Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Single quantum dot emission by nanoscale selective growth of InAs on GaAs: A bottom-up approach

We report on single dot microphotoluminescence ({mu}PL) emission at low temperature and low power from InAs dots grown by molecular beam epitaxy in nanoscale holes of a SiO{sub 2} mask deposited on GaAs(001). By comparing atomic force microscopy measurements with {mu}PL data, we show that the dot sizes inside the nanoholes are smaller than those of the dots nucleated on the extended GaAs surface. PL of dots spans a wide energy range depending on their size and on the thickness and composition of the InGaAs capping layer. Time-resolved PL experiments demonstrate a negligible loss of radiative recombination efficiency, proving highly effective in the site-controlled dot nucleation.

36 MATERIALS SCIENCE↗

Localized measurement of short wavelength plasma fluctuations with the DIII-D phase contrast imaging diagnostic

A novel rotating mask system has been designed and implemented on the DIII-D phase contrast imaging (PCI) diagnostic to produce the first spatially localized PCI measurements of a tokamak plasma. The localization technique makes use of the variation in the magnetic field component perpendicular to the viewing chord as a function of chord height. This new capability provides measurements in the range of 2<k<30 cm{sup -1}, 10 kHz<f<10 MHz, and 0.7<r/a<1. This technique provides a spatial resolution of 10 cm at k=15 cm{sup -1} and can realistically provide measurements at a rate of 10 profiles/s. Calibration measurements show accurate characterization of the system transfer function making feasible a time dependent analysis that results in improved localization. Initial measurements show turbulence to peak near the plasma edge. This upgrade is part of a broader program to operate the DIII-D PCI at wave numbers up to 40 cm{sup -1} to probe electron scale turbulence in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planar patterned media fabricated by ion irradiation into CrPt{sub 3} ordered alloy films

Planar patterned media using CrPt{sub 3} ordered alloy films were fabricated by Ar{sup +} or Kr{sup +} ion irradiation through nanoimprinted or electron beam lithography made masks. CrPt{sub 3} ordered alloy film on fused quartz substrate exhibits a large perpendicular anisotropy of 5x10{sup 6} erg/cc and a large coercivity of 12 kOe, and we found that its magnetic order (magnetization) was completely suppressed by a quite low Ar{sup +} or Kr{sup +} ion dose of about 1-2x10{sup 14} ions/cm{sup 2}. Magnetic force microscope image of the ion-beam patterned CrPt{sub 3} with a bit size of 90x90 nm showed clear magnetic contrast in nonirradiated regions, while no magnetic contrast in irradiated regions. The read-back waveform taken from an ion-beam patterned CrPt{sub 3} disk with 600 nm patterning pitch showed sharp signal transition between irradiated and nonirradiated regions, which indicates the possibility of high-density planar patterned media using CrPt{sub 3} ordered alloy.

36 MATERIALS SCIENCE↗

Si substrates texturing and vapor-solid-solid Si nanowhiskers growth using pure hydrogen as source gas

Scanning and transmission electron microscopies have been used to study silicon substrate texturing and whisker growth on Si substrates using pure hydrogen source gas in a tungsten hot filament reactor. Substrate texturing, in the nanometer to micrometer range of mono- and as-cut multicrystalline silicon, was observed after deposition of WSi{sub 2} particles that acted as a mask for subsequent hydrogen radical etching. Simultaneous Si whisker growth was observed for long residence time of the source gas and low H{sub 2} flow rate with high pressure. The whiskers formed via vapor-solid-solid growth, in which the deposited WSi{sub 2} particles acted as catalysts for a subsequent metal-induced layer exchange process well below the eutectic temperature. In this process, SiH{sub x} species, formed by substrate etching by the H radicals, diffuse through the metal particles. This leads to growth of crystalline Si whiskers via metal-induced solid-phase crystallization. Transmission electron microscopy, electron diffraction, and x-ray energy dispersive spectroscopy were used to study the WSi{sub 2} particles and the structure of the Si substrates in detail. It has been established that the whiskers are partly crystalline and partly amorphous, consisting of pure Si with WSi{sub 2} particles on their tips as well as sometimes being incorporated into their structure.

36 MATERIALS SCIENCE↗

Local stress engineering of magnetic anisotropy in soft magnetic thin films

The magnetic anisotropy of amorphous thin films was modified laterally by masked ion irradiation without alteration of the intrinsic magnetic properties. The changes were introduced by local ion implantation in a protection layer, causing additional stress-induced magnetic anisotropy in the magnetostrictive layer. The underlying local variation in magnetic anisotropy was modeled and confirmed experimentally. The described method, relying purely on magnetoelastics, introduces a new path to the alteration of magnetic properties subsequent to magnetic film preparation. With the use of the resulting artificial magnetization patterns, it is possible to tailor the ferromagnetic thin film structure used in magnetoelectronic applications.

36 MATERIALS SCIENCE↗

Thermal Neutron Imaging in an Active Interrogation Environment

We have developed a thermal-neutron coded-aperture imager that reveals the locations of hydrogenous materials from which thermal neutrons are being emitted. This imaging detector can be combined with an accelerator to form an active interrogation system in which fast neutrons are produced in a heavy metal target by means of excitation by high energy photons. The photo-induced neutrons can be either prompt or delayed, depending on whether neutron-emitting fission products are generated. Provided that there are hydrogenous materials close to the target, some of the photo-induced neutrons slow down and emerge from the surface at thermal energies. These neutrons can be used to create images that show the location and shape of the thermalizing materials. Analysis of the temporal response of the neutron flux provides information about delayed neutrons from induced fission if there are fissionable materials in the target. The combination of imaging and time-of-flight discrimination helps to improve the signal-to-background ratio. It is also possible to interrogate the target with neutrons, for example using a D-T generator. In this case, an image can be obtained from hydrogenous material in a target without the presence of heavy metal. In addition, if fissionable material is present in the target, probing with fast neutrons can stimulate delayed neutrons from fission, and the imager can detect and locate the object of interest, using appropriate time gating. Operation of this sensitive detection equipment in the vicinity of an accelerator presents a number of challenges, because the accelerator emits electromagnetic interference as well as stray ionizing radiation, which can mask the signals of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Positron Spectroscopy Investigation of Normal Brain Section and Brain Section with Glioma Derived from a Rat Glioma Model

The application of positron annihilation lifetime spectroscopy (PALS) and Doppler broadening spectroscopy (DBS) to the study of animal or human tissue has only recently been reported [G. Liu, et al. phys. stat. sol. (C) 4, Nos. 10, 3912-3915 (2007)]. We have initiated a study of normal brain section and brain section with glioma derived from a rat glioma model. For the rat glioma model, 200,000 C6 cells were implanted in the basal ganglion of adult Sprague Dawley rats. The rats were sacrificed at 21 days after implantation. The brains were harvested, sliced into 2 mm thick coronal sections, and fixed in 4% formalin. PALS lifetime runs were made with the samples soaked in formalin, and there was not significant evaporation of formalin during the runs. The lifetime spectra were analyzed into two lifetime components. While early results suggested a small decrease in ortho-Positronium (o-Ps) pickoff lifetime between the normal brain section and brain section with glioma, further runs with additional samples have showed no statistically significant difference between the normal and tumor tissue for this type of tumor. The o-Ps lifetime in formalin alone was lower than either the normal tissue or glioma sample. So annihilation in the formalin absorbed in the samples would lower the o-Ps lifetime and this may have masked any difference due to the glioma itself. DBS was also used to investigate the difference in positronium formation between tumor and normal tissue. Tissue samples are heterogeneous and this needs to be carefully considered if PALS and DBS are to become useful tools in distinguishing tissue samples.

60 APPLIED LIFE SCIENCES↗

GaN-based light-emitting diode with textured indium tin oxide transparent layer coated with Al{sub 2}O{sub 3} powder

Surface-textured InGaN/GaN light-emitting diodes (LEDs) coated with transparent Al{sub 2}O{sub 3} powder were fabricated by natural lithography combined with inductively coupled plasma etching. For surface texturing, 300 nm size Al{sub 2}O{sub 3} powder is used as an etching mask by simply coating the surface using a spin-coating process. Also, the powders are left on the surface after surface texturing to further increase extraction efficiency. At 20 mA, the light output power of the textured indium tin oxide (ITO) InGaN/GaN LEDs coated with the Al{sub 2}O{sub 3} powder is enhanced by {approx}112% compared with the conventional nontextured ITO LED. The enhanced light output power is attributed to the improved extraction efficiency resulting from an overall decrease in the total internal reflection due to the textured surface and the Al{sub 2}O{sub 3} powder coating.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rapid three-dimensional imaging of defect distributions using a high-intensity positron microbeam

An intense positron microbeam generated by an electron accelerator has been developed for obtaining three-dimensional positron lifetime mappings in a sample to permit visual evaluation of defect distributions. The beam diameter at the sample was 80-100 {mu}m. The counting rate of the positron annihilation {gamma} rays used to measure positron lifetime was as large as 3x10{sup 3} s{sup -1}. Three-dimensional imaging was demonstrated of positron lifetimes in a SiO{sub 2} sample, which was irradiated with ion beams through a mesh mask. The time to obtain a single image (3500 pixels for an area of 2.5x3.5 mm{sup 2}) was 0.5-1 h.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Light and Effective Wide Field Monitor for Gamma Ray Bursts and Transient Sources

We present here a concept for a light and low-power wide field monitor working in the X-ray range, suitable for simultaneous imaging of large portions of the sky and GRB localizations. Our concept evolves from and improves on the design of the 5-kg SuperAGILE experiment, flying on the AGILE mission and currently delivering arcmin-localizations of GRBs at a rate of about 1/month. Similar to SuperAGILE, our concept is based on position sensitive silicon detectors equipped with one-dimensional coded masks. Different options are available for the detector, whose properties, combined with the scientific requirements, drive the design of the experiment. Our approach is based on a modular detector. The experiment design can then be tailored to specific scientific goals of the experiment or the mission (e.g., to cite GRBs only: the brightest GRBs/XRFs on a large field of view - FoV, or many low-fluence GRBs/XRFs on a smaller FoV, or the low energy spectrum of the prompt event, or the detection of high-z GRBs). In this paper we describe the concept, the main detector properties and outline some possible experiment configurations, with examples of their expected performance. Different experiment configurations in terms of area, FoV, angular resolution may be designed starting from the same detectors. Instead, the band-pass is mostly related to the detector properties. A key point of our project is the high degree of readiness of the detectors that are at production level and may be immediately proposed for a future experiment onboard missions with high readiness requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of gold patterning on the bending profile and frequency response of a microcantilever

We have systematically investigated the effect of various gold patterns on the bending profile and frequency response of a microcantilever. The gold patterns were deposited on the cantilever arrays using four types of shadow mask. The local bending profile, slope, and curvature varied depending on the area and position of the gold pattern. Also, the variations in the first three modes of the flexural resonance frequencies of the gold patterned cantilevers were measured to understand the opposing effects of mass loading and flexural rigidity; both of these parameters are dependent on the position and area of the gold pattern. The experimental results validated the theoretical one-dimensional model introduced by Tamayo et al. Appl. Phys. Lett. 89, 224104 2006 and our calculations using the finite element method. The gold patterns giving the maximum response of the mass loading and flexural rigidity change were determined by examining how the relative resonance frequency shifts as a function of the distance of the gold coating from the free end or clamping region. The results of this study can potentially be applied in the design of a microcantilever sensor in which pattern analysis is utilized to determine the presence of adsorbed biological and chemical molecules.

42 ENGINEERING↗

Nanophotonic technologies for innovative all- optical signal processor using photonic crystals and quantum dots

GaAs-based two-dimensional photonic crystal (2DPC) slab waveguides (WGs) and InAs quantum dots (QDs) were developed for key photonic device structures in the future. An ultrasmall and ultrafast symmetrical Mach-Zehnder (SMZ)-type all-optical switch (PC-SMZ) and an optical flip-flop device (PC-FF) have been developed based on these nanophotonic structures for an ultrafast digital photonic network. To realize these devices, two important techniques were developed. One is a new simulation method, i.e., topology optimization method of 2DPC WGs with wide/flat bandwidth, high transmittance and low reflectivity. Another is a new selective-area-growth method, i.e., metal-mask molecular beam epitaxy method of InAs QDs. This technique contributes to achieving high-density and highly uniform InAs QDs in a desired area such as an optical nonlinearity-induced phase shift arm in the PC-FF. Furthermore, as a unique site-controlled QD technique, a nano-jet probe method is also developed for positioning QDs at the centre of the optical nonlinearity-induced phase shift arm.

36 MATERIALS SCIENCE↗

Defect reduction in epitaxial GaSb grown on nanopatterned GaAs substrates using full wafer block copolymer lithography

Defect reduction in the large lattice mismatched system of GaSb on GaAs, {approx}7%, was accomplished using full wafer block copolymer (BCP) lithography. A self-assembled BCP mask layer was used to generate a hexagonal pattern of {approx}20 nm holes on {approx}40 nm centers in a 20 nm SiO{sub 2} layer. GaSb growth initially takes place selectively within these holes leading to a dense array of small, strain-relaxed epitaxial GaSb islands. The GaSb grown on the patterned SiO{sub 2} layer exhibits a reduction in the x-ray linewidth attributed to a decrease in the threading dislocation density when compared to blanket pseudomorphic film growth.

36 MATERIALS SCIENCE↗

Improved model for the angular dependence of excimer laser ablation rates in polymer materials

Measurements of the angle-dependent ablation rates of polymers that have applications in microdevice fabrication are reported. A simple model based on Beer's law, including plume absorption, is shown to give good agreement with the experimental findings for polycarbonate and SU8, ablated using the 193 and 248 nm excimer lasers, respectively. The modeling forms a useful tool for designing masks needed to fabricate complex surface relief by ablation.

36 MATERIALS SCIENCE↗

Portable emittance measurement device

In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.

43 PARTICLE ACCELERATORS↗

Formation of conical silicon tips with nanoscale sharpness by localized laser irradiation

The formation of conical silicon tips with nanoscale sharpness as a result of single-pulse localized laser irradiation is presented in this work. A Q-switched neodymium doped yttrium aluminum garnet nanosecond-pulse laser, emitting at its fourth harmonic of 266 nm, and a mask projection technique were used to generate circular laser spots, several microns in diameter. The irradiation of silicon-on-insulator films was performed in ambient, vacuum, or argon atmospheres, with the resulting structures and underlying substrate examined via atomic force microscopy and scanning electron microscopy. The laser fluence range within which tip formation occurs is strongly dependent on the irradiated spot size. Within this range, the height of the resulting tip increases with the fluence level, while nearly preserving the aspect ratio. The formation mechanism of these structures is briefly discussed in view of these results and other, related published work.

36 MATERIALS SCIENCE↗

A heterodyne interferometer for angle metrology

We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/{radical}(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately {+-}0.15 mrad, and 3 {mu}rad rms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dislocation reduction via selective-area growth of InN accompanied by lateral growth by rf-plasma-assisted molecular-beam epitaxy

We investigated the selective-area growth (SAG) of InN by rf-plasma-assisted molecular-beam epitaxy using molybdenum (Mo)-mask-patterned sapphire (0001) substrates, which resulted in the formation of regularly arranged N-polar InN microcrystals. Transmission electron microscopy observation confirmed that the laterally grown side areas were nearly dislocation-free, although many threading dislocations (10{sup 9}-10{sup 10} cm{sup -2}) were generated at the InN/sapphire interface and propagated into the center of the InN microcrystals along the crystal c-axis. The laterally grown InN microcrystals exhibited narrow near-IR emission spectra with a peak photon energy of 0.627 eV and a linewidth of 39 meV at room temperature.

36 MATERIALS SCIENCE↗

Refine your search to explore more results.