Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Transient X-rays, gamma-rays and neutrons in space

The various astrophysical sources of transient X-ray, gamma-ray, and neutron emission which can produce significant increases in the high-energy (greater than 1 keV) radiation and particle background flux in space. These sources include solar flares, gamma-ray bursts, supernovae, and other astrophysical transients. The observations of these sources are reviewed, and the expected rate of occurrence of their transient emission is examined as a function of intensity and energy.

Lingenfelter, R. E.↗

Autonomous Radiation Monitoring of Small Vessels

Small private vessels are one avenue by which nuclear materials may be smuggled across international borders. While one can contemplate using the terrestrial approach of radiation portal monitors on the navigable waterways that lead to many ports, these systems are ill-suited to the problem. They require vehicles to pass at slow speeds between two closely-spaced radiation sensors, relying on the uniformity of vehicle sizes to space the detectors, and on proximity to link an individual vehicle to its radiation signature. In contrast to roadways where lanes segregate vehicles, and motion is well controlled by inspection booths; channels, inlets, and rivers present chaotic traffic patterns populated by vessels of all sizes. We have developed a unique solution to this problem based on our portal-less portal monitor instrument that is designed to handle free-flowing traffic on roadways with up to five-traffic lanes. The instrument uses a combination of visible-light and gamma-ray imaging to acquire and link radiation images to individual vehicles. It was recently tested in a maritime setting. In this paper we present the instrument, how it functions, and the results of the recent tests.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

MIT bag model inspired partonic transverse momentum distribution for prompt photon production in pp collisions

We consider the prompt photon production in pp collisions using, within the framework of perturbative QCD, a non-Gaussian distribution for the transverse momentum distribution of the partons inside the proton. Our description adopts the widely used in the literature factorization of the partonic momentum distribution into longitudinal and transverse components. It is argued that the non-Gaussian distribution of the intrinsic transverse momenta of the partons is dictated by the asymptotic freedom as well as the 3D confinement of the partons in the proton. To make this association more transparent we use the MIT bag model, which plainly incorporates both properties (asymptotic freedom, confinement), in order to determine in a simplified way the partonic transverse momentum distribution. A large set of data from six different experiments have been fitted with this simple description using as a single free parameter the mean partonic transverse momentum <k{sub T}>. Surprisingly enough, a perfect fit of the experimental data turns out to require <k{sub T}> values which are compatible with Heisenberg's uncertainty relation for the proton and decrease almost smoothly as a function of the scaled variable z=(p{sub T}/{radical}(s)), where p{sub T} is the transverse momentum of the final photon and {radical}(s) is the beam energy in the center of mass frame. Our analysis indicates that asymptotic freedom and 3D confinement may influence significantly the form of the partonic transverse momentum distribution leaving an imprint on the pp{yields}{gamma}+X cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-P-34: Commission of Enhanced Dynamic Wedge of Varian Truebeam Linac System with Feature Study

Purpose: To evaluate an Enhanced Dynamic Wedge (EDW) as part of machine commission process with feature study. Methods: The EDW system in this study was from a Truebeam, which is the Linear accelerator manufactured by Varian Medical Systems. The EDW feature vectors includes selected elements. These elements were dosimetric output spots check, field size, wedge angles, dose rate, collimator orientation, and different energy settings. Point dose measurement was done by a PTW farmer chamber, and profiles were measured by Gafchromic EBT2 films positing at different depths of the Solidwater based on the study elements. The output spot measurements were done with PTW farmer chamber with Solidwater setting for all orientation and wedge angles in the EDW system. The profiles comparisons were done by IMRT measurement function in RIT software at version 6.3. And the films were scanned by Vidar scanner. Dosimetry calculation were done by using the same Solidwater scanned by GE LightSpeed CT in Eclipse Treatment Planning System (TPS). Then measurements were compared to simulation results in TPS. Results: The energy average percentage difference between chamber measurement and TPS was 0.16% with standard deviation (SD) at 0.93%. For selected features, the average percentage difference between film measurement and computation was 0.93% with SD at 1.55% in horizontal profiles, and 1.18% with SD at 0.98% at vertical profiles. The average gamma difference for film measurement and TPS computing results was at 0.924 with SD at 0.314. Conclusion: A feature vector was developed to describe the commission of EDW, and developing a complete set of features for sufficiency of commission of a LINAC function could provide optimal commission instance with acceptable confident level of clinical application of the machine. Given the institution specific vector pattern and big data process, it could provide wide range clinical outcome comparison information in application of EDW.

60 APPLIED LIFE SCIENCES↗

First Evaluation of the Biologic Effectiveness Factors of Boron Neutron Capture Therapy (BNCT) in a Human Colon Carcinoma Cell Line

Purpose: DNA lesions produced by boron neutron capture therapy (BNCT) and those produced by gamma radiation in a colon carcinoma cell line were analyzed. We have also derived the relative biologic effectiveness factor (RBE) of the neutron beam of the RA-3- Argentine nuclear reactor, and the compound biologic effectiveness (CBE) values for p-boronophenylalanine ({sup 10}BPA) and for 2,4-bis ({alpha},{beta}-dihydroxyethyl)-deutero-porphyrin IX ({sup 10}BOPP). Methods and Materials: Exponentially growing human colon carcinoma cells (ARO81-1) were distributed into the following groups: (1) BPA (10 ppm {sup 10}B) + neutrons, (2) BOPP (10 ppm {sup 10}B) + neutrons, (3) neutrons alone, and (4) gamma rays ({sup 60}Co source at 1 Gy/min dose-rate). Different irradiation times were used to obtain total absorbed doses between 0.3 and 5 Gy ({+-}10%) (thermal neutrons flux = 7.5 10{sup 9} n/cm{sup 2} sec). Results: The frequency of micronucleated binucleated cells and the number of micronuclei per micronucleated binucleated cells showed a dose-dependent increase until approximately 2 Gy. The response to gamma rays was significantly lower than the response to the other treatments (p < 0.05). The irradiations with neutrons alone and neutrons + BOPP showed curves that did not differ significantly from, and showed less DNA damage than, irradiation with neutrons + BPA. A decrease in the surviving fraction measured by 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazolium bromide (MTT) assay as a function of the absorbed dose was observed for all the treatments. The RBE and CBE factors calculated from cytokinesis block micronucleus (CBMN) and MTT assays were, respectively, the following: beam RBE: 4.4 {+-} 1.1 and 2.4 {+-} 0.6; CBE for BOPP: 8.0 {+-} 2.2 and 2.0 {+-} 1; CBE for BPA: 19.6 {+-} 3.7 and 3.5 {+-} 1.3. Conclusions: BNCT and gamma irradiations showed different genotoxic patterns. To our knowledge, these values represent the first experimental ones obtained for the RA-3 in a biologic model and could be useful for future experimental studies for the application of BNCT to colon carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD)-induced cytotoxicity accompanied by oxidative stress in rat Sertoli cells: Possible role of mitochondrial fractions of Sertoli cells

TCDD, as an endocrine disruptor, is known to impair testicular functions and fertility. To elucidate the mechanism(s) underlying the testicular effects of TCDD, the potential toxicity of TCDD on Sertoli cells was investigated. Furthermore, the study aims to delineate whether mitochondrial fractions of Sertoli cells are involved in mediating the testicular effects of TCDD. Adult rat Sertoli cells were incubated with (5, 10 or 15 nM) of TCDD for 6, 12 or 24 h. Cell viability, lactate and LDH leakage into media along with lipid peroxidation, ROS generation, SOD, CAT, GPx, GR, {gamma}-GT and {beta}-glucuronidase activities, GSH content and {Delta}{psi}{sub m} were measured. Superoxide anion production, COX and cardiolipin content were measured in mitochondrial fractions. Cell viability was significantly decreased while lactate and LDH leakage into media were increased. ROS generation along with lipid peroxidation was also increased. SOD, CAT, GPx, GR activities and GSH content were significantly decreased. {gamma}-GT and {beta}-glucuronidase activities were also decreased. Superoxide anion production was increased while COX activity and cardiolipin content were decreased in mitochondrial fractions. Moreover, the {Delta}{psi}{sub m} was significantly decreased as measured in Sertoli cells. In conclusion, TCDD impairs Sertoli cell functions and this effect is, at least in part, attributed to oxidative stress. We have also found that TCDD increases mitochondrial superoxide anion production and decreases {Delta}{psi}{sub m}, COX activity and mitochondrial cardiolipin content. Our findings suggest that mitochondria may play an important role in ROS production, leading to the TCDD-induced oxidative stress response and resulting toxicological consequences in rat Sertoli cells.

60 APPLIED LIFE SCIENCES↗

Gamma-ray continuum and line observations of SN 1987A

The Caltech gamma-ray imaging telescope observed the hard X-ray and gamma-ray emission from SN 1987A as it evolved between 1987 May and 1989 April, in a series of four balloon flights from Alice Springs, NT, Australia. Observations of the Crab Nebula and Pulsar provided in-flight data on pointing accuracy and instrument function for each flight. Results presented here include our measurements on November 18, 1987 (D268) and April 12, 1988 (D414) of both line emission at 847 and 1238 keV from the decay of Co-56, and Compton-scattered continuum above 50 keV. Upper limits for both line and continuum emission were obtained on May 20, 1987 (D86) and April 4, 1989 (D771). For the D268 and D414 continuum measurements, our results are best-fit by a differential power law of the form dN/dE = kE exp -gamma (sq cm s keV) for the energy range 50-800 keV. Our corresponding line measurements were fit with Gaussian profiles, containing additional terms for the underlying continuum. We compare our flux measurements and upper limits to those from other experiments and to predictions of theoretical models.

Palmer, D. M.↗

Search for the Pygmy Dipole Resonance in {sup 68}Ni at 600 MeV/nucleon

The {gamma} decay from Coulomb excitation of {sup 68}Ni at 600 MeV/nucleon on a Au target was measured using the RISING setup at the fragment separator of GSI. The {sup 68}Ni beam was produced by a fragmentation reaction of {sup 86}Kr at 900 MeV/nucleon on a {sup 9}Be target and selected by the fragment separator. The {gamma} rays produced at the Au target were measured with HPGe detectors at forward angles and with BaF{sub 2} scintillators at backward angles. The measured spectra show a peak centered at approximately 11 MeV, whose intensity can be explained in terms of an enhanced strength of the dipole response function (pygmy resonance). Such pygmy structure has been predicted in this unstable neutron-rich nucleus by theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photometry of the 4686 A emission line of gamma(2) Velorum from the South Pole

An automated optical telescope located at the Amundsen-Scott South Pole station on Antarctica, has been used to obtain more than 78 h of photometry of the He II emission line (4686 A) of the spectroscopic binary gamma(2) Velorum. These data were obtained on seven different days during the 1987 austral winter; the longest continuous run spans 19 h. Two independent period search techniques have been used to search for periodic behavior in the strength of the He II emission line of this Wolf-Rayet star. They are: (1) power spectrum analysis and (2) a first-order sine function fit to the data using least squares. Various multiplicities of a period on the order of 1.3 h with amplitudes of a few percent are found in most of these data. According to recent theoretical models of Wolf-Rayet stars, fluctuations in the He II emission line may indicate vibrational instability in gamma(2) Vel. These pulsations may, in turn, give rise to shocks which propagate outward and which may provide the necessary conditions for periodic changes in the state of a given region of the atmosphere to occur.

Taylor, Maryjane↗

Accurate Holdup Calculations with Predictive Modeling & Data Integration

In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantity and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use Bayes’ Theorem, one must have a model y(x) that maps the state variables x (the solution in this case) to the measurements y. In this case, the unknown state variables are the configuration and composition of the heldup SNM. The measurements are the detector readings. Thus, the natural model is neutral-particle radiation transport where a wealth of computational tools exists for performing these simulations accurately and efficiently. The combination of predictive model and Bayesian inference forms the Data Integration with Modeled Predictions (DIMP) method that serves as foundation for this project. The cost functional describing the model-to-data misfit is computed via a norm created by the inverse of the covariance matrix of the model parameters and responses. Since the model y(x) for the holdup problem is nonlinear, a nonlinear optimization on Q is conducted via Newton-type iterative methods to find the optimal values of the model parameters x. This project comprised a collaboration between NC State University (NCSU), the University of South Carolina (USC), and Oak Ridge National Laboratory (ORNL). The project was originally proposed in seven main tasks with an eighth contingency task to be performed if time and funding permitted; in fact time did not permit commencement of the contingency task and it was not performed. The remaining tasks involved holdup analysis with gamma detection strategies and separately with neutrons based on coincidence counting. Early in the project, and upon consultation with experts in coincidence counting it became evident that this approach is not viable for holdup applications and this task was replaced with an alternative, but valuable investigation that was carried out by the USC partner. Nevertheless, the experimental 4 measurements at ORNL of both gamma and neutron sources for the purpose of constructing Detector Response Functions (DRFs) with the associated uncertainties were indeed completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GAMMA-RAY OBSERVATIONAL PROPERTIES OF TeV-DETECTED BLAZARS

The synergy between the Fermi-LAT and ground-based Cherenkov telescope arrays gives us the opportunity for the first time to characterize the high-energy emission from blazars over 5 decades in energy, from 100 MeV to 10 TeV. In this study, we perform a Fermi-LAT spectral analysis for TeV-detected blazars and combine it with archival TeV data. We examine the observational properties in the {gamma}-ray band of our sample of TeV-detected blazars and compare the results with X-ray and GeV-selected populations. The spectral energy distributions (SEDs) that result from combining Fermi-LAT and ground-based spectra are studied in detail. Simple parameterizations such as a power-law function do not always reproduce the high-energy SEDs, where spectral features that could indicate intrinsic absorption are observed.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of atmospheric gamma-ray flashes detected in near space with allowance for the transport of photons in the atmosphere

Monte Carlo simulations of transport of the bremsstrahlung produced by relativistic runaway electron avalanches are performed for altitudes up to the orbit altitudes where terrestrial gamma-ray flashes (TGFs) have been detected aboard satellites. The photon flux per runaway electron and angular distribution of photons on a hemisphere of radius similar to that of the satellite orbits are calculated as functions of the source altitude z. The calculations yield general results, which are recommended for use in TGF data analysis. The altitude z and polar angle are determined for which the calculated bremsstrahlung spectra and mean photon energies agree with TGF measurements. The correlation of TGFs with variations of the vertical dipole moment of a thundercloud is analyzed. We show that, in agreement with observations, the detected TGFs can be produced in the fields of thunderclouds with charges much smaller than 100 C and that TGFs are not necessarily correlated with the occurrence of blue jets and red sprites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dodecane Radiolysis Yields by Time-Resolved and Steady-State Methods

Liquid organic molecules are present as solvents, complexing ligands, and additives in both used nuclear fuel reprocessing solvent systems and in their subsequent nuclear waste streams. Under these extreme environments, these organic molecules are constantly exposed to ionizing radiation which promotes their radiolysis, forming a variety of short-lived, highly energetic, excited state and radical species.1-4 Here, we demonstrate new experimental results for the steady-state and time-resolved irradiations of dodecane (C12H26), a long chain, liquid, aliphatic hydrocarbon that is the prototypical solvent used for benchtop studies of aqueous-organic solvent extraction systems. When ionizing radiation interacts with neat dodecane, the energy transfer can result in molecular ionization, to give the dodecane radical cation (C12H26+•) and the solvated electron (eS–), and molecular electronic excitation (C12H26*), which rapidly produces transient carbon-centered radical fragments (CxHy•) and hydrogen atoms (H•).1-4 Studies on the initial yields of the ionization and excitation products were performed using time-resolved picosecond electron pulse radiolysis with the use of molecular probes. Using steady-state cobalt-60 gamma irradiations, the suite of products formed by dodecane radiolysis in aerated and deaerated solutions was determined. Then, using iodine as an alkyl radical scavenger, the loss of molecular iodine with dose was quantified, and by correlating with the molecular hydrogen yields of the system, the initial yields of the various carbon-centered radicals were also determined. Finally, the rates of reactions of the C12H26+• and eS– with ligands proposed for use in spent nuclear fuel reprocessing were studied as a function of temperature from 10 – 40 °C.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Positron Production at JLab Simulated Using Geant4

The results of a Geant4 Monte-Carlo study of the production of slow positrons using a 140 MeV electron beam which might be available at Jefferson Lab are presented. Positrons are produced by pair production for the gamma-rays produced by bremsstrahlung on the target which is also the stopping medium for the positrons. Positrons which diffuse to the surface of the stopping medium are assumed to be ejected due to a negative work function. Here the target and moderator are combined into one piece. For an osmium target/moderator 3 cm long with transverse dimensions of 1 cm by 1 mm, we obtain a slow positron yield of about 8.5centre dot10{sup 10}/(scentre dotmA) If these positrons were remoderated and re-emitted with a 23% probability we would obtain 2centre dot10{sup 10}/(scentre dotmA) in a micro-beam.

43 PARTICLE ACCELERATORS↗

Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n'γ) reactions towards lower energies and the isotropic character of scattering of the secondary neutrons may lead to the observed limitation of the length of effective interaction, since a fraction of the secondary neutrons that propagate in the forward direction are not subject to further inelastic scattering because of their substantially lower energy. At these reduced energies, it is the capture cross-section (n, γ) that becomes predominant, resulting in lower detection efficiency. Based on these results, several types of detectors have been envisioned for application in detection systems for nuclear materials. The testing results for one such detector are presented in this work. We have studied the possibility of creation of a composite detector with scintillator granules placed inside a transparent polymer material. Because of the low transparency of such a dispersed scintillator, better light collection conditions are ensured by incorporation of a light guide between the scintillator layers. This guide is made of highly transparent polymer material. The use of a high-transparency hydrogen-containing polymer material for light guides not only ensures optimum conditions of light collection in the detector, but also allows certain deceleration of neutron radiation, increasing its interaction efficiency with the composite scintillation panels; accordingly, the detector signal is increased by 5-8%. When fast neutrons interact with the scintillator material, the resulting inelastic scattering gamma-quanta emerge, having different energies and different delay times with respect to the moment of the neutron interaction with the nucleus of the scintillator material (delay times ranging from 1x10{sup -9} to 1.3x10{sup -6} s). These internally generated gamma-quanta interact with the scintillator, and the resulting scintillation light is recorded by the photo-receiver. Since neutron sources are also strong sources of low-energy gamma-radiation, the use of dispersed ZnSe(Te) scintillator material provides high gamma-radiation detection efficiency in that energy range. This new type of gamma-neutron detector is based on a 'sandwich' structure using a ZnSe composite film and light guide with a fast neutron detection efficiency of about 6%. Its high detection efficiency of low-energy gamma-radiation allows a substantial increase (by an order of magnitude) in the efficiency of detection of neutron sources and transuranic materials by means of simultaneous detection of accompanying gamma-radiation. The design and fabrication technology of this detector allows the creation of gamma-neutron detectors characterized by high sensitivity at relatively low costs (as compared with analogs using oxide scintillators) for portable inspection systems. The sandwich structure can be comprised of any number of plates, with no limitations on thickness or area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

Fast radio burst/gamma-ray burst cosmography

Recently, both theoretical arguments and observational evidence suggested that a small fraction of fast radio bursts (FRBs) could be associated with gamma-ray bursts (GRBs). If such FRB/GRB association systems are commonly detected in the future, the combination of dispersion measures (DM) derived from FRBs and redshifts derived from GRBs makes these systems a plausible tool to conduct cosmography. We quantify uncertainties in deriving the redshift-dependent DM{sub IGM} as a function of z and test how well dark energy models can be constrained with Monte Carlo simulations. We show that with several tens of FRB/GRB systems potentially detected in a decade or so, one may reach reasonable constraints on wCDM models. When combined with Type Ia supernova (SN Ia) data, unprecedented constraints on the dark energy equation of state may be achieved, thanks to the prospects of detecting FRB/GRB systems at relatively high redshifts. The ratio between the mean value and luminosity distance (D {sub L}(z)) is insensitive to dark energy models. This gives the prospect of applying SN Ia data to calibrate using a relatively small sample of FRB/GRB systems, allowing a reliable constraint on the baryon inhomogeneity distribution as a function of redshift. The methodology developed in this paper can also be applied if the FRB redshifts can be measured by other means. Some caveats of putting this method into practice are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Immunoglobulin Fc gamma receptor promotes immunoglobulin uptake, immunoglobulin-mediated calcium increase, and neurotransmitter release in motor neurons

Receptors for the Fc portion of immunoglobulin G (IgG; FcgammaRs) facilitate IgG uptake by effector cells as well as cellular responses initiated by IgG binding. In earlier studies, we demonstrated that amyotrophic lateral sclerosis (ALS) patient IgG can be taken up by motor neuron terminals and transported retrogradely to the cell body and can alter the function of neuromuscular synapses, such as increasing intracellular calcium and spontaneous transmitter release from motor axon terminals after passive transfer. In the present study, we examined whether FcgammaR-mediated processes can contribute to these effects of ALS patient immunoglobulins. F(ab')(2) fragments (which lack the Fc portion) of ALS patient IgG were not taken up by motor axon terminals and were not retrogradely transported. Furthermore, in a genetically modified mouse lacking the gamma subunit of the FcR, the uptake of whole ALS IgG and its ability to enhance intracellular calcium and acetylcholine release were markedly attenuated. These data suggest that FcgammaRs appear to participate in IgG uptake into motor neurons as well as IgG-mediated increases in intracellular calcium and acetylcholine release from motor axon terminals. Copyright 2002 Wiley-Liss, Inc.

Non-NASA Center↗

Refine your search to explore more results.