout a medium and small-sized cracks localized within a damage zone. The theoretical and numerical analyses show that forward propagating waves undergo distinct scattering behavior within the crack damaged zone: non-propagating resonance-like oscillatory fields are set up within the cracked zone that are distinct from the scatter caused by the large-scale particles. We employ frequency-wavenumber (f-k) domain analysis to extract the energy of non-propagating oscillatory fields and thus to detect and locate zones of distributed cracking. The proposed approach is evaluated using numerical simulation and experimental data collected from concrete specimens that contain simulated distributed cracks. The results reflect the location of distributed crack zones in discrete random media such as concrete can be successfully detected.

36 MATERIALS SCIENCE↗

A precise measurement of the Z -boson double-differential transverse momentum and rapidity distributions in the full phase space of the decay leptons with the ATLAS experiment at $\sqrt{s}=8$ TeV

This paper presents for the first time a precise measurement of the production properties of the Z boson in the full phase space of the decay leptons. This is in contrast to the many previous precise unfolded measurements per formed in the fiducial phase space of the decay leptons. The measurement is obtained from proton–proton collision data collected by the ATLAS experiment in 2012 at $\sqrt{s}$ = 8 TeV at the LHC and corresponding to an integrated luminosity of 20.2 fb -1 . The results, based on a total of 15.3 million Z boson decays to electron and muon pairs, extend and improve a previous measurement of the full set of angular coefficients describing Z-boson decay. The double-differential cross section distributions in Z-boson transverse momentum pT and rapidity y are measured in the pole region, defined as 80 < m ℓℓ < 100 GeV, over the range |y| < 3.6. The total uncertainty of the normalised cross-section measurements in the peak region of the pT distribution is dominated by statistical uncertainties over the full range and increases as a function of rapidity from 0.5–1.0% for |y| < 2.0 to 2 - 7% at higher rapidities. The results for the rapidity-dependent transverse momentum distributions are compared to state of-the-art QCD predictions, which combine in the best cases approximate N 4 LL resummation with N 3 LO fixed-order per turbative calculations. The differential rapidity distributions integrated over pT are even more precise, with accuracies from 0.2–0.3% for |y| < 2.0 to 0.4–0.9% at higher rapidities, and are compared to fixed-order QCD predictions using the most recent parton distribution functions. The agreement between data and predictions is quite good in most cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Derivation of a Multiparameter Gamma Model for Analyzing the Residence-Time Distribution Function for Nonideal Flow Systems as an Alternative to the Advection-Dispersion Equation

A new residence-time distribution (RTD) function has been developed and applied to quantitative dye studies as an alternative to the traditional advection-dispersion equation (AdDE). The new method is based on a jointly combined four-parameter gamma probability density function (PDF). The gamma residence-time distribution (RTD) function and its first and second moments are derived from the individual two-parameter gamma distributions of randomly distributed variables, tracer travel distance, and linear velocity, which are based on their relationship with time. The gamma RTD function was used on a steady-state, nonideal system modeled as a plug-flow reactor (PFR) in the laboratory to validate the effectiveness of the model. The normalized forms of the gamma RTD and the advection-dispersion equation RTD were compared with the normalized tracer RTD. The normalized gamma RTD had a lower mean-absolute deviation (MAD) (0.16) than the normalized form of the advection-dispersion equation (0.26) when compared to the normalized tracer RTD. The gamma RTD function is tied back to the actual physical site due to its randomly distributed variables. The results validate using the gamma RTD as a suitable alternative to the advection-dispersion equation for quantitative tracer studies of non-ideal flow systems.

Embry, Irucka↗

DERMS-RT (Distributed Energy Resource Management Solution using Real-Time Optimization) [SWR-20-46]

DERMS-RT provides a distributed energy resource management solution using real-time optimization to control different types of distributed energy resources (DERs) — such as rooftop PVs, battery energy storage systems, HVAC loads, electric water heater loads, and EV charging loads, and use these DERs to provide distribution voltage regulation and peak demand management services. The control approach implemented by DERM-RT is developed based on the real-time optimal power flow and distributed control previously developed by NREL researchers. The software codes are designed to provide modular DER management solution that can be easily applied to control heterogeneous DERs in distribution grids in coordination with centralized utility management systems. Also, DERMS-RT provides application programming interface (API) to extract useful grid model information from an open-source power system simulation software, use the information to solve the optimization problem, and apply the optimal set-points to the controlled DERs. In this way, DERMS-RT provides a plug-and-play function for implementing the real-time DER control on different utility system models, and it can be used as a simulation testbed to demonstrate the impact of real-time DER optimization on improving grid operations.

Ding, Fei↗

Development of Distributed Microgrid Controllers Using HELICS [SWR-21-94]

Development of Distributed Microgrid Controllers Using HELICS uses HELICS framework develop distributed microgrid controllers (DMCs) for coordinated grid service. Development of Distributed Microgrid Controllers Using HELICS includes thirteen agents, including OpenDSS agent, data manager agent, and eleven DMC agents. Development of Distributed Microgrid Controllers Using HELICS can be used as a standard framework to develop fully distributed control solutions that dispatches simulated DERs in simulation platform.

Wang, Jing↗

DERHCAT (Distributed Energy Resource Hosting Capacity Analysis Tool) [SWR-16-32]

NREL's advanced hosting capacity analysis and System Analysis Reports can help utilities, policymakers, and solar developers better understand the impact of adding new distributed photovoltaic (DPV) systems to the electrical distribution system. Advanced hosting capacity analysis considers the thresholds at which new DPV systems will trigger upgrades or changes to the electrical distribution system and evaluates the cost of different options for expanding the hosting capacity. It is one part of NREL's work to help stakeholders better understand the distribution system costs associated with integrating new DPV systems at different penetration levels. NREL's analysis uses a bottom-up methodology that involves simulating distribution systems. The analysis considers sequential increases in hosting capacity and corresponding upgrade costs from a baseline scenario with no DPV up to penetration levels greater than 100% of peak load.

Ding, Fei↗

SIDSIM (Sub-Interval Distribution-function in Simulation) [SWR-17-22]

Time-series simulation is a technique used to estimate the energy delivery of a power generation system with output that changes under changing conditions. Such variable resources include photovoltaic energy systems that experience different levels of sunlight or wind farms with changing wind patterns. As distributed generation from these variable resources continues to flourish, having improved software tools to accurately measure, model, and estimate phenomena of interest to grid integration, in addition to energy output, will be crucial for safeguarding smooth integration and operation of these energy systems. Currently, time-series simulations assume conditions and power output are constant over the duration of a time-step (steady-state assumption). NREL researchers improve the accuracy with a new simulation software called SIDSIM (Sub-Interval Distribution Simulation) that replaces this steady value (solar or wind resource) with a distribution function that has a maximum value, a minimum value, and a shape to the curve within each time-step. The distribution function used for modeling varying values in the SIDSIM software is a novel equation and presents advantageous new benefits over the conventional methods. The first advantage comes in the ability to determine maximum instantaneous power within a time-step. This enables better protection of a system from overcurrent issues and it also allows for better forecasting and reservation of transmission capacity; such capabilities are essential for energy system integration. Second, a distribution function helps to determine the amount of energy loss due to “clipping” in cases where the photovoltaic direct current (DC) system capacity exceeds the inverter capacity, the AC interconnect capacity, or any other limiting component or threshold value. It improves estimates of battery throughput by allowing both charge and discharge of a battery within the duration of a time-step. Third, it provides a more refined estimate of utility-bill impacts by considering the delivered power may be higher than the site load or lower than the regular average power estimates that are made using a quasi-steady-state assumption. SEE ALSO OSTI ID 1,361,018

Walker, Andy↗

Statistical Theory on the Functional Form of Cloud Particle Size Distributions

Abstract Several functional forms of cloud particle size distributions (PSDs) have been used in numerical modeling and remote sensing retrieval studies of clouds and precipitation, including exponential, gamma, lognormal, and Weibull distributions. However, there is no satisfying theoretical explanation as to why certain distribution forms preferentially occur instead of others. Intuitively, the analytical form of a PSD can be derived by directly solving the general dynamic equation, but no analytical solutions have been found yet. Instead of a process-level approach, the use of the principle of maximum entropy (MaxEnt) for determining the theoretical form of PSDs from the perspective of system is examined here. MaxEnt theory states that the probability density function with the largest information entropy among a group satisfying the given properties of the variable should be chosen. Here, the issue of variability under coordinate transformations that arises using the Gibbs–Shannon definition of entropy is identified, and the use of the concept of relative entropy to avoid these problems is discussed. Focusing on cloud physics, the four-parameter generalized gamma distribution is proposed as the analytical form of a PSD using the principle of maximum (relative) entropy with assumptions on power-law relations among state variables, scale invariance, and a further constraint on the expectation of one state variable (e.g., bulk water mass). The four-parameter generalized gamma distribution is very flexible to accommodate various type of constraints that could be assumed for cloud PSDs.

54 ENVIRONMENTAL SCIENCES↗

Estimating Changes in Temperature Distributions in a Large Ensemble of Climate Simulations Using Quantile Regression

Understanding future changes in extreme temperature events in a transient climate is inherently challenging. A single model simulation is generally insufficient to characterize the statistical properties of the evolving climate, but ensembles of repeated simulations with different initial conditions greatly expand the amount of data available. In this paper, we present a new approach for using ensembles to characterize changes in temperature distributions based on quantile regression that more flexibly characterizes seasonal changes. Specifically, our approach uses a continuous representation of seasonality rather than breaking the dataset into seasonal blocks; that is, we assume that temperature distributions evolve smoothly both day to day over an annual cycle and year to year over longer secular trends. To demonstrate our method’s utility, we analyze an ensemble of 50 simulations of the Community Earth System Model (CESM) under a scenario of increasing radiative forcing to 2100, focusing on North America. As previous studies have found, we see that daily temperature bulk variability generally decreases in wintertime in the continental mid- and high latitudes (>40°). A more subtle result that our approach uncovers is that differences in two low quantiles of wintertime temperatures do not shrink as much as the rest of the temperature distribution, producing a more negative skew in the overall distribution. Although the examples above concern temperature only, the technique is sufficiently general that it can be used to generate precise estimates of distributional changes in a broad range of climate variables by exploiting the power of ensembles.

54 ENVIRONMENTAL SCIENCES↗

Communication-Constrained Expansion Planning for Resilient Distribution Systems

Distributed generation and remotely controlled switches have emerged as important technologies to improve the resiliency of distribution grids against extreme weather-related disturbances. Therefore it becomes important to study how best to place them on the grid in order to meet a resiliency criteria, while minimizing costs and capturing their dependencies on the associated communication systems that sustain their distributed operations. This paper introduces the Optimal Resilient Design Problem for Distribution and Communication Systems (ORDPDC) to address this need. The ORDPDC is formulated as a two-stage stochastic mixed-integer program that captures the physical laws of distribution systems, the communication connectivity of the smart grid components, and a set of scenarios that specifies which components are affected by potential disasters. The paper proposes an exact branch-and-price algorithm for the ORDPDC that features a strong lower bound and a variety of acceleration schemes to address degeneracy. The ORDPDC model and branch-and-price algorithm were evaluated on a variety of test cases with varying disaster intensities and network topologies. The results demonstrate the significant impact of the network topologies on the expansion plans and costs, as well as the computational benefits of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

Assessing Air Velocity Distribution in Three Sizes of Commercial Broiler Houses During Tunnel Ventilation

Abstract. Convective cooling is a critical management strategy for maintaining an environment that promotes production efficiency, thermal comfort, and animal well-being in commercial broiler houses. Variations in house size, design, and equipment configuration contribute greatly to the air velocity distribution within the facility. This study assessed total airflow, air velocity distribution, and quantified the floor area in three facilities experiencing insufficient air velocity for maintenance of production efficiency, thermal comfort, and animal well-being. Test facility 1 was an 18.3 × 170.7 m solid side-wall broiler house, test facility 2 was a 15.24 × 144.8 m solid side-wall broiler house, and test facility 3 was a 12.19 × 121.9 m curtain side-wall broiler house. Total airflow of each facility, measured with a Fan Assessment and Numeration System, was 512,730, 389,495, and 329,270 m 3 h -1 for test facilities 1, 2, and 3, respectively. Air velocity distribution patterns were characterized in each house with a Scalable Environment Assessment System (SEAS) and spatial statistics. The air velocity distributions within the test facilities were variable, with notable maxima immediately downstream of the tunnel inlets, which serve as a well-defined vena contracta, and local minima near the leading end of the evaporative pads and the exhaust fans. Equipment within the facilities had an impact on the air velocity distribution by creating reduced cross-sectional areas that resulted in localized increases in air velocity. The percentage of total bird-level floor area in each facility experiencing air velocities below 1.5 m s -1 was 14.3%, 20.7%, and 10.0% for test facilities 1, 2, and 3, respectively. The effective design velocity (V ed ) was calculated from total airflow using the measured building cross-sectional area. The V ed measured 2.97, 2.45, and 2.34 m s -1 for test facilities 1, 2, and 3, respectively. Mean cross-sectional air velocity (V cs ) was calculated from SEAS data and normalized using each facility’s V ed to account for differences in building size for comparison. Test facility 1, the largest of the three houses, generated substantially higher V cs /V ed than test facilities 2 and 3. Test facilities 2 and 3 maintained a larger proportion of V cs above V ed than test facility 1. Test facility 1 showed 26.5% of the total house length below V ed , while test facilities 2 and 3 had only 20.8% and 17.5%, respectively, of the total house length below V ed . The lower-velocity regions were due to the length of the evaporative cooling pad inlet and the use of tunnel doors, and the exhaust fan placement on the side-walls in test facility 1 created an additional pronounced low-velocity area. Placement of tunnel ventilation fans on the end-wall of the facility, rather than the side-wall, eliminated the low-velocity region at the exhaust end of the facility. Modifications to current practices for broiler production facility construction and evaporative cooling pad inlet installation would be required to minimize the low-velocity region at the inlet end of these facilities. Consideration of house width and physical arrangement of the air inlets, tunnel fans, and internal equipment are critical for improving the uniformity of air velocity in commercial broiler houses. Keywords: Air velocity, Anemometer, Broiler house, FANS, Tunnel ventilation.

Agriculture↗

Genome Sizes and the Benford Distribution

Background: Data on the number of Open Reading Frames (ORFs) coded by genomes from the 3 domains of Life show the presence of some notable general features. These include essential differences between the Prokaryotes and Eukaryotes, with the number of ORFs growing linearly with total genome size for the former, but only logarithmically for the latter. Results: Simply by assuming that the (protein) coding and non-coding fractions of the genome must have different dynamics and that the non-coding fraction must be particularly versatile and therefore be controlled by a variety of (unspecified) probability distribution functions (pdf’s), we are able to predict that the number of ORFs for Eukaryotes follows a Benford distribution and must therefore have a specific logarithmic form. Using the data for the 1000+ genomes available to us in early 2010, we find that the Benford distribution provides excellent fits to the data over several orders of magnitude. Conclusions: In its linear regime the Benford distribution produces excellent fits to the Prokaryote data, while the full nonlinear form of the distribution similarly provides an excellent fit to the Eukaryote data. Furthermore, in their region of overlap the salient features are statistically congruent. This allows us to interpret the difference between Prokaryotes and Eukaryotes as the manifestation of the increased demand in the biological functions required for the larger Eukaryotes, to estimate some minimal genome sizes, and to predict a maximal Prokaryote genome size on the order of 8–12 megabase pairs. These results naturally allow a mathematical interpretation in terms of maximal entropy and, therefore, most efficient information transmission.

54 ENVIRONMENTAL SCIENCES↗

Abundance and Distribution of Precociously Mature Male Spring Chinook Salmon of Hatchery and Natural Origin in the Yakima River

Abstract Precocious maturation of artificially propagated male Chinook salmon Oncorhynchus tshawytscha has the potential to alter abundance and distribution of males in freshwater and thereby influence ecological and genetic interactions with other fish in the natural environment. Between 1999 and 2007, the Cle Elum Supplementation and Research Facility has produced and released into the upper Yakima River basin of Washington an annual average of 124,573 males that mature precociously. We investigated the abundance and distribution of precociously mature male spring Chinook salmon of hatchery and natural (wild) origin during the spawning season (4–7 months after hatchery release) in the Yakima River. We counted the number of precocious males on the spawning grounds while snorkeling during the peak of spawning and electrofished to determine abundance and distribution of precocious males away from redds. We also collected Chinook salmon to determine percent precocity and size and age distributions. The number of precocious hatchery males on redds was less than 0.05% of the total number of fish released, and they were significantly less abundant on redds than precocious wild males. Between 1999 and 2007, the mean annual abundance of precocious age-1 hatchery males observed on the spawning grounds was 22 fish (range, 0–78). Precocious hatchery and wild males were both found throughout the spawning range during the spawning season, but significant differences in distribution between origins were detected. Precocious hatchery males were proportionately more abundant in the most downstream sampling reach and less abundant in a tributary with no hatchery facilities. In addition, most precocious hatchery males were found downstream of spawning areas during the spawning season. It appears that many precocious hatchery males migrate downstream from release and fail to migrate back to the spawning grounds, or they die within the Yakima River before spawning. Thus, precocious male Chinook salmon resulting from hatchery production in the Yakima River do not contribute favorably to harvest and may pose ecological risks to other taxa, but most of these fish have a low probability of contributing genes to future generations.

Pearsons, Todd N.↗

Computational Fluid Dynamics Modeling of The Dalles Project: Effects of Spill Flow Distribution Between the Washington Shore and the Tailrace Spillwall

The U.S. Army Corps of Engineers-Portland District (CENWP) has ongoing work to improve the survival of juvenile salmonids (smolt) migrating past The Dalles Dam. As part of that effort, a spillwall was constructed to improve juvenile egress through the tailrace downstream of the stilling basin. The spillwall was designed to improve smolt survival by decreasing smolt retention time in the spillway tailrace and the exposure to predators on the spillway shelf. The spillwall guides spillway flows, and hence smolt, more quickly into the thalweg. In this study, an existing computational fluid dynamics (CFD) model was modified and used to characterize tailrace hydraulics between the new spillwall and the Washington shore for six different total river flows. The effect of spillway flow distribution was simulated for three spill patterns at the lowest total river flow. The commercial CFD solver, STAR-CD version 4.1, was used to solve the unsteady Reynolds-averaged Navier-Stokes equations together with the k-epsilon turbulence model. Free surface motion was simulated using the volume-of-fluid (VOF) technique. The model results were used in two ways. First, results graphics were provided to CENWP and regional fisheries agency representatives for use and comparison to the same flow conditions at a reduced-scale physical model. The CFD results were very similar in flow pattern to that produced by the reduced-scale physical model but these graphics provided a quantitative view of velocity distribution. During the physical model work, an additional spill pattern was tested. Subsequently, that spill pattern was also simulated in the numerical model. The CFD streamlines showed that the hydraulic conditions were likely to be beneficial to fish egress at the higher total river flows (120 kcfs and greater, uniform flow distribution). At the lowest flow case, 90 kcfs, it was necessary to use a non-uniform distribution. Of the three distributions tested, splitting the flow evenly between Bay 7 and Bay 8 had hydraulics deemed most beneficial for egress by CENWP fisheries biologists and regional fishery agency representatives. The numerical and physical model results were very similar, building confidence in both hydraulic tools.

13 HYDRO ENERGY↗

Distributed Wind Policy Comparison Tool Guidebook

Power through Policy: 'Best Practices' for Cost-Effective Distributed Wind is a U.S. Department of Energy (DOE)-funded project to identify distributed wind technology policy best practices and to help policymakers, utilities, advocates, and consumers examine their effectiveness using a pro forma model. Incorporating a customized feed from the Database of State Incentives for Renewables andEfficiency (DSIRE), the Web-based Distributed Wind Policy Comparison Tool (Policy Tool) is designed to assist state, local, and utility officials in understanding the financial impacts of different policy options to help reduce the cost of distributed wind technologies. The Policy Tool can be used to evaluate the ways that a variety of federal and state policies and incentives impact theeconomics of distributed wind (and subsequently its expected market growth). It also allows policymakers to determine the impact of policy options, addressing market challenges identified in the U.S. DOE's '20% Wind Energy by 2030' report and helping to meet COE targets.

17 WIND ENERGY↗

Utilizing Electric Vehicles to Assist Integration of Large Penetrations of Distributed Photovoltaic Generation Capacity

This analysis provides detailed distribution-level insights into the leveraging potential of distributed rooftop photovoltaic (PV) technologies and electric vehicle (EV) charging. Either of the two technologies by themselves – at some high penetrations – may cause some voltage control challenges or overloading problems, respectively. But when combined, there could be synergistic effects, at least intuitively, whereby one technology mitigates the negative impacts of the other. High penetration of EV charging may overload existing distribution system components, most prominently the secondary transformer. If PV technology is installed at residential premises or anywhere downstream of the secondary transformer, it will provide another electricity source, thus relieving the loading on the transformers. Another synergetic or mitigating effect could be envisioned when high PV penetration reverses the power flow upward in the distribution system (from the homes upstream into the distribution system). Protection schemes may then no longer function as designed and voltage violations (exceeding the voltage upper limit of the American National Standards Institute (ANSI) voltage range) may occur. In this particular situation, EV charging could consume the generated energy from the PV, such that the reversal of power flow can be reduced or alleviated. Given these potential mutual synergistic behaviors of PV and EV technologies, this project attempted to quantify the benefits of combining the two technologies.

Tuffner, Francis K.↗

Time series power flow analysis for distribution connected PV generation

Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating potential PV impacts.

Broderick, Robert Joseph↗

Theoretical foundation for measuring the groundwater age distribution.

In this study, we use PFLOTRAN, a highly scalable, parallel, flow and reactive transport code to simulate the concentrations of 3H, 3He, CFC-11, CFC-12, CFC-113, SF6, 39Ar, 81Kr, 4He and themean groundwater age in heterogeneous fields on grids with an excess of 10 million nodes. We utilize this computational platform to simulate the concentration of multiple tracers in high-resolution, heterogeneous 2-D and 3-D domains, and calculate tracer-derived ages. Tracer-derived ages show systematic biases toward younger ages when the groundwater age distribution contains water older than the maximum tracer age. The deviation of the tracer-derived age distribution from the true groundwater age distribution increases with increasing heterogeneity of the system. However, the effect of heterogeneity is diminished as the mean travel time gets closer the tracer age limit. Age distributions in 3-D domains differ significantly from 2-D domains. 3D simulations show decreased mean age, and less variance in age distribution for identical heterogeneity statistics. High-performance computing allows for investigation of tracer and groundwater age systematics in high-resolution domains, providing a platform for understanding and utilizing environmental tracer and groundwater age information in heterogeneous 3-D systems. Groundwater environmental tracers can provide important constraints for the calibration of groundwater flow models. Direct simulation of environmental tracer concentrations in models has the additional advantage of avoiding assumptions associated with using calculated groundwater age values. This study quantifies model uncertainty reduction resulting from the addition of environmental tracer concentration data. The analysis uses a synthetic heterogeneous aquifer and the calibration of a flow and transport model using the pilot point method. Results indicate a significant reduction in the uncertainty in permeability with the addition of environmental tracer data, relative to the use of hydraulic measurements alone. Anthropogenic tracers and their decay products, such as CFC11, 3H, and 3He, provide significant constraint oninput permeability values in the model. Tracer data for 39Ar provide even more complete information on the heterogeneity of permeability and variability in the flow system than the anthropogenic tracers, leading to greater parameter uncertainty reduction.

Gardner, William Payton↗

Refine your search to explore more results.