Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Advanced Accessory Power Supply Topologies

This Cooperative Research and Development Agreement (CRADA) began December 8, 2000 and ended September 30, 2009. The total funding provided by the Participant (General Motors Advanced Technology Vehicles [GM]) during the course of the CRADA totaled $1.2M enabling the Contractor (UT-Battelle, LLC [Oak Ridge National Laboratory, a.k.a. ORNL]) to contribute significantly to the joint project. The initial task was to work with GM on the feasibility of developing their conceptual approach of modifying major components of the existing traction inverter/drive to develop low cost, robust, accessory power. Two alternate methods for implementation were suggested by ORNL and both were proven successful through simulations and then extensive testing of prototypes designed and fabricated during the project. This validated the GM overall concept. Moreover, three joint U.S. patents were issued and subsequently licensed by GM. After successfully fulfilling the initial objective, the direction and duration of the CRADA was modified and GM provided funding for two additional tasks. The first new task was to provide the basic development for implementing a cascaded inverter technology into hybrid vehicles (including plug-in hybrid, fuel cell, and electric). The second new task was to continue the basic development for implementing inverter and converter topologies and new technology assessments for hybrid vehicle applications. Additionally, this task was to address the use of high temperature components in drive systems. Under this CRADA, ORNL conducted further research based on GM’s idea of using the motor magnetic core and windings to produce bidirectional accessory power supply that is nongalvanically coupled to the terminals of the high voltage dc-link battery of hybrid vehicles. In order not to interfere with the motor’s torque, ORNL suggested to use the zero-sequence, highfrequency harmonics carried by the main fundamental motor current for producing the accessory power. Two studies were conducted at ORNL. One was to put an additional winding in the motor slots to magnetically link with the high frequency of the controllable zero-sequence stator currents that do not produce any zero-sequence harmonic torques. The second approach was to utilize the corners of the square stator punching for the high-frequency transformers of the dc/dc inverter. Both approaches were successful. This CRADA validated the feasibility of GM’s desire to use the motor’s magnetic core and windings to produce bidirectional accessory power supply. Three joint U.S. patents with GM were issued to ORNL and GM by the U.S. Patent Office for the research results produced by this CRADA.

30 DIRECT ENERGY CONVERSION↗

Bipolar Ag-Zn battery

The silver-zinc (AgZn) battery system has been unique in its ability to safely satisfy high power demand applications with low mass and volume. However, a new generation of defense, aerospace, and commercial applications will impose even higher power demands. These new power demands can be satisfied by the development of a bipolar battery design. In this configuration the power consuming, interelectrode current conductors are eliminated while the current is then conducted via the large cross-section electrode substrate. Negative and positive active materials are applied to opposite sides of a solid silver foil substrate. In addition to reducing the weight and volume required for a specified power level, the output voltage performance is also improved as follows. Reduced weight through: elimination of the plastic cell container; elimination of plate leads and intercell connector; and elimination of internal plate current collector. Increased voltage through: elimination of resistance of current collector; elimination of resistance of plate lead; and elimination of resistance of intercell connector. EPI worked previously on development of a secondary bipolar silver zinc battery. This development demonstrated the electrical capability of the system and manufacturing techniques. One difficulty with this development was mechanical problems with the seals. However, recent improvements in plastics and adhesives should eliminate the major problem of maintaining a seal around the periphery of the bipolar module. The seal problem is not as significant for a primary battery application or for a requirement for only a few discharge cycles. A second difficulty encountered was with activation (introducing electrolyte into the cell) and with venting gas from the cell without loss of electrolyte. During previous work, the following projections for energy density were made from test data for a high power system which demonstrated in excess of 50 discharge/charge cycles. Projected system power = 100 kilowatts; discharge time = 30 seconds; discharge current density = 1.75 amps/sq in.; system weight = 86 lbs (9.7 WH/lb); and system volume = 1071 cu. in. (.78 WH/cu. in.). EPI is currently working on a development program to produce a bipolar silver-zinc battery design for NASA. The potential application would be to power electromechanical actuators for space launch vehicles.

Giltner, L. John↗

Status of LBNF/DUNE near site liquid argon proximity and external cryogenics systems development.

The Deep Underground Neutrino Experiment (DUNE) near site located at Fermilab will host the neutrino beam complex. It includes a high voltage liquid argon time projection chamber located 60-meter underground used as beamline instrumentation. The LAr cryogenic system provided by the Long-Baseline Neutrino Facility (LBNF) regulates thermohydraulic conditions of the membrane cryostat hosting the detector with 285 Ton purified LAr. The purification system uses molecular sieve and copper oxide pellets to manage the argon contamination below 100 ppt (parts per trillion) oxygen equivalent. The detector and its cryogenics are capable to move a stroke of 30 meters on/off beam. The cryogenic system modes of operation include the cryostat pressure test, purge in open loop, detector cooldown, cryostat fill, closed loop purification, liquid empty, and purification system activation/regeneration process. The system design status and schedule, and technical details such as operating modes and interfaces are reported in this paper.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF SOLID-STATE DRIVERS FOR THE NIF PLASMA ELECTRODE POCKELS CELL

Large aperture Plasma Electrode Pockels Cells (PEPC) are an enabling technology in the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory. The Pockels cell allows the NIF laser to take advantage of multipass amplifier architecture, thus reducing costs and physical size of the facility. Each Pockels cell comprises four 40-cm x 40-cm apertures arranged in a 4 x 1 array. The combination of the Pockels cell and a thin-film polarizer, configured in a 4 x 1 array, form an optical switch that is key to achieving multi-pass operation. Solid-state Plasma Pulse Generators (PPGs) and high current high voltage solid-state Switch Pulse Generators (SPGs) have been developed for use in the PEPC. The solid-state plasma pulse generators initiate and maintain plasma within the cells; each pulser is capable of delivering 60J of energy to each plasma channel. Deployment of the solid-state PPGs has been completed in NIF. The MOSFET-switched SPG is capable of delivering a requisite fast rise time, 17kV flattop pulse to the cells nonlinear crystals. A complete software and hardware control system has been developed and is currently being tested for use on the solid-state SPGs. Also a transmission line modeling, development, and testing effort is in process, in support of NIFs Advanced Radiographic Capabilities (ARC). Work is scheduled for completion by the end of the calendar year.

42 ENGINEERING↗

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Beam test measurements with planar and 3D silicon strip detectors irradiated to sLHC fluences

The planned luminosity upgrade of the CERN LHC to the super LHC (sLHC) requires investigation of new radiation hard tracking detectors. Compared to the LHC, tracking detectors must withstand a 5-10 times higher radiation fluence. Promising radiation hard options are planar silicon detectors with n-side readout and silicon detectors in 3D technology, where columnar electrodes are etched into the silicon substrate. This article presents beam test measurements per formed with planar and 3D n-in-p silicon strip detectors. The detectors were irradiated to different fluences, where the maximum fluence was 3 x 10{sup 15} 1 MeV neutron equivalent particles per square centimeter (n{sub eq}/cm{sup 2}) for the planar detectors and 2 x 10{sup 15} n{sub eq}/cm{sup 2} for the 3D detectors. In addition to signal measurements, charge sharing and resolution of both detector technologies are compared. An increased signal from the irradiated 3D detectors at high bias voltages compared to the signal from the unirradiated detector indicates that charge multiplication effects occur in the 3D detectors. At a bias voltage of 260 V, the 3D detector irradiated to 2 x 10{sup 15} n{sub eq}/cm{sup 2} yields a signal almost twice as high as the signal of the unirradiated detector. Only 30% of the signal of an unirradiated detector could be measured with the planar detector irradiated to 3 x 10{sup 15} n{sub eq}/cm{sup 2} at a bias voltage of 600 V, which was the highest bias voltage applied to this sensor.

43 PARTICLE ACCELERATORS↗

Medium-Voltage Isolated Auxiliary Power Supply Design for High Insulation Capability, Ultra-Low Coupling Capacitance, and Small Size

To fully utilize the benefits of medium-voltage (MV) silicon carbide (SiC)-based converter and achieve high power density, the isolated auxiliary power supply (IAPS) needs to be as small as possible. However, the high insulation and low coupling capacitance requirements, considering the high voltage and high dv / dt , are constraints of size reduction. This article proposes an MV IAPS design for high insulation capability, ultra-low coupling capacitance, and small size. The topology selection, efficiency, load regulation, coupling capacitance, and size reduction considerations are discussed. A 2.5 W MV IAPS is designed and built for a 10 kV SiC mosfet -based 13.8 kV/100 kW three-phase converter, achieving a partial discharge (PD) inception voltage of higher than 15 kV rms, ultra-low coupling capacitance of 1.03 pF, and smaller size than that of the commercial products as well as the state-of-art research prototypes. Experimental results of PD test, 10 kV SiC mosfet -based half-bridge test, and 13.8 kV/100 kVA three-phase converter full rating test are conducted for design validation.

42 ENGINEERING↗

Field Emission Current Transfer for Homopolar Machines

With the increasing electrification of transportation, the need for high power density electric machines is higher than ever. The required specific power for the more demanding applications, such as airplane propulsion, is over 20 kW/kg for multi-megawatt range power levels. Fully superconducting synchronous machines could reach the required performance, but significant challenges remain to be addressed such as AC losses management and rotating cryogenics implementation. Homopolar machines constitute the simplest electro-mechanical conversion systems possible, however the difficulty of establishing reliable and efficient low voltage, high DC current transfer from a stationary to a rotating system has prevented homopolar machines from competing with AC electrical machines. While sliding contacts or liquid metal contacts are feasible, they lead to high losses, high maintenance requirements and the use of environmentally unfriendly materials. We investigated field emission current transfer as an alternative to sliding contacts. We have demonstrated field emission current transfer in vacuum between a copper electrode and carbon nanotubes and diamond pyramids to evaluate the feasibility of contact-free current transfer for homopolar machines. The initial field emission testing was successfully demonstrated with current densities in the 10 mA/cm 2 range. The initial experiments validated the concept and supported the development of a roadmap for the development of contactless current transfer for homopolar machines, helped understand the limitations of the current test system and identify the key parameters that will lead to better performance.

99 GENERAL AND MISCELLANEOUS↗

Sheath effects observed on a 10 meter high voltage panel in simulated low earth orbit plasma

A large (1m x 10m) flat surface of conductive material was biased to high voltage (+ or - 3000 V) to simulate the behavior of a large solar array in low earth orbit. The model array was operated in a plasma environment of 1,000 to 1,000,000/cu cm, with sufficient free space around it for the resulting plasma sheaths to develop unimpeded for 5-10 meters into the surrounding plasma. Measurements of the resulting sheath thickness were obtained. The observed thickness varied approximately as V to the 3/4 power and N to the 1/2 power. This effect appears to limit total current leakage from the test array until sheath dimensions exceed about 1 meter. Total leakage current was also measured with the array.

Mccox, J. E.↗

The characteristics and limitations of the MPS/MMS battery charging system

A series of tests was conducted on two 12 ampere hour nickel cadmium batteries under a simulated cycle regime using the multiple voltage versus temperature levels designed into the modular power system (MPS). These tests included: battery recharge as a function of voltage control level; temperature imbalance between two parallel batteries; a shorted or partially shorted cell in one of the two parallel batteries; impedance imbalance of one of the parallel battery circuits; and disabling and enabling one of the batteries from the bus at various charge and discharge states. The results demonstrate that the eight commandable voltage versus temperature levels designed into the MPS provide a very flexible system that not only can accommodate a wide range of normal power system operation, but also provides a high degree of flexibility in responding to abnormal operating conditions.

Ford, F. E.↗

Ion accelerator systems for high power 30 cm thruster operation

Two and three-grid accelerator systems for high power ion thruster operation were investigated. Two-grid translation tests show that over compensation of the 30 cm thruster SHAG grid set spacing the 30 cm thruster radial plasma density variation and by incorporating grid compensation only sufficient to maintain grid hole axial alignment, it is shown that beam current gains as large as 50% can be realized. Three-grid translation tests performed with a simulated 30 cm thruster discharge chamber show that substantial beamlet steering can be reliably affected by decelerator grid translation only, at net-to-total voltage ratios as low as 0.05.

Aston, G.↗

Miniature metastable ionization detectors for exobiology flight experiments

The Metastable Ionization Detector (MID) is three orders of magnitude more sensitive than the thermal conductivity detectors used on previous flight instruments. The miniature MID provides scientists with a much smaller and highly sensitive detector for flight gas chromatographs. A miniature MID featuring an unconventional triaxial electrode configuration was developed and used routinely in the laboratory. Although much smaller and lighter than the commercial MID, its performance characteristics parallel those of the traditional design. The detector is compatible with the modulated voltage circuitry, also developed here, and thus can perform over an expanded response range of more than 7 orders magnitude. A micro volume version of a miniature MID, with an internal volume of less than 8 microliter, was recently designed is now being tested. The micro volume MID uses carrier gas flow rates of approx. 2cc/min thus eliminating the need for makeup gas when capillary columns are used.

Woeller, F. H.↗

Stressed photoconductive detector for far-infrared space applications

An optimized leaf-spring apparatus for applying uniaxial stress to a Ge:Ga far-IR photoconductor has been designed and tested. This design has significant advantages for space applications which require high quantum efficiency and stable operation over long periods of time. The important features include adequate spring deflection with relatively small overall size, torque-free stress, easy measurement of applied stress, and a detector configuration with high responsivity. One-dimensional arrays of stressed photoconductors can be constructed using this design. A peak responsivity of 38 A/W is achieved in a detector with a cutoff wavelength of 200 microns, which was operated at a temperature of 2.0 K and a bias voltage equal to one-half of the breakdown voltage.

Wang, J.-Q.↗

Reverse bias voltage testing of 8 cm x 8cm silicon solar cells

A study is described of the reverse I-V characteristics of the largest space qualified silicon solar cells currently available (8 x 8 cm) and of reverse bias voltage (RBV) testing performed on these cells. This study includes production grade cells, both with and without cover glass. These cells span the typical output range seen in production. Initial characteristics of these cells are measured at both 28 and 60 C. These measurements show weak correlation between cell output and reverse characteristics. Analysis is presented to determine the proper conditions for RBV stress to simulate shadowing effects on a particular array design. After performing the RBV stress the characteristics of the stressed cells are remeasured. The degradation in cell performance is highly variable which exacerbates cell mismatching over time. The effect of this degradation on array lifetime is also discussed. Generalization of these results to other array configurations is also presented.

Woike, T.↗

Performance Test Results of the NASA-457M v2 Hall Thruster

Performance testing of a second generation, 50 kW-class Hall thruster labeled NASA-457M v2 was conducted at the NASA Glenn Research Center. This NASA-designed thruster is an excellent candidate for a solar electric propulsion system that supports human exploration missions. Thruster discharge power was varied from 5 to 50 kW over discharge voltage and current ranges of 200 to 500 V and 15 to 100 A, respectively. Anode efficiencies varied from 0.56 to 0.71. The peak efficiency was similar to that of other state-of-the-art high power Hall thrusters, but outperformed these thrusters at lower discharge voltages. The 0.05 to 0.18 higher anode efficiencies of this thruster compared to its predecessor were primarily due to which of two stable discharge modes the thruster was operated. One stable mode was at low magnetic field strengths, which produced high anode efficiencies, and the other at high magnetic fields where its predecessor was operated. Cathode keeper voltages were always within 2.1 to 6.2 V and cathode voltages were within 13 V of tank ground during high anode efficiency operation. However, during operation at high magnetic fields, cathode-to-ground voltage magnitudes increased dramatically, exceeding 30 V, due to the high axial magnetic field strengths in the immediate vicinity of the centrally-mounted cathode. The peak thrust was 2.3 N and this occurred at a total thruster input power of 50.0 kW at a 500 V discharge voltage. The thruster demonstrated a thrust-to-power range of 76.4 mN/kW at low power to 46.1 mN/kW at full power, and a specific impulse range of 1420 to 2740 s. For a discharge voltage of 300 V, where specific impulses would be about 2000 s, thrust efficiencies varied from 0.57 to 0.63.

Soulas, George C.↗

Assessments of Hollow Cathode Wear in the Xenon Ion Propulsion System (XIPs(c)) by Numerical Analyses and Wear Tests

The standard approach presently followed by NASA to qualify electric propulsion for the required mission throughput has been based largely on life tests, which can be costly and time consuming. Revised electric propulsion lifequalification approaches are being formulated that combine analytical and/or computational methods with (shorter-duration) wear tests. As a model case, a wear test is being performed at JPL to assess the lifetime of the discharge hollow cathode in the Xenon Ion Propulsion System (XIPS(c)), a 25-cm ion engine developed by L-3 Communications Electron Technologies, Inc. for commercial applications. Wear and plasma data accumulated throughout this life-assessment program are being used to validate the existing 2-D hollow cathode code OrCa2D. We find that the OrCa2D steady-state solution predicts very well the time-averaged plasma data and the keeper voltage after 5500 hrs of operation in high-power mode. When the wave motion that occurs naturally in these devices is accounted for, based on an estimate of the maximum wave amplitude, the molybdenum-keeper erosion profile observed in the XIPS(c) discharge cathode is also reproduced within a factor of two of the observation. When the same model is applied to predict the erosion of a tantalum keeper we find that erosion is reduced by more than two orders of magnitude compared to the molybdenum keeper due the significantly lower sputtering yield of tantalum. A tantalum keeper would therefore allow keeper lifetimes that greatly exceed the present requirements for deep-space robotic missions considered by NASA. Moreover, such large reduction of the erosion renders the largest uncertainties in the models, which are associated with the wave amplitude estimates and the electron transport model, negligible.

plasma simulations↗

Critical Contribution of Imbalanced Charge Loss to Performance Deterioration of Si-Based Lithium-Ion Cells during Calendar Aging

Increasing the energy density of lithium-ion batteries, and thereby reducing costs, is a major target for industry and academic research. One of the best opportunities is to replace the traditional graphite anode with a high-capacity anode material, such as silicon. However, Si-based lithium-ion batteries have been widely reported to suffer from a limited calendar life for automobile applications. Heretofore, there lacks a fundamental understanding of calendar aging for rationally developing mitigation strategies. Both open-circuit voltage and voltage-hold aging protocols were utilized to characterize the aging behavior of Si-based cells. Particularly, a high-precision leakage current measurement was applied to quantitatively measure the rate of parasitic reactions at the electrode/electrolyte interface. The rate of parasitic reactions at the Si anode was found 5 times and 15 times faster than those of LiNi 0.8 Mn 0.1 Co 0.1 O 2 and LiFePO 4 cathodes, respectively. Here, the imbalanced charge loss from parasitic reactions plays a critical role in exacerbating performance deterioration. In addition, a linear relationship between capacity loss and charge consumption from parasitic reactions provides fundamental support to assess calendar life through voltage-hold tests. These new findings imply that longer calendar life can be achieved by suppressing parasitic reactions at the Si anode to balance charge consumption during calendar aging.

25 ENERGY STORAGE↗

Refine your search to explore more results.