Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Development for fissile assay in recycled fuel using lead slowing down spectrometer

A future nuclear energy system is under development to turn spent fuels produced by PWRs into fuels for a SFR (Sodium Fast Reactor) through the pyrochemical process. The knowledge of the isotopic fissile content of the new fuel is very important for fuel safety. A lead slowing down spectrometer (LSDS) is under development to analyze the fissile material content (Pu{sup 239}, Pu{sup 241} and U{sup 235}) of the fuel. The LSDS requires a neutron source, the neutrons will be slowed down through their passage in a lead medium and will finally enter the fuel and will induce fission reactions that will be analysed and the isotopic content of the fuel will be then determined. The issue is that the spent fuel emits intense gamma rays and neutrons by spontaneous fission. The threshold fission detector screens the prompt fast fission neutrons and as a result the LSDS is not influenced by the high level radiation background. The energy resolution of LSDS is good in the range 0.1 eV to 1 keV. It is also the range in which the fission reaction is the most discriminating for the considered fissile isotopes. An electron accelerator has been chosen to produce neutrons with an adequate target through (e{sup -},γ)(γ,n) reactions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

{sup 99}Mo Production at KIPT Neutron Source Facility

Argonne National Laboratory (ANL) and Kharkov Institute of Physics and Technology (KIPT) have cooperated on the construction of the Neutron Source Facility (NSF) at KIPT, Kharkov (Ukraine). The NSF facility consists of an electron accelerator driven system (ADS) generating 300 kW of thermal power for multiple applications, including medical isotope production. ANL performed extensive analyses including medical isotopes production, reactivity monitoring, operations and control, refueling, cold neutron source design, target design,and radiation shielding. The present study focuses on the use of the KIPT NSF for medical isotope production. Medical isotopes are radioactive isotopes with short half-lives used in diagnostic and therapeutic medical procedures. For example, brain cancer is difficult to treat by ordinary surgery and only brachytherapy with {sup 131}Cs, which has 9.7 days half-life, has shown effective results on the patients. {sup 99m}Tc is the most common medical isotope used in medical diagnoses because the wavelength of its gamma radiation (8.8 pm) is about the same as the conventional X-ray diagnostic devices. {sup 99m}Tc has 6 hours half-life, therefore it cannot be stored because it decays into {sup 99}Tc. The parent of {sup 99m}Tc is {sup 99}Mo, which has 66 hours half-life. Consequently, the delivery of {sup 99m}Tc occurs through shipping {sup 99}Mo samples to the medical facilities. The Neutron Source Facility of KIPT is the first ADS in the world operating at non-zero power and allows producing several isotopes for medical applications. The total power of the facility is about 300 kW, including ∼200 kW from fission reactions. The construction of the NSF has been already completed and operations will start during year 2016. After 20 irradiation days, {sup 82}Br, {sup 64}Cu, {sup 165}Dy, {sup 166}Ho, {sup 192}Ir, {sup 194}Ir, {sup 186}Re, {sup 188}Re and {sup 153}Sm have specific activities, larger than 100 MBq/mg without taking into account the self-shielding effect and therefore they are good candidates for production. The self-shielding effect plays an important role for all nuclide parents that have a large microscopic capture cross section. This effect reduces the reaction rate and therefore the specific activity. For instance, the analyses of molybdenum trioxide (MoO{sub 3}) irradiation samples have shown that the self-shielding effect may reduce the specific activity by a factor 1.4. The metallic form of natural molybdenum produces a higher specific activity, relative to the trioxide form. Analyses on the 6-day Ci {sup 99}Mo activity have shown that is possible to perform between 40 to 310 {sup 99m}Tc medical procedures per MoO{sub 3} irradiation week. The number of medical procedures depends on the diagnosed organ and the weight of the patient. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo Simulation On X-Ray Produced At High Intensity Laser Facilities - Paper 20

With the rapid development of laser technology, a number of high intensity laser devices are emerging in the world. At the same time, the ionizing radiation hazard produced from the interaction between high intensity laser and solid target has gradually been observed. Because Laser-plasma interactions can accelerate electrons to high energies (10's to 1000's of keV). These hot electrons subsequently interact with ions in the target and generate Bremsstrahlung X-rays, which become an ionizing radiation source. Measurements show that significant amounts of radiation can be generated from this ionizing radiation source at high intensity laser facilities. However, very limited studies have been made on the laser-induced ionizing radiation hazard and the protection issues. In this paper, a X-ray dose calculation model was developed and X-ray dose produced in the interaction between high intensity laser and solid target was studied by simulation using Monte Carlo code. (authors)

42 ENGINEERING↗

Pulse Radiolysis Study of Radiation Effect on Molten Salt

The molten salt reactor concept, where nuclear fuel is dissolved in a molten salt that also serves as the heat transfer fluid, is a leading candidate for next generation nuclear reactors. This necessitates a thorough understanding of radiation effects on molten salt media to support the design, development, and deployment of such reactors. Early, pioneering pulse radiolysis molten salt experiments observed key primary radiolysis products such as the solvated electron (esolv?) and dichloride radical anion (Cl2??), but left many fundamental mechanistic and reactivity questions unanswered. Here we report on the reaction kinetics of esolv? and Cl2?? in molten LiCl-KCl eutectic salt doped with Zn2+ ion, using electron pulse radiolysis to observe the transient behavior from nanosecond to microsecond time scales. Experiments were performed at the BNL Laser-Electron Accelerator Facility using a recently-developed high-temperature sample holder. Prompt formation of esolv? and Cl2?? are observed; esolv? decays within hundreds of nanoseconds while Cl2?? decays more slowly by second-order kinetics, more likely by cross-recombination rather than disproportionation. This work was supported as part of the Molten Salts in Extreme Environments Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Radiation Shielding at High-Energy Electron and Proton Accelerators

The goal of accelerator shielding design is to protect the workers, general public, and the environment against unnecessary prompt radiation from accelerator operations. Additionally, shielding at accelerators may also be used to reduce the unwanted background in experimental detectors, to protect equipment against radiation damage, and to protect workers from potential exposure to the induced radioactivity in the machine components. The shielding design for prompt radiation hazards is the main subject of this chapter.

43 PARTICLE ACCELERATORS↗

SPECTROSCOPIC STUDIES OF STRUCTURE, DYNAMICS AND REACTIVITY IN IONIC LIQUIDS.

Ionic liquids (ILs) are a rapidly expanding family of condensed-phase media with important applications in energy production, nuclear fuel and waste processing, improving the efficiency and safety of industrial chemical processes, and pollution prevention. ILs are generally nonvolatile, noncombustible, highly conductive, recyclable and capable of dissolving a wide variety of materials. They are finding new uses in chemical synthesis, catalysis, separations chemistry, electrochemistry and other areas. Ionic liquids have dramatically different properties compared to conventional molecular solvents, and they provide a new and unusual environment to test our theoretical understanding of charge transfer and other reactions. We are interested in how IL properties influence physical and dynamical processes that determine the stability and lifetimes of reactive intermediates and thereby affect the courses of chemical reactions and product distributions. Successful use of ionic liquids in radiation-filled environments, where their safety advantages could be significant, requires an understanding of ionic liquid radiation chemistry. For example, characterizing the primary steps of IL radiolysis will reveal radiolytic degradation pathways and suggest ways to prevent them or mitigate their effects on the properties of the material. An understanding of ionic liquid radiation chemistry will also facilitate pulse radiolysis studies of general chemical reactivity in ILs, which will aid in the development of applications listed above. Very early in our radiolysis studies it became evident that slow solvation dynamics of the excess electron in ILs (which vary over a wide viscosity range) increases the importance of pre-solvated electron reactivity and consequently alters product distributions. Parallel studies of IL solvation phenomena using coumarin-153 dynamic Stokes shifts and polarization anisotropy decay rates are done to compare with electron solvation studies and to evaluate the influence of ILs on charge transport processes. Picosecond pulse radiolysis studies at BNL's Laser-Electron Accelerator Facility (LEAF) [1] are used to identify reactive species in ionic liquids and measure their solvation and reaction rates. IL solvation and rotational dynamics are measured by TCSPC in the laboratory of E. W. Castner at Rutgers Univ. Investigations of radical species in irradiated ILs are carried out at ANL by I. Shkrob and S. Chemerisov using EPR spectroscopy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ionic Liquids: Radiation Chemistry, Solvation Dynamics and Reactivity Patterns

Ionic liquids (ILs) are a rapidly expanding family of condensed-phase media with important applications in energy production, nuclear fuel and waste processing, improving the efficiency and safety of industrial chemical processes, and pollution prevention. ILs are generally nonvolatile, noncombustible, highly conductive, recyclable and capable of dissolving a wide variety of materials. They are finding new uses in chemical synthesis, catalysis, separations chemistry, electrochemistry and other areas. Ionic liquids have dramatically different properties compared to conventional molecular solvents, and they provide a new and unusual environment to test our theoretical understanding of charge transfer and other reactions. We are interested in how IL properties influence physical and dynamical processes that determine the stability and lifetimes of reactive intermediates and thereby affect the courses of chemical reactions and product distributions. Successful use of ionic liquids in radiation-filled environments, where their safety advantages could be significant, requires an understanding of ionic liquid radiation chemistry. For example, characterizing the primary steps of IL radiolysis will reveal radiolytic degradation pathways and suggest ways to prevent them or mitigate their effects on the properties of the material. An understanding of ionic liquid radiation chemistry will also facilitate pulse radiolysis studies of general chemical reactivity in ILs, which will aid in the development of applications listed above. Very early in our radiolysis studies it became evident that slow solvation dynamics of the excess electron in ILs (which vary over a wide viscosity range) increases the importance of pre-solvated electron reactivity and consequently alters product distributions. Parallel studies of IL solvation phenomena using coumarin-153 dynamic Stokes shifts and polarization anisotropy decay rates are done to compare with electron solvation studies and to evaluate the influence of ILs on charge transport processes. Picosecond pulse radiolysis studies at BNL's Laser-Electron Accelerator Facility (LEAF) are used to identify reactive species in ionic liquids and measure their solvation and reaction rates. We and our collaborators (R. Engel (Queens College, CUNY) and S. Lall-Ramnarine, (Queensborough CC, CUNY)) develop and characterize new ionic liquids specifically designed for our radiolysis and solvation dynamics studies. IL solvation and rotational dynamics are measured by TCSPC and fluorescence upconversion measurements in the laboratory of E. W. Castner at Rutgers Univ. Investigations of radical species in irradiated ILs are carried out at ANL by I. Shkrob and S. Chemerisov using EPR spectroscopy. Diffusion rates are obtained by PGSE NMR in S. Greenbaum's lab at Hunter College, CUNY and S. Chung's lab at William Patterson U. Professor Mark Kobrak of CUNY Brooklyn College performs molecular dynamics simulations of solvation processes. A collaboration with M. Dietz at U. Wisc. Milwaukee is centered around the properties and radiolytic behavior of ionic liquids for nuclear separations. Collaborations with C. Reed (UC Riverside), D. Gabel (U. Bremen) and J. Davis (U. South Alabama) are aimed at characterizing the radiolytic and other properties of borated ionic liquids, which could be used to make fissile material separations processes inherently safe from criticality accidents.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress in Antiproton Production at the Fermilab Tevatron Collider

Fermilab Collider Run II has been ongoing since 2001. During this time peak luminosities in the Tevatron have increased from approximately 10 x 10{sup 30} cm{sup -2}sec{sup -1} to 300 x 10{sup 30} cm{sup 02}sec{sup -1}. A major contributing factor in this remarkable performance is a greatly improved antiproton production capability. Since the beginning of Run II, the average antiproton accumulation rate has increased from 2 x 10{sup 10}{anti p}/hr to about 24 x 10{sup 10}{anti p}/hr. Peak antiproton stacking rates presently exceed 28 x 10{sup 10}{anti p}/hr. The antiproton stacking rate has nearly doubled since 2005. It is this recent progress that is the focus of this paper. The process of transferring antiprotons to the Recycler Ring for subsequent transfer to the collider has been significantly restructured and streamlined, yielding additional cycle time for antiproton production. Improvements to the target station have greatly increased the antiproton yield from the production target. The performance of the Antiproton Source stochastic cooling systems has been enhanced by upgrades to the cooling electronics, accelerator lattice optimization, and improved operating procedures. In this paper, we will briefly report on each of these modifications.

43 PARTICLE ACCELERATORS↗

An Electron Fixed Target Experiment to Search for a New Vector Boson A' Decaying to e+e-

We describe an experiment to search for a new vector boson A' with weak coupling {alpha}' {approx}> 6 x 10{sup -8} {alpha} to electrons ({alpha} = e{sup 2}/4{pi}) in the mass range 65 MeV < m{sub A'} < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the 'dark photon' A' with the photon - one of the very few ways in which new forces can couple to the Standard Model - and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e{sup +}e{sup -} spectrum. We summarize the experimental approach described in a proposal submitted to Jefferson Laboratory's PAC35, PR-10-009. This experiment, the A' Experiment (APEX), uses the electron beam of the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory (CEBAF) at energies of {approx} 1-4 GeV incident on 0.5-10% radiation length Tungsten wire mesh targets, and measures the resulting e{sup +}e{sup -} pairs to search for the A' using the High Resolution Spectrometer and the septum magnet in Hall A. With a {approx} 1 month run, APEX will achieve very good sensitivity because the statistics of e{sup +}e{sup -} pairs will be {approx} 10,000 times larger in the explored mass range than any previous search for the A' boson. These statistics and the excellent mass resolution of the spectrometers allow sensitivity to {alpha}'/{alpha} one to three orders of magnitude below current limits, in a region of parameter space of great theoretical and phenomenological interest. Similar experiments could also be performed at other facilities, such as the Mainz Microtron.

43 PARTICLE ACCELERATORS↗

Apparatus and method for inspecting a sealed container

An apparatus for inspecting a sealed container is disclosed and which includes a pulsed electron accelerator which is positioned in spaced relation relative to a first side of the sealed container, and which produces a pulsed beam of photons which passes through the sealed container and any contents enclosed within the sealed container; a detector positioned in spaced relation relative to a second, opposite side of the sealed container, and which receives the pulsed beam of photons which passes through the contents of the sealed container, and which produces an output signal; and a computer for developing a visible image from the output signal of the detector which depicts the contents of the sealed container.

47 OTHER INSTRUMENTATION↗

LibERI—A portable and performant multi-GPU accelerated library for electron repulsion integrals via OpenMP offloading and standard language parallelism

A portable and performant graphics processing unit (GPU)-accelerated library for electron repulsion integral (ERI) evaluation, named LibERI, has been developed and implemented via directive-based (e.g., OpenMP and OpenACC) and standard language parallelism (e.g., Fortran DO CONCURRENT). Offloaded ERIs consist of integrals over low and high contraction s, p, and d functions using the rotated-axis and Rys quadrature methods. GPU codes are factorized based on previous developments with two layers of integral screening and quartet presorting. In this work, the density screening is moved to the GPU to enhance the computational efficacy for large molecular systems. Here, the L-shells in the Pople basis set are also separated into pure S and P shells to increase the ERI homogeneity and reduce atomic operations and the memory footprint. LibERI is compatible with any quantum chemistry drivers supporting the MolSSI Driver Interface. Benchmark calculations of LibERI interfaced with the GAMESS software package were carried out on various GPU architectures and molecular systems. The results show that the LibERI performance is comparable to other state-of-the-art GPU-accelerated codes (e.g., TeraChem and GMSHPC) and, in some cases, outperforms conventionally developed ERI CUDA kernels (e.g., QUICK) while fully maintaining portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulations of a High-Transformer-Ratio Plasma Wakefield Accelerator Using Multiple Electron Bunches

Particle-in-cell simulations of a plasma wakefield accelerator in the linear regime are presented, consisting of four electron bunches that are fed into a high-density plasma. It is found that a high transformer ratio can be maintained over 43 cm of plasma if the charge in each bunch is increased linearly, the bunches are placed 1.5 plasma wavelengths apart and the bunch emmitances are adjusted to compensate for the nonlinear focusing forces. The generated wakefield is sampled by a test witness bunch whose energy gain after the plasma is six times the energy loss of the drive bunches.

36 MATERIALS SCIENCE↗

The slingshot effect: A possible new laser-driven high energy acceleration mechanism for electrons

We show that under appropriate conditions the impact of a very short and intense laser pulse onto a plasma causes the expulsion of surface electrons with high energy in the direction opposite to the one of the propagations of the pulse. This is due to the combined effects of the ponderomotive force and the huge longitudinal field arising from charge separation (“slingshot effect”). The effect should also be present with other states of matter, provided the pulse is sufficiently intense to locally cause complete ionization. An experimental test seems to be feasible and, if confirmed, would provide a new extraction and acceleration mechanism for electrons, alternative to traditional radio-frequency-based or laser-wake-field ones.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An inverse free electron laser acceleration-driven Compton scattering X-ray source

Abstract The generation of X-rays and γ-rays based on synchrotron radiation from free electrons, emitted in magnet arrays such as undulators, forms the basis of much of modern X-ray science. This approach has the drawback of requiring very high energy, up to the multi-GeV-scale, electron beams, to obtain the required photon energy. Due to the limit in accelerating gradients in conventional particle accelerators, reaching high energy typically demands use of instruments exceeding 100’s of meters in length. Compact, less costly, monochromatic X-ray sources based on very high field acceleration and very short period undulators, however, may enable diverse, paradigm-changing X-ray applications ranging from novel X-ray therapy techniques to active interrogation of sensitive materials, by making them accessible in energy reach, cost and size. Such compactness and enhanced energy reach may be obtained by an all-optical approach, which employs a laser-driven high gradient accelerator based on inverse free electron laser (IFEL), followed by a collision point for inverse Compton scattering (ICS), a scheme where a laser is used to provide undulator fields. We present an experimental proof-of-principle of this approach, where a TW-class CO 2 laser pulse is split in two, with half used to accelerate a high quality electron beam up to 84 MeV through the IFEL interaction, and the other half acts as an electromagnetic undulator to generate up to 13 keV X-rays via ICS. These results demonstrate the feasibility of this scheme, which can be joined with other techniques such as laser recirculation to yield very compact photon sources, with both high peak and average brilliance, and with energies extending from the keV to MeV scale. Further, use of the IFEL acceleration with the ICS interaction produces a train of high intensity X-ray pulses, thus enabling a unique tool synchronized with a laser pulse for ultra-fast strobe, pump-probe experimental scenarios.

43 PARTICLE ACCELERATORS↗

Laser vacuum acceleration of a relativistic electron bunch

With regard to the problem of laser acceleration of a relativistic electron bunch we present a scheme of its vacuum acceleration directly by a relativistic intensity laser pulse. The energy of the electron bunch injected into the laser pulse leading edge increases during its coaxial movement to a thin, pulse-reflecting target. The laser-accelerated electrons continue to move free forward, passing through the target. The study of this acceleration scheme in the three-dimensional geometry is verified in a numerical simulation by the particle-in-cell method, which showed that the energy of a part of the electrons can increase significantly compared to the initial one. Restrictions are discussed, which impose limiting values of energy and total charge of accelerated electrons. (superstrong light fields)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron trapping and acceleration by the plasma wakefield of a self-modulating proton beam

It is shown that co-linear injection of electrons or positrons into the wakefield of the self-modulating particle beam is possible and ensures high energy gain. The witness beam must co-propagate with the tail part of the driver, since the plasma wave phase velocity there can exceed the light velocity, which is necessary for efficient acceleration. If the witness beam is many wakefield periods long, then the trapped charge is limited by beam loading effects. The initial trapping is better for positrons, but at the acceleration stage a considerable fraction of positrons is lost from the wave. For efficient trapping of electrons, the plasma boundary must be sharp, with the density transition region shorter than several centimeters. Positrons are not susceptible to the initial plasma density gradient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical control of electron phase space in plasma accelerators with incoherently stacked laser pulses

It is demonstrated that synthesizing an ultrahigh-bandwidth, negatively chirped laser pulse by incoherently stacking pulses of different wavelengths makes it possible to optimize the process of electron self-injection in a dense, highly dispersive plasma (n{sub 0}∼10{sup 19} cm{sup −3}). Avoiding transformation of the driving pulse into a relativistic optical shock maintains a quasi-monoenergetic electron spectrum through electron dephasing and boosts electron energy far beyond the limits suggested by existing scaling laws. In addition, evolution of the accelerating bucket in a plasma channel is shown to produce a background-free, tunable train of femtosecond-duration, 35–100 kA, time-synchronized quasi-monoenergetic electron bunches. The combination of the negative chirp and the channel permits acceleration of electrons beyond 1 GeV in a 3 mm plasma with 1.4 J of laser pulse energy, thus offering the opportunity of high-repetition-rate operation at manageable average laser power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refine your search to explore more results.