Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

TuFF internal WRAP for Rapid Pipeline Repair (TuFF iWRAP)

The goal of “TuFF internal WRAP for Rapid Pipeline Repair” (TuFF iWRAP) program was to develop a novel material system and placement process to fabricate structural pipe within the existing deteriorated pipelines without disruption of gas delivery. The team (University of Delaware – Center for Composite Materials (UD-CCM) and Plitzie Inc.) addressed this challenge by developing a new material feedstock and pipe in pipe (PIP) repair strategy. This allows the potential for significant cost reduction and has minimum operational impact on gas customers. The new robotic based placement design allows discontinuous placement of pipe sections creating a stand-alone structural liner within the legacy pipeline without the need for pipe shutdown. Here, the material is supplied using a tethered material feeding system and is placed and UV cured with the internal Wound Rapid Automated Placement (iWRAP) system. This provides maximum placement efficiency capable of traversing 90 angle bends in 12-inch pipe and overall design customization to meet pipe repair requirements (e.g., variable wall thickness, bridging gaps, etc.). UV-curable fiber reinforced composite material has been optimized to meet structural performance and placement/cure times. Superior strength and fatigue life has been demonstrated by improving fiber-matrix adhesion using new fiber sizing for UV resins. Rapid cure approaches using new liner and resins have been evaluated with industry. The appropriate design of the section joints has been developed and tested. We estimate coating time to be ~100 hours per mile enabling typical pipe repair within 1 week.

03 NATURAL GAS↗

Engineering Evaluation Report on K-311-1 Floor Subsidence (2008 Annual Report) at the East Tennessee Technology Park, Oak Ridge, Tennessee

The purpose of this task is to evaluate the effect of floor settlement on building structure, piping, and equipment foundations between column lines 1 and 2 and B and K of Bldg. K-311-1 (see Fig. A-1 in Appendix A) at East Tennessee Technology Park (ETTP), Oak Ridge, Tennessee. Revision 0 of this document covers the 2005 annual inspection. Revision 1 addresses the 2006 annual inspection, Revision 2 addresses the 2007 annual inspection, and Revision 3 covers the 2008 annual inspection, as indicated by the changed report title. A civil survey and visual inspection were performed. Only a representative number of points were measured during the 2008 survey. The exact location of a number of survey points in Table A-1 could not be accurately determined in the 2008 survey since these points had not been spray painted since 2003. The points measured are deemed adequate to support the conclusions of this report. Based on the survey and observations, there has been no appreciable change in the condition of the unit since the 2007 inspection. The subsidence of the floor presents concerns to the building structure due to the possible indeterminate load on the pipe gallery framing. Prior to demolition activities that involve the piping or removal of the equipment, such as vent, purge and drain and foaming, engineering involvement in the planning is necessary. The piping connected to the equipment is under stress, and actions should be implemented to relieve this stress prior to disturbing any of the equipment or associated piping. In addition, the load on the pipe gallery framing needs to be relieved prior to any activities taking place in the pipe gallery. Access to this area and the pipe gallery is not allowed until the stress is released.

54 ENVIRONMENTAL SCIENCES↗

High temperature thermal energy storage in steel and sand

The technical and economic potential for high temperature (343 C, 650 F) thermal energy storage in hollow steel ingots, pipes embedded in concrete, and for pipes buried in sand was evaluated. Because it was determined that concrete would separate from pipes due to thermal stresses, concrete was replaced by sand, which is free from thermal stresses. Variations of the steel ingot concept were not cost effective compared to the sand-pipe approach, therefore, the sand-pipe thermal storage unit (TSU) was evaluated in depth to assess the approximate tube spacing requirements consistent with different system performance characteristics and also attendant system costs. For large TSUs which do not require fast response times, the sand-pipe approach offers attractive possibilities. A pipe diameter about 9 cm (3.5 in) and pipe spacing of approximately 25 cm (10 in), with sand filling the interspaces, appears appropriate. Such a TSU system designed for 8 hours charge/discharge cycle has an energy unit storage cost (CE) of $2.63/kWhr-t and a power unit storage cost (Cp) of $42/kW-t (in 1977 dollars).

Turner, R. H.↗

Spaceborne power systems preference analyses. Volume 2: Decision analysis

Sixteen alternative spaceborne nuclear power system concepts were ranked using multiattribute decision analysis. The purpose of the ranking was to identify promising concepts for further technology development and the issues associated with such development. Four groups were interviewed to obtain preference. The four groups were: safety, systems definition and design, technology assessment, and mission analysis. The highest ranked systems were the heat-pipe thermoelectric systems, heat-pipe Stirling, in-core thermionic, and liquid-metal thermoelectric systems. The next group contained the liquid-metal Stirling, heat-pipe Alkali Metal Thermoelectric Converter (AMTEC), heat-pipe Brayton, liquid-metal out-of-core thermionic, and heat-pipe Rankine systems. The least preferred systems were the liquid-metal AMTEC, heat-pipe thermophotovoltaic, liquid-metal Brayton and Rankine, and gas-cooled Brayton. The three nonheat-pipe technologies selected matched the top three nonheat-pipe systems ranked by this study.

Smith, J. H.↗

Valve malfunction detection apparatus

A detection system is provided for sensing a malfunction of a valve having an outlet connected to an end of a first pipe through which pressurized fluid may be flowed in a downstream direction away from the valve. The system includes a bypass pipe connected at its opposite ends to the first pipe and operative to bypass a portion of the fluid flow therethrough around a predetermined section thereof. A housing is interiorly divided by a flexible diaphragm into first and second opposite chambers which are respectively communicated with the first pipe section and the bypass pipe, the diaphragm being spring-biased toward the second chamber. The diaphragm housing cooperates with check valves and orifices connected in the two pipes to create and maintain a negative pressure in the first pipe section in response to closure of the valve during pressurized flow through the first pipe. A pressure switch senses the negative pressure and transmits a signal indicative thereof to a computer. Upon cessation of the signal while the valve is still closed, the computer responsively generates a signal indicating that the valve, or another portion of the detection system, is leaking.

Burley, Richard K.↗

Controllable Multi-Functional Heat Exchanger for Space Applications

Team Spacering will design SpaceRing, a cooling and waste heat recycling system that addresses NASA’s interest for a cooling and power-generating unit in its prototype deep space habitat[1]. The merits of this system are as follows: - Controllable cooling is critical in maintaining a habitable environment and in the functionality of life support systems, powering electronics and other devices in a spacecraft. - Power is expensive to produce in a space environment. Converting wasted thermal energy into electricity will save energy and money for the space station. Space habitation is a highly complex endeavor. Consequently, the SpaceRing must adhere to additional constraints, which include: - Lack of natural fluid or gas convection due to micro-gravity environment - Limited range for heat source and cold sink temperature - Subject to high fluctuations of incoming thermal energy - Minimal weight due to the high cost of transporting items into space After consulting with NASA and experts in thermal studies, several design objectives were identified and are listed below in order of importance: - High cooling capacity - Reliable safety control and alert system - Maximization of energy generation from wasted heat - Optimization of cooling capability and power generation - Long operational life and minimization of maintenance In space, conventional cooling systems utilize passive heat pipe systems for small-scale heat rejection and pumped pipes with heat exchangers for large-scale heat rejection. Thermal power generation in space is mainly achieved by using thermoelectric material that produces electric energy from temperature differentials. We propose a design that combines cooling and thermoelectric power generation. Using a hot pipe connected to a heat source, a cold pipe connected to a radiator, a heat exchanger in contact with both pipes, and a pump in each pipe to move the fluid, we make an active cooling system. The thermoelectric material is inserted in the heat exchanger between the hot and cold pipes to extract energy from the maximum temperature difference coming from the two pipes. It also provides controllable cooling capacity through the use of the thermoelectric material as cooling modules. We have tested our system under target heat source and sink conditions and measured the temperatures and flow rates. Our preliminary results are promising, demonstrating the output of 25 Watts of power on average. We are in the process of running control tests to compare the heat transfer performance without the thermoelectric generators, which is vital in determining whether or not the generators introduce an unacceptable amount of thermal resistance. While some control tests have been run already, the results have been noisy. We have modified our testing environment and data acquisition methods to allow for simple comparison between the control test results and thermoelectric performance results. Lastly, we have modified the heat exchanger design slightly to include acrylic baffles. This will allow the heat to flow through the heat exchanger more efficiently. We have presented our preliminary results to NASA and will deliver the final product by the end of May 2014.

Lee Xiong↗

Low pressure drop advanced swirl technology gas filter

A media-free filter device for a supercritical fluid process is disclosed. The media-free filter device includes a first pipe section connected in flow communication with a closed-loop system for a supercritical fluid. A y-pipe segment intersects the first pipe section at an intersection joint. The intersection joint intersects at a descending obtuse angle with respect to the first pipe section flow direction. The y-pipe segment is open at the intersection joint and closed opposite the intersection joint, in flow communication with the first pipe section. The y-pipe section induces an eddy current turbulence zone adjacent the intersection joint to remove substantially all contaminants suspended in the supercritical fluid; and the contaminants are deposited in the descending y-pipe segment. An SCO2 process incorporating the media-free filter device is also disclosed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Establishing no credible risk of inadvertent criticality for the K-25 demolition project - 14310

Demolition of the K-25 Gaseous Diffusion Plant required establishing a non-credible risk of inadvertent criticality because a Criticality Accident Alarm System (CAAS) could not be reliably maintained operable as the building was being torn down. Preparation for, and demolition of, the facility was a multi-year long effort with significant changes in approach. The most significant change was to demolish the facility with as much of the process gas equipment and piping left in the facility as possible, rather than removing all process gas equipment and piping from the facility prior to demolishing the building structure only. The contractor had to adapt their approach to accommodate these changes. The normal approach to demolition was to remove all process gas equipment and piping prior to demolition, using Nuclear Criticality Safety (NCS) controls based on the double contingency principle, while CAAS coverage was intact. Then, the building structure was demolished with no requirement for a CAAS. This was the method used to demolish the K-33 Building, for example. In the case of K-25 demolition, all equipment and piping that met the Environmental Management Waste Management Facility (EMWMF) disposal cell Waste Acceptance Criteria (WAC) was left in the building and removed as part of the building demolition process. This resulted in significant quantities of fissionable material remaining in the building and being handled during demolition. The NCS Organization worked closely with several groups during preparation activities. A Data Management organization was established to specifically identify every piece of process gas equipment and piping in the facility so that it could be accounted for and characterized. Deactivation and Decommissioning (D and D) personnel conducted internal visual inspections, by remote camera, of all process gas equipment and piping larger than 3' diameter, to reveal any large deposits that would require removal. Non-Destructive Assay (NDA) of the vast majority of equipment and piping was required to quantify the amount of fissionable material remaining. Finally, all process gas equipment and piping larger than 3'' diameter was internally filled with foam, which was credited by NCS with immobilizing the remaining fissionable material such that large migration and accumulation could not occur during demolition activities. NCS personnel worked closely with all of these groups in order to acquire the data and information needed to establish a non-credible risk of inadvertent criticality during building demolition. Good communication and a close working relationship between NCS, the various D and D/characterization personnel, and the Department of Energy (DOE) ensured the success of the modified approach to building demolition. The same successful approach is currently underway in the K-27 Building as well. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acoustic system for communication in pipelines

A system for communication in a pipe, or pipeline, or network of pipes containing a fluid. The system includes an encoding and transmitting sub-system connected to the pipe, or pipeline, or network of pipes that transmits a signal in the frequency range of 3-100 kHz into the pipe, or pipeline, or network of pipes containing a fluid, and a receiver and processor sub-system connected to the pipe, or pipeline, or network of pipes containing a fluid that receives said signal and uses said signal for a desired application.

47 OTHER INSTRUMENTATION↗

Leveraging MARVEL and SPHERE to Demonstrate NEAMS Thermal Hydraulics Codes

The Single Primary Heat Extraction and Removal Emulator (SPHERE) and Microreactor Applications Research Validation and Evaluation (MARVEL) were utilized to demonstrate thermal hydraulics codes of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. A recent long-duration test of a sodium heat pipe conducted at the SPHERE facility was utilized for the validation of the heat pipe code Sockeye. The first 10 hours of operation featured a startup of the heat pipe from room temperature; this portion was modeled with Sockeye and compared to the experimental data. Measurements included several thermocouple measurements across the length of the heat pipe surface. Two of Sockeye’s heat pipe models were applied to experiment, as well as several models of the cooling at the condenser end of the heat pipe. Sockeye results gave a decent match to the experimental data, with notable discrepancy in the condenser section, where experimental data indicated a significant inactive length of the heat pipe. The MARVEL microreactor was modeled through a coupled simulation of System Analysis Module (SAM) and SubChannel Module (SCM). This multiscale coupled simulation was performed as an exercise to demonstrate the compatibility and applicability of these codes for thermal-hydraulic analysis of microreactors. The coupling between the SCM and SAM codes for multiscale modeling of MARVEL, was achieved through a domain overlapping approach. In this example a transient SAM simulation provided boundary conditions to SCM, and SCM provided pressure drop to SAM.

97 - MATHEMATICS AND COMPUTING↗

Status of the Development of Low Cost Radiator for Surface Fission Power - II

NASA Glenn Research Center (GRC) is developing fission power system technology for future Lunar and Martian surface power applications. The systems are envisioned in the 10 to 100kWe range and have an anticipated design life of 8 to 15 years with no maintenance. NASA GRC is currently setting up a 55 kWe non-nuclear system ground test in thermal-vacuum to validate technologies required to transfer reactor heat, convert the heat into electricity, reject waste heat, process the electrical output, and demonstrate overall system performance. The paper reports on the development of the heat pipe radiator to reject the waste heat from the Stirling convertors. Reducing the radiator mass, size, and cost is essential to the success of the program. To meet these goals, Advanced Cooling Technologies, Inc. (ACT) and Vanguard Space Technologies, Inc. (VST) are developing a single facesheet radiator with heat pipes directly bonded to the facesheet. The facesheet material is a graphite fiber reinforced composite (GFRC) and the heat pipes are titanium/water Variable Conductance Heat Pipes (VCHPs). By directly bonding a single facesheet to the heat pipes, several heavy and expensive components can be eliminated from the traditional radiator design such as, POCO"TM" foam saddles, aluminum honeycomb, and a second facesheet. As mentioned in previous papers by the authors, the final design of the waste heat radiator is described as being modular with independent GFRC panels for each heat pipe. The present paper reports on test results for a single radiator module as well as a radiator cluster consisting of eight integral modules. These tests were carried out in both ambient and vacuum conditions. While the vacuum testing of the single radiator module was performed in the ACT's vacuum chamber, the vacuum testing of the eight heat pipe radiator cluster took place in NASA GRC's vacuum chamber to accommodate the larger size of the cluster. The results for both articles show good agreement with the predictions and are presented in the paper.

Surface Fission Power↗

The development and initial testing of the Ice Pig cleaning method for nuclear reprocessing plants - 15363

There are numerous situations throughout the nuclear industry where it would be advantageous to clean out enclosed systems, e.g. ducts and pipes, to remove sediments and radioactive contamination. However, conventional flushing methods result in the production of significant volumes of contaminated liquor. The wall Shear achieved with water flushing is insufficient to remove and carry dense deposits often found in nuclear facilities. Conventional mechanical pigs can be propelled through the duct by application of a driving medium such as compressed air or water. These are able to achieve very high wall shears, but can also get physically stuck where there is variation in the pipe / duct diameter or small radius bends. The field of application is best suited to straight constant diameter systems with no discontinuities such as Tee pieces, valves and in-pipe instrumentation. Driven by the desire to clean and displace radioactive materials from complex topology ducts and pipes, without the risk of having conventional pigs becoming lodged in a plant and coupled with the need to minimize effluent volumes, the UK Nuclear Industry led by Sellafield Limited (on behalf of the UK Nuclear Decommissioning Authority), has worked to demonstrate and underpin the use of the ice pigging technology for the nuclear industry. It is found that high ice fraction slurries flow as viscous liquids that exhibit a number of mechanical properties that offer much higher shear rates. The 'Ice Pig' exerts shear rates on pipe walls which are typically 1000 times greater than those achieved with water flowing at the same velocity. The 'Ice Pig' is able to negotiate almost any topology, flow through pipe networks of vastly differing diameter, through heat exchangers and in-line instrumentation etc. Experimental data and operational experience from other industries demonstrates that whilst there is high shear, the 'Ice Pig' does not damage the surface of the pipe wall. A further attractive characteristic of the 'Ice Pig' is that it eventually melts rendering it a simple effluent for processing by downstream processes. Due to the special nature of ice slurry, its unique rheological and physical characteristics, together with the complementary underpinning experimental work undertaken by Sellafield Limited enables the Ice Pigging process to move from an 'interesting' technology to one suitable for use by the nuclear industry for operations, Post Operational Clean Out (POCO) and decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hardened Containment Vent System Dose Considerations for FLEX

Fukushima lessons learned include adding diverse and flexible mitigation strategies, or FLEX, that will increase defense-in-depth for beyond-design-basis (BDB) scenarios to address an Extended Loss of AC Power (ELAP). FLEX and NRC order EA-13-109 require improvements to the reliability of Hardened Containment Vent Systems (HCVS) for Mark I and II boiling water reactors (BWR) for venting of the core under severe accident conditions. NEI HCVSWP-02 provides generic guidance to determine radiological dose from HCVS piping. This paper presents a more refined analysis tool and method to assess the doses from the HCVS piping resulting from a failed core during an ELAP for a representative Mark I BWR. The dose rates up to 4' from the HCVS pipe at 8 hours after ELAP and over time at 3' are provided for the different cases. HCVS pipe length can affect dose rates farther from the pipe. As expected, dose rates versus time for representative plant case 2 drop off quickly as the HCVS activity is vented out. The dose rate results show that significant protection for personnel would be required in the areas near HCVS piping during certain time frames of containment venting. Equipment in the vicinity of the vent piping should also be evaluated for impact of radiation exposure. The results for the representative plant cases are higher and lower than the scaled NEI results depending on the model assumptions, limitations and considerations which can change as the HCVS design evolves. Using the NEI paper with scaling factors may not be conservative for all applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examining Two-Phase Flow with Optical Sensors

In lieu of the events that occurred at Fukushima in 2011, passive safety shutdowns for nuclear reactors has become a focus area for recent research. At Argonne National Laboratory this research has been simulated using air as a means of cooling down a experimental reactor core. This operates on the principals of natural convection and can be further studied in the report devised by Lisowski et al. in 2014. The air reactor cavity cooling system (RCCS) at Argonne National Laboratory is currently being transitioned into a water cooled system for passive safety reactor shutdown systems. In this system eight water pipes (1.5'' schedule 160 stainless steel) will transfer heat by means of natural convection. However, the primary network pipe will be 4 inch schedule 40 stainless steel pipe. The adiabatic chimney portion of this piping segment will be under analysis for void fraction. Based on the internal temperature of the water pipes, the characteristic regimes of two-phase flow that could exist inside of the pipe are an area of interest for experimental analysis. Determining which phase the water exists is instrumental to understanding the state of the processes inside of the water cooling pipe. Knowledge of these states allows for analysis of the efficiency of the RCCS as it shuts down. The state of two-phase flow can be measured by the analysis of the fluids void fraction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Single Primary Heat Extraction and Removal Emulator (SPHERE) Long Duration Testing

For the development of heat-pipe cooled microreactors, it is crucial to thoroughly understand the characteristics and functioning of heat pipes across a wide spectrum of operating conditions. Passive heat removal and its long-term performance stability are critical factors in this context. Enhanced experimental data is vital for evaluating the operational lifespan of alkali metal heat pipes. Idaho National Laboratory (INL) has successfully conducted an extended duration test on a high-performance sodium-filled heat pipe, closely monitoring the axial temperature profile, power supplied by the heaters, and heat removed by a gas-gap calorimeter. The results from this testing provide valuable data that are instrumental in supporting heat pipe validation efforts. Specifically, this data aids in the development and validation of Sockeye, the Multiphysics Object-Oriented Simulation Environment (MOOSE) tool under the US-DOE NEAMS program designed for heat pipe modeling. By comparing experimental results with Sockeye’s predictions, the tool's accuracy and reliability can be assessed and improved, thereby enhancing its capability to simulate heat pipe operations under various conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiple Mechanisms of Uranium Immobilization by Cellulomonas sp. Strain ES6

Removal of hexavalent uranium (U(VI)) from aqueous solution was studied using a Gram-positive facultative anaerobe, Cellulomonas sp. strain ES6, under anaerobic, non-growth conditions in bicarbonate and PIPES buffers. Inorganic phosphate was released by cells during the experiments providing ligands for formation of insoluble U(VI) phosphates. Phosphate release was most probably the result of anaerobic hydrolysis of intracellular polyphosphates accumulated by ES6 during aerobic growth. Microbial reduction of U(VI) to U(IV) was also observed. However, the relative magnitudes of U(VI) removal by abiotic (phosphate-based) precipitation and microbial reduction depended on the buffer chemistry. In bicarbonate buffer, X-ray absorption fine structure (XAFS) spectroscopy showed that U in the solid phase was present primarily as a non-uraninite U(IV) phase, whereas in PIPES buffer, U precipitates consisted primarily of U(VI)-phosphate. In both bicarbonate and PIPES buffer, net release of cellular phosphate was measured to be lower than that observed in U-free controls suggesting simultaneous precipitation of U and PO3-4 . In PIPES, U(VI) phosphates formed a significant portion of U precipitates and mass balance estimates of U and P along with XAFS data corroborate this hypothesis. High-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (EDS) of samples from PIPES treatments indeed showed both extracellular and intracellular accumulation of U solids with nanometer sized lath structures that contained U and P. In bicarbonate, however, more phosphate was removed than required to stoichiometrically balance the U(VI)/U(IV) fraction determined by XAFS, suggesting that U(IV) precipitated together with phosphate in this system. When anthraquinone-2,6-disulfonate (AQDS), a known electron shuttle, was added to the experimental reactors, the dominant removal mechanism in both buffers was reduction to a non-uraninite U(IV) phase. Uranium immobilization by abiotic precipitation or microbial reduction has been extensively reported; however, the present work suggests that strain ES6 can remove U(VI) from solution simultaneously through precipitation with phosphate ligands and microbial reduction, depending on the environmental conditions. Cellulomonadaceae are environmentally relevant subsurface bacteria and here, for the first time, the presence of multiple U immobilization mechanisms within one organism is reported using Cellulomonas sp. strain ES6.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of two concrete thermal energy storage system configurations for continuous power production

Two Modelica concrete thermal energy storage (CTES) models are built to analyze potential CTES system designs. One design is the single pipe network design wherein a heat transfer fluid (HTF) flows in one direction during heat deposition and the opposite direction during heat removal. All pipes in the network are used for either deposition (charging) or removal (discharging). The second design is a dual pipe network design in which a network of HTF pipes carries charging fluid and a separate piping network carries discharging HTF. Operation of these two configurations to produce constant steam is evaluated. Here, results indicate that the designs are likely appropriate for different applications with the single pipe network appearing appropriate for batch energy applications and the dual pipe network for continuous energy applications.

25 ENERGY STORAGE↗

Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the 235 U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires uncertainty «1%. Accounting for material self-shielding properties, pipe thickness, and source-detector orientation is instrumental in determining the robustness of gamma-ray detection in the process monitoring of uranyl nitrate in NUCPs. Monte Carlo models and ray-tracing models were employed to determine the sensitivity of the detected 185.7 keV photon to self-shielding properties, pipe thickness, and source-detector geometry. Considering the implementation of the detection of 1 SQ, diversion of 1 SQ becomes essentially undetectable given the systematic uncertainty, in addition to considerations such as propagating uncertainties due to pipe offset/position, as well as minor variations in pipe thickness. Consequently, pipe thickness was the most sensitive variable in affecting full energy efficiency of the 185.7 keV signature peak with up to 8% variation in efficiency for ±0.5 mm changes in Schedule 40 304L stainless steel piping. Furthermore, computation of the attenuation correction factor of the uranyl nitrate solution [CF(AT) (i.e. εsample)] using Parker's method using with the approximation for the geometrical factor κ≈π/4 was validated through experimental, Monte Carlo and ray-tracing calculations for a uranyl nitrate filled transfer pipe segment. Furthermore, quantifying sensitivity in detector position, as well as voiding effects due to bubbly flow or laminar flow with an air gap in the uranyl nitrate becomes increasingly important as considerations from (static) design-scale measurements translate into (dynamic) field operations tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refine your search to explore more results.