Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

General field evaluation in high-order meshes on GPUs

Robust and scalable function evaluation at any arbitrary point in the finite/spectral element mesh is required for querying the partial differential equation solution at points of interest, comparison of solution between different meshes, and Lagrangian particle tracking. This is a challenging problem, particularly for high-order unstructured meshes partitioned in parallel with MPI, as it requires identifying the element that overlaps a given point and computing the corresponding reference space coordinates. Here, we present a robust and efficient technique for general field evaluation in large-scale high-order meshes with quadrilaterals and hexahedra. In the proposed method, a combination of globally partitioned and processor-local maps are used to first determine a list of candidate MPI ranks, and then locally candidate elements that could contain a given point. Next, element-wise bounding boxes further reduce the list of candidate elements. Finally, Newton’s method with trust region is used to determine the overlapping element and corresponding reference space coordinates. Since GPU-based architectures have become popular for accelerating computational analyses using meshes with tensor-product elements, specialized kernels have been developed to utilize the proposed methodology on GPUs. The method is also extended to enable general field evaluation on surface meshes. The paper concludes by demonstrating the use of the proposed method in various applications ranging from mesh-to-mesh transfer during r-adaptivity to Lagrangian particle tracking.

97 MATHEMATICS AND COMPUTING↗

Adaptation of EVIAVE methodology for monitoring and follow-up when evaluating the environmental impact of landfills

Treatment and final disposal of Municipal Solid Waste can have a significant role in the generation of negative environmental impacts. As a prevention strategy, such activities are subjected to the process of Environmental Impact Assessment (EIA). Still, the follow-up of Environmental Management Plans or mitigation measures is limited, for one due to a lack of methodological approaches. In searching for possibilities, the University of Granada (Spain) developed a diagnostic methodology named EVIAVE, which allows one to quantify, by means of indexes, the environmental impact of landfills in view of their location and the conditions of exploitation. EVIAVE is applicable within the legal framework of the European Union and can be adapted to the environmental and legal conditions of other countries. This study entails its adaptation in Colombia, for the follow-up and control of the EIA process for landfills. Modifications involved inclusion of the environmental elements flora and fauna, and the evaluation of the environmental descriptors in agreement with the concept of vulnerability. The application of the modified EVIAVE in Colombian landfills allowed us to identify the elements affected by the operating conditions and maintenance. It may be concluded that this methodology is viable and effective for the follow-up and environmental control of EIA processes for landfills, and to analyze the associated risks, as it takes into account related environmental threats and vulnerabilities. - Highlights: • A modified methodology is used to monitor and follow-up environmental impacts in landfills. • The improved methodology includes the Vulnerability of Flora and Fauna to evaluate environmental impact of landfills. • The methodology serves to identify and evaluate the sources of risk generated in the construction and siting of landfills. • Environmental vulnerability indicators improve effectiveness of the control and follow-up phases of landfill management. • The follow-up of environmental management plans may help diminish the implementation gap in Environmental Impact Assessment.

54 ENVIRONMENTAL SCIENCES↗

Greece's reformed EIA system: Evaluating its implementation and potential

Highlights: • Greek nationwide multidimensional EIA System effectiveness evaluation study • Innovation of reform: a central Electronic Environmental Registry (e-ER) • e-ER manages and publish results of the EIA, EMS and Inspection processes. • There is a chasm between new legal provisions and implementation in practice. • Results indicate persistent poor-quality EIA, bureaucracy, lack of transparency. - Abstract: The Memorandum of Understanding (MoU) signed by the Greek government and the troika in 2010 contained numerous austerity policies and requirements for administrative reforms, among which is that of the national Environmental Impact Assessment (EIA) system. Complying with this requirement, Law4014/2011 was passed, aiming at reducing bureaucracy and increasing the country's appeal to investors whilst ensuring environmental protection. The present paper provides the first systematic, multi-scale and multidimensional evaluation of the effectiveness of the new EIA system. The evaluation is based firstly on the results of a Pan-Hellenic survey, involving key EIA consultants and authorities; secondly, on additional, in-depth interviews with EIA specialists, National- Ministry and Regional EIA Authorities; and thirdly, on the content review of 105 Environmental Impact statements. The results highlight the persistence of serious problems despite the reform of the Hellenic EIA System. The data reveal a significant discrepancy between what is set out in law and the actual practice. Although Law 4014/2011 contains progressive and innovative elements (such as adopting a life cycle approach to the EIA process, and mandating the development and use of a central Electronic Environmental Registry (e-ER) to manage and publish results of the EIA process), the recorded failure to implement them in practice results in a non-transparent and ineffective EIA system. Recommendations for improvement are proposed as well as areas for further research.

54 ENVIRONMENTAL SCIENCES↗

Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests

The hot box test method has been applied to evaluate both the steady-state (U-value) and dynamic thermal properties of building envelopes. However, the high construction cost of full-scale hot box apparatus and the testing time required (usually several days) may prevent its wider adoption. To overcome the limitations of full-scale hot box tests, here we propose a novel method to evaluate the dynamic thermal performance of building envelope components using a small-scale calibrated hot box and scaled-down specimen. In this paper, the scaling relationships of thermal properties evaluated using a full-size specimen and a scaled-down specimen are established based on the Laplace transform of the heat transfer equations. In addition, dynamic thermal properties obtained from scaled-down experimental tests are compared to the values calculated by the EN ISO13768 (ISO) method. A small-scale hot box with a 355 mm × 355 mm metering area was constructed and calibrated to validate the correlations. Three scaled-down concrete sandwich wall panels were then tested and the scaling relationship was cross-validated using the experimental results, finite difference (FD) simulations, and the ISO method. The results indicate that the dynamic thermal properties obtained from a scaled-down hot box test can be correlated to its full-size counterpart when certain conditions are met. The scaled-down hot box test is demonstrated to be an effective yet economical alternative to a full-scale test with significantly reduced experimentation cost and turn-around time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Evaluating performance of different generative adversarial networks for large-scale building power demand prediction

We report as an unsupervised-learning data-driven model, Generative Adversarial Networks (GANs) have recently attracted a lot of attention for various applications. There is potential to apply GANs for large-scale building power demand prediction, which is needed for power grid operation. However, there are many GAN variations and it is unclear which GAN is suitable for this application. To answer this question, this paper identifies five promising GANs (Original GAN, cGAN, SGAN, InfoGAN, and ACGAN) and evaluates their performance for predicting building power demand at a large scale. Physics-based building energy models are developed to generate training and reference data. A new evaluation indicator that combines accuracy and reproducibility is proposed to evaluate the performance of different GANs in predicting building power demand. The results show that SGAN and InfoGAN are not suitable because they cannot control the number of generated building samples for different building types. The prediction performance among the Original GAN, cGAN, and ACGAN can vary depending on training sample sizes and number of building types. If the training sample size is sufficiently large, Original GAN and cGAN can predict building power demand more accurately than ACGAN with the same number of samples. If training samples are limited, Original GAN provides better accuracy than cGAN and ACGAN. When the number of building types increase, the prediction accuracy increases for cGAN, decreases for ACGAN, and remains the same for Original GAN. As a result, cGAN and Original GAN are recommended for large-scale building power demand prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of leakage neutron spectra for zirconium with D-T neutrons and validation of evaluated nuclear data

Integral neutronics experiments have been a powerful tool and method for examining the reliability of evaluated nuclear data. In the present paper, the accuracy of evaluated nuclear data for Zirconium has been validated by comparing measured leakage neutron spectra with calculated ones. Leakage neutron spectra from the irradiation of D-T neutrons on Zirconium samples were experimentally measured at 60° and 120° by using a time-of-flight method. Theoretical calculations are carried out by Monte Carlo neutron transport code MCNP-4C with evaluated nuclear data of the ENDF/B-VII.0, ENDF/B-VIII.0, JENDL-4.0 and CENDL-3.1 libraries. From the comparisons, it is found that the calculations with JENDL-4.0 gives better agreements with the experiments at 60° while a large discrepancies are observed in the 4–13.5 MeV energy range at 120°. However, the calculated spectra using the data from ENDF/B-VII.0, ENDF/B-VIII.0 and CENDL-3.1 libraries showed some discrepancies with the measured ones, especially caused by the difference of the elastic and inelastic angular distributions and the secondary neutron energy distributions in the continuum inelastic scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating offshore legacy wells for geologic carbon storage: A case study from the Galveston and Brazos areas in the Gulf of Mexico

In this article, federal offshore waters in the Gulf of Mexico are of interest for large-scale geologic carbon storage (GCS). However, more than 80,000 offshore oil and gas wells exist in the region, which could impact the integrity of sealing intervals. In this study, we propose a screening methodology for ranking offshore legacy wells based on the challenge they may present to GCS. The methodology relies on the review of well regulatory records to 1) identify leakage pathways and assess the potential hazards that wells pose to planned GCS operations, 2) evaluate well features that impact the accessibility of wells to determine the feasibility of potential corrective actions, and 3) rank wells based on the overall challenge they may pose for GCS. We demonstrate our framework by evaluating the construction and abandonment of 156 wells across eight areas of interest (AOIs) in shallow federal waters along the Texas Gulf Coast. The majority (99.3 %) of wells considered were constructed and plugged in a manner that did not isolate prospective GCS targets in the Upper and Lower Miocene formations and may potentially require a challenging or uncertain corrective action prior to GCS. Dataset trends suggest that the observed well construction and plugging designs may be common in shallow offshore federal waters along the Texas Gulf Coast. Consequently, operators pursuing offshore GCS projects in the region may consider selecting areas that avoid challenging wells or performing robust evaluations of legacy well leakage risks to plan corrective action prior to CO 2 injection.

58 GEOSCIENCES↗

Multi-mode evaluation of power-maximizing cross-flow turbine controllers

A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performance at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.

13 HYDRO ENERGY↗

Incorporate Imaging Characteristics Into an Arteriovenous Malformation Radiosurgery Plan Evaluation Model

Purpose: To integrate imaging performance characteristics, specifically sensitivity and specificity, of magnetic resonance angiography (MRA) and digital subtraction angiography (DSA) into arteriovenous malformation (AVM) radiosurgery planning and evaluation. Methods and Materials: Images of 10 patients with AVMs located in critical brain areas were analyzed in this retrospective planning study. The image findings were first used to estimate the sensitivity and specificity of MRA and DSA. Instead of accepting the imaging observation as a binary (yes or no) mapping of AVM location, our alternative is to translate the image into an AVM probability distribution map by incorporating imagers' sensitivity and specificity, and to use this map as a basis for planning and evaluation. Three sets of radiosurgery plans, targeting the MRA and DSA positive overlap, MRA positive, and DSA positive were optimized for best conformality. The AVM obliteration rate (ORAVM) and brain complication rate served as endpoints for plan comparison. Results: In our 10-patient study, the specificities and sensitivities of MRA and DSA were estimated to be (0.95, 0.74) and (0.71, 0.95), respectively. The positive overlap of MRA and DSA accounted for 67.8% {+-} 4.9% of the estimated true AVM volume. Compared with plans targeting MRA and DSA-positive overlap, plans targeting MRA-positive or DSA-positive improved ORAVM by 4.1% {+-} 1.9% and 15.7% {+-} 8.3%, while also increasing the complication rate by 1.0% {+-} 0.8% and 4.4% {+-} 2.3%, respectively. Conclusions: The impact of imagers' quality should be quantified and incorporated in AVM radiosurgery planning and evaluation to facilitate clinical decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Teaching the Anatomy of Oncology: Evaluating the Impact of a Dedicated Oncoanatomy Course

Purpose: Anatomic considerations are often critical in multidisciplinary cancer care. We developed an anatomy-focused educational program for radiation oncology residents integrating cadaver dissection into the didactic review of diagnostic, surgical, radiologic, and treatment planning, and herein assess its efficacy. Methods and Materials: Monthly, anatomic-site based educational modules were designed and implemented during the 2008-2009 academic year at Duke University Medical Center. Ten radiation oncology residents participated in these modules consisting of a 1-hour didactic introduction followed by a 1-hour session in the gross anatomy lab with cadavers prepared by trained anatomists. Pretests and posttests were given for six modules, and post-module feedback surveys were distributed. Additional review questions testing knowledge from prior sessions were integrated into the later testing to evaluate knowledge retention. Paired analyses of pretests and postests were performed by Wilcoxon signed-rank test. Results: Ninety tests were collected and scored with 35 evaluable pretest and posttest pairs for six site-specific sessions. Posttests had significantly higher scores (median percentage correct 66% vs. 85%, p < 0.001). Of 47 evaluable paired pretest and review questions given 1-3 months after the intervention, correct responses rates were significantly higher for the later (59% vs. 86%, p = 0.008). Resident course satisfaction was high, with a median rating of 9 of 10 (IQR 8-9); with 1 being 'less effective than most educational interventions' and 10 being 'more effective than most educational interventions.' Conclusions: An integrated oncoanatomy course is associated with improved scores on post-intervention tests, sustained knowledge retention, and high resident satisfaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Liver Function After Proton Beam Therapy for Hepatocellular Carcinoma

Purpose: Our previous results for treatment of hepatocellular carcinoma with proton beam therapy (PBT) revealed excellent local control. In this study, we focused on the impact of PBT on normal liver function. Methods and Materials: The subjects were 259 patients treated with PBT at University of Tsukuba between January 2001 and December 2007. We evaluated the Child-Pugh score pretreatment, on the final day of PBT, and 6, 12, and 24 months after treatment with PBT. Patients who had disease progression or who died with tumor progression at each evaluation point were excluded from the analysis to rule out an effect of tumor progression. An increase in the Child-Pugh score of 1 or more was defined as an adverse event. Results: Of the 259 patients, 241 had no disease progression on the final day of PBT, and 91 had no progression within 12 months after PBT. In univariate analysis, the percentage volumes of normal liver receiving at least 0, 10, 20, and 30 GyE in PBT (V0, 10, 20, and 30) were significantly associated with an increase of Child-Pugh score at 12 months after PBT. Of the 91 patients evaluated at 12 months, 66 had no increase of Child-Pugh score, 15 had a 1-point increase, and 10 had an increase of {>=}2 points. For the Youden index, the optimal cut-offs for V0, V10, V20, and V30 were 30%, 20%, 26%, and 18%, respectively. Conclusion: Our findings indicate that liver function after PBT is significantly related to the percentage volume of normal liver that is not irradiated. This suggests that further study of the relationship between liver function and PBT is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Control Trial: Evaluating Aluminum-Based Antiperspirant Use, Axilla Skin Toxicity, and Reported Quality of Life in Women Receiving External Beam Radiotherapy for Treatment of Stage 0, I, and II Breast Cancer

Purpose: Standard skin care instructions regarding the use of antiperspirants during radiotherapy to the breast varies across North America. Women have articulated that when instructed to not use antiperspirant, the potential for body odor is distressing. Historical practices and individual opinions have often guided practice in this field. The present study had 2 purposes. To evaluate whether the use of aluminum-based antiperspirant while receiving external beam radiotherapy for stage 0, I, or II breast cancer will increase axilla skin toxicity and to evaluate whether the use of antiperspirant during external beam radiotherapy improves quality of life. Methods: A total of 198 participants were randomized to either the experimental group (antiperspirant) or control group (standard care-wash only). The skin reactions in both groups were measured weekly and 2 weeks after treatment using the National Cancer Institute Common Toxicity Criteria Adverse Events, version 3, toxicity grading criteria. Both groups completed the Functional Assessment for Chronic Illness Therapy's questionnaire for the breast population quality of life assessment tool, with additional questions evaluating the effect of underarm antiperspirant use on quality of life before treatment, immediately after treatment, and 2 weeks after treatment during the study. Results: The skin reaction data were analyzed using the generalized estimating equation. No statistically significant difference was seen in the skin reaction between the 2 groups over time. The quality of life data also revealed no statistically significant difference between the 2 groups over time. Conclusions: Data analysis indicates that using antiperspirant routinely during external beam radiotherapy for Stage 0, I, or II breast cancer does not affect the intensity of the skin reaction or the self-reported quality of life. This evidence supports that in this particular population, there is no purpose to restrict these women from using antiperspirants during their treatment, and the decision to use an antiperspirant or not in this setting should be left to the discretion of the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp more effective than educational sessions at their own institutions. All of the residents (100%) would recommend this course to others. Conclusions: The ARC boot camp is an effective intervention for improving radiation oncology residents' knowledge and understanding of anatomy and radiology in addition to enhancing their confidence and accuracy in contouring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Robustness to Setup and Range Uncertainties for Head and Neck Patients Treated With Pencil Beam Scanning Proton Therapy

Purpose: To evaluate the robustness of head and neck plans for treatment with intensity modulated proton therapy to range and setup errors, and to establish robustness parameters for the planning of future head and neck treatments. Methods and Materials: Ten patients previously treated were evaluated in terms of robustness to range and setup errors. Error bar dose distributions were generated for each plan, from which several metrics were extracted and used to define a robustness database of acceptable parameters over all analyzed plans. The patients were treated in sequentially delivered series, and plans were evaluated for both the first series and for the combined error over the whole treatment. To demonstrate the application of such a database in the head and neck, for 1 patient, an alternative treatment plan was generated using a simultaneous integrated boost (SIB) approach and plans of differing numbers of fields. Results: The robustness database for the treatment of head and neck patients is presented. In an example case, comparison of single and multiple field plans against the database show clear improvements in robustness by using multiple fields. A comparison of sequentially delivered series and an SIB approach for this patient show both to be of comparable robustness, although the SIB approach shows a slightly greater sensitivity to uncertainties. Conclusions: A robustness database was created for the treatment of head and neck patients with intensity modulated proton therapy based on previous clinical experience. This will allow the identification of future plans that may benefit from alternative planning approaches to improve robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving parameter estimation for column experiments by multi-model evaluation and comparison

Reliability of column experiment data interpretation by fitting the data to a transport model using the nonlinear least squares method is of concern when the complexity of the experiment increases. Misfits often occur and are accepted with the excuse of system complexity. More often, overfits are published and accepted uncritically. The objective of this work was to improve the reliability of column experiment data interpretation to provide insights for future investigation and select estimates for application prediction. We proposed to achieve this goal by evaluating and comparing various estimates that consider the uncertainties in experimental conditions, sensitivities of model parameters, alternative parameterizations and models. Two examples from the literature were selected for the illustration. Sensitivity analysis showed that the experimentally-controlled parameters (water content, flow rate and pulse volume) are much more sensitive than the transport parameters (dispersivity and mass transfer coefficient) in breakthrough curve fitting. Fixing these sensitive parameters may lead to misfit or biased estimate. Estimating sensitive parameters helps diagnose and remediate the misfit. The dispersion coefficient was parameterized as a function of solute molecular diffusion coefficient, medium dispersivity and average pore water velocity to reduce the number of estimated parameters for multiple tracers. Nonlinear least squares statistics were used to evaluate the goodness-of-fit for the multiple estimates obtained using different fitting schemes (e.g., fixing or estimating parameters), parameterizations and models (e.g., equilibrium or nonequilibrium). The F-test and Akaike s Information Criteria were used for the discrimination of statistically reasonable estimates. Our results suggest that sensitivity/uncertainty analysis and model evaluation /discrimination are useful to improve the reliability of column experiment data interpretation.

58 GEOSCIENCES↗

Refine your search to explore more results.