Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

PLSS 2.5 Fan Design and Development

NASA is building a high fidelity prototype of an advanced portable life support system (PLSS) as part of the Advanced Exploration Systems Program. This new PLSS, designated as PLSS 2.5, will advance component technologies and systems knowledge in order to inform a future flight program. The oxygen ventilation loop of its predecessor, PLSS 2.0, is driven by a centrifugal fan developed using specifications from over five years ago. PLSS technology and system parameters have matured to the point where the existing fan will not perform adequately for the new prototype. In addition, areas of potential improvement have been identified with the existing fan that could be addressed in a new design. As a result, a new fan was designed and tested for the PLSS 2.5. The PLSS 2.5 fan is a derivative of the one used in PLSS 2.0. It uses the same basic non-metallic can around the motor, but with a larger volute and impeller to meet the higher pressure drop requirements of the PLSS 2.5 loop. This allows it to operate at rotational speeds that are matched to rolling element bearings, and which create reasonably low impeller tip speeds. Development of the fan also considered a shrouded impeller design that allows larger clearances for greater oxygen safety and better performance.

Converse, David↗

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger↗

Comparison of Physical Workload Across Eva-Simulation Analog Environments: Hybrid Space Suit Simulator and Pressurized Suit Testing

NASA conducts research, testing, and training across a variety of analog environments to support characterization of human performance during Extravehicular Activities (EVAs). Time utilizing pressurized suits in an offloaded environment is both limited and expensive, making it challenging to carry out extensive research with these suits. The Human Physiology, Performance, Protection, and Operations (H-3PO) Laboratory at NASA Johnson Space Center designed a Hybrid Space Suit Simulator (HS3) as a low-cost, workload approximator and easy access research tool to provide relevant physical and cognitive workloads during simulated EVAs. A pilot study was conducted in a 1g analog environment where six healthy subjects (3 male, 3 female) underwent simulated 5-hour EVAs in the HS3. This study used a COSMED K5 portable metabolic analyzer and a Polar H10 heart rate monitor to evaluate physical workload during the EVAs. For direct comparison, EVA tasks and timelines were modeled after a similar study conducted in pressurized suits (Mark-III spacesuit, n=3 male; small xPGS spacesuit, n=3 female) at NASA’s Active Response Gravity Offload System (ARGOS) offloaded to Lunar gravity (1/6 g). The 1g HS3 data demonstrated increased metabolic rate when compared to pressurized, Lunar-offloaded suited simulated EVAs for certain tasks including the kneeling scoop (HS3: 1194±199 BTU/hr, ARGOS: 860±170 BTU/hr, p < 0.05) and 20 lb object relocation (HS3: 1651±136 BTU/hr, ARGOS: 1048±252.8 BTU/hr, p < 0.05), but it did not demonstrate any significant differences in heart rate (p > 0.05). Other simulated EVA tasks, such as a 500 m traverse (HS3: 1431±177 BTU/hr, ARGOS: 1212±294 BTU/hr, p > 0.05), showed similar workload profiles with no significant workload differences between HS3 and ARGOS. The HS3 is a useful research tool for increasing workloads in EVA research without pressurized suits, though it may overestimate workload during certain EVA tasks when used in 1g environments.

Zachary Wusk↗

Low power high-performance radio frequency oscillator for driving ion traps

We report a simple, efficient, high voltage radio frequency (RF) generator powered by a single voltage source (1.5-7 V) to resonantly drive ion traps or other capacitive loads. Our circuit is able to deliver RF voltages > 500 V{sub p-p} at frequencies ranging from 0.1 to 10 MHz. This RF oscillator uses low-cost, commercially available components, and can be easily assembled onto a circuit board of a few cm{sup 2}. Because of its simplicity and good efficiency, this circuit is useful in applications requiring small size and low power consumption such as portable ion trap systems where the duration of operation under battery power is of concern.

43 PARTICLE ACCELERATORS↗

Portable chemical detection platform for on-site monitoring of odorant levels in natural gas

The adequate odorization of natural gas is critical to identify gas leaks and to reduce accidents. To ensure odorization, natural gas utility companies collect samples to be processed at core facilities or a trained human technician smells a diluted natural gas sample. In this work, we report a detection platform that addresses the lack of mobile solutions capable of providing quantitative analysis of mercaptans, a class of compounds used to odorize natural gas. Detailed description of the platform hardware and software components is provided. Designed to be portable, the platform hardware facilitates extraction of mercaptans from natural gas, separation of individual mercaptan species, and quantification of odorant concentration, with results reported at point-of-sampling. The software was developed to accommodate skilled users as well as minimally trained operators. Detection and quantification of six commonly used mercaptan compounds (ethyl mercaptan, dimethyl sulfide, n-propylmercaptan, isopropyl mercaptan, tert–butyl mercaptan, and tetrahydrothiophene) at typical odorizing concentrations of 0.1–5 ppm was performed using the device. We demonstrate the potential of this technology to ensure natural gas odorizing concentrations throughout distribution systems.

03 NATURAL GAS↗

Ion-Pair Proton Exchange Membrane Fuel Cells for Heavy-duty Transportation

The purpose of this project is to build a fuel cell prototype that demonstrates high temperature proton exchange membrane fuel cell technology (HT PEMFC) commercial readiness. It advances from a technology baseline established in a prior CRADA in which these same Parties collaborated during the years 2020-2024. These efforts are aligned with the intentions of the DOE Hydrogen Fuel Cell Technology Office (HFTO) L’Innovator Pilot Program. Participant observes that its US-based competitive advantage may be improved by further optimizing Laboratory inventions. This CRADA is intended to further improve National Laboratory compositions and to develop commercial HT PEMFC membrane electrode assemblies (MEAs) that perform over a range of operating temperatures and relative humidity, that generate power from both low grade and pure hydrogen, and that are resistant to air impurities. Participant’s goal is to advance the commercial competitiveness of National Laboratory technologies in fuel cell products for heavy-duty truck integrators, for stationary power generation, marine applications, and for emerging interest from commercial aviation. The Parties will collaborate on producing a HT PEMFC MEA that integrates LANL ion pair technology and Brookhaven catalyst technology. The Laboratories plan to research and develop compositions for testing and evaluation. The participant will manufacture multiple MEAs based on the Laboratory compositions and will enable selected customers to validate performance characteristics. The Laboratories will convey to Participant the methods of making the National Laboratory compositions such that Participant may reproduce and then scale Laboratory methods into commercial production. Throughout the project, the Laboratories and Participant will iteratively test and optimize the compositions of materials of the MEAs, intending to optimize characteristics such as power density and lifecycle durability. Participant’s intended customers include fuel cells for large trucks, aviation, power back up, marine, and portable power.

99 GENERAL AND MISCELLANEOUS↗

Analysis of the Dryden Wet Bulb GLobe Temperature Algorithm for White Sands Missile Range

In locations where workforce is exposed to high relative humidity and light winds, heat stress is a significant concern. Such is the case at the White Sands Missile Range in New Mexico. Heat stress is depicted by the wet bulb globe temperature, which is the official measurement used by the American Conference of Governmental Industrial Hygienists. The wet bulb globe temperature is measured by an instrument which was designed to be portable and needing routine maintenance. As an alternative form for measuring the wet bulb globe temperature, algorithms have been created to calculate the wet bulb globe temperature from basic meteorological observations. The algorithms are location dependent; therefore a specific algorithm is usually not suitable for multiple locations. Due to climatology similarities, the algorithm developed for use at the Dryden Flight Research Center was applied to data from the White Sands Missile Range. A study was performed that compared a wet bulb globe instrument to data from two Surface Atmospheric Measurement Systems that was applied to the Dryden wet bulb globe temperature algorithm. The period of study was from June to September of2009, with focus being applied from 0900 to 1800, local time. Analysis showed that the algorithm worked well, with a few exceptions. The algorithm becomes less accurate to the measurement when the dew point temperature is over 10 Celsius. Cloud cover also has a significant effect on the measured wet bulb globe temperature. The algorithm does not show red and black heat stress flags well due to shorter time scales of such events. The results of this study show that it is plausible that the Dryden Flight Research wet bulb globe temperature algorithm is compatible with the White Sands Missile Range, except for when there are increased dew point temperatures and cloud cover or precipitation. During such occasions, the wet bulb globe temperature instrument would be the preferred method of measurement. Out of the 30 dates examined, 23 fell under the category of having good accuracy.

LaQuay, Ryan Matthew↗

Compact Multi-Gas Monitor for Life Support Systems Control in Space: Evaluation Under Realistic Environmental Conditions

Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, pressure range from 3.5 to 14.7 psi, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under liquid water saturation. This paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a spacesuit portable Life support system and the analytical characterization of the optical sensors interrogated by the novel optoelectronic system. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the spacesuit, which may interfere with gas sensor readings. The paper also presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in spacesuits. The studies were conducted with the spacecraft maximum allowable concentrations for those trace gases and the calculated 8-hr. concentrations resulting from having no trace contaminant control system in the ventilation loop. Finally, a profile of temperature, pressure, humidity, and gas composition for a typical EVA mission has been defined, and the performance of sensors operated repeatedly under simulated EVA mission conditions has been studied.

Delgado, Jesus↗

Archaeological applications of laser-induced breakdown spectroscopy: an example from the Coso Volcanic Field, California, using advanced statistical signal processing analysis

Over the past quarter century, multielement chemical analysis has become a common means for attributing the provenance of archaeological materials. The Coso Volcanic Field (CVF) in California, USA, contains at least 38 high-silica rhyolite domes, many of which contain obsidian glass that has been quarried for tools by the indigenous population for more than 12,000 years. Artifacts made from CVF obsidian are found throughout the southwestern United States and geochemical sourcing of CVF obsidian has been an important tool in understanding prehistoric Native American trading patterns. Laser-induced breakdown spectroscopy (LIBS) is a simple atomic emission spectroscopic technique that has the potential for real-time man-portable chemical analysis in the field. Because LIBS is simultaneously sensitive to all elements, a single laser shot can be used to record the broadband emission spectra, which provides a ''chemical fingerprint'' of a material. Single-shot broadband LIBS spectra were collected using a commercial benchtop LIBS system for 27 obsidian samples from major sites across the CVF and four additional sites in California and western Nevada outside of CVF. Classification of the samples was performed using partial least-squares discriminant analysis (PLSDA), a common chemometric technique suitable for performing regression on high-dimensional data. Provenance identification for the obsidian samples was evaluated for three separate labeling frameworks. The first framework consisted of a binary classification problem to distinguish CVF samples from non-CVF samples. The second approach focused on the CVF samples with labels that corresponded to the eight separate Coso sites encompassed by the 27 samples. In the third analysis, non-CVF samples were excluded, and the remaining 27 CVF samples were labeled based on groupings defined from previous major and trace element chemical studies, which reduces the number of possible classes from eight to four. Different aspects of the classifier setup considered in this study include the training/testing routine (a 27-fold leave-one-sample-out setup versus a simple split of the data into separate sets for training and evaluation), the number of latent variables used in the regression model, and whether PLSDA operating on the entire broadband LIBS spectrum is superior to that using only a selected subset of LIBS emission lines. The results point to the robustness of the PLSDA technique and suggest that LIBS analysis combined with the appropriate statistical signal processing has the potential to be a useful tool for chemical analysis of archaeological artifacts and geological specimens.

74 ATOMIC AND MOLECULAR PHYSICS↗

Architecture independent environment for developing engineering software on MIMD computers

Engineers are constantly faced with solving problems of increasing complexity and detail. Multiple Instruction stream Multiple Data stream (MIMD) computers have been developed to overcome the performance limitations of serial computers. The hardware architectures of MIMD computers vary considerably and are much more sophisticated than serial computers. Developing large scale software for a variety of MIMD computers is difficult and expensive. There is a need to provide tools that facilitate programming these machines. First, the issues that must be considered to develop those tools are examined. The two main areas of concern were architecture independence and data management. Architecture independent software facilitates software portability and improves the longevity and utility of the software product. It provides some form of insurance for the investment of time and effort that goes into developing the software. The management of data is a crucial aspect of solving large engineering problems. It must be considered in light of the new hardware organizations that are available. Second, the functional design and implementation of a software environment that facilitates developing architecture independent software for large engineering applications are described. The topics of discussion include: a description of the model that supports the development of architecture independent software; identifying and exploiting concurrency within the application program; data coherence; engineering data base and memory management.

Valimohamed, Karim A.↗

The mass storage testing laboratory at GSFC

Industry-wide benchmarks exist for measuring the performance of processors (SPECmarks), and of database systems (Transaction Processing Council). Despite storage having become the dominant item in computing and IT (Information Technology) budgets, no such common benchmark is available in the mass storage field. Vendors and consultants provide services and tools for capacity planning and sizing, but these do not account for the complete set of metrics needed in today's archives. The availability of automated tape libraries, high-capacity RAID systems, and high- bandwidth interconnectivity between processor and peripherals has led to demands for services which traditional file systems cannot provide. File Storage and Management Systems (FSMS), which began to be marketed in the late 80's, have helped to some extent with large tape libraries, but their use has introduced additional parameters affecting performance. The aim of the Mass Storage Test Laboratory (MSTL) at Goddard Space Flight Center is to develop a test suite that includes not only a comprehensive check list to document a mass storage environment but also benchmark code. Benchmark code is being tested which will provide measurements for both baseline systems, i.e. applications interacting with peripherals through the operating system services, and for combinations involving an FSMS. The benchmarks are written in C, and are easily portable. They are initially being aimed at the UNIX Open Systems world. Measurements are being made using a Sun Ultra 170 Sparc with 256MB memory running Solaris 2.5.1 with the following configuration: 4mm tape stacker on SCSI 2 Fast/Wide; 4GB disk device on SCSI 2 Fast/Wide; and Sony Petaserve on Fast/Wide differential SCSI 2.

Venkataraman, Ravi↗

Cumulative Interference to Aircraft Radios from Multiple Portable Electronic Devices

Cumulative interference effects from portable electronic devices (PEDs) located inside a passenger cabin are conservatively estimated for aircraft radio receivers. PEDs' emission powers in an aircraft radio frequency band are first scaled according to their locations' interference path loss (IPL) values, and the results are summed to determine the total interference power. The multiple-equipment-factor (MEF) is determined by normalizing the result against the worst case contribution from a single device. Conservative assumptions were made and MEF calculations were performed for Boeing 737's Localizer, Glide-slope, Traffic Collision Avoidance System, and Very High Frequency Communication radio systems where full-aircraft IPL data were available. The results show MEF for the systems to vary between 10 and 14 dB. The same process was also used on the more popular window/door IPL data, and the comparison show the multiple-equipment-factor results came within one decibel (dB) of each other.

Nguyen, Truong X.↗

A portable parton-level event generator for the high-luminosity LHC

The rapid deployment of computing hardware different from the traditional CPU+RAM model in data centers around the world mandates a change in the design of event generators for the Large Hadron Collider, in order to provide economically and ecologically sustainable simulations for the high-luminosity era of the LHC. Parton-level event generation is one of the most computationally demanding parts of the simulation and is therefore a prime target for improvements. We present a production-ready leading-order parton-level event generation framework capable of utilizing most modern hardware and discuss its performance in the standard candle processes of vector boson and top-quark pair production with up to five additional jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radioembolization for Neuroendocrine Liver Metastases: Safety, Imaging, and Long-Term Outcomes

Purpose: To present long-term outcomes on the safety and efficacy of Yttrium-90 radioembolization in the treatment of unresectable hepatic neuroendocrine metastases refractory to standard-of-care therapy. Methods and Materials: This study was approved by our institutional review board and was compliant with the Health Insurance Portability and Accountability Act. Forty patients with hepatic neuroendocrine metastases were treated with {sup 90}Y radioembolization at a single center. Toxicity was assessed using National Cancer Institute Common Terminology Criteria v3.0. Response to therapy was assessed by World Health Organization (WHO) guidelines for size and European Association for the Study of the Liver disease (EASL) guidelines for necrosis. Time to response and overall survival were calculated using the Kaplan-Meier method. Univariate and multivariate analyses were performed. Results: The median dose was 113 Gy (29-299 Gy). Clinical toxicities included fatigue (63%), nausea/vomiting (40%), abdominal pain (18%), fever (8%), diarrhea and weight loss (5%); Grade 3 and 4 bilirubin toxicities were experienced by 2 patients and 1 patient, respectively. Different responses were noted by WHO (complete response, 1.2%; partial response, 62.7%) and EASL (complete response, 20.5%; partial response, 43.4%). Median time to response was 4 and 4.9 months by lesion and patient, respectively. The 1-, 2-, and 3-year overall survival rates were 72.5%, 62.5%, and 45%, respectively. Eastern Cooperative Oncology Group (ECOG) performance score 0 (p < 0.0001), tumor burden {<=}25% (p = 0.0019), albumin {>=}3.5 g/dL (p = 0.017), and bilirubin {<=}1.2 mg/dL (p = 0.002) prognosticated survival on univariate analysis; only ECOG performance score 0 and bilirubin {<=}1.2 mg/dL prognosticated better survival outcome on multivariate analysis (p = 0.0001 and p = 0.02). Conclusion: Yttrium-90 therapy for hepatic neuroendocrine metastases leads to satisfactory tumor response and patient survival with low toxicity, in line with published national guidelines recommending radioembolization as a potential option for unresectable hepatic neuroendocrine metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Slouching towards exascale.

One question before the high-performance computing community is 'How will application developers write code for exascale machines?' At this point it looks like they might be riding a rough beast indeed. This paper is a brief assessment of where we stand now with respect to writing programs for our largest supercomputers and what we should do next. MPI is likely to remain a critical part of the programming infrastructure as we move towards exascale, but more is needed, in particular a robust, portable, and effective standard for parallel programming within a single address space, perhaps for heterogeneous processors. Formal methods provide the only truly scalable approach to developing correct code in this complex programming environment.

99 GENERAL AND MISCELLANEOUS↗

Concurrent Probabilistic Simulation of High Temperature Composite Structural Response

A computational structural/material analysis and design tool which would meet industry's future demand for expedience and reduced cost is presented. This unique software 'GENOA' is dedicated to parallel and high speed analysis to perform probabilistic evaluation of high temperature composite response of aerospace systems. The development is based on detailed integration and modification of diverse fields of specialized analysis techniques and mathematical models to combine their latest innovative capabilities into a commercially viable software package. The technique is specifically designed to exploit the availability of processors to perform computationally intense probabilistic analysis assessing uncertainties in structural reliability analysis and composite micromechanics. The primary objectives which were achieved in performing the development were: (1) Utilization of the power of parallel processing and static/dynamic load balancing optimization to make the complex simulation of structure, material and processing of high temperature composite affordable; (2) Computational integration and synchronization of probabilistic mathematics, structural/material mechanics and parallel computing; (3) Implementation of an innovative multi-level domain decomposition technique to identify the inherent parallelism, and increasing convergence rates through high- and low-level processor assignment; (4) Creating the framework for Portable Paralleled architecture for the machine independent Multi Instruction Multi Data, (MIMD), Single Instruction Multi Data (SIMD), hybrid and distributed workstation type of computers; and (5) Market evaluation. The results of Phase-2 effort provides a good basis for continuation and warrants Phase-3 government, and industry partnership.

Abdi, Frank↗

Refine your search to explore more results.