Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Fiber-Based Distributed Hydrogen Measurement at High Temperatures

In this work, we discuss the implementation of evanescent field optical fiber sensors for distributed gas sensing of H2, focusing on results using a Ni / Gd-doped CeO2 nanocomposite sensing material for detection of low levels of H2 (0-4%) at 700 °C. This approach utilizes sensors prepared using a low-cost, wet chemical deposition process, in conjunction with a custom-built interrogator system leveraging optical time domain reflectometry (OTDR). Using a specially designed dual-gas flow reactor system, the sensor is tested by establishing a controlled equilibrium gradient of gas concentration. Initial results are shown using silica fiber, but provides a pathway for utilization with high temperature stable single crystal optical fiber for operation at higher temperatures and higher levels of H2 relevant for solid oxide fuel cell (SOFC) operating conditions.

Wuenschell, Jeffrey↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters Christopher A. Zarzana1, Makayla R. Baxter , Introduction: Molecular hydrogen is a potential energy carrier that could be used to help implement a clean energy economy if it is generated from splitting of water. Improvements in the efficiencies of water-splitting electrolyzers relies on development of novel materials with enhanced performance. However, research in this area is slowed due to underdeveloped understanding of the mechanisms of device performance due to challenges interrogating the fundamental chemical reactions at play in bulk materials. Studies of the intrinsic reactivity of clusters that are representative of the reactive sites of these materials can increase understanding of the fundamental reaction mechanisms involved in hydrogen production, allowing for more efficient development of new water-splitting materials. Methods: Holmium tetranitrato ([Ho(NO3)4]-) clusters were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Spray solutions consisted of aqueous holmium (Ho) nitrate solutions (at nominally 3 mM) diluted to 30 µM in acetonitrile. The holmium (Ho) tetranitrato clusters were isolated using the quadrupole and were subsequently activated and allowed to react with background water in the collision cell. High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data: Collisional activation of the holmium tetranitrato complexes ([Ln(NO3)4]-) resulted in an expected series of ions resulting from the loss of ·NO and ·NO2. This included an ion at m/z = 382.885 assigned as [HoO2(NO3)3]- (theoretical m/z=382.884, error=-1.2 ppm), resulting from loss of ·NO, and an ion at m/z=366.890 assigned as [HoO(NO3)3]- (theorical m/z=366.889, error=-1.8 ppm), resulting from loss of ·NO2. Additional ions were detected that would result from more complicated losses from [Ho(NO3)4]-, including ions at m/z=320.898 assigned as [HoO2(NO3)2]- (theoretical m/z=320.896, error=-4.9 ppm), at m/z=304.904 assigned as [HoO(NO3)2]- (theoretical m/z=304.901, error=-8.1 ppm, very low signal), and at m/z=288.908 assigned as [Ho(NO3)2]- (theoretical m/z=288.907, error=-3.4 ppm). This ion series would arise from loss of some combination of ·NO, ·NO2, and ·NO3, although it is not known whether these losses occur sequentially (e.g. loss of ·NO and ·NO3 to yield [HoO2(NO3)2]-) or as a single species (e.g. direct loss of N2O4). These ions were accompanied by a complementary series representing addition of a single water molecule. This included an ion at m/z=338.908 assigned as [HoO2(NO3)2H2O]- (theoretical m/z=338.907, error=-4.1 ppm), an ion at m/z=322.912 assigned as [HoO(NO3)2H2O]- (theoretical m/z=322.912, error=1.2 ppm), and an ion at m/z=306.918 assigned as [Ho(NO3)2H2O]-, (theoretical m/z=306.918, error=-3.7 ppm). An additional hydrated ion was observed at m/z=276.921 assigned as [HoO2(NO3) H2O]- (theoretical m/z=276.919, error=-7.3 ppm), although corresponding dehydrated ion was not observed. An additional ion was observed at m/z=367.898 that has been assigned as [Ho(NO3)3OH]- (theoretical m/z=367.897, error=-2.5 ppm). It is hypothesized that this ion arises from addition of water to [Ho(NO3)3]- followed by elimination of a hydrogen radical. Neither [Ho(NO3)3]- nor [Ho(NO3)3H2O]- were detected, suggesting that, if the hypothesis is correct, addition of water to [Ho(NO3)3]- and its subsequent splitting is rapid. Elimination of HNO3 from [Ho(NO3)4H2O]- could also yield [Ho(NO3)3OH]-; however, no [Ho(NO3)4H2O]- ions were observed. Novelty: Potential evidence of water splitting on gas-phase lanthanide clusters offers a way to study the intrinsic reactivity of hydrogen-generation materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Optical sensing of magnetic fields using magnetically sensitive materials

The invention provides a method for measuring the magnetic field of an electromagnetic component having the steps of: instrumenting one or more portions of an electromagnetic component by placing an optical fiber in electromagnetic communication with the one or more portions of said electromagnetic component; energizing the electromagnetic component; interrogating the optical fiber using light and an optical detector; and determining changes in the magnetic field incident on the optical fiber based on the detected changes in the light received by the optical detector.

Ohodnicki, Paul↗

Systems, methods, and devices for failure detection of one or more energy storage devices

An energy storage device management system can include a management portion for charging/discharging an energy storage device and an ultrasound interrogation portion for passing ultrasound energy through the energy storage device during charge/discharge cycles. A memory stores a stream of capture data instances derived from ultrasound energy exiting the energy storage device and baseline ultrasound data instances corresponding with the energy storage device during normal charging/discharging thereof. A processor can compare each capture data instance with the baseline ultrasound data and detect abnormal operating states of the energy storage device. A warning system can issue a notification when abnormal operating states are detected.

Kowalski, Jeffrey A.↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of Ensuring the safety, integrity, and operational efficiency of underground product pipelines is vital for maintaining the nation’s critical infrastructure. Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensors—were employed to measure key parameters like hoop strain, pressure, and acoustic vibrations. The underground product pipeline's outer diameter is 30 inches, the wall thickness is 1.28 inches, and the 3-foot depth. The fiber deployment strategies, and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety.

distributed fiber sensing↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗

Integrated optical biosensor system (IOBS)

An optical biosensor has a first enclosure with a pathogen recognition surface, including a planar optical waveguide and grating located in the first enclosure. An aperture is in the first enclosure for insertion of sample to be investigated to a position in close proximity to the pathogen recognition surface. A laser in the first enclosure includes means for aligning and means for modulating the laser, the laser having its light output directed toward said grating. Detection means are located in the first enclosure and in optical communication with the pathogen recognition surface for detecting pathogens after interrogation by the laser light and outputting the detection. Electronic means is located in the first enclosure and receives the detection for processing the detection and outputting information on the detection, and an electrical power supply is located in the first enclosure for supplying power to the laser, the detection means and the electronic means.

47 OTHER INSTRUMENTATION↗

Thermal neutron imaging support with other laboratories BL06-IM-TNI

The goals of this project are: (1) detect and locate a source of thermal neutrons; (2) distinguish a localized source from uniform background; (3) show shape and size of thermalizing material; (4) test thermal neutron imager in active interrogation environment; and (5) distinguish delayed neutrons from prompt neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of a concealed object

Disclosed are systems, methods, devices, and apparatus to determine if a clothed individual is carrying a suspicious, concealed object. This determination includes establishing data corresponding to an image of the individual through interrogation with electromagnetic radiation in the 200 MHz to 1 THz range. In one form, image data corresponding to intensity of reflected radiation and differential depth of the reflecting surface is received and processed to detect the suspicious, concealed object.

47 OTHER INSTRUMENTATION↗

System and technique for characterizing fluids using ultrasonic diffraction grating spectroscopy

A system for determining property of multiphase fluids based on ultrasonic diffraction grating spectroscopy includes a diffraction grating on a solid in contact with the fluid. An interrogation device delivers ultrasound through the solid and a captures a reflection spectrum from the diffraction grating. The reflection spectrum exhibits peaks whose relative size depends on the properties of the various phases of the multiphase fluid. For example, for particles in a liquid, the peaks exhibit dependence on the particle size and the particle volume fraction. Where the exact relationship is know know a priori, data from different peaks of the same reflection spectrum or data from the peaks of different spectra obtained from different diffraction gratings can be used to resolve the size and volume fraction.

47 OTHER INSTRUMENTATION↗

Nuclear Resonance Fluorescence Measurements of High Explosives

Pacific Northwest National Laboratory and Passport Systems have collaborated to perform Nuclear Resonance Fluorescence experiments using several high quality high-explosive simulant samples. These measurements were conducted to determine the feasibility of finding and characterizing high explosive material by NRF interrogation. Electron beams of 5.1, 5.3, 8, and 10 MeV were used to produce bremsstrahlung photon beams, which irradiated the samples. The gamma-ray spectra were collected using high-purity germanium detectors. Nitrogen-to-carbon ratios of the high-explosive simulants were extracted from the 5.1 and 5.3 MeV data and compare favorably with accepted values. Analysis of the 8 and 10 MeV data is in progress; preliminary isotopic comparisons within the samples are consistent with the expected results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and reduction of chemical models under uncertainty.

While models of combustion processes have been successful in developing engines with improved fuel economy, more costly simulations are required to accurately model pollution chemistry. These simulations will also involve significant parametric uncertainties. Computational singular perturbation (CSP) and polynomial chaos-uncertainty quantification (PC-UQ) can be used to mitigate the additional computational cost of modeling combustion with uncertain parameters. PC-UQ was used to interrogate and analyze the Davis-Skodje model, where the deterministic parameter in the model was replaced with an uncertain parameter. In addition, PC-UQ was combined with CSP to explore how model reduction could be combined with uncertainty quantification to understand how reduced models are affected by parametric uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Label-free separation of human embryonic stem cells (hESCs) and their cardiac derivatives using Raman spectroscopy

Self-renewable, pluripotent human embryonic stem cells (hESCs) can be differentiated into cardiomyocytes (CMs), providing an unlimited source of cells for transplantation therapies. However, unlike certain cell lineages such as hematopoietic cells, CMs lack specific surface markers for convenient identification, physical separation, and enrichment. Identification by immunostaining of cardiac-specific proteins such as troponin requires permeabilization, which renders the cells unviable and non-recoverable. Ectopic expression of a reporter protein under the transcriptional control of a heart-specific promoter for identifying hESC-derived CMs (hESC-CMs) is useful for research but complicates potential clinical applications. The practical detection and removal of undifferentiated hESCs in a graft, which may lead to tumors, is also critical. Here, we demonstrate a non-destructive, label-free optical method based on Raman scattering to interrogate the intrinsic biochemical signatures of individual hESCs and their cardiac derivatives, allowing cells to be identified and classified. By combining the Raman spectroscopic data with multivariate statistical analysis, our results indicate that hESCs, human fetal left ventricular CMs, and hESC-CMs can be identified by their intrinsic biochemical characteristics with an accuracy of 96%, 98% and 66%, respectively. The present study lays the groundwork for developing a systematic and automated method for the non-invasive and label-free sorting of (i) high-quality hESCs for expansion, and (ii) ex vivo CMs (derived from embryonic or adult stem cells) for cell-based heart therapies.

42 ENGINEERING↗

Bremstrahlung versus Monoenergetic Photons for Photonuclear Inspection Applications

Bremsstrahlung sources have been utilized for various non-intrusive inspection or interrogation applications for over 100 years - with the primary focus being radiographic imaging. In the last several decades, it has become evident that photons of energy greater than 6 MeV can also provide useful photonuclear information that can extend the capabilities and information available from active inspections. These energetic inspection photons can be produced as a continuum of energies (i.e., bremsstrahlung distribution) or as a set of one or more discrete photon energies (i.e., monoenergetic distribution). This paper will discuss the photonuclear process and its energetic photon energy dependence, will discuss the photonuclear role in nuclear material detection, will present applicable photon sources along with their field deployment status, and highlight some advantages and disadvantages of bremsstrahlung and monoenergetic photons sources.

99 GENERAL AND MISCELLANEOUS↗

Molecular models and simulations of layered materials.

The micro- to nano-sized nature of layered materials, particularly characteristic of naturally occurring clay minerals, limits our ability to fully interrogate their atomic dispositions and crystal structures. The low symmetry, multicomponent compositions, defects, and disorder phenomena of clays and related phases necessitate the use of molecular models and modern simulation methods. Computational chemistry tools based on classical force fields and quantum-chemical methods of electronic structure calculations provide a practical approach to evaluate structure and dynamics of the materials on an atomic scale. Combined with classical energy minimization, molecular dynamics, and Monte Carlo techniques, quantum methods provide accurate models of layered materials such as clay minerals, layered double hydroxides, and clay-polymer nanocomposites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refine your search to explore more results.