Search NASA⌕ Search

SEARCH · Search NASA

Results for “Intersection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Removal of River-Stage Fluctuations from Well Response Using Multiple-Regression

Many contaminated unconfined aquifers are located in proximity to river systems. In groundwater studies, the physical presence of a river is commonly represented as a transient-head boundary that imposes hydrologic responses within the intersected unconfined aquifer. The periodic fluctuation of river-stage height at the boundary produces associated responses within the adjacent aquifer system, the magnitude of which is a function of the existing well, aquifer, boundary conditions, and river-stage fluctuation characteristics. The presence of well responses induced by the river stage can significantly limit characterization and monitoring of remedial activities within the stress-impacted area. This paper demonstrates the use of a time-domain, multiple-regression, convolution (superposition) method to develop well/aquifer river response function (RRF) relationships. Following RRF development, a multiple-regression deconvolution correction approach can be applied to remove river-stage effects from well water-level responses. Corrected well responses can then be analyzed to improve local aquifer characterization activities in support of optimizing remedial actions, assessing the area-of-influence of remediation activities, and determining mean groundwater flow and contaminant flux to the river system.

54 ENVIRONMENTAL SCIENCES↗

Linking plant hydraulics and beta diversity in tropical forests

In tropical forests, studies of xylem traits governing water transport through plants, or ‘hydraulic architecture’ (Tyree et al., 1991), and changes in species composition across environmental gradients, or ‘beta diversity’ (Gentry, 1988; Ackerly & Cornwell, 2007), have progressedmostly in parallel until recently (Hao et al., 2008; Bartlett et al., 2016). In this issue of New Phytologist, Cosme et al. (pp. 000–5 000) present a timely contribution to the intersection of plant hydraulic architecture (HA) with trait-based community ecology. Building on previous biogeographical work that demonstrated shifts in species composition (beta diversity) across a gradient from valleys to plateaus in central Amazonia (Schietti et al., 2014), Cosme et al. explore how variation in HA might underpin this sorting, sampling pairs of congeneric species restrictedmostly to either plateau or valley habitats. Valley species had significantly lower wood density and higher hydraulically-weighted vessel diameter and vessel area. By contrast, trees with some of the largest hydraulically-weighted vessel diameters existed in tall, deciduous plateau species, while the leaf: sapwood area ratio decreased with height in valley but not plateau species. These intriguing results suggest that species differentiation in water transport traits mediate edaphic filtering along the valley-toplateau gradient, in contrast to previous work where wood mechanical support mediated valley-to-plateau environmental filtering (Fortunel et al., 2014).

Christoffersen, Bradley↗

Let’s talk about sex: A biological variable in immune response against melanoma

As science culture gravitates toward a more holistic inclusion of both males and females in research design, the outlining of sex differences and their respective intersections with disease physiology and pathophysiology should see reciprocal expansion. Melanoma skin cancer, for example, has observed a female advantage in incidence, mortality, and overall survival since the early 1970s. The exact biological mechanism of this trend, however, is unclear and further complicated by a layering of clinical variables such as skin phototype, age, and body mass index. In this perspective, we highlight epidemiological evidence of sex differences in melanoma and summarize the landscape of their potential origin. Among several biological hallmarks, we make a note of sex-specific immune profiles—along with divergent hormonal regulation, social practices, DNA damage and oxidative stress responses, body composition, genetic variants, and X-chromosome expression—as probable drivers of disparity in melanoma initiation and progression. This review further focuses the conversation of sex as an influencing factor in melanoma development and its potential implication for disease management and treatment strategies.

59 BASIC BIOLOGICAL SCIENCES↗

A Multirange Vehicle Speed Prediction With Application to Model Predictive Control-Based Integrated Power and Thermal Management of Connected Hybrid Electric Vehicles

Abstract Connectivity and automated driving technologies have opened up new research directions in the energy management of vehicles which exploit look-ahead preview and enhance the situational awareness. Despite this advancement, the vehicle speed preview that can be obtained from vehicle-to-vehicle/infrastructure (V2V/I) communications is often limited to a relatively short time-horizon. The vehicular energy systems, specifically those of the electrified vehicles, consist of multiple interacting power and thermal subsystems that respond over different time-scales. Consequently, their optimal energy management can greatly benefit from long-term speed prediction beyond that available through V2V/I communications. Accurately extending the look-ahead preview, on the other hand, is fundamentally challenging due to the dynamic nature of the traffic environment. To address this challenge, we propose a data-driven multirange vehicle speed prediction strategy for arterial corridors with signalized intersections, providing the vehicle speed preview for three different ranges, i.e., short-, medium-, and long-range. The short-range preview is obtained by V2V/I communications. The medium-range preview is realized using a neural network (NN), while the long-range preview is predicted based on a Bayesian network (BN). The predictions are updated in real-time based on the current state of traffic and incorporated into a multihorizon model predictive control (MH-MPC) for integrated power and thermal management (iPTM) of connected vehicles. The results of design and evaluation of the performance of the proposed data-informed MH-MPC for iPTM of connected hybrid electric vehicles (HEVs) using traffic data for real-world city driving are reported.

Automation & Control Systems↗

Ecological Adaptive Cruise Control of Plug-In Hybrid Electric Vehicle With Connected Infrastructure and On-Road Experiments

Abstract This paper examines both mathematical formulation and practical implementation of an ecological adaptive cruise controller (ECO-ACC) with connected infrastructure. Human errors are typical sources of accidents in urban driving, which can be remedied by rigorous control theories. Designing an ECO-ACC is, therefore, a classical research problem to improve safety and energy efficiency. We add two main contributions to the literature. First, we propose a mathematical framework of an online ECO-ACC for plug-in hybrid electric vehicle (PHEV). Second, we demonstrate ECO-ACC in a real world, which includes other human drivers and uncertain traffic signals on a 2.6 (km) length of the corridor with eight signalized intersections in Southern California. The demonstration results show, on average, 30.98% of energy efficiency improvement and 8.51% additional travel time.

Automation & Control Systems↗

Instrumentation to Monitor Transient Periodic Developing Flow in Non-Newtonian Slurries

Staff at Pacific Northwest National Laboratory have conducted mixing and mobilization experiments with non-Newtonian slurries that exhibit Bingham plastic and shear thinning behavior and shear strength. This paper describes measurement techniques applied to identify the interface between flowing and stationary regions of non-Newtonian slurries that are subjected to transient, periodic, developing flows. Techniques were developed to identify the boundary between the flowing and stationary regions, time to mix, characteristic velocities of the flow field produced by the symmetrically spaced nozzles, and the velocity of the upwell formed in the center of the tank by the intersection of flow from four symmetrically spaced nozzles that impinge upon the tank floor. Descriptions of the instruments and instrument performance are presented. These techniques were an effective approach to characterize mixing phenomena, determine mixing energy required to fully mobilize vessel contents and to determine mixing times for process evaluation.

Non-Newtonian Slurries↗

Thermal stability of sputter deposited nanomosaic rutile TiO{sub 2}

A domain structure based on the rutile lattice with a large density of (1/2)<011>{l_brace}011{r_brace}-type stacking faults is found in sputter deposited TiO{sub 2} films [J. Vac. Sci. Technol. A 24, 2054 (2006)]. The thermal stability of nanomosaic rutile at moderate temperature is reported here. Films are annealed at 973 K for 0.25-15 h, characterized by x-ray diffraction. A Johnson-Mehl-Avrami-Kolmogorov analysis indicates impeded crystallite growth. A dislocation-locking mechanism is proposed for this behavior. Partial dislocations with (1/2)<011> Burgers vectors that bound the stacking faults glide on intersecting {l_brace}011{r_brace} slip planes and react to produce sessile stair rod dislocations. Without the high temperature required for dislocation climb, (1/2)<011>{l_brace}011{r_brace}-type faults inherent to nanomosaic rutile provide thermal stability against massive crystallite growth.

36 MATERIALS SCIENCE↗

Numerical ellipsometry: Analysis of thin metal layers using n-k-d twisted curve methods with multiple incidence angles

A major challenge for those utilizing ellipsometry is numerical processing of the measured data. The transcendental, multivalued equations arising from the physics of simple reflection are problematic for the least-squares numerical methods in common use. These early numerical methods require fairly accurate initial estimates, bounding to avoid local minima, and only find solutions at the bottom of a relatively flat numerical topography. Previously the authors have applied complex analysis in the n-k plane to improve visualization of the mathematics, and this has led to a growing array of new numerical methods avoiding these difficulties. The work presented here extends these new numerical methods to three dimensions (n-k-d space) for use with absorbing films deposited on transparent and on absorbing substrates. The method finds intersections of three ''twisted curves'' resulting from three (or more) light incidence angle measurements per wavelength. The method is employed here to determine the thickness and optical properties of chromium films (between 10 and 25 nm nominal thickness) deposited onto two different substrates, silicon and silica oxide, employing measurements made at three different angles of incidence for light wavelengths between 280 and 2500 nm.

36 MATERIALS SCIENCE↗

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one concerned standard field, irregular entrance surface, and oblique incidence in a homogeneous PMMA phantom. The last group involved the introduction of inhomogeneities in a PMMA phantom to simulate high and low density materials such as bone and lung. Measurements in water were performed by means of cylindrical and plane-parallel ionization chambers, whereas measurements in PMMA were carried out by the use of radiochromic films. Point dose values were compared in terms of percentage difference, whereas the gamma index tool was used to perform the comparison between computed and measured dose profiles, considering different tolerances according to the test complexity. In the case of transverse scans, the agreement was searched in the plane formed by the intersection of beam axis and the profile (2D analysis), while for percentage depth dose curves, only the beam axis was explored (1D analysis). An excellent agreement was found for point dose evaluation in water (discrepancies smaller than 2%). Also the comparison between planned and measured dose profiles in homogeneous water and PMMA phantoms showed good results (agreement within 2%-2 mm). Profile evaluation in phantoms with internal inhomogeneities showed a good agreement in the case of ''lung'' insert, while in tests concerning a small ''bone'' inhomogeneity, a discrepancy was particularly evidenced in dose values on the beam axis. This is due to the inaccurate geometrical description of the phantom that is linked to the calculation voxel size, a feature over which the user has no control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beam-centric algorithm for pretreatment patient position correction in external beam radiation therapy

Purpose: In current image guided pretreatment patient position adjustment methods, image registration is used to determine alignment parameters. Since most positioning hardware lacks the full six degrees of freedom (DOF), accuracy is compromised. The authors show that such compromises are often unnecessary when one models the planned treatment beams as part of the adjustment calculation process. The authors present a flexible algorithm for determining optimal realizable adjustments for both step-and-shoot and arc delivery methods. Methods: The beam shape model is based on the polygonal intersection of each beam segment with the plane in pretreatment image volume that passes through machine isocenter perpendicular to the central axis of the beam. Under a virtual six-DOF correction, ideal positions of these polygon vertices are computed. The proposed method determines the couch, gantry, and collimator adjustments that minimize the total mismatch of all vertices over all segments with respect to their ideal positions. Using this geometric error metric as a function of the number of available DOF, the user may select the most desirable correction regime. Results: For a simulated treatment plan consisting of three equally weighted coplanar fixed beams, the authors achieve a 7% residual geometric error (with respect to the ideal correction, considered 0% error) by applying gantry rotation as well as translation and isocentric rotation of the couch. For a clinical head-and-neck intensity modulated radiotherapy plan with seven beams and five segments per beam, the corresponding error is 6%. Correction involving only couch translation (typical clinical practice) leads to a much larger 18% mismatch. Clinically significant consequences of more accurate adjustment are apparent in the dose volume histograms of target and critical structures. Conclusions: The algorithm achieves improvements in delivery accuracy using standard delivery hardware without significantly increasing total treatment session duration. It encourages parsimonious utilization of all available DOF. Finally, in certain cases, it obviates the need of a robotic couch having six DOF for the correction of patient displacement and rotations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computerized comprehensive data analysis of Lung Imaging Database Consortium (LIDC)

Purpose: Lung Image Database Consortium (LIDC) is the largest public CT image database of lung nodules. In this study, the authors present a comprehensive and the most updated analysis of this dynamically growing database under the help of a computerized tool, aiming to assist researchers to optimally use this database for lung cancer related investigations. Methods: The authors developed a computer scheme to automatically match the nodule outlines marked manually by radiologists on CT images. A large variety of characteristics regarding the annotated nodules in the database including volume, spiculation level, elongation, interobserver variability, as well as the intersection of delineated nodule voxels and overlapping ratio between the same nodules marked by different radiologists are automatically calculated and summarized. The scheme was applied to analyze all 157 examinations with complete annotation data currently available in LIDC dataset. Results: The scheme summarizes the statistical distributions of the abovementioned geometric and diagnosis features. Among the 391 nodules, (1) 365 (93.35%) have principal axis length {<=}20 mm; (2) 120, 75, 76, and 120 were marked by one, two, three, and four radiologists, respectively; and (3) 122 (32.48%) have the maximum volume overlapping ratios {>=}80% for the delineations of two radiologists, while 198 (50.64%) have the maximum volume overlapping ratios <60%. The results also showed that 72.89% of the nodules were assessed with malignancy score between 2 and 4, and only 7.93% of these nodules were considered as severely malignant (malignancy {>=}4). Conclusions: This study demonstrates that LIDC contains examinations covering a diverse distribution of nodule characteristics and it can be a useful resource to assess the performance of the nodule detection and/or segmentation schemes.

60 APPLIED LIFE SCIENCES↗

Waveguide detuning caused by transverse magnetic fields on a simulated in-line 6 MV linac

Purpose: Due to the close proximity of the linear accelerator (linac) to the magnetic resonance (MR) imager in linac-MR systems, it will be subjected to magnet fringe fields larger than the Earth's magnetic field of 5x10{sup -5} T. Even with passive or active shielding designed to reduce these fields, some magnitude of the magnetic field is still expected to intersect the linac, causing electron deflection and beam loss. This beam loss, resulting from magnetic fields that cannot be eliminated with shielding, can cause a detuning of the waveguide due to excessive heating. The detuning, if significant, could lead to an even further decrease in output above what would be expected strictly from electron deflections caused by an external magnetic field. Thus an investigation of detuning was performed through various simulations. Methods: According to the Lorentz force, the electrons will be deflected away from their straight course to the target, depositing energy as they impact the linac copper waveguide. The deposited energy would lead to a heating and deformation of the copper structure resulting in resonant frequency changes. PARMELA was used to determine the mean energy and fraction of total beam lost in each linac cavity. The energy deposited into the copper waveguide from the beam losses caused by transverse magnetic fields was calculated using the Monte Carlo program DOSRZnrc. From the total energy deposited, the rise in temperature and ultimately the deformation of the structure was estimated. The deformed structure was modeled using the finite element method program COMSOL MULTIPHYSICS to determine the change in cavity resonant frequency. Results: The largest changes in resonant frequency were found in the first two accelerating cavities for each field strength investigated. This was caused by a high electron fluence impacting the waveguide inner structures coupled with their low kinetic energies. At each field strength investigated, the total change in accelerator frequency was less than a manufacturing tolerance of 10 kHz and is thus not expected to have a noticeable effect on accelerator performance. Conclusions: The amount of beam loss caused by magnetic fringe fields for a linac in a linac-MR system depends on the effectiveness of its magnetic shielding. Despite the best efforts to shield the linac from the magnetic fringe fields, some persistent magnetic field is expected which would result in electron beam loss. This investigation showed that the detuning of the waveguide caused by additional electron beam loss in persistent magnetic fields is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy

Purpose: Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. Methods: For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an ''effective overlap volume histogram'' the authors derived an ''interpolated balanced planning target'' intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Results: Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V{sub 10}, V{sub 20}, and V{sub 30} of 6.3% {+-} 1.7%, 10.6% {+-} 3.9%, and 12.9% {+-} 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% {+-} 2.5%, 7.2% {+-} 2.5%, and 10.6% {+-} 3.6%, respectively. Conclusions: The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94.62%, respectively, for the bolus ECT plans and 89.2% and 95.1%, respectively, for the mixed beam plans. For all regions, pass rates for the parotid and CW plans were 98.8% and 97.3%, respectively, for the bolus ECT plans and 97.5% and 95.9%, respectively, for the mixed beam plans. For the IMXT component of the mixed beam plans, pass rates for the parotid and CW plans were 93.7% and 95.8%. Conclusions: Bolus ECT and mixed beam therapy dose delivery to the phantom were more accurate than IMXT delivery, adding confidence to the use of planning, fabrication, and delivery for bolus ECT tools either alone or as part of mixed beam therapy. The methodology reported in this work could serve as a basis for future standardization of the commissioning of bolus ECT or mixed beam therapy. When applying this technology to patients, it is recommended that an electron dose algorithm more accurate than the pencil beam algorithm, e.g., a Monte Carlo algorithm or analytical transport such as the pencil beam redefinition algorithm, be used for planning to ensure the desired accuracy.

60 APPLIED LIFE SCIENCES↗

A comprehensive investigation of the accuracy and reproducibility of a multitarget single isocenter VMAT radiosurgery technique

Purpose: Recent trends in stereotactic radiosurgery use multifocal volumetric modulated arc therapy (VMAT) plans to simultaneously treat several distinct targets. Conventional verification often involves low resolution measurements in a single plane, a cylinder, or intersecting planes of diodes or ion chambers. This work presents an investigation into the consistency and reproducibility of this new treatment technique using a comprehensive commissioned high-resolution 3D dosimetry system (PRESAGE{sup ®}/Optical-CT).Methods: A complex VMAT plan consisting of a single isocenter but five separate targets was created in Eclipse for a head phantom containing a cylindrical PRESAGE{sup ®} dosimetry insert of 11 cm diameter and height. The plan contained five VMAT arcs delivering target doses from 12 to 20 Gy. The treatment was delivered to four dosimeters positioned in the head phantom and repeated four times, yielding four separate 3D dosimetry verifications. Each delivery was completely independent and was given after image guided radiation therapy (IGRT) positioning using Brainlab ExacTrac and cone beam computed tomography. A final delivery was given to a modified insert containing a pin-point ion chamber enabling calibration of PRESAGE{sup ®} 3D data to dose. Dosimetric data were read out in an optical-CT scanner. Consistency and reproducibility of the treatment technique (including IGRT setup) was investigated by comparing the dose distributions in the four inserts, and with the predicted treatment planning system distribution.Results: Dose distributions from the four dosimeters were registered and analyzed to determine the mean and standard deviation at all points throughout the dosimeters. A dose standard deviation of <3% was found from dosimeter to dosimeter. Global 3D gamma maps show that the predicted and measured dose matched well [3D gamma passing rate was 98.0% (3%, 2 mm)].Conclusions: The deliveries of the irradiation were found to be consistent and matched the treatment plan, demonstrating high accuracy and reproducibility of both the treatment machine and the IGRT procedure. The complexity of the treatment (multiple arcs) and dosimetry (multiple strong gradients) pose a substantial challenge for comprehensive verification. 3D dosimetry can be uniquely effective in this scenario.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment

Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. Conclusions: The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure spectra from the clinical system across a range of angular trajectories [−15°, 15°] and spectrum settings (80, 100, 120, 140 kVp). Results: At 140 kVp, the proposed technique was comparable to the conventional technique in terms of the mean energy difference (MED, −0.29 keV) and the normalized root mean square difference (NRMSD, 0.84%) from the comparison standard compared to 0.64 keV and 1.56%, respectively, with the conventional technique. The average absolute MEDs and NRMSDs across kVp settings and angular trajectories were less than 0.61 keV and 3.41%, respectively, which indicates a high level of estimation accuracy and stability. Conclusions: An angle-dependent estimation technique of CT x-ray spectra from rotational transmission measurements was proposed. Compared with the conventional technique, the proposed method simplifies the measurement procedures and enables incident spectral estimation for a wide range of angular trajectories. The proposed technique is suitable for rigorous research objectives as well as routine clinical quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-66: Radiomics and Image Registration Updates for the Computational Environment for Radiotherapy Research (CERR)

Purpose: To present new tools in CERR for Radiomics, image registration and other software updates and additions. Methods: Radiomics: CERR supports generating 3-D texture metrics based on gray scale co-occurance. Two new ways to calculate texture features were added: (1) Local Texture Averaging: Local texture is calculated around a voxel within the userdefined bounding box. The final texture metrics are the average of local textures for all the voxels. This is useful to detect any local texture patterns within an image. (2) Image Smoothing: A convolution ball of user-defined radius is rolled over an image to smooth out artifacts. The texture metrics are then computed on the smooth image. Image Registration: (1) Support was added to import deformation vector fields as well as non-deformable transformation matrices generated by vendor software and stored in standard DICOM format. (2) Support was added to use image within masks while computing image deformations. CT to MR registration is supported. This registration uses morphological edge information within the images to guide the deformation process. In addition to these features, other noteworthy additions to CERR include (1) Irregularly shaped ROI: This is done by taking intersection between infinitely extended irregular polygons drawn on any of the two views. Such an ROI is more conformal and useful in avoiding any unwanted parts of images that cannot be avoided with the conventional cubic box. The ROI is useful to generate Radiomics metrics. (2) Ability to insert RTDOSE in DICOM format to existing CERR plans. (3) Ability to import multi-frame PET-CT and SPECT-CT while maintaining spatial registration between the two modalities. (4) Ability to compile CERR on Unix-like systems. Results: The new features and updates are available via https://www.github.com/adityaapte/cerr . Conclusion: Features added to CERR increase its utility in Radiomics, Image-Registration and Outcomes modeling.

07 ISOTOPE AND RADIATION SOURCES↗

Refine your search to explore more results.