Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze the images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).

60 APPLIED LIFE SCIENCES↗

Chromatin and higher-order chromosome organization shape the recombination landscape in C. elegans

Meiotic recombination generates crossovers, which physically link homologous chromosomes, and direct their segregation to opposite poles. Despite the benefits, crossovers are restricted both in number as well as spatially. Crossovers in the nematode C. elegans occur most frequently within the distal regions (or “arms”) of the chromosomes, which comprise ~50% of the genome, but ~90% of the genetic map length. Meiotic recombination initiates with the formation of programmed double strand breaks (DSBs) catalyzed by the SPO-11 enzyme. It has been unclear whether the crossover bias in C. elegans is a consequence of DSB distribution, or instead reflects a mechanism that biases the downstream repair outcome of DSBs. In order to address this, we generated a genome-wide map of meiotic DSBs by mapping the distribution of the sole C. elegans RecA-like recombinase, RAD-51, by ChIP-seq. We have found that the RAD-51 binding pattern is strikingly similar to the known recombination pattern in C. elegans. The majority of RAD-51 binding sites occur on chromosome arms. Comparing RAD-51 distribution relative to functional genomic elements revealed that RAD-51 is particularly enriched in intronic DNA while coding sequences are underrepresented in RAD-51 occupied regions. We find that monomethylation of histone H3 lysine 36 (H3K36me1), which has not previously been associated with meiotic recombination, is highly correlated with break site preference. H3K36me1 is particularly enriched over active genes with high intron content, suggesting that the specific chromatin environment associated with these genes favors DSB formation in C. elegans. We have also identified a sequence motif that is highly overrepresented in DSB sites. Although the DSB pattern is highly correlated with crossover frequency, there are interesting exceptions. In particular, the sub-telomeric regions are completely devoid of crossovers but are active DSB sites. We have also identified a DNA sequence motif that appears to be enriched within DSB sites suggesting that sequence specific factors may have a role in DSB specification in C. elegans.

59 BASIC BIOLOGICAL SCIENCES↗

Am-241 Nuclear Safety and Environmental Interactions

NASA’s supply of radioisotopes for Radioisotope Heat Units (RHU) and Radioisotope Thermoelectric Generator (RTG) power sources is facing a crisis due to shortages of Pu-238 for future missions. Am-241 is a possible replacement for Pu-238 since its stockpile from the nuclear weapons program has remained relatively intact. The purpose of this project was to assess the safety of Am-241 and the risks associated with it as compared with PU-238. The project has resulted in a journal article, F. De-La-Torre-Aguilar, N. White, M. Prelas, R. V. Tompson, and S. K. Loyalka "Space nuclear power system accidents: Doses from Pu-238 and Am- 241 inhalation," Progress in Nuclear Energy vol.100C (2017), pp.171-182, which showed that the radiation dosage resulting from Am-241 inhalation are about 1/2.5 of the dosage resulting from Pu-238 inhalation per KW of Pu-238 power. Considerable progress was also made on the Direct Simulation Monte Carlo Method (DSMC) for simulation of aerosol evolution during accidents resulting in three publications: 1.I. Saldivar, F. De-La-Torre-Aguilar, M. Boraas, and S. K. Loyalka “Benchmark problems in aerosol evolution: Comparison of some exact and DSMC results” in Annals of Nuclear Energy vol.117 (2018), pp.213-222. 2. I. Saldivar and S. K. Loyalka, “Evolution of Aerosols Coupled to Environments: Verification of Direct Simulation Monte Carlo (DSMC)”, Nuclear Technology 204 (2018), pp.172-183. 3. M. Boraas and S. K. Loyalka, “Mesh Free Simulation of Spatially Inhomogeneous aerosols in Arbitrary Geometries” Nuclear Science and Engineering (2018). Further, we have computations on Am-241/Pu-238 vapor and aerosol interactions, and found that the vapor condensation rate is relatively insensitive to the mass effects, confirming some previous results. We have also completed computations of charge effects on evolution of different species aerosols and a manuscript is in preparation. Additionally, we have compared atmospheric dispersion and deposition of Pu-238 and Am-241 using the HYSPLIT code. We have also used a real lung model and the CFD program FLUENT to compute PuO2 and AmO2 deposition to explore improvements upon the ICPR-66 model. We have found that the deposition efficiencies of PuO2 and AmO2 are similar. These results (four manuscripts) will be submitted for publication in the post project period. We have made progress using framework of Mars 2020 mission nuclear risk assessment model to integrate all results, but our progress has been limited as the improved consequence modeling itself has been quite involved and challenging. We will integrate and complete the more extensive risk modeling computations and publish the results in the post-project period. In addition to the above, the project has resulted in research training of four PhD students

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Applications of data mining technology to enhance O and M: automatic planning of electrical isolation with deep learning - 255

Data mining technology is now readily available, thanks to high powered, low cost computing resource and useful coding tools. We study several applications of data mining to enhance operation and maintenance (O and M), such as abnormality prediction, efficiency diagnosis, document traceability, image recognition, etc. In field support, we try automatic planning of electrical isolation with deep learning. Currently, a skilled engineer plans electrical isolation procedure with hundreds of the circuit diagrams and the related documents, taking man-hours. If this task becomes automatic, it is very efficient. The automatic planning has two issues. One is much calculation time of electrical circuit simulator, searching billions of electrical conducting paths. The other is interpretation of human fuzzy information, such as ease of work. Deep learning is helpful to resolve them. We performed a model case study of the electrical isolation. We applied a deep neural network (DNN) for dropping in the calculation time. We trained the circuit diagrams and the responses of the circuit simulator to the DNN, constructing an efficient path search algorithm in the DNN. The calculation time of the DNN was shorter by a factor of 32 for the model case, compared with that of the electrical circuit simulator. We applied a deep Q-network (DQN) for the interpretation of fuzzy information. The DQN optimized isolation procedure from the viewpoint of the work load with the equipment layout, related doses, and values of wet bulb globe temperature (WBGT) to prevent heatstroke. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compressive Classification for TEM-EELS

Acquiring atomic-resolution images of beam sensitive materials or under dynamic conditions (e.g. operando STEM) is very difficult and requires precise dose fractioning to minimize the dose delivered to the sample and acquire the data more rapidly than dynamics present. Typical methods of low-dose STEM imaging include adjusting the beam current, dwell-time, and probe Scanning transmission electron microscopy (STEM) is used routinely to obtain atomic-resolution images of a small selection of radiation tolerant materials under stable conditions.size. All three of these determine the dose over a spatial area in STEM. Recently, compressive sensing [1] has been applied to electron microscopy. The computational imaging method of inpainting [2] has been proposed as a method to reduce dose and increase acquisition speed for STEM. Inpainting is a technique to recover missing pixels in an image. By skipping pixels (randomly) during acquisition, a fourth dose-control mechanism is realized [3]. A few implementations of randomly-subsampled STEM exist (e.g., [4]). To make the concepts of compressive sensing accessible to the microscopy community we begin with an example using atomic resolution images of a GaAs crystal (see Figure 1). Because the crystal is periodic it has a sparse representation in reciprocal space. In fact, a sparse representation is a key component of compressive sensing. If an image is sub-sampled randomly we find that the Fourier transform remains sparse, but becomes increasing noisy as less and less data is acquired. Yet, by finding the peaks in the reciprocal image and removing the noise it is possible to recover atomic resolution images with only 1% of the pixels. Figure 1 shows the reconstruction process for GaAs sub-sampled at 50%, 10%, 5%, and 1%. Periodic images form a special class for which the optimal sampling approach (according to CS theory) is a random selection of pixels. For non-periodic images, such as those arising in in-situ STEM, methods such as dictionary learning are necessary [2,5]. The data can be compressed in time for TEM [5] or pixels can be skipped randomly for STEM. There are several issues that arise in developing a random scan for STEM [4] and a coded aperture for TEM. The remainder of the talk will address these issues. References: [1] E Candes and M Wakin. Signal Processing Magazine, IEEE. 2(25) (2008), pp. 21. [2] A Stevens, Pu Y, Sun Y, et al. Artificial Intelligence & Statistics (AISTATS), 2017. [3] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [4] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016). [5] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [6] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Hao, Weituo↗

Monte Carlo-based simulation of dynamic jaws tomotherapy

Purpose: Original TomoTherapy systems may involve a trade-off between conformity and treatment speed, the user being limited to three slice widths (1.0, 2.5, and 5.0 cm). This could be overcome by allowing the jaws to define arbitrary fields, including very small slice widths (<1 cm), which are challenging for a beam model. The aim of this work was to incorporate the dynamic jaws feature into a Monte Carlo (MC) model called TomoPen, based on the MC code PENELOPE, previously validated for the original TomoTherapy system. Methods: To keep the general structure of TomoPen and its efficiency, the simulation strategy introduces several techniques: (1) weight modifiers to account for any jaw settings using only the 5 cm phase-space file; (2) a simplified MC based model called FastStatic to compute the modifiers faster than pure MC; (3) actual simulation of dynamic jaws. Weight modifiers computed with both FastStatic and pure MC were compared. Dynamic jaws simulations were compared with the convolution/superposition (C/S) of TomoTherapy in the ''cheese'' phantom for a plan with two targets longitudinally separated by a gap of 3 cm. Optimization was performed in two modes: asymmetric jaws-constant couch speed (''running start stop,'' RSS) and symmetric jaws-variable couch speed (''symmetric running start stop,'' SRSS). Measurements with EDR2 films were also performed for RSS for the formal validation of TomoPen with dynamic jaws. Results: Weight modifiers computed with FastStatic were equivalent to pure MC within statistical uncertainties (0.5% for three standard deviations). Excellent agreement was achieved between TomoPen and C/S for both asymmetric jaw opening/constant couch speed and symmetric jaw opening/variable couch speed, with deviations well within 2%/2 mm. For RSS procedure, agreement between C/S and measurements was within 2%/2 mm for 95% of the points and 3%/3 mm for 98% of the points, where dose is greater than 30% of the prescription dose (gamma analysis). Dose profiles acquired in transverse and longitudinal directions through the center of the phantom were also compared with excellent agreement (2%/2 mm) between all modalities. Conclusions: The combination of weights modifiers and interpolation allowed implementing efficiently dynamic jaws and dynamic couch features into TomoPen at a minimal cost in terms of efficiency (simulation around 8 h on a single CPU).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification and Validation of the Stakeholder Tool for Assessing Radioactive Transportation (START) – 22323

The U.S. Department of Energy (DOE) Office of Integrated Waste Management is planning for the eventual transportation, storage, and disposal of spent nuclear fuel (SNF) and high-level radioactive waste (HLW) from nuclear power plant and DOE sites. The Stakeholder Tool for Assessing Radioactive Transportation (START) is a web-based, geospatial decision-support tool developed for evaluating routing options and other aspects of transporting SNF and HLW, covering rail, truck, barge, and intermodal infrastructure and operations in the continental United States. The verification and validation (V&V) process is intended to independently assess START to provide confidence in the ability of START to accurately provide intended results. The V&V process checks the START tool using a variety of methods, ranging from independent hand calculations to comparison of START performance and results to those of other codes. The V&V activity was conducted independently from the START development team with opportunities to provide feedback and collaborate throughout the process. The V&V analyzed attributes of transportation routes produced by START, including route distance and both population and population density captured within buffer zones around routes. Population in the buffer zone, population density in the buffer zone, and route distance were all identified as crucial outputs of the START code and were subject to V&V tasks. Some of the improvements identified through the V&V process were standardizing the underlying population data in START, changing the projection of the population raster data, and changes to the methodology used for population density to improve its applicability for expected users. This collaboration also led to suggested improvements to some of the underlying shape file segments within START. A formal series of test routes went through the V&V process from START version 3.2.1 following the implementation of the recommended improvements to START. The V&V of the buffer zone population and distance reported in START were achieved by utilizing a custom workflow developed in QGIS. This platform was chosen because it is fully independent of START. The buffer zone population and route distances in START showed excellent agreement to independent V&V test results. Over 200 route test cases were run; in all cases, the percent difference in the population within the buffer zone was less than +/- 5%, and the majority of cases were below +/- 1%. These cases were also duplicated in ArcMap, which is Environmental Systems Research Institute’s (ESRI) GIS desktop application. The ArcMap results also show good agreement; however, they cannot be considered independent of START because START also uses ESRI software. The V&V tasks are currently addressing population density and estimated radiation dose in START as well as implementing further automation of the V&V process to allow larger suites of test routes to be run more easily and quickly by less experienced GIS users. These improvements to the V&V process will make it a valuable tool for the development team and the stakeholders so that each new iteration of START can easily be checked for quality and consistency. This paper and presentation will describe the V&V process, findings and implications, and ongoing V&V activities.

START, DOE, Transporation, dose, GIS↗

Comparison of Irradiated TRISO Fuel Radioactivity from Multiple Advanced Reactor Designs

The SCALE code system was used to model, deplete, and compare several different TRISO-fueled reactor designs: a helium-cooled prismatic reactor, a helium-cooled pebble-bed reactor (PBR), and a Fluoride-Lithium-Beryllium (FLIBE) molten-salt-cooled PBR. The purpose of this comparison was to understand how differences in the reactor designs affect the radioactivity of the fuel after discharge and whether those differences are significant. First, the various reactor designs were build and depleted in the TRITON module for each design and fuel enrichment. Then, the TRITON outputs were used to create burn-up dependent reactor libraries. These libraries were then used by ORIGEN to determine the activities of discharged fuel for each reactor, which were compared to generic Westinghouse 17x17 fuel. Overall, the results showed that short term decays are dominated by reactors with higher operating powers, and the reactor type, initial fuel enrichment, and maximum burn-up are of only secondary importance. Although this analysis only focuses on activities in becquerels, these dependencies are consistent with the expected behavior of decay heat. However, analysis of long- term time periods post-irradiation shows that the reactor type and maximum burn-up have strong impacts on the activities; initial fuel enrichment has a secondary impact while operating power is inconsequential. These results would be useful for analyses, such as dose assessment and modeling in post- release scenarios; normal fuel handling operations; and spent fuel transport, storage and disposal. Of particular interest, the results in this report show that analyses that focus on spent nuclear fuel of advanced reactors need to consider each parameter carefully. Unsurprisingly, if the correct operating power is not used in short term analyses, the results will not be correct. Perhaps unexpectedly, however, if the correct reactor type is not used, then the long term results will also be incorrect, especially for areas such as permanent disposal. Even though this report focuses on the total activity of nuclear fuel, it provides initial results on the effects of various input parameters and also provides a framework to extend the work into other analyses of spent fuel from advanced reactors, especially those employing TRISO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SILENE Benchmark Critical Experiments for Criticality Accident Alarm Systems

In October 2010 a series of benchmark experiments was conducted at the Commissariat a Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE [1] facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems (CAASs). This presentation will discuss the geometric configuration of these experiments and the quantities that were measured and will present some preliminary comparisons between the measured data and calculations. This series consisted of three single-pulsed experiments with the SILENE reactor. During the first experiment the reactor was bare (unshielded), but during the second and third experiments it was shielded by lead and polyethylene, respectively. During each experiment several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor, and some of these detectors were themselves shielded from the reactor by high-density magnetite and barite concrete, standard concrete, and/or BoroBond. All the concrete was provided by CEA Saclay, and the BoroBond was provided by Y-12 National Security Complex. Figure 1 is a picture of the SILENE reactor cell configured for pulse 1. Also included in these experiments were measurements of the neutron and photon spectra with two BICRON BC-501A liquid scintillators. These two detectors were provided and operated by CEA Valduc. They were set up just outside the SILENE reactor cell with additional lead shielding to prevent the detectors from being saturated. The final detectors involved in the experiments were two different types of CAAS detectors. The Babcock International Group provided three CIDAS CAAS detectors, which measured photon dose and dose rate with a Geiger-Mueller tube. CIDAS detectors are currently in use at Y-12 in the newly constructed Highly Enriched Uranium Materials Facility. The second CAAS detector used a 6 LiF TLD to absorb neutrons and a silicon detector to count the charge particles released by these absorption events. Lawrence Livermore National Laboratory provided four of these detectors, which had formerly been used at the Rocky Flats facility in the United States.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

USING A RISK-BASED METHODOLOGY FOR THE TRANSFER OF RADIOACTIVE MATERIAL WITHIN THE SAVANNAH RIVER SITE BOUNDARY

Shipment of radioactive materials (RAM) is discussed in the Code of Federal Regulations in parts of both 49 CFR and 10 CFR. The regulations provide the requirements and rules necessary for the safe shipment of RAM across public highways, railways, waterways, and through the air. These shipments are sometimes referred to as in-commerce shipments. Shipments of RAM entirely within the boundaries of Department of Energy sites, such as the Savannah River Site (SRS), can be made using methodology allowing provisions to maintain equivalent safety while deviating from the regulations for in-commerce shipments. These onsite shipments are known as transfers at the SRS. These transfers must follow the requirements approved in a site-specific Transportation Safety Document (TSD). The TSD defines how the site will transfer materials so that they have equivalence to the regulations. These equivalences are documented in an Onsite Safety Assessment (OSA). The OSA can show how a particular packaging used onsite is equivalent to that which would be used for an in-commerce shipment. This is known as a deterministic approach. However, when a deterministic approach is not viable, the TSD allows for a risk-based OSA to be written. These risk-based assessments show that if a packaging does not provide the necessary safety to ensure that materials are not released (during normal or accident conditions) then the worst-case release of materials does not result in a dose consequence worse than that defined for the SRS. This paper will discuss recent challenges and successes using this methodology at the SRS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-796: Variation of Surface Photon Energy Spectra On Bone Heterogeneity and Beam Obliquity Between Flattened and Unflattened Beam

Purpose: This study investigates the spectra of surface photon energy and energy fluence in the bone heterogeneity and beam obliquity using flattened and unflattened photon beams. The spectra were calculated in a bone and water phantom using Monte Carlo simulation (the EGSnrc code). Methods: Spectra of energy, energy fluence and mean energy of the 6 MV flattened and unflattened photon beams (field size = 10 × 10 cm{sup 2}) produced by a Varian TrueBEAM linear accelerator were calculated at the surfaces of a bone and water phantom using Monte Carlo simulations. The spectral calculations were repeated with the beam angles turned from 0° to 15°, 30° and 45° in the phantoms. Results: It is found that the unflattened photon beams contained more photons in the low-energy range of 0 – 2 MeV than the flattened beams with a flattening filter. Compared to the water phantom, both the flattened and unflattened beams had slightly less photons in the energy range < 0.4 MeV when a bone layer of 1 cm is present under the phantom surface. This shows that the presence of the bone decreased the low-energy photons backscattered to the phantom surface. When the photon beams were rotated from 0° to 45°, the number of photon and mean photon energy increased with the beam angle. This is because both the flattened and unflattened beams became more hardened when the beam angle increased. With the bone heterogeneity, the mean energies of both photon beams increased correspondingly. This is due to the absorption of low-energy photons by the bone, resulting in more significant beam hardening. Conclusion: The photon spectral information is important in studies on the patient’s surface dose enhancement when using unflattened photon beams in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

SU-F-BRD-13: Quantum Annealing Applied to IMRT Beamlet Intensity Optimization

Purpose: We report on the first application of quantum annealing (QA) to the process of beamlet intensity optimization for IMRT. QA is a new technology, which employs novel hardware and software techniques to address various discrete optimization problems in many fields. Methods: We apply the D-Wave Inc. proprietary hardware, which natively exploits quantum mechanical effects for improved optimization. The new QA algorithm, running on this hardware, is most similar to simulated annealing, but relies on natural processes to directly minimize the free energy of a system. A simple quantum system is slowly evolved into a classical system, representing the objective function. To apply QA to IMRT-type optimization, two prostate cases were considered. A reduced number of beamlets were employed, due to the current QA hardware limitation of ∼500 binary variables. The beamlet dose matrices were computed using CERR, and an objective function was defined based on typical clinical constraints, including dose-volume objectives. The objective function was discretized, and the QA method was compared to two standard optimization Methods: simulated annealing and Tabu search, run on a conventional computing cluster. Results: Based on several runs, the average final objective function value achieved by the QA was 16.9 for the first patient, compared with 10.0 for Tabu and 6.7 for the SA. For the second patient, the values were 70.7 for the QA, 120.0 for Tabu, and 22.9 for the SA. The QA algorithm required 27–38% of the time required by the other two methods. Conclusion: In terms of objective function value, the QA performance was similar to Tabu but less effective than the SA. However, its speed was 3–4 times faster than the other two methods. This initial experiment suggests that QA-based heuristics may offer significant speedup over conventional clinical optimization methods, as quantum annealing hardware scales to larger sizes.

07 ISOTOPE AND RADIATION SOURCES↗

Ion-beam-induced damage formation in CdTe

Damage formation in <111>- and <112>-oriented CdTe single crystals irradiated at room temperature and 15 K with 270 keV Ar or 730 keV Sb ions was investigated in situ using Rutherford backscattering spectroscopy (RBS) in channeling configuration. Defect profiles were calculated from the RBS spectra using the computer code DICADA and additional energy-dependent RBS measurements were performed to identify the type of defects. At both temperatures no formation of a buried amorphous layer was detected even after prolonged irradiation with several 10{sup 16} ions/cm{sup 2}. The fact that CdTe is not rendered amorphous even at 15 K suggests that the high resistance to amorphization is caused by the high ionicity of CdTe rather than thermal effects. The calculated defect profiles show the formation of a broad defect distribution that extends much deeper into the crystal than the projected range of the implanted ions at both temperatures. The post-range defects in CdTe thus do not seem to be of thermal origin either, but are instead believed to result from migration driven by the electronic energy loss.

36 MATERIALS SCIENCE↗

SU-E-T-586: Field Size Dependence of Output Factor for Uniform Scanning Proton Beams: A Comparison of TPS Calculation, Measurement and Monte Carlo Simulation

Purpose: Output dependence on field size for uniform scanning beams, and the accuracy of treatment planning system (TPS) calculation are not well studied. The purpose of this work is to investigate the dependence of output on field size for uniform scanning beams and compare it among TPS calculation, measurements and Monte Carlo simulations. Methods: Field size dependence was studied using various field sizes between 2.5 cm diameter to 10 cm diameter. The field size factor was studied for a number of proton range and modulation combinations based on output at the center of spread out Bragg peak normalized to a 10 cm diameter field. Three methods were used and compared in this study: 1) TPS calculation, 2) ionization chamber measurement, and 3) Monte Carlos simulation. The XiO TPS (Electa, St. Louis) was used to calculate the output factor using a pencil beam algorithm; a pinpoint ionization chamber was used for measurements; and the Fluka code was used for Monte Carlo simulations. Results: The field size factor varied with proton beam parameters, such as range, modulation, and calibration depth, and could decrease over 10% from a 10 cm to 3 cm diameter field for a large range proton beam. The XiO TPS predicted the field size factor relatively well at large field size, but could differ from measurements by 5% or more for small field and large range beams. Monte Carlo simulations predicted the field size factor within 1.5% of measurements. Conclusion: Output factor can vary largely with field size, and needs to be accounted for accurate proton beam delivery. This is especially important for small field beams such as in stereotactic proton therapy, where the field size dependence is large and TPS calculation is inaccurate. Measurements or Monte Carlo simulations are recommended for output determination for such cases.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-593: Outcomes and Toxicities From a Clinical Trial of APBI Using MERT+IMRT with the Same XMLC

Purpose: We present the results from a clinical trial of accelerated partial breast irradiation (APBI), using mixed modulated photon and electron beams (MERT+IMRT) with the same photon multileaf collimator (xMLC). Methods: Seven patients were enrolled in the first year of the APBI clinical trial. Patients were selected following the conditions included in the NSABP B-39/RTOG 0413 protocol. The targets and clinically relevant normal structures were contoured on the CT images following this protocol for APBI-EBRT. All treatments were delivered using combined modulated electron and photon beams by means of the same xMLC installed in a SIEMENS Primus linac, with a reduced SSD equal to 60 cm for electron beams. The plans were performed with a treatment planning system based on full Monte Carlo simulations, called CARMEN, developed by our group. Simultaneously, an alternative IMRT plan was calculated with the commercial TPS PINNACLE v8.0m (Philips), and both plans were compared. An ad-hoc breast phantom with semi-spherical geometry called NAOMI was designed for a specific QA protocol. Patients received a total dose of 38.5 Gy, delivered in 10 fractions over 5 consecutive days, with a twice-a-day hypofractionated schema.Follow-up visits during 2.5 years on average were repeated at 1 month post-treatment, every 3 months for the first year, and every 6 months for the second year. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). Results: This APBI technique achieved high loco-regional control rates and showed low acute toxicity (grade 1 of CTCAE) and no toxicities from first month onwards. Photographic assessment of cosmesis showed skin excellent results. Conclusion: The clinical results achieved with MERT+IMRT by using the same xMLC are comparable or even better than those obtained with other APBI techniques, thanks to a software solution without any additional equipment or specific device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-556: A Potential Real Time AQA for Cyberknife Cones and MLC Based Treatments

Purpose: To investigate the potential use of the Raven™ (LAP of America Laser Applications) for real time AQA of Cyberknife™ with InCise2 MLC (Accuray™ Medical). Methods: At setup, the Raven was rotated 45° on which an Accuray™ AQA cube was positioned. Three different AQA plans for fixed cone, InCise2MLC, and a modified MLC plan were delivered repeatedly ten times. The additional shapes in modified AQA plan enable additional reproducibility checks for all the MLC pairs. During the test, the cube was aligned by imbedded fiducials and irradiated. The two angled radiation beams aimed center tungsten ball of the cube and projected 45° to phosphor screen and registered by a CCD camera of the Raven device. The centricity of the metal ball in the irradiated field was then analyzed using Matlab codes. Results: For AP images, the average offsets of X, Y, and radial directions are 0.24 ± 0.04 mm, 0.25 ± 0.02 mm and 0.35 ±± 0.03 mm respectively for the cone; 0.34 ± 0.02 mm, 0.49 ± 0.04 mm and 0.60 ± 0.04 mm respectively for the MLC. For lateral images, they are 0.63 ± 0.05 mm, 0.11 ± 0.02 mm and 0.64 ± 0.04 mm respectively for the cone, 0.79 ± 0.08 mm, −0.23 ± 0.06 mm and 0.82 ± 0.09 mm respectively for the MLC. No inconsistent MLC shapes were found in the modified AQA group. Conclusion: The results are consistent with clinically acceptable values (≤1mm from baseline). The results suggest the potential of replacement of the standard AQA test with the novel real-time Raven device for Cyberknife daily QA. The modified MLC based AQA provides a more comprehensive MLC daily QA capability. Further improvements in its resolution and automatic analyzing capability are warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-407: Evaluation of Four Commercial Dosimetry Systems for Routine Patient-Specific Tomotherapy Delivery Quality Assurance

Purpose: The purpose of this project was to evaluate the performance of four commercially available dosimetry systems for Tomotherapy delivery quality assurance (DQA). Methods: Eight clinical patient plans were chosen to represent a range of treatment sites and typical clinical plans. Four DQA plans for each patient plan were created using the TomoTherapy DQA Station (Hi-Art version 4.2.1) on CT images of the ScandiDose Delta4, IBA MatriXX Evolution, PTW Octavius 4D and Sun Nuclear ArcCHECK phantoms. Each detector was calibrated following the manufacture-provided procedure. No angular response correction was applied. All DQA plans for each detector were delivered on the Tomotherapy Hi-Art unit in a single measurement session but on different days. The measured results were loaded into the vendor supplied software for each QA system for comparison with the TPS-calculated dose. The Gamma index was calculated using 3%/3mm, 2%/2mm with 10% dose threshold of maximum TPS calculated dose. Results: Four detector systems showed comparable gamma pass rates for 3%/3m, which is recommended by AAPM TG119 and commonly used within the radiotherapy community. The averaged pass rates ± standard deviation for all DQA plans were (98.35±1.97)% for ArcCHECK, (99.9%±0.87)% for Matrix, (98.5%±5.09)% for Octavius 4D, (98.7%±1.27)% for Delata4. The rank of the gamma pass rate for individual plans was consistent between detectors. Using 2%/2mm Gamma criteria for analysis, the Gamma pass rate decreased on average by 9%, 8%, 6.6% and 5% respectively. Profile and Gamma failure map analysis using the software tools from each dosimetry system indicated that decreased passing rate is mainly due to the threading effect of Tomo plan. Conclusion: Despite the variation in detector type and resolution, phantom geometry and software implementation, the four systems demonstrated similar dosimetric performance, with the rank of the gamma pass rate consistent for the plans considered.

60 APPLIED LIFE SCIENCES↗

Refine your search to explore more results.