Estimates of Ground Temperature and Atmospheric Moisture from CERES Observations

A method is developed to retrieve surface ground temperature (Tg) and atmospheric moisture using clear sky fluxes (CSF) from CERES-TRMM observations. In general, the clear sky outgoing long-wave radiation (CLR) is sensitive to upper level moisture (q(sub h)) over wet regions and Tg over dry regions The clear sky window flux from 800 to 1200 /cm (RadWn) is sensitive to low level moisture (q(sub j)) and Tg. Combining these two measurements (CLR and RadWn), Tg and q(sub h) can be estimated over land, while q(sub h) and q(sub t) can be estimated over the oceans. The approach capitalizes on the availability of satellite estimates of CLR and RadWn and other auxiliary satellite data. The basic methodology employs off-line forward radiative transfer calculations to generate synthetic CSF data from two different global 4-dimensional data assimilation products. Simple linear regression is used to relate discrepancies in CSF to discrepancies in Tg, q(sub h) and q(sub t). The slopes of the regression lines define sensitivity parameters that can be exploited to help interpret mismatches between satellite observations and model-based estimates of CSF. For illustration, we analyze the discrepancies in the CSF between an early implementation of the Goddard Earth Observing System Data Assimilation System (GEOS-DAS) and a recent operational version of the European Center for Medium-Range Weather Prediction data assimilation system. In particular, our analysis of synthetic total and window region SCF differences (computed from two different assimilated data sets) shows that simple linear regression employing (Delta)Tg and broad layer (Delta)q(sub l) from 500 hPa to surface and (Delta)q(sub h) from 200 to 500 hPa provides a good approximation to the full radiative transfer calculations, typically explaining more than 90% of the 6-hourly variance in the flux differences. These simple regression relations can be inverted to "retrieve" the errors in the geophysical parameters. Uncertainties (normalized by standard deviation) in the monthly mean retrieved parameters range from 7% for (Delta)T to about 20% for (Delta)q(sub t). Our initial application of the methodology employed an early CERES-TRMM data set (CLR and Radwn) to assess the quality of the GEOS2 data. The results showed that over the tropical and subtropical oceans GEOS2 is, in general, too wet in the upper troposphere (mean bias of 0.99 mm) and too dry in the lower troposphere (mean bias of -4.7 mm). We note that these errors, as well as a cold bias in the Tg, have largely been corrected in the current version of GEOS-2 with the introduction of a land surface model, a moist turbulence scheme and the assimilation of SSTM/I total precipitable water.

Wu, Man Li C.↗

Statistical Techniques For Real-time Anomaly Detection Using Spark Over Multi-source VMware Performance Data

Anomaly detection refers to the identi cation of an irregular or unusual pat- tern which deviates from what is standard, normal, or expected. Such deviated patterns typically correspond to samples of interest and are assigned different labels in different domains, such as outliers, anomalies, exceptions, or malware. Detecting anomalies in fast, voluminous streams of data is a formidable chal- lenge. This paper presents a novel, generic, real-time distributed anomaly detection framework for heterogeneous streaming data where anomalies appear as a group. We have developed a distributed statistical approach to build a model and later use it to detect anomaly. As a case study, we investigate group anomaly de- tection for a VMware-based cloud data center, which maintains a large number of virtual machines (VMs). We have built our framework using Apache Spark to get higher throughput and lower data processing time on streaming data. We have developed a window-based statistical anomaly detection technique to detect anomalies that appear sporadically. We then relaxed this constraint with higher accuracy by implementing a cluster-based technique to detect sporadic and continuous anomalies. We conclude that our cluster-based technique out- performs other statistical techniques with higher accuracy and lower processing time.

Apache Spark↗

An experimental investigation of gas fuel injection with X-ray radiography

In this paper, an outward-opening compressed natural gas, direct injection fuel injector has been studied with single-shot x-ray radiography. Three dimensional simulations have also been performed to compliment the x-ray data. Argon was used as a surrogate gas for experimental and safety reasons. This technique allows the acquisition of a quantitative mapping of the ensemble-average and standard deviation of the projected density throughout the injection event. Two dimensional, ensemble average and standard deviation data are presented to investigate the quasi-steady-state behavior of the jet. Upstream of the stagnation zone, minimal shot-to-shot variation is observed. Downstream of the stagnation zone, bulk mixing is observed as the jet transitions to a subsonic turbulent jet. From the time averaged data, individual slices at all downstream locations are extracted and an Abel inversion was performed to compute the radial density distribution, which was interpolated to create three dimensional visualizations. The Abel reconstructions reveal that upstream of the stagnation zone, the gas forms an annulus with high argon density and large density gradients. Inside this annulus, a recirculation region with low argon density exists. Downstream, the jet transitions to a fully turbulent jet with Gaussian argon density distributions. This experimental data is intended to serve as a quantitative benchmark for simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations

Purpose: To quantify the ability of electronic portal imaging device (EPID) dosimetry used during treatment (in vivo) in detecting variations that can occur in the course of patient treatment. Methods: Images of transmitted radiation from in vivo EPID measurements were converted to a 2D planar dose at isocenter and compared to the treatment planning dose using a prototype software system. Using the treatment planning system (TPS), four different types of variability were modeled: overall dose scaling, shifting the positions of the multileaf collimator (MLC) leaves, shifting of the patient position, and changes in the patient body contour. The gamma pass rate was calculated for the modified and unmodified plans and used to construct a receiver operator characteristic (ROC) curve to assess the detectability of the different parameter variations. The detectability is given by the area under the ROC curve (AUC). The TPS was also used to calculate the impact of the variations on the target dose–volume histogram. Results: Nine intensity modulation radiation therapy plans were measured for four different anatomical sites consisting of 70 separate fields. Results show that in vivo EPID dosimetry was most sensitive to variations in the machine output, AUC = 0.70 − 0.94, changes in patient body habitus, AUC = 0.67 − 0.88, and systematic shifts in the MLC bank positions, AUC = 0.59 − 0.82. These deviations are expected to have a relatively small clinical impact [planning target volume (PTV) D{sub 99} change <7%]. Larger variations have even higher detectability. Displacements in the patient’s position and random variations in MLC leaf positions were not readily detectable, AUC < 0.64. The D{sub 99} of the PTV changed by up to 57% for the patient position shifts considered here. Conclusions: In vivo EPID dosimetry is able to detect relatively small variations in overall dose, systematic shifts of the MLC’s, and changes in the patient habitus. Shifts in the patient’s position which can introduce large changes in the target dose coverage were not readily detected.

60 APPLIED LIFE SCIENCES↗

Searches for large-scale anisotropy in the arrival directions of cosmic rays detected above energy of 10{sup 19} eV at the Pierre Auger observatory and the telescope array

Spherical harmonic moments are well-suited for capturing anisotropy at any scale in the flux of cosmic rays. An unambiguous measurement of the full set of spherical harmonic coefficients requires full-sky coverage. This can be achieved by combining data from observatories located in both the northern and southern hemispheres. To this end, a joint analysis using data recorded at the Telescope Array and the Pierre Auger Observatory above 10{sup 19} eV is presented in this work. The resulting multipolar expansion of the flux of cosmic rays allows us to perform a series of anisotropy searches, and in particular to report on the angular power spectrum of cosmic rays above 10{sup 19} eV. No significant deviation from isotropic expectations is found throughout the analyses performed. Upper limits on the amplitudes of the dipole and quadrupole moments are derived as a function of the direction in the sky, varying between 7% and 13% for the dipole and between 7% and 10% for a symmetric quadrupole.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the dynamic response of rock masses with multiple compliant fluid saturated joint sets - Part II: Continuum modeling

Part I of this two-part paper describes enhancements of a mesoscale model to include: many non-persistent fluid saturated joints with finite area, normal compliance with hysteresis and the weakening effects of angular deviation in the joint sets and of fluid pressure in the joints. The objective of this Part II is to use the results of the mesoscale model as simulated data to inspire functional forms in a continuum model for rock masses with multiple compliant fluid saturated joint sets which include these enhancements. Also, an algorithm is proposed for reducing the number of joint sets being modeled. Examples are presented here which show that the continuum model can predict similar anisotropic response to that observed in mesoscale simulations. In contrast with the mesoscale model, the continuum model can be used for large scale simulations of real applications, smoothly transitioning from coupled inelastic thermomechanical response near an explosive source to orthotropic elastic response far from the source.

58 GEOSCIENCES↗

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

The mechanical properties of Kel-F 800 (FK-800) as a function of crystallinity

Kel-F 800 is a copolymer of chlorotrifluoroethylene PTFE (75 wt. %) and vinylidene fluoride PVDF (25 wt. %). It has previously been used as a PBX binder for insensitive explosives such as PBX 9502 and LX-17. 3M started production of Kel-F 800 in 1957 and small-scale batches continued to be made until 2002 when production ceased due to environmental concerns regarding one of the emulsifiers used during production. Around 2000 the Kel-F 800 name was changed to FK-800 to avoid trademark concerns because rights to produce another polymer with a similar tradename (Kel-F 81) had been sold to another manufacturer. The Kel designation came from the original manufacturer of PCTFE (Kel-F 81), the Kellog company. To avoid confusion this document will only refer to Kel-F 800. In 2006, production of small-scale batches of Kel-F 800 was started again by 3M in response to customer enquiries. This new material, the first blended batch is referred to as LOT 1, was produced with a different emulsifier than used previously. Because Kel-F 800 is made in a small batch reactor, considerable variation in crystallinity can be expected from lot to lot and year to year. In many ways, this is not significant since the material is dissolved in a solvent (often MEK, ethylmethyl ketone or ethyl acetate) for PBX production purposes. This destroys the as received crystallinity and the resulting crystallinity in the processed material is a function of polymer molecular weight and thermal history. Producing large billets of Kel-F 800 from solvent extraction is not practical and so a compression molding technique has been used above the melting temperature. This method also removes residual crystallinity from the supplied granules. The molecular weight of a polymer can be estimated by several techniques, the most common being gel permittivity chromatography (GPC), size exclusion chromatography (SEC) and shear rheometry measurements of polymer/solvent solutions. Changes in molecular weight will affect the crystallization rate and the maximum crystallinity reached for a specific thermal history. Both references agree that the new LOT 1 material molecular weight falls within the deviation found from averaging previous historical lots of Kel-F 800.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistics of Cirrus Horizontal Inhomogeneity in the Southern Great Plains

Variability of cloud properties on scales smaller than that of a GCM grid is potentially important both for realistic parameterizations of microphysical processes and for the prediction of the large-scale radiative effects of clouds, have suggested that a simple model of marine stratocumulus variability, based on the assumption of Gaussian variation statistics of cloud depth, can explain the liquid water path histogram shapes observed in Landsat data. In advance of ARM SGP MMCR ice water path climatologies, we have examined aircraft ice water content statistics for cirrus clouds observed over Coffeyville, Kansas during FIRE 2. We find similar associations of histogram shape and cloud cover for these clouds, and we show that a simple modification of the model for cirrus combined with observed mean cloud depths, their standard deviations, and ambient thermodynamic conditions predicts both the histogram shape and cirrus cloud cover fairly well. This suggests that subgrid variability of cloud properties may be similar for vastly different cloud types, and that a universal parameterization of the effects of subgrid variability in GCMs as a function of only a few parameters may be a realistic goal.

Smith, S. A.↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Repeatability of Cryogenic Multilayer Insulation

Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

multilayer insulation↗

Astrophysical Tests of Dark Matter with Maunakea Spectroscopic Explorer

We discuss how astrophysical observations with the Maunakea Spectroscopic Explorer (MSE), a high-multiplexity (about 4300 fibers), wide field-of-view (1.5 square degree), large telescope aperture (11.25 m) facility, can probe the particle nature of dark matter. MSE will conduct a suite of surveys that will provide critical input for determinations of the mass function, phase-space distribution, and internal density profiles of dark matter halos across all mass scales. N-body and hydrodynamical simulations of cold, warm, fuzzy and self-interacting dark matter suggest that non-trivial dynamics in the dark sector could have left an imprint on structure formation. Analysed within these frameworks, the extensive and unprecedented datasets produced by MSE will be used to search for deviations away from cold and collisionless dark matter model. MSE will provide an improved estimate of the local density of dark matter, critical for direct detection experiments, and will improve estimates of the J-factor for indirect searches through self-annihilation or decay into Standard Model particles. MSE will determine the impact of low mass substructures on the dynamics of Milky Way stellar streams in velocity space, and will allow for estimates of the density profiles of the dark matter halos of Milky Way dwarf galaxies using more than an order of magnitude more tracers. In the low redshift Universe, MSE will provide critical redshifts to pin down the luminosity functions of vast numbers of satellite systems, and MSE will be an essential component of future strong lensing measurements to constrain the halo mass function. Across nearly all mass scales, the improvements offered by MSE, in comparison to other facilities, are such that the relevant analyses are limited by systematics rather than statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: Cosmological implications from two decades of spectroscopic surveys at the Apache Point Observatory

We present the cosmological implications from final measurements of clustering using galaxies, quasars, and Lyα forests from the completed Sloan Digital Sky Survey (SDSS) lineage of experiments in large-scale structure. These experiments, composed of data from SDSS, SDSS-II, BOSS, and eBOSS, offer independent measurements of baryon acoustic oscillation (BAO) measurements of angular-diameter distances and Hubble distances relative to the sound horizon, r d , from eight different samples and six measurements of the growth rate parameter, fσ 8 , from redshift-space distortions (RSD). This composite sample is the most constraining of its kind and allows us to perform a comprehensive assessment of the cosmological model after two decades of dedicated spectroscopic observation. We show that the BAO data alone are able to rule out dark-energy-free models at more than eight standard deviations in an extension to the flat, ΛCDM model that allows for curvature. When combined with Planck Cosmic Microwave Background (CMB) measurements of temperature and polarization, under the same model, the BAO data provide nearly an order of magnitude improvement on curvature constraints relative to primary CMB constraints alone. Independent of distance measurements, the SDSS RSD data complement weak lensing measurements from the Dark Energy Survey (DES) in demonstrating a preference for a flat ΛCDM cosmological model when combined with Planck measurements. The combined BAO and RSD measurements indicate σ 8 =0.85±0.03, implying a growth rate that is consistent with predictions from Planck temperature and polarization data and with General Relativity. When combining the results of SDSS BAO and RSD, Planck, Pantheon Type Ia supernovae (SNe Ia), and DES weak lensing and clustering measurements, all multiple-parameter extensions remain consistent with a ΛCDM model. Regardless of cosmological model, the precision on each of the three parameters, Ω Λ , H 0 , and σ 8 , remains at roughly 1%, showing changes of less than 0.6% in the central values between models. In a model that allows for free curvature and a time-evolving equation of state for dark energy, the combined samples produce a constraint Ω K =-0.0022±0.0022. The dark energy constraints lead to w 0 =-0.909±0.081 and w a =$-0.49_{-0.30}^{+0.35}$, corresponding to an equation of state of w p =-1.018±0.032 at a pivot redshift z p =0.29 and a Dark Energy Task Force Figure of Merit of 94. The inverse distance ladder measurement under this model yields H 0 =68.18±0.79 km s -1 Mpc -1 , remaining in tension with several direct determination methods; the BAO data allow Hubble constant estimates that are robust against the assumption of the cosmological model. In addition, the BAO data allow estimates of H 0 that are independent of the CMB data, with similar central values and precision under a ΛCDM model. Our most constraining combination of data gives the upper limit on the sum of neutrino masses at Σm ν <0.115 eV (95% confidence). Finally, we consider the improvements in cosmology constraints over the last decade by comparing our results to a sample representative of the period 2000-2010. We compute the relative gain across the five dimensions spanned by w, Ω k , Σm ν , H 0 , and σ 8 and find that the SDSS BAO and RSD data reduce the total posterior volume by a factor of 40 relative to the previous generation. Finally, adding again the Planck, DES, and Pantheon SN Ia samples leads to an overall contraction in the five-dimensional posterior volume of 3 orders of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection and imaging of the oxygen deficiency in single crystalline YBa{sub 2}Cu{sub 3}O{sub 7−δ} thin films using a scanning positron beam

Single crystalline YBa{sub 2}Cu{sub 3}O{sub 7−δ} (YBCO) thin films were grown by pulsed laser deposition in order to probe the oxygen deficiency δ using a mono-energetic positron beam. The sample set covered a large range of δ (0.191 < δ < 0.791) yielding a variation of the critical temperature T{sub c} between 25 and 90 K. We found a linear correlation between the Doppler broadening of the positron electron annihilation line and δ determined by X-ray diffraction. Ab-initio calculations have been performed in order to exclude the presence of Y vacancies and to ensure the negligible influence of potentially present Ba or Cu vacancies to the found correlation. Moreover, scanning with the positron beam allowed us to analyze the spatial variation of δ, which was found to fluctuate with a standard deviation of up to 0.079(5) within a single YBCO film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental determination of phonon thermal conductivity and Lorenz ratio of single crystal metals: Al, Cu, and Zn

We use a magnetothermal resistance method to measure lattice thermal conductivity of pure single crystal metals over the intermediate temperature range of 5–60 K. Large transverse magnetic fields are applied to suppress electronic thermal conduction. The total thermal conductivity and the electrical conductivity are measured as functions of applied magnetic field. The lattice thermal conductivity is then extracted by extrapolating the thermal conductivity versus electrical conductivity curve at zero electrical conductivity. We used this method to experimentally measure the lattice thermal conductivity and Lorenz number in single crystal Al (100), Cu (100), and Zn (001) in the intermediate temperature range. Our results show that the measured phonon thermal conductivity versus temperature plot has a peak around ΘD/10, and the Lorenz number is found to deviate from the Sommerfeld value in the intermediate temperature range.

Yao, Mengliang↗

Anomalous and planar Hall effects in Co 1−x Ho x thin films across the magnetic sublattice compensation temperature

Metallic amorphous ferrimagnets derived from alloying 3d transition metals with 4f-electron rare earths host fascinating effects of compensation between the 3d and 4f magnetic sublattices. Here, a detailed study of the anisotropic magnetoresistance (Δρ xx ), planar Hall effect (ρ xy PHE ), and anomalous Hall effect (ρ xy AHE ) is reported on a series of Co 1−x Ho x thin films over a wide field–temperature (H–T) phase space. Close to the magnetic compensation temperature, the ρ xy AHE –H loops show a double sign reversal and signatures of spin-flop transition at higher fields. The Δρ xx and ρ xy PHE also display strong deviations from the classical angular dependence seen in soft ferromagnets like permalloy as the angle ϕ between in-plane current and magnetic field is scanned from 0 to 2π. It is argued that the non-zero orbital angular momentum of Ho ions in the lattice and stabilization of bubble domains below magnetic saturation may be responsible for such features. Direct imaging of magnetic textures with x-ray photoelectron microscopy shows the formation of stripe domain patterns in the regime of sublattice compensation. Such stripes are likely to transform into magnetic bubbles before full saturation is reached in a large magnetic field.

36 MATERIALS SCIENCE↗

Bowen fluorescence in AM Herculis stars

The study relates the observations of the Bowen fluorescence lines in AM Her and EF Eri, two AM Her systems. The implications of source variability and the checks performed in order to verify the accuracy of the data are reviewed. The line ratios for H I and He II are shown to deviate considerably from those expected; in this light, the H I and He II emission in AM Her is analyzed in detail. This approach makes it possible to put limits on line and continuum optical depths as well as temperatures. These limits along with the observed Bowen emission are used to construct a picture of the emission-line regions in the two sources, producing the values for the size, density, and temperature of a region. The derived value of the size is found to be significantly less than the size of the Roche lobe of the white dwarf, while the large range of densities is attributed to the exponential temperature dependence in the expression used for density.

Schachter, Jonathan↗

Differential cross section measurements for the production of top quark pairs and of additional jets using dilepton events from pp collisions at $\sqrt{s}$ = 13 TeV

Differential cross sections for top quark pair ($\textrm{t}\overline{\textrm{t}}$) production are measured in proton-proton collisions at a center-of-mass energy of 13 TeV using a sample of events containing two oppositely charged leptons. The data were recorded with the CMS detector at the CERN Large Hadron Collider and correspond to an integrated luminosity of 138 fb −1 . The differential cross sections are measured as functions of kinematic observables of the $\textrm{t}\overline{\textrm{t}}$ system, the top quark and antiquark and their decay products, as well as of the number of additional jets in the event. The results are presented as functions of up to three variables and are corrected to the parton and particle levels. When compared to standard model predictions based on quantum chromodynamics at different levels of accuracy, it is found that the calculations do not always describe the observed data. The deviations are found to be largest for the multi-differential cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Refine your search to explore more results.