Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOGARITHM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Kinematic flow from the flow of cuts

The wavefunction coefficients of conformally coupled scalars in power-law FRW cosmologies satisfy differential equations governed by a set of simple combinatorial rules known as the kinematic flow. In this paper we derive the kinematic flow, expressed using a set of differential forms referred to as the cut basis, from a geometric perspective, relying solely on the cosmological hyperplane arrangement and without invoking bulk physics. Each element of the cut basis corresponds to the positive geometry associated to an independent cut of the physical FRW-form and can be labeled by decorating (minors of) the truncated Feynman graph with an acyclic orientation. We provide a straightforward prescription to associate a logarithmic differential form to each element of the cut basis by considering its corresponding decorated graph. Moreover, we show that the residues of the physical FRW-form are canonical forms of certain graphical zonotopes labeled by the same set of decorated graphs. These zonotopes control the cut combinatorics -- flow of cuts -- of the physical FRW-form and the cut basis (by construction). Using the theory of relative twisted cohomology and intersection theory, we derive a closed form formula for the differential equations of the cut basis. We also introduce combinatorial rules that compute the kinematic differential of any basis element without explicit calculation. The combinatorics of our differential equations is a natural consequence of the flow of cuts and is equivalent (up to rescaling) to the kinematic flow for the recently studied time integral basis. In particular, our differential equations decouple into exponentially many sectors, one for each way of cutting a subset of edges of the graph.

General Relativity and Quantum Cosmology↗

SIDIS Unpolarized Cross Sections from a 3 He Target with the Solenoidal Large Intensity Device at JLab

In this paper we present a detailed impact study of semi-inclusive deep inelastic scattering unpolarized cross sections' measurements using the proposed SoLID apparatus at Jefferson Lab. This type of data, collected at large Bjorken x bj , moderate values of Q 2 and small values of the transverse momentum of produced hadrons, P hT , allows to study transverse momentum dependent (TMD) parton distribution and fragmentation functions in a still poorly explored region. We present the projected results for charged light mesons based on simulated data. For the azimuthal-angle integrated cross sections we adopt the TMD framework up to the next-to-next-to-next-to-leading-logarithmic accuracy, while a simpler TMD parton model is employed for the study of azimuthal angular dependencies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bioaerosol Properties using WIBS from SAIL on Mt. Crested Butte, CO

We deployed a Wideband Integrated Bioaerosol Sensor (WIBS-Neo, DMT) to measure different properties of fluorescent bioaerosol particles (FBAP) during SAIL. Our measurements were collected at the supplementary site on Crested Butte Mountain from inside the ARM Aerosol Observing System (AOS) sampling from the AOS inlet. We had two deployment periods at SAIL during biologically active seasons: summer 2022 (15 June 2022 - 13 September 2022) and spring 2023 (21 March 2023 - 19 June 2023). The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Here, we report one-minute averaged number concentration of FBAPs (total and by category) and NFBAPs. We also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins is the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. We recommend referring to the readme file for more details of the variables present in the files. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153-1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here: https://www.arm.gov/research/cam

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Measuring the Speed of Sound Using Cumulants of Baryon Number

Here, we show that the values of the first three cumulants of the baryon number distribution can be used to calculate the isothermal speed of sound and its logarithmic derivative with respect to the baryon-number density. We discuss applications of this result to heavy-ion collision experiments and address possible challenges, including effects due to baryon-number conservation, differences between proton and baryon cumulants, and the influence of finite-number statistics on fluctuation observables in both ex periment and hadronic transport simulations. In particular, we investigate the relation between quantities calculated in infinite, continuous matter, and observables obtained in simulations using a finite number of particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical Correlation of Heliostat Pointing Deviation With Wind

This work was carried out as part of the Heliostat Consortium (HelioCon) Field Deployment subtask with the aim to develop a reduced order model framework for correlating wind speed and pointing deviation of a heliostat facet. There are only sparse field measurements of heliostat pointing deviations and accompanying wind conditions published in the literature. Heliostat test standards, such as IEC 62862-4-3, propose a suite of tests including laser pointing repeatability at wind speeds below 4 m/s, and provide technical requirements for heliostat slope and tracking deviations in coarse average wind speed bins of 4 m/s, 6 m/s, and 8 m/s. In addressing the gap of the variation of heliostat pointing deviation with wind speed, field measurements of laser pointing on a grid target and wind conditions were analyzed in this study at the Third-Party Metrology Platform at the National Laboratory of the Rockies (NLR) Flatirons Campus. Horizontal pointing deviations were found to follow a logarithmic relationship with peak wind speed, whereas vertical pointing deviations follow an exponential relationship with peak wind speed. Both horizontal and vertical pointing deviations also follow a second order polynomial relationship, as expected from the proportionality of elastic loads and deformations with the square of wind speed. The results indicate that heliostat facet pointing deviations in the vertical direction increase at a faster rate than in the horizontal direction with increasing wind speed over the tested range, however these are dependent on the heliostat structural design. Next steps are recommended for additional field measurements to confirm a linear relationship of pointing deviation with applied moment on a heliostat facet, and to distinguish between gravity-induced and wind-induced pointing deviations at different elevation angles. The derived correlations in the preliminary analysis in this report serve as a case study for heliostat developers and plant operators to estimate the wind-induced pointing deviations and their variation with peak gust wind speed. Next steps in future work would recommend higher resolution and longer duration datasets for different elevation angles and wind directions to reduce uncertainties and variance of collected laser beam spot data and their correlations with bin-averaged wind speed.

17 WIND ENERGY↗

The Fluorescent Decay of CsI(T1) Excited by Charged Particles

The fluorescence from a CsI(0.08% T1) scintillator excited by charged particles which come to a stop within the scintillator has been measured for alpha particles, deuterons, and protons. In the region 0.1 to 0.6 microseconds after its initial rise, the fluorescent decay can be accurately described by a simple exponential. The characteristic time for this exponential decay has been measured at several energies up to 28.7 MeV for a particles and 7.2 MeV for protons. We have found a linear relationship between this decay time and the logarithm of the particle energy, τ = k ln E + τo, where k and τo are constants which are characteristic of the type of stopping particle.

Womack, E. A.↗

Sensitive electrometer features digital output

Four-stage transistorized electrometer eliminates the need for a logarithmic compression network. It measures very low currents and produces a digital output directly indicative of the input current magnitude.

Doong, H.↗

Fragmentation history of asteroids.

Fragmentation history of asteroids derived from absolute magnitude distribution resembling Gaussian curve for brighter members and logarithmic curve for fainter ones

PLANETARY EVOLUTION↗

Simple scale interpolator facilitates reading of graphs

Set of cards with scale divisions and a scale finder permits accurate reading of the coordinates of points on linear or logarithmic graphs plotted on rectangular grids. The set contains 34 different scales for linear plotting and 28 single cycle scales for log plots.

Fazio, A.↗

Stress calculator speedily converts strain data

Stress calculator permits speedy conversion of strain data directly into maximum and minimum stresses and also determines stress direction. The calculator has a movable slide with logarithmic and linear scales, and an information and grid board. Its size is flexible for easy manipulation.

Cornett, D. W.↗

Solubility data are compiled for metals in liquid zinc

Available data is compiled on the solubilities of various metals in liquid zinc. The temperature dependence of the solubility data is expressed using the empirical straight line relationship existing between the logarithm of the solubility and the reciprocal of the absolute temperature.

Dillon, I. G.↗

Study of corrosion of 1100 aluminum

Corrosion of 1100 aluminum in oxygen-saturated water at 70 degrees C under experimental conditions was studied, emphasizing effects of exposure interruption, the number of specimens, and the refreshment rate. A logarithmic equation was derived to express the corrosion rate.

Draley, J. E.↗

Log-normal model for microbial survival in heat sterilization

An analytical model is developed for the survival times of organisms in heat sterilization in which the probability of inactivation as a function of exposure time is log-normally distributed. Experimental data is examined relative to this model and it is concluded that the model is valid except during the initial period of heating when an additional interaction between the organisms and their surrounding medium appears to be present. At long heating times, the log-normal model appears more accurate for extrapolating to low survival probabilities than the usual logarithmic survivor curves and is generally more conservative.

SURVIVAL↗

Refine your search to explore more results.