Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Graphene: a Barrier to Hydrogen Permeation

Small area freestanding monolayer graphene has been shown to be impermeable to standard gases including hydrogen and helium.1 Several recent reports have suggested that graphene can be used as a hydrogen permeation barrier on metals.2 Those studies have relied on electrochemical hydrogen permeation measurements, which do a good job reproducing bulk permeability compared to gaseous diffusion but do not always reflect the real surface effects due to the difference in driving forces. This problem is magnified when measuring the permeability of thin coatings, which are dominated by surface effects. For this reason, we performed gas driven hydrogen permeation measurements of graphene coated metal samples. The diffusion of hydrogen through a metal can be described using Fick's and Sievert's Laws. Graphene-coated copper foils were prepared using chemical vapor deposition (CVD) with a methane precursor. Photo-reduced graphene samples were prepared by first sputtering a layer (∼15 nm) of copper on top of stainless steel foils. Graphene oxide in ethanol solutions were then drop cast on the surface and photo reduced using a neon lamp. A custom-designed apparatus has been assembled for measuring the hydrogen permeability of various materials. The operating principle of the system is as follows: A sample is sealed between the fore-sample and post-sample chambers using standard vacuum gaskets. Hydrogen is introduced into the fore sample region at varying pressures while the post sample region is maintained under high vacuum. Due to the concentration gradient, hydrogen then diffuses through the material and is detected using a quadrupole mass spectrometer. This process is repeated at several temperatures. The mass spectrometer was calibrated using an orifice with known conductance in place of the sample. Data collection and reduction were automated using scripts written in LabVIEW and Octave, respectively. We saw a decrease in the hydrogen permeability of copper after adding graphene to the surface for small temperature steps. This result is also observed when considering temperature steps of 20 K. Future Work: Apply this methodology to graphene-coated 316L stainless steel. The hydrogen permeability of 316L steel should also decrease with the addition of graphene to the surface. Determine methods for graphene defect reduction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of a large density gradient on linear and nonlinear edge-localized mode simulations

Here, the impact of a large density gradient on edge-localized modes (ELMs) is studied linearly and nonlinearly by employing both two-fluid and gyro-fluid simulations. In two-fluid simulations, the ion diamagnetic stabilization on high-n modes disappears when the large density gradient is taken into account. But gyro-fluid simulations show that the finite Larmor radius (FLR) effect can effectively stabilize high-n modes, so the ion diamagnetic effect alone is not sufficient to represent the FLR stabilizing effect. We further demonstrate that additional gyroviscous terms must be kept in the two-fluid model to recover the linear results from the gyro-fluid model. Nonlinear simulations show that the density variation significantly weakens the E × B shearing at the top of the pedestal and thus leads to more energy loss during ELMs. The turbulence spectrum after an ELM crash is measured and has the relation of $P(k_{z})\propto k_{z}^{-3.3}$ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High spatial resolution temperature profile measurements of solid-oxide fuel cells

Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.

25 ENERGY STORAGE↗

Inherent Driving Force for Charge Separation in Curved Stacks of Oligothiophenes

Coexistence of high local charge mobility and an energy gradient can lead to efficient free charge carrier generation from geminate charge transfer states at the donor–acceptor interface in bulk heterojunction organic photovoltaics. It is, however, not clear what polymer microstructures can support such coexistence. Using recent methods from density functional theory, we propose that a stack of similarly curved oligothiophene chains can deliver the requirements for efficient charge separation. Curved stacks are stable because of the polymer’s strong π-stacking ability and because backbone torsions are flexible in neutral chains. However, energy of a charge in a polymer chain has remarkably stronger dependence on torsions. The trend of increasing planarity in curved stacks effectively creates an energy gradient that drives charge in one direction. The curvature of these partially ordered stacks is found to beneficially interact with fullerenes for charge separation. The curved stacks, therefore, are identified as possible building blocks for interfacial structures that lead to efficient free carrier generation in high-performing organic photovoltaic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Least squares inversion of Stokes profiles in the presence of velocity gradients

The Auer, Heasley and House Stokes inversion procedure in use at High Altitude Observatory is based on the analytic solution of the equation of transfer for polarized light where the representation of the thermodynamic and magnetic structure of the atmosphere is assumed to have a high degree of invariance, namely, a Milne-Eddington (ME) structure with a constant magnetic field. In the presence of invariance breaking gradients the resultant Stokes profiles are represented only approximately, if at all, by analytic forms. The accuracy of the inversion parameters and their significance as measures of actual structure are explored for the ME and the Landman-Finn sunspot models under the effects of velocity gradients. The resulting field parameters are good to a few percent and prove to be insensitive to the errors committed by the use of a ME-representation, but the resulting ME parameters yield a less precise measure of thermal structure.

Skumanich, A.↗

Cause and Cure - Deterioration in Accuracy of CFD Simulations with Use of High-Aspect-Ratio Triangular/Tetrahedral Grids

Traditionally high-aspect ratio triangular/tetrahedral meshes are avoided by CFD researchers in the vicinity of a solid wall, as it is known to reduce the accuracy of gradient computations in those regions. Although for certain complex geometries, the use of high-aspect ratio triangular/tetrahedral elements in the vicinity of a solid wall can be replaced by quadrilateral/prismatic elements, ability to use triangular/tetrahedral elements in such regions without any degradation in accuracy can be beneficial from a mesh generation point of view. The benefits also carry over to numerical frameworks such as the space-time conservation element and solution element (CESE), where simplex elements are the mandatory building blocks. With the requirement of the CESE method in mind, a rigorous mathematical framework that clearly identifies the reason behind the difficulties in use of such high-aspect ratio simplex elements is formulated using two different approaches and presented here. Drawing insights from the analysis, a potential solution to avoid that pitfall is also provided as part of this work. Furthermore, through the use of numerical simulations of practical viscous problems involving high-Reynolds number flows, how the gradient evaluation procedures of the CESE framework can be effectively used to produce accurate and stable results on such high-aspect ratio simplex meshes is also showcased.

CESE Method↗

The impact of SST resolution change in the ERA-Interim reanalysis on wintertime Gulf Stream frontal air-sea interaction: SST Resolution Change in ERA-Interim

This paper examines the sensitivity to a change in sea surface temperature (SST) resolution of the interaction between atmospheric and oceanic fronts in the Gulf Stream region in the ERA-Interim reanalysis data set. Two periods are considered, January 1979 to December 2001 (SST resolution 1° × 1°) and December 2010 to February 2016 (SST resolution 0.05° × 0.05°). The winter season from the latter 6 years of high-resolution SST is compared against six random periods of six wintertime seasons from the low-resolution SST period, to assess the robustness of the result against natural climate variability. In all comparisons, a significant change in frontal air-sea sensible heat flux exchange is found that is highly correlated to the change in mean SST gradient. This leads to both increases and decreases in occurrence of atmospheric fronts and mean precipitation of up to 30%. These results reemphasize the importance of high SST resolution in resolving the influence of oceanic fronts on weather and climate.

54 ENVIRONMENTAL SCIENCES↗

Variable location channels to improve efficiency and precision for direct ∇ T e measurements and high spatial resolution T e -profile measurements using electron cyclotron emission

Electron cyclotron emission (ECE) diagnostics that use variable location channels based on yttrium iron garnet (YIG) bandpass filters improve the precision and the efficiency of measurements of electron temperature (T e ) profiles and fluctuations (δT e ). These variable frequency filters were substituted for fixed frequency filters in the intermediate frequency section to achieve the required higher resolution over a target radial range, just before the experiment. In this paper, we present the proof-of-principle for high temporal resolution measurement of the electron temperature gradient, via real-time slewing of a YIG filter for relocation of an ECE channel during a long pulse. The key component is the application of YIG tunable filters with their narrow bandwidth and capability for a high slew rate of their center frequency. This application permits fast relocation of the ECE channels for direct measurement of the gradient and close spacing of channels to investigate the magnetic island’s dynamic behavior.

47 OTHER INSTRUMENTATION↗

The latitudinal gradient of nitric oxide in the thermosphere

Theoretical calculations of nitric oxide altitude profiles are made at five different latitudes by using neutral temperatures and composition primarily from the MSIS (mass spectrometer and incoherent scatter) model. The nitric oxide calculated for an altitude of 105 km remains nearly constant with increasing latitude. Observations made by the ultraviolet nitric oxide instrument on the Atmosphere Explorer C satellite show that at low magnetic activity (Ap value of approximately 4), the NO density at 105 km agrees with the theory; however, at moderate levels of activity it increases with latitude. This discrepancy between the theoretical and observed latitudinal gradients of nitric oxide suggests the transport of NO from a high latitude source to lower latitudes. At 200 km the theoretical and observed latitudinal gradients are in reasonable agreement, an indication that the knowledge of the local composition and temperature is sufficient to model nitric oxide at this altitude.

Cravens, T. E.↗

Optimizing the resolution of the alternating-gradient m/{mu} selector

We study the focusing of large neutral molecules in a molecular beam using electric fields. Since all quantum states of these molecules are high-field seeking under the practical experimental conditions, alternating gradient (AG) focusing has to be applied. The optimal ac frequency that yields the highest transmission depends on m/{mu}, where {mu} is the dipole moment and m denotes the mass. Therefore, an AG focuser can be used to select species with different m/{mu} ratios, e.g., the conformers of neutral molecules [Phys. Rev. Lett. 100, 133003 (2008)]. Here we demonstrate both theoretically and experimentally how the resolution of such an m/{mu} selector can be optimized.

74 ATOMIC AND MOLECULAR PHYSICS↗

A superior combination of strength-ductility in CoCrFeNiMn high-entropy alloy induced by asymmetric rolling and subsequent annealing treatment

Highlights: • Asymmetric rolling was carried out to process bulk single face-centered-cubic (FCC) CoCrFeMnNi HEA. • A gradient microstructure and smaller average grain size was obtained through Asymmetric rolling and annealing process. • The processed alloys after Asymmetric rolling exhibits a superior combination of the high strength and good ductility. - Abstract: CoCrFeMnNi high-entropy alloy with a smaller average grain size and gradient microstructure was produced by asymmetric rolling (ASR) and subsequent annealing treatment, which gave rise to a superior combination of strength-ductility. High back stress, working hardening and geometrically necessary dislocations were detected in the gradient structure. The ultra-high strength of the CoCrFeMnNi high-entropy alloy was related to the fine grain and high back-stress, while the superior ductility was ascribed to the gradient structure and fine grain. ASR followed by annealing might be a novel strategy for designing high entropy alloys with high performance.

36 MATERIALS SCIENCE↗

Absence of Barren Plateaus and Scaling of Gradients in the Energy Optimization of Isometric Tensor Network States

Abstract Vanishing gradients can pose substantial obstacles for high-dimensional optimization problems. Here we consider energy minimization problems for quantum many-body systems with extensive Hamiltonians and finite-range interactions, which can be studied on classical computers or in the form of variational quantum eigensolvers on quantum computers. Barren plateaus correspond to scenarios where the average amplitude of the energy gradient decreases exponentially with increasing system size. This occurs, for example, for quantum neural networks and for brickwall quantum circuits when the depth increases polynomially in the system size. Here we prove that the variational optimization problems for matrix product states, tree tensor networks, and the multiscale entanglement renormalization ansatz are free of barren plateaus. The derived scaling properties for the gradient variance provide an analytical guarantee for the trainability of randomly initialized tensor network states (TNS) and motivate certain initialization schemes. In a suitable representation, unitary tensors that parametrize the TNS are sampled according to the uniform Haar measure. We employ a Riemannian formulation of the gradient based optimizations which simplifies the analytical evaluation.

Barthel, Thomas↗

On the exceptional damage-tolerance of gradient metallic materials

An experimental study is described on the fracture toughness and micro-mechanisms associated with the initiation and propagation of cracks in metallic nickel containing marked gradients in grain size, ranging from ~30 nm to ~4 μm. Specifically, cracks are grown in a gradient structured (GS) nickel with grain-size gradient ranging from the coarse macro-scale to nano-scale (CG → NG) and vice versa (NG → CG), with the measured crack-resistance R-curves compared to the corresponding behavior in uniform nano-grained (NG) and coarse-grained (CG) materials. It is found that the gradient structures display a much-improved combination of high strength and toughness compared to uniform grain-sized materials. However, based on J-integral measurements in the gradient materials, the crack-initiation toughness is far higher for cracks grown in the direction of the coarse-to-nano grained gradient than vice versa, a result which we ascribe primarily to excessive crack-tip blunting in the coarse-grained microstructure. Both gradient structures, however, display marked rising R-curve behavior with exceptional crack-growth toughnesses exceeding 200 MPa.m ½ .

36 MATERIALS SCIENCE↗

Computational and Experimental Flow Field Analyses of Separate Flow Chevron Nozzles and Pylon Interaction

A computational and experimental flow field analyses of separate flow chevron nozzles is presented. The goal of this study is to identify important flow physics and modeling issues required to provide highly accurate flow field data which will later serve as input to the Jet3D acoustic prediction code. Four configurations are considered: a baseline round nozzle with and without a pylon, and a chevron core nozzle with and without a pylon. The flow is simulated by solving the asymptotically steady, compressible, Reynolds-averaged Navier-Stokes equations using an implicit, up-wind, flux-difference splitting finite volume scheme and standard two-equation kappa-epsilon turbulence model with a linear stress representation and the addition of a eddy viscosity dependence on total temperature gradient normalized by local turbulence length scale. The current CFD results are seen to be in excellent agreement with Jet Noise Lab data and show great improvement over previous computations which did not compensate for enhanced mixing due to high temperature gradients.

Massey, Steven J.↗

Concurrent Monte Carlo transport and fluence optimization with fluence adjusting scalable transport Monte Carlo

Purpose: The future of radiation therapy will require advanced inverse planning solutions to support single-arc, multiple-arc, and “4π” delivery modes, which present unique challenges in finding an optimal treatment plan over a vast search space, while still preserving dosimetric accuracy. The successful clinical implementation of such methods would benefit from Monte Carlo (MC) based dose calculation methods, which can offer improvements in dosimetric accuracy when compared to deterministic methods. The standard method for MC based treatment planning optimization leverages the accuracy of the MC dose calculation and efficiency of well-developed optimization methods, by precalculating the fluence to dose relationship within a patient with MC methods and subsequently optimizing the fluence weights. However, the sequential nature of this implementation is computationally time consuming and memory intensive. Methods to reduce the overhead of the MC precalculation have been explored in the past, demonstrating promising reductions of computational time overhead, but with limited impact on the memory overhead due to the sequential nature of the dose calculation and fluence optimization. The authors propose an entirely new form of “concurrent” Monte Carlo treat plan optimization: a platform which optimizes the fluence during the dose calculation, reduces wasted computation time being spent on beamlets that weakly contribute to the final dose distribution, and requires only a low memory footprint to function. In this initial investigation, the authors explore the key theoretical and practical considerations of optimizing fluence in such a manner. Methods: The authors present a novel derivation and implementation of a gradient descent algorithm that allows for optimization during MC particle transport, based on highly stochastic information generated through particle transport of very few histories. A gradient rescaling and renormalization algorithm, and the concept of momentum from stochastic gradient descent were used to address obstacles unique to performing gradient descent fluence optimization during MC particle transport. The authors have applied their method to two simple geometrical phantoms, and one clinical patient geometry to examine the capability of this platform to generate conformal plans as well as assess its computational scaling and efficiency, respectively. Results: The authors obtain a reduction of at least 50% in total histories transported in their investigation compared to a theoretical unweighted beamlet calculation and subsequent fluence optimization method, and observe a roughly fixed optimization time overhead consisting of ∼10% of the total computation time in all cases. Finally, the authors demonstrate a negligible increase in memory overhead of ∼7–8 MB to allow for optimization of a clinical patient geometry surrounded by 36 beams using their platform. Conclusions: This study demonstrates a fluence optimization approach, which could significantly improve the development of next generation radiation therapy solutions while incurring minimal additional computational overhead.

60 APPLIED LIFE SCIENCES↗

High spatial resolution Raman thermometry analysis of TiO 2 microparticles

A new technique of high-resolution micro-Raman thermometry using anatase TiO2microparticles (0.5-3 μm) is presented. These very high spatial resolution measurements (280 nm) reveal temperature gradients even within individual microparticles. Potential applications of this technique are demonstrated by probing the temperature distribution of a micro-fabricated heater consisting of a thin silicon nitride (Si-N) membrane with a gold coil on top of the membrane. Using TiO 2 microparticle micro-Raman thermometry, the temperature from the outer edge of the coil to the inner portion was measured to increase by ∼40 °C. These high spatial resolution microscopic measurements were also used to measure the temperature gradient within the 20 μm wide Si-N between the gold heating coils. 2D numerical simulations of the micro heater temperature distribution are in excellent agreement with the experimental measurements of the temperatures. These measurements illustrate the potential to extend applications of micro-Raman thermometry to obtain temperature details on a sub-micrometer spatial resolution by employing microparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse

Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse is analyzed within the kinetic approach. It is shown that the most efficient source of plasma waves is the nonlinear current arising due to the gradient of the energy density of the high-frequency field. Generation of plasma waves by the drag current is usually less efficient but not negligibly small at relatively high frequencies of electron–ion collisions. The influence of electron collisions on the excitation of plasma waves by pulses of different duration is described quantitatively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refine your search to explore more results.