Chalcogenide Glass-Capped Fiber-Optic Sensor for Real-Time Temperature Monitoring in Extreme Environments

We demonstrate a novel chalcogenide glass (ChG)-capped optical fiber temperature sensor capable of operating within harsh environment. The sensor architecture utilizes the heat-induced phase change (amorphous-to-crystalline) property of ChGs, which rapidly (80–100 ns) changes the optical properties of the material. The sensor response to temperature variation around the phase change of the ChG cap at the tip of the fiber provides abrupt changes in the reflected power intensity. This temperature is indicative of the temperature at the sensing node. We present the sensing performance of six different compositions of ChGs and a method to interpret the temperature profile between 440 °C and 600 °C in real-time using an array structure. The unique radiation-hardness property of ChGs makes the devices compatible with high-temperature and high-radiation environments, such as monitoring the cladding temperature of Light Water (LWR) or Sodium-cooled Fast (SFR) reactors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Nonradiative Properties of Self–Trapped Holes in Ultra–Wide Bandgap Gallium Oxide Film

The photoluminescence (PL) of self-trapped holes (STH) in ultra-wide bandgap β-Ga 2 O 3 is commonly its most dominant light emission and is an inherent property. Thus, gaining knowledge of the crystal dynamics that impact the PL properties is vital to sensor and other technologies. The PL, Raman-phonons, and their interactions are studied at an extreme temperature range of 77–622 K. The PL is studied up to the bandgap value of ≈5 eV. It is found that the high-energy Raman modes provide a major route to the nonradiative process of the PL via STH–phonon interaction with an activation energy of 72 meV. This dynamic is modeled with the configurational coordinate scheme at the strong phonon coupling limit. The exceptionally broad Gaussian PL linewidth manifests this coupling. The weak temperature response of the PL energy peak position indicates that the STH has characteristics of a deep-level defect. This contrasts with the large redshift of ≈220 meV of the optical gap of the film, ascertained from transmission. Unlike the temperature response of the high-energy phonons, the behavior of the low-energy phonons is found to follow the Bose–Einstein population increase, indicating no strong interaction with the STH.

Raman↗

Ceramic thick film humidity sensor based on MgTiO{sub 3} + LiF

Graphical abstract: - Highlights: • The fabricated sensor based on MgTiO{sub 3} + LiF materials used the spin coating technology. • The response time is 70 s to detect variation between 5 and 95% relative humidity. • The addition of Scleroglucan controls the viscosity and decreases the roughness of thick film surface. • This humidity sensor is a promising, low-cost, high-quality, reliable ceramic films, that is highly sensitive to humidity. - Abstract: The feasibility of humidity sensor, consisting of a thick layer of MgTiO{sub 3}/LiF materials on alumina substrate, was studied. The thermal analysis TGA-DTGA and dilatometric analysis worked out to confirm the sintering temperature. An experimental plan was applied to describe the effects of different parameters in the development of the thick film sensor. Structural and microstructural characterizations of the developed thick film were made. Rheological study with different amounts of a thickener (scleroglucan “sclg”), showing the behavior variation, as a function of sclg weight % was illustrated and rapprochement with the results of thickness variation as a function of angular velocity applied in the spin coater. The electrical and dielectric measurements confirmed the sensitivity of the elaborated thick film against moisture, along with low response time.

36 MATERIALS SCIENCE↗

Light-Driven Expansion of Spiropyran Hydrogels

The incorporation of molecular switches in organic structures is of great interest in the chemical design of stimuli-responsive materials that mimic the complex functions of living systems. Merocyanine dyes that convert to spiropyran moieties upon exposure to visible light have been extensively studied as they can be incorporated in hydrated covalent networks that will expel water when this conversion occurs and induce a volumetric shrinkage. We report here on a sulfonatebased water soluble photoswitch that in contrast to the well-known system triggers a volumetric expansion in hydrogels upon exposure to photons. Contraction is in turn observed under dark conditions in a highly reversible manner. The novel behavior of the photoswitch incorporated in the covalent network was also predicted by coarse grain simulations of the system’s chemical structure. Using pH control and polymeric structures that differ in lower critical solution temperature we were able to develop hydrogels with highly tunable volumetric expansion. Furthermore, the novel molecular function of the systems developed here led to materials with the negative phototaxis observed in plants, and can expand the potential use of hydrogels as sensors, soft robots, and actuators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser surface modification of medical grade alloys for reduced heating in a magnetic resonance imaging environment

Nanoscale surface modification of medical grade metallic alloys was conducted using a neodymium-doped yttrium aluminum garnet laser-based dopant diffusion technique. The objective of this approach was to minimize the induction heating by reducing the absorbed radio frequency field. Such an approach is advantageous in that the dopant is diffused into the alloy and is not susceptible to detachment or spallation as would an externally applied coating, and is expected to not deteriorate the mechanical and electrical properties of the base alloy or device. Experiments were conducted using a controlled environment laser system with the ability to control laser properties (i.e., laser power, spot size, and irradiation time) and dopant characteristics (i.e., temperature, concentration, and pressure). The reflective and transmissive properties of both the doped and untreated samples were measured in a radio frequency (63.86 MHz) magnetic field using a system comprising a high power signal generator, a localized magnetic field source and sensor, and a signal analyzer. The results indicate an increase in the reflectivity of the laser-treated samples compared to untreated samples. The effect of reflectivity on the heating of the alloys is investigated through a mathematical model incorporating Maxwell’s equations and heat conduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation systems for the Langley Research Center 8-foot high temperature tunnel

A description is presented of the 8-foot high-temperature tunnel, a Mach 7 blowdown-type facility in which methane is burned in air under pressure, with the resulting combustion products utilized as the test medium. The instrumentation environment and requirements are identified, and instrumentation design, including wiring, sensors, and data acquisition system are described. The design and installation of a fast oxygen monitoring system to maintain the partial pressure of oxygen at 21 percent in the tunnel test section is included. Also, the new data acquisition system hardware details and data-reduction capabilities are defined.

Walsh, James J., Jr.↗

A photoelastic fiber optic strain gage

This paper reports on the development of a photoelastic fiber optic strain gage sensitive to transverse strain. The sensing element is made from an epoxy resin which is stress frozen to passively achieve the quadrature condition. Light, emitted from an LED operating at 820 nm, is transmitted to and from the sensing element via multimode fibers and the signal is detected using a dual channel operational photodiode/amplifier. This unique combination of optics and electronics produces a fiber optic sensor having a high signal to noise ratio which is lead-in/out insensitive. Results show that strains on the order of 1 microstrain can be measured over an 800 microstrain range and that dummy gages can be used for temperature compensation.

Su, Wei↗

Ground-based measurement of surface temperature and thermal emissivity

Motorized cable systems for transporting infrared thermometers have been used successfully during several international field campaigns. Systems may be configured with as many as four thermal sensors up to 9 m above the surface, and traverse a 30 m transect. Ground and canopy temperatures are important for solving the surface energy balance. The spatial variability of surface temperature is often great, so that averaged point measurements result in highly inaccurate areal estimates. The cable systems are ideal for quantifying both temporal and spatial variabilities. Thermal emissivity is also necessary for deriving the absolute physical temperature, and measurements may be made with a portable measuring box.

Owe, M.↗

Experimental and Numerical Characterization of a Cylindrical Blackbody Cavity

During hypersonic flight, high temperatures and high heat fluxes are generated on the surfaces of vehicles. The Flight Loads Laboratory (FLL) at Dryden Flight Research Center (DFRC) is equipped with a calibration furnace, capable of calibrating heat flux gages up to 1100kW per square meters, and temperature sensors up to 2600 C. One heating configuration of the calibration furnace is a cylindrical blackbody cavity. Throughout the blackbody there are temperature gradients due to various boundary conditions. These boundary conditions include resistance heating, radiant heat transfer, and conduction to water-cooled electrodes. Also, an inert gas is purged through the graphite blackbody to prevent it from oxidizing. Consequently, the various modes of heat transfer present during operation of the blackbody cavity must be well understood in order to produce accurate heat flux gage and temperature sensor calibrations for use in ground testing or flight testing of hypersonic vehicles. The first step towards understanding the heat transfer in the blackbody cavity was to perform experiments at 1100 C, with and without outer surface insulation, while taking detailed temperature measurements inside the blackbody cavity. Steady state thermal models of the blackbody cavity were then developed. These models included detailed thermal analysis using commercial thermal analysis software. Conduction, radiation, and convection were considered in the thermal models for two cases: one with the outside of the blackbody cavity insulated and the second without insulation. This paper describes the experimental and numerical efforts used to characterize the steady state operation of the blackbody cavity. It describes the analysis of the test measurements, the boundary conditions used in the numerical models, and how the models were calibrated to fit the experimental data. Effects of various uncertainties, such as material properties, and convection are discussed.Initial thermal models predicted temperatures in the deepest part of the blackbody cavity within 7 C of the measured value and produced trends comparable to the experimental data, throughout the models. Adjustment of the boundary conditions, which were included in the thermal models, produced good agreement with measured temperatures. Free and forced convection of the purge gas inside the blackbody was found to be insignificant.

Abdelmessih, Amanie N.↗

Improved Correction System for Vibration Sensitive Inertial Angle of Attack Measurement Devices

Inertial angle of attack (AoA) devices currently in use at NASA Langley Research Center (LaRC) are subject to inaccuracies due to centrifugal accelerations caused by model dynamics, also known as sting whip. Recent literature suggests that these errors can be as high as 0.25 deg. With the current AoA accuracy target at LaRC being 0.01 deg., there is a dire need for improvement. With other errors in the inertial system (temperature, rectification, resolution, etc.) having been reduced to acceptable levels, a system is currently being developed at LaRC to measure and correct for the sting-whip-induced errors. By using miniaturized piezoelectric accelerometers and magnetohydrodynamic rate sensors, not only can the total centrifugal acceleration be measured, but yaw and pitch dynamics in the tunnel can also be characterized. These corrections can be used to determine a tunnel's past performance and can also indicate where efforts need to be concentrated to reduce these dynamics. Included in this paper are data on individual sensors, laboratory testing techniques, package evaluation, and wind tunnel test results on a High Speed Research (HSR) model in the Langley 16-Foot Transonic Wind Tunnel.

Crawford, Bradley L.↗

Studies of the Superconducting Transition in the Mo/Au-Bilayer Thin Films

At NASA Goddard, microcalorimeter arrays using superconducting transition edge sensor thermometers (TESs) are under development for high energy resolution X-ray astrophysics applications. We report on our studies of the superconducting transition in our Mo/Au-bilayer TES films including: low current measurements of the superconducting bilayer's resistance transition versus temperature on pixels with different normal metal absorber attachment designs and measured temperature scaling of the critical current and critical magnetic field.

Sadleir, John↗

Assembly Development for the Simons Observatory Focal Plane Readout Module

The Simons Observatory (SO) is a suite of instruments sensitive to temperature and polarization of the cosmic microwave background (CMB) to be located at Cerro Toco in the Atacama Desert in Chile. Five telescopes, one large aperture telescope and four small aperture telescopes, will host roughly 70,000 highly multiplexed transition edge sensor (TES) detectors operated at 100 mK. Each SO focal plane module (UFM) couples 1,764 TESes to microwave resonators in a microwave multiplexing (μMux) readout circuit. Before detector integration, the100 mKμMux components are packaged into multiplexing modules (UMMs), which are independently validated to ensure they meet SO performance specifications. Here we present the assembly developments of these UMM readout packages for mid frequency (90/150 GHz) and ultra high frequency (220/280 GHz) UFMs.

Aamir M. Ali↗

Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor

A thermoelectric biosensor for the detection of L-glutamate concentration was developed. The thermoelectric sensor is integrated into a micro-calorimeter which measures the heat produced by biochemical reactions. The device contains a single flow channel that is 120 µm high and 10 mm wide with two fluid inlets and one fluid outlet. An antimony-bismuth (Sb-Bi) thermopile with high common mode rejection ratio is attached to the lower channel wall and measures the dynamic changes in the temperature when L-glutamate undergoes oxidative deamination in the presence of glutamate oxidase (GLOD). The thermopile has a Seebeck coefficient of ~7 µV·(m·K)-1 . The device geometry, together with hydrodynamic focusing, eliminates the need of extensive temperature control. Layer-by-layer assembly is used to immobilize GLOD on the surface of glass coverslips by alternate electrostatic adsorption of polyelectrolyte and GLOD. The impulse injection mode using a 6-port injection valve minimizes sample volume to 5 µL. The sensitivity of the sensor for glutamate is 17.9 nVs·mM-1 in the linear range of 0–54 mM with an R2 value of 0.9873. The lowest detection limit of the sensor for glutamate is 5.3 mM.

layer-by-layer self-assembly↗

Interpretation of Fracture Initiation Points by In-Well Low-Frequency Distributed Acoustic Sensing in Horizontal Wells

Summary Low-frequency distributed acoustic sensing (LF-DAS) exploits the optical phase shift of Rayleigh backscatter in fiber-optic cables to obtain distributed measurements of changes in strain and temperature. Fiber-optic cables are often installed for multistage hydraulic fracture diagnostics in horizontal wells. LF-DAS in an untreated well provides far-field strain measurements, while offset wells are hydraulically fractured. Such a configuration is called crosswell LF-DAS sensing. Crosswell LF-DAS measurements have proved useful in diagnosing fracture hits, fracture azimuth, planarity, cluster efficiency, fracture propagation rates, and the dynamic distance to the fracture front. In contrast, in-well LF-DAS is conducted on the actively fractured well. Due to cool fracture fluid being injected at high injection rates, the strain component of the LF-DAS response is largely obscured by temperature changes. In permanent fiber-optic cable installations, distributed temperature sensing (DTS) is often conducted simultaneously with LF-DAS. An opportunity exists to decouple the temperature and strain components of LF-DAS sensors to observe strain changes on in-well LF-DAS. The LF-DAS response is modeled as linearly dependent on strain and temperature changes. Theoretical LF-DAS temperature and strain sensitivity coefficients are derived based on the changes to the index of refraction and length of the fiber. Using the DTS measurements, temperature changes are computed, smoothed, filtered, and compared to the LF-DAS response. Crossplots of the in-well LF-DAS measurements and temperature changes from DTS measurements far from the actively fractured region are used to validate the theoretical sensitivity coefficients. Uncertainty in the temperature component of the LF-DAS response is quantified. The difficulty in corresponding the different spatial and temporal resolutions of the DTS and LF-DAS measurements is overcome by comparing the responses over a moving temporal and spatial window. If the LF-DAS response at the center of the window agrees with the DTS response within uncertainty, the measurement is filtered out. After filtering, the remaining nonzero in-well LF-DAS measurements are due to changes in strain. The data are then visualized in waterfall plots. The results indicate that the theoretical and observed strain and temperature coefficients agree within 10%. After the temperature component of the in-well LF-DAS response is extracted, the remaining nonzero measurements are located primarily within the actively treated region. Locations with peaks in the strain response are interpreted to indicate fracture initiation points. These fracture initiation points are compared with in-well DTS and high-frequency DAS noise measurements across multiple stages to better understand fracture initiation along the horizontal well.

Engineering↗

Nitrogen-doped hollow carbon nanospheres for highly sensitive electrochemical sensing of nitrobenzene

Highlights: • NHCPs were prepared using MSM as a template and PDA as carbon and nitrogen precursor. • NHCPs-750 with high content of pyrindinic N showed good electrocatalytic performance. • A sensitive electrochemical sensor for NB was developed based on the NHCPs-750–GCE. - Abstract: Following hard template method, nitrogen–doped hollow carbon nanospheres (NHCPs) were successfully prepared by using monodisperse silica microspheres as a template and dopamine as carbon and nitrogen precursor. A series of NHCPs-x samples with different pyrolysis temperatures were reported. The composite material formation was characterized by detailed methods (e.g., X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy and transmission electron microscopy). Results indicated that NHCPs treated at 750 °C with highest amounts of pyrindinic N showed improved electro-catalytic activity for nitrobenzene (NB) in neutral solution. NHCPs-750 can be developed as an effective sensing platform for the detection of NB, which showed high activity and superior analytical performance, such as a wide linear range of 5–2610 μM, a high sensitivity of 436 μAmM{sup −1}, and a low limit of detection of 2.29 μM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bright Semiconductor Scintillator for High Resolution X-Ray Imaging

We report on a novel approach to produce oxygen-doped zinc telluride (ZnTe:O), a remarkable group II-VI semiconductor scintillator, fabricated in the columnar-structured or polycrystalline forms needed to fulfill the needs of many demanding X-ray and {gamma}-ray imaging applications. ZnTe:O has one of the highest conversion efficiencies among known scintillators, emission around 680 nm (which is ideally suited for CCD sensors), high density of 6.4 g/cm{sup 3}, fast decay time of {approx}1 {micro}s with negligible afterglow, and orders of magnitude higher radiation resistance compared to commonly used scintillators. These properties allow the use of ZnTe:O in numerous applications, including X-ray imaging, nuclear medicine (particularly SPECT), room temperature radioisotope identification, and homeland security. Additionally, ZnTe:O offers distinct advantages for synchrotron-based high resolution imaging due to the absence of atomic absorption edges in the low energy range, which otherwise reduce resolution due to secondary X-ray formations. We have fabricated films of ZnTe:O using a vapor deposition technique that allows large-area structured scintillator fabrication in a time- and cost-efficient manner, and evaluated its performance for small-angle X-ray scattering (SAXS) at an Argonne National Laboratory synchrotron beamline. Details of the fabrication and characterization of the optical, scintillation and imaging properties of the ZnTe:O films are presented in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Porous silicon-VO{sub 2} based hybrids as possible optical temperature sensor: Wavelength-dependent optical switching from visible to near-infrared range

Morphological properties of thermochromic VO{sub 2}—porous silicon based hybrids reveal the growth of well-crystalized nanometer-scale features of VO{sub 2} as compared with typical submicron granular structure obtained in thin films deposited on flat substrates. Structural characterization performed as a function of temperature via grazing incidence X-ray diffraction and micro-Raman demonstrate reversible semiconductor-metal transition of the hybrid, changing from a low-temperature monoclinic VO{sub 2}(M) to a high-temperature tetragonal rutile VO{sub 2}(R) crystalline structure, coupled with a decrease in phase transition temperature. Effective optical response studied in terms of red/blue shift of the reflectance spectra results in a wavelength-dependent optical switching with temperature. As compared to VO{sub 2} film over crystalline silicon substrate, the hybrid structure is found to demonstrate up to 3-fold increase in the change of reflectivity with temperature, an enlarged hysteresis loop and a wider operational window for its potential application as an optical temperature sensor. Such silicon based hybrids represent an exciting class of functional materials to display thermally triggered optical switching culminated by the characteristics of each of the constituent blocks as well as device compatibility with standard integrated circuit technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications

Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.

25 ENERGY STORAGE↗