Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Status of intense permanent magnet proton source for China-accelerator driven sub-critical system Linac

Two compact intense 2.45 GHz permanent magnet proton sources and their corresponding low energy beam transport (LEBT) system were developed successfully for China accelerator driven sub-critical system in 2014. Both the proton sources operate at 35 kV potential. The beams extracted from the ion source are transported by the LEBT, which is composed of two identical solenoids, to the 2.1 MeV Radio-Frequency Quadrupole (RFQ). In order to ensure the safety of the superconducting cavities during commissioning, an electrostatic-chopper has been designed and installed in the LEBT line that can chop the continuous wave beam into a pulsed one. The minimum width of the pulse is less than 10 μs and the fall/rise time of the chopper is about 20 ns. The performance of the proton source and the LEBT, such as beam current, beam profile, emittance and the impact to RFQ injection will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptation of existing facilities to isentropic compression experiments

We demonstrate that the established pulsed power infrastructure at the National High Magnetic Field Laboratory - Pulsed Field Facility (NHMFL-PFF) at the Los Alamos National Laboratory can be adapted to obtain high quality isentropic compression experiment (ICE) data on materials in extreme conditions of dynamic high pressure. Experiments utilized a single-turn magnet pulsed power system at the NHMFL-PFF that was originally designed to measure actinide samples in extremes of high magnetic field (to 300 Tesla). A simple modification to the single-turn magnet has converted it to a fast turnaround dynamic high pressure measurement system. This paper details the work done including important background details that indicate that much more can be accomplished with optimization of the load characteristics in terms of ultimate peak pressures. To match the rise time of the NHMFL capacitor bank ({approx}2 {mu}s versus {approx}0.5 {mu}s for the Sandia Z-machine) the sample dimensions can be relatively large, i.e., up to 5 mm thickness. The maximum stresses are {approx}50GPa (0.5 Mbar) at the maximum bank voltage (60 kV) and higher pressures may be possible if the sample is tamped. For the design and predictions of performance of the NHMFL-ICE experiment it is important to have good predictive models. A SPICE code simulation was chosen to model all aspects of the experiment, electrical and physical. To this end, accurate dynamic load models were developed to simulate the compression and expansion of the dynamic load at high pressures using shock physics principles. A series experiments have been performed which demonstrated the feasibility of the NHMFL-ICE technique. The results will be shown and discussed. The NHMFL-ICE technique is an excellent method for measuring equations of state (EOS) at megabar pressures. Because a complete EOS can be obtained in one experiment from zero to the peak pressure, and because many shots can be fired in one day, the technique promises to provide high quality EOS data at relatively low cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetized laser–plasma interactions in high-energy-density systems: Parallel propagation

In this study, we investigate parametric processes in magnetized plasmas, driven by a large-amplitude pump light wave. Our focus is on laser–plasma interactions relevant to high-energy-density (HED) systems, such as the National Ignition Facility and the Sandia MagLIF concept. We present a self-contained derivation of a “parametric” dispersion relation for magnetized three-wave interactions, meaning the pump wave is included in the equilibrium, similar to the unmagnetized work of Drake et al., Phys. Fluids 17, 778 (1974). For this, we use a multi-species plasma fluid model and Maxwell's equations. The application of an external B field causes right- and left-polarized light waves to propagate with differing phase velocities. This leads to Faraday rotation of the polarization, which can be significant in HED conditions. Phase-matching and linear wave dispersion relations show that Raman and Brillouin scattering have modified spectra due to the background B field, though this effect is usually small in systems of current practical interest. We study a scattering process we call stimulated whistler scattering, where a light wave decays to an electromagnetic whistler wave (ω≲ω ce ) and a Langmuir wave. This only occurs in the presence of an external B field, which is required for the whistler wave to exist.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers

A design of an Active Magnetic Regenerative Refrigeration (AMRR) system has been developed for space applications. It uses an innovative 3He cryogenic circulator to provide continuous remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. A critical component technology for this cooling system is a highly efficient active magnetic regenerator, which is a regenerative heat exchanger with its matrix material made of magnetic refrigerant gadolinium gallium garnet (GGG). Creare Inc. is developing a microchannel GGG regenerator with an anisotropic structured bed for high system thermal efficiency. The regenerator core consists of a stack of thin, single-crystal GGG disks alternating with thin polymer insulating layers. The insulating layers help minimize the axial conduction heat leak, since GGG has a very high thermal conductivity in the regenerator s operating temperature range. The GGG disks contain micro channels with width near 100 micrometers, which enhance the heat transfer between the circulating flow and the refrigerant bed. The unique flow configuration of the GGG plates ensures a uniform flow distribution across the plates. The main fabrication challenges for the regenerator are the machining of high-aspect-ratio microchannels in fragile, single-crystal GGG disks and fabrication and assembly of the GGG insulation layers. Feasibility demonstrations to date include use of an ultrashort- pulse laser to machine microchannels without producing unacceptable microcracking or deposition of recast material, as shown in the figure, and attachment of a thin insulation layer to a GGG disk without obstructing the flow paths. At the time of this reporting, efforts were focused on improving the laser machining process to increase machining speed and further reduce microcracking.

Chen, Weibo↗

Wireless sensing and control of temperature using magnetic fields

A method and system for sensing and controlling temperature with magnetic fields are provided. The method comprises placing a compound in thermal communication with a number of temperature or heat sources and placing a number of magnets in thermal communication with the compound. A number of magnetic sensors are placed in electromagnetic communication with the number of magnets. Changes in the magnetic field of the magnets are detected by the sensors and used to determine the temperature of the compound according to a model that maps magnetic field characteristics to temperature. The amount of cure of the compound can then be estimated from the temperature. The temperature or heat sources are controlled in response to the temperature measurement and the estimated amount of cure of the compound.

Chen Mazumdar, Yi↗

Neutron diffraction and μ SR studies of two polymorphs of nickel niobate NiNb 2 O 6

Neutron diffraction and muon spin relaxation (μSR) studies are presented in this paper for the newly characterized polymorph of NiNb 2 O 6 (β-NiNb 2 O 6 ) with space group P4 2 /n and μSR data only for the previously known columbite structure polymorph with space group Pbcn. The magnetic structure of the P4 2 /n form was determined from neutron diffraction using both powder and single-crystal data. Powder neutron diffraction determined an ordering wave vector → k=( 1 / 2 , 1 / 2 , 1 / 2 ). Single-crystal data confirmed the same → k vector and showed that the correct magnetic structure consists of antiferromagnetically coupled chains running along the a or b axis in adjacent Ni 2+ layers perpendicular to the c axis, which is consistent with the expected exchange interaction hierarchy in this system. The refined magnetic structure is compared with the known magnetic structures of the closely related trirutile phases, NiSb 2 O 6 and NiTa 2 O 6 . μSR data finds a transition temperature of T N ~15K for this system, while the columbite polymorph exhibits a lower T N =5.7(3) K. Our μSR measurements also allowed us to estimate the critical exponent of the order parameter β for each polymorph. We found β =0.25(3) and 0.16(2) for the β and columbite polymorphs, respectively. The single-crystal neutron scattering data give a value for the critical exponent β =0.28(3) for β-NiNb 2 O 6 , in agreement with the μSR value. While both systems have β values less than 0.3, which is indicative of reduced dimensionality, this effect appears to be much stronger for the columbite system. Finally, in other words, although both systems appear to be well described by S=1 spin chains, the interchain interactions in the β polymorph are likely much larger.

36 MATERIALS SCIENCE↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis and improvement of detection accuracy for a wireless motion sensing system using integrated coil component

Integration of the exciting coil and the pick-up coil array for the wireless magnetic motion sensing system has been investigated to clear the limitation of the system arrangement. From the comparison of the integrated-type and the sandwich-type, which was proposed by our previous study, regardless of the lower signal-to-noise ratio of the integrated-type than that of the sandwich-type a repeatable detection accuracy of around 1 mm is obtained at the distance of 120 mm from the pick-up coil array (sandwich-type: up to 140 mm). A different tendency of the detection errors in detection was also observed. In spite of different tendency, the cause of the errors has been clarified. The impedance change of the exciting coil due to a resonance of the LC marker perturbs strength of the magnetic field which is used for marker excitation. However, the errors are able to compensate to the actual positions and orientations of the marker by using compensatory method which was already established.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Stability Analysis for Superconducting Coupling Coil in MICE

The superconducting coupling coil to be used in the Muon Ionization Cooling Experiment (MICE) with inner radius of 750 mm, length of 285 mm and thickness of 110.4 mm will be cooled by a pair of 1.5 W at 4.2 K cryo-coolers. When the coupling coil is powered to 210 A, it will produce about 7.3 T peak magnetic field at the conductor and it will have a stored energy of 13 MJ. A key issue for safe operation of the coupling coil is the thermal stability of the coil during a charge and discharge. The magnet and its cooling system are designed for a rapid discharge where the magnet is to be discharged in 5400 seconds. The numerical simulation for the thermal stability of the MICE coupling coil has been done using ANSYS. The analysis results show that the superconducting coupling coil has a good stability and can be charged and discharged safely.

42 ENGINEERING↗

On the convergence of the solution for a generalized Zakharov system

In this paper, we study the limit behavior of the smooth solution for the generalized Zakharov system with a magnetic field which describes the spontaneous generation of a magnetic field in a cold plasma. By showing uniform bounds of solutions for this system with suitable initial data, we prove that solution of the generalized Zakharov system converges to the solution of the nonlinear Schroedinger equation with a magnetic field.

97 MATHEMATICS AND COMPUTING↗

Optical readout of singlet fission biexcitons in a heteroacene with photoluminescence detected magnetic resonance

Molecular spin systems based on photoexcited triplet pairs formed via singlet fission (SF) are attractive as carriers of quantum information because of their potentially pure and controllable spin polarization, but developing systems that offer optical routes to readout as well as initialization is challenging. Herein, we characterize the electron spin magnetic resonance change in the photoluminescence intensity for a tailored organic molecular crystal while sweeping a microwave drive up to 10 GHz in a broadband loop structure. We observe resonant transitions for both triplet and quintet spin sublevel populations showing their optical sensitivity and revealing the zero-field parameters for each. We map the evolution of these spectra in both microwave frequency and magnetic field, producing a pattern of optically detected magnetic resonance (ODMR) peaks. Fits to these data using a suitable model suggest significant spin polarization in this system with orientation selectivity. Unusual excitation intensity dependence is also observed, which inverts the sign of the ODMR signal for the triplet features, but not for the quintet. These observations demonstrate optical detection of the spin sublevel population dictated by SF and intermolecular geometry, and highlight anisotropic and multi-scale dynamics of triplet pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-203: Investigation of 1.5T Magnetic Field Dose Effects On Organs of Different Density

Purpose: For the combined 1.5T/6MV MRI-linac system, the perpendicular magnetic field to the radiation beam results in altered radiation dose distributions. This Monte Carlo study investigates the change in dose at interfaces for common organs neighboring soft tissue. Methods: MCNP6 was used to simulate the effects of a 1.5T magnetic field when irradiating tissues with a 6 MV beam. The geometries used in this study were not necessarily anatomically representative in size in order to directly compare quantitative dose effects for each tissue at the same depths. For this purpose, a 512 cm{sup 3} cubic material was positioned at the center of a 2744 cm{sup 3} cubic soft tissue material phantom. The following tissue materials and their densities were used in this study: lung (0.296 g/cm{sup 3}), fat (0.95), spinal cord (1.038), soft tissue (1.04), muscle (1.05), eye (1.076), trabecular bone (1.40), and cortical bone (1.85). Results: The addition of a 1.5T magnetic field caused dose changes of +46.5%, +2.4%, −0.9%, −0.8%, −1.5%, −6.5%, and −8.8% at the entrance interface between soft tissue and lung, fat, spinal cord, muscle, eye, trabecular bone, and cortical bone tissues respectively. Dose changes of −39.4%, −4.1%, −0.8%, −0.8%, +0.5%, +6.7%, and +10.9% were observed at the second interface between the same tissues respectively and soft tissue. On average, the build-up distance was reduced by 0.6 cm, and a dose increase of 62.7% was observed at the exit interface between soft tissue and air of the entire phantom. Conclusion: The greatest changes in dose were observed at interfaces containing lung and bone tissues. Due to the prevalence and proximity of bony anatomy to soft tissues throughout the human body, these results encourage further examination of these tissues with anatomically representative geometries using multiple beam configurations for safe treatment using the MRI-linac system.

60 APPLIED LIFE SCIENCES↗

Liner-on-plasma system near stagnation: Stabilizing effect of a magnetic cushion

This brief communication is concerned with the adiabatic compression of a high-beta plasma by a heavy liner. Elongated cylindrical and quasi-cylindrical geometries are considered. The magnetic field in a plasma is parallel to the axis, whereas the drive field has azimuthal direction. During the liner acceleration, the most dangerous modes are axisymmetric (m = 0) modes. Near stagnation, these modes are further amplified at the inner surface, as the liner is decelerated by the isotropic pressure of a high-beta plasma. This picture, however, is not complete: due to a heat loss from the plasma core to the relatively cold liner, a zone of a strong axial magnetic field may appear between a hot, high-beta plasma and a cold liner. This magnetic cushion is backed from inside by a very high-beta plasma. The stability of such a system with respect to m = 0 modes is studied and the conclusion is drawn that the stabilizing effect of the magnetic cushion remains strong even for relatively thin cushions and moderate magnetic fields in them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commensurate and incommensurate states of a spin density wave in a quasi-two-dimensional system with an anisotropic energy spectrum in an external magnetic field of arbitrary direction relative to magnetization

A theory of thermodynamic properties of a spin density wave (SDW) in a quasi-two-dimensional system (with a preset impurity concentration x) is constructed. We choose an anisotropic dispersion relation for the electron energy and assume that external magnetic field H has an arbitrary direction relative to magnetic moment M{sub Q}. The system of equations defining order parameters M{sub Q}{sup z}, M{sub Q}{sup {sigma}}, M{sub z}, and M{sup {sigma}} is constructed and transformed with allowance for the Umklapp processes. Special cases when H Double-Vertical-Line M{sub Q} and H Up-Tack M{sub Q} (H{sub Z}H{sup {sigma}} = 0) are considered in detail as well as cases of weak fields H of arbitrary direction. The condition for the transition of the system to the commensurate and incommensurate states of the SDW is analyzed. The concentration dependence of magnetic transition temperature T{sub M} is calculated, and the components of the order parameter for the incommensurate phase are determined. The phase diagram (T,{approx}x) is constructed. The effect of the magnetic field on magnetic transition temperature T{sub M} is analyzed for H{sub Z}H{sup {sigma}} = 0, and longitudinal magnetic susceptibility {chi} Double-Vertical-Line is calculated; this quantity demonstrates the temperature dependence corresponding to a system with a gap for x < x{sub c} and to a gapless state for x > x{sub c}. In the immediate vicinity of the critical impurity concentration (x {approx} x{sub c}), the temperature dependence of the magnetic susceptibility acquires a local maximum. The effect of anisotropy of the electron energy spectrum on the investigated physical quantities is also analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Voltage-controlled interlayer coupling in perpendicularly magnetized magnetic tunnel junctions

Magnetic interlayer coupling is one of the central phenomena in spintronics. It has been predicted that the sign of interlayer coupling can be manipulated by electric fields, instead of electric currents, thereby offering a promising low energy magnetization switching mechanism. Here we present the experimental demonstration of voltage-controlled interlayer coupling in a new perpendicular magnetic tunnel junction system with a GdO x tunnel barrier, where a large perpendicular magnetic anisotropy and a sizable tunnelling magnetoresistance have been achieved at room temperature. Owing to the interfacial nature of the magnetism, the ability to move oxygen vacancies within the barrier, and a large proximity-induced magnetization of GdO x , both the magnitude and the sign of the interlayer coupling in these junctions can be directly controlled by voltage. Lastly, these results pave a new path towards achieving energy-efficient magnetization switching by controlling interlayer coupling.

36 MATERIALS SCIENCE↗

Development of Electronics for Low Temperature Space Missions

The operation of electronic systems at cryogenic temperatures is anticipated for many future NASA space missions such as deep space probes and planetary surface exploration. For example, an unheated interplanetary probe launched to explore the rings of Saturn would reach an average temperature near Saturn of about -183 C. In addition to surviving the deep space harsh environment, electronics capable of low temperature operation would contribute to improving circuit performance, increasing system efficiency, and reducing payload development and launch costs. Terrestrial applications where components and systems must operate in low temperature environments include cryogenic instrumentation, superconducting magnetic energy storage, magnetic levitation transportation system, and arctic exploration. An on-going research and development program on low temperature electronics at the NASA Glenn Research Center focuses on the development of efficient power systems capable of surviving and exploiting the advantages of low temperature environments. Inhouse efforts include the design, fabrication, and characterization of low temperature power systems and the development of supporting technologies for low temperature operations, such as dielectric and insulating materials, semiconductor devices, passive power components, opto-electronic devices, as well as packaging and integration of the developed components into prototype flight hardware.

Patterson, Richard L.↗

Electronic Components and Systems for Cryogenic Space Applications

Electronic components and systems capable of operation at cryogenic temperatures are anticipated in many future NASA space missions such as deep space probes and planetary surface exploration. For example, an unheated interplanetary probe launched to explore the rings of Saturn would reach an average temperature near Saturn of about - 183 C. In addition to surviving the deep space harsh environment, electronics capable of low temperature operation would contribute to improving circuit performance, increasing system efficiency, and reducing payload development and launch costs. Terrestrial applications where components and systems must operate in low temperature environments include cryogenic instrumentation, superconducting magnetic energy storage, magnetic levitation transportation system, and arctic exploration. An on-going research and development program at the NASA Glenn Research Center focuses on the development of reliable electronic devices and efficient power systems capable of surviving in low temperature environments. An overview of the program will be presented in this paper. A description of the low temperature test facilities along with selected data obtained from in-house component testing will also be discussed. Ongoing research activities that are being performed in collaboration with various organizations will also be presented.

Patterson, R. L.↗

Heat flow control and segregation in directional solidification: Development of an experimental and theoretical basis for Bridgman-type growth experiments in a microgravity environment

Within the framework of the proposed research, emphasis was placed on application of magnetic fields to semiconductor growth systems. It was found that magnetic fields up to 3 kGauss do not affect the growth behavior nor the macro-segregation behavior in the system Ge(Ga). Applied fields are found to significantlty alter the radial dopant distribution, which is attributed to alterations in the spatial orientation of convective cells. Increasing the magnetic field to 30 kGauss is found to have a fundamental effect on dopant segregation. Emphasis is also placed on the potential of KC-135 flights for preliminary studies on the effects of reduced gravity environments on the wetting behavior of semiconductor systems in growth configuration. The limited number of experiments conducted does not allow any conclusions on the merits of KC-135 flights for semiconductor processing research.

Witt, A. F.↗

Refine your search to explore more results.