Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Effect of Polymer Electrode Morphology on Performance of a Lithium/Polypyrrole Battery

A variety of conducting polymer batteries were described in the recent literature. In this work, a Li/Polypyrrole secondary battery is described. The effect of controlling the morphology of the polymer on enhancement of counterion diffusion in the polymer phase is explored. A method of preparing conducting polymers was developed which yields high surface area per unit volume of electrode material. A porous membrane is used as a template in which to electrochemically polymerize pyrrole, then the membrane is dissolved, leaving the polymer in a fibrillar form. Conventionally, the polymer is electrochemically polymerized as a dense polymer film on a smooth Pt disk electrode. Previous work has shown that when the polymer is electrochemically polymerized in fribrillar form, charge transport rates are faster and charge capacities are greater than for dense, conventionally grown films containing the same amount of polymer. The purpose is to expand previous work by further investigating the possibilities of the optimization of transport rates in polypyrrole films by controlling the morphology of the films. The utility of fibrillar polypyrrole as a cathode material in a lithium/polymer secondary battery is then assessed. The performance of the fibrillar battery is compared to the performance of an analogous battery which employed a conventionally grown polypyrrole film. The study includes a comparison of cyclic voltammetry, shape of charge/discharge curves, discharge time and voltage, cycle life, coulombic efficiencies, charge capacities, energy densities, and energy efficiencies.

Nicholson, Marjorie Anne↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extended abdominopelvic MRI versus CT at the time of adnexal mass characterization for assessing radiologic peritoneal cancer index (PCI) prior to cytoreductive surgery

Purpose: To evaluate whether extending the MRI scan to include the abdomen at the time of adnexal mass characterization could replace additional CT for peritoneal cancer index (PCI) assessment. Methods: After institutional review board approval for this prospective study, 36 consecutive females with ovarian and FT malignancies were included. All patients signed an informed consent. Patients underwent preoperative CT (32 patients) and MRI (36 patients). Images were interpreted by 2 independent observers. Surgical data were available in 27 patients. Region-by-region analysis was performed for detection rates of peritoneal carcinomatosis (PC). Inter-observer agreement for each region was evaluated by kappa statistics. Radiologic PCI was calculated by CT and MRI independently and inter-observer agreement for CT and MRI as well as agreement between radiologic and surgical PCI were evaluated by weighted-kappa statistics. Results: On region-by-region analysis, the highest detection rates of PC were noted at the central abdomen and pelvis. Detection rates were higher by MRI than CT, mainly in bowel serosal surface, pelvis, and right upper abdomen regions. Inter-observer agreement of MRI was higher than CT in most regions. The median PCI by CT was 5 and 4 for the first and second observers (range 0–21 for both observers), respectively. The median PCI by MRI was 6 (range 0–23 for both observers). The inter-observer agreement of PCI was excellent by both CT and MRI (k = 0.876 and k = 0.912, respectively). The agreement between CT and surgical PCI was 0.660 and 0.590 for the first and second observers, respectively. The agreement between MRI and surgical PCI was 0.797 and 0.798 for the first and second observers, respectively. Conclusions: Extending MRI scan to include the abdomen at the time of adnexal mass characterization allows accurate estimation of PC, with better results than CT, obviating the need for dedicated CT scan of abdomen and pelvis for imaging of PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrosion Performance of Fe-Based Alloys in Simulated Oxy-Fuel Environment

The long-term corrosion of Fe-based alloys in simulated oxy-fuel environment at 1023 K (750 A degrees C) was studied. Detailed results are presented on weight change, scale thickness, internal penetration, microstructural characteristics of the corrosion products, and the cracking of scales for the alloys after exposure at 1023 K (750 A degrees C) for up to 3600 hours. An incubation period during which the corrosion rate was low was observed for the alloys. After the incubation period, the corrosion accelerated, and the corrosion process followed linear kinetics. Effects of alloy, CaO-containing ash, and gas composition on the corrosion rate were also studied. In addition, synchrotron nanobeam X-ray analysis was employed to determine the phase and chemical composition of the oxide layers on the alloy surface. Results from these studies are being used to address the long-term corrosion performance of Fe-based alloys in various coal-ash combustion environments and to develop methods to mitigate high-temperature ash corrosion.

36 MATERIALS SCIENCE↗

Bayesian calibration of bubble size dynamics applied to CO 2 gas fermenters

To accelerate the scale-up of gaseous CO 2 fermentation reactors, computational models need to predict gas-to-liquid mass transfer which requires capturing the bubble size dynamics, i.e. bubble breakup and coalescence. However, the applicability of existing models beyond air–water mixtures remains to be established. Here, an inverse modeling approach, accelerated with a neural network surrogate, calibrates the breakup and coalescence closure models, that are used in class methods for population balance modeling (PBM). The calibration is performed based on experimental results obtained in a CO 2 -air–water-coflowing bubble column reactor. Bayesian inference is used to account for noise in the experimental dataset and bias in the simulation results. To accurately capture gas holdup and interphase mass transfer, the results show that the breakage rate needs to be increased by one order of magnitude. In conclusion, the inferred model parameters are then used on a separate configuration and shown to also improve bubble size distribution predictions.

09 BIOMASS FUELS↗

Long-Term Outcomes After Proton Beam Therapy for Sinonasal Squamous Cell Carcinoma

Purpose: Squamous cell carcinoma (SCC) is the most common sinonasal cancer and is associated with one of the poor outcomes. Proton therapy allows excellent target coverage with maximal sparing of adjacent normal tissues. We evaluated the long-term outcomes in patients with sinonasal SCC treated with proton therapy. Methods and Materials: Between 1991 and 2008, 54 patients with Stage III and IV SCC of the nasal cavity and paranasal sinus received proton beam therapy at our institution to a median dose of 72.8 Gy(RBE). Sixty-nine percent underwent prior surgical resection, and 74% received elective nodal radiation. Locoregional control and survival probabilities were estimated with the Kaplan-Meier method. Multivariate analyses were performed using the Cox proportional-hazards model. Treatment toxicity was scored using the Common Terminology Criteria for Adverse Events version 4.0. Results: With a median follow-up time of 82 months in surviving patients, there were 10 local, 7 regional, and 11 distant failures. The 2-year and 5-year actuarial local control rate was 80%. The 2-year and 5-year rates of overall survival were 67% and 47%, respectively. Only smoking status was predictive for worse locoregional control, with current smokers having a 5-year rate of 23% compared with 83% for noncurrent smokers (P=.004). Karnofsky performance status ≤80 was the most significant factor predictive for worse overall survival in multivariate analysis (adjusted hazard ratio 4.5, 95% confidence interval 1.6-12.5, P=.004). There were nine grade 3 and six grade 4 toxicities, and no grade 5 toxicity. Wound adverse events constituted the most common grade 3-4 toxicity. Conclusions: Our long-term results show that proton radiation therapy is well tolerated and yields good locoregional control for SCC of the nasal cavity and paranasal sinus. Current smokers and patients with poor performance status had inferior outcomes. Prospective study is necessary to compare IMRT with proton therapy in the treatment of sinonasal malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid numerical and machine learning framework for evaluating the performance of a 780 cm 2 aqueous organic redox flow battery

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low capacity degradation in 10 cm2 cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier for commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm 2 DHP-based AORFB by combining physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical quantities and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. These combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks the first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Novel textured surfaces for superior corrosion mitigation in molten carbonate salts for concentrating solar power

Corrosion of metals in contact with molten salts used for thermal energy storage and heat transport at high temperatures is a serious impediment to the development of next-generation concentrating solar thermal systems. Toward addressing this limitation, novel multiscale fractal-textured Ni coatings on a variety of substrate alloys are presented in this study for exceptional corrosion mitigation in molten carbonate salts at a high temperature. Strongly adherent, durable, single-layer, and double-layer multiscale fractal coatings were fabricated using the electrodeposition method. Corrosion performance of the coatings on SS310, SS316, SS347, and In800H was studied in molten carbonate salt (32% Li 2 CO 3 +33% Na 2 CO 3 +35% K 2 CO 3 ) at 750 °C. Single-layer coatings are stable up to 300 h immersion, whereas double-layer coatings are stable beyond 750 h. The corrosion rate of double-layer Ni coatings on ferrous alloys was reduced by as much as 60% from that of uncoated surfaces and was about 18% below that of higher cost, high Ni content Ha230. The study represents the first-ever report of corrosion characteristics of alloys in carbonate salts at 750 °C and the first demonstration of a means of dramatically reducing corrosion in carbonate salts at a high temperature. The article is significant in that it provides a viable approach for low-cost structural alloys to be corrosion-resistant to molten carbonate heat transfer fluids and storage media in high-temperature concentrating solar thermal applications. Furthermore, the corrosion-resistant coatings provide opportunities for the use of low-cost, ferritic alloys instead of the expensive nickel-based alloys in practice.

14 SOLAR ENERGY↗

Revealing the dynamics of ultrarelativistic non-equilibrium many-electron systems with phase space tomography

The description of physical processes with many-particle systems is a key approach to the modeling of numerous physical systems. For example in storage rings, where ultrarelativistic particles are agglomerated in dense bunches, the modeling and measurement of their phase-space distribution is of paramount importance: at any time the phase-space distribution not only determines the complete space-time evolution but also provides fundamental performance characteristics for storage ring operation. Here, we demonstrate a non-destructive tomographic imaging technique for the 2D longitudinal phase-space distribution of ultrarelativistic electron bunches. For this purpose, we utilize a unique setup, which streams turn-by-turn near-field measurements of bunch profiles at MHz repetition rates. To demonstrate the feasibility of our method, we induce a non-equilibrium state and show that the phase-space distribution microstructuring as well as the phase-space distribution dynamics can be observed in great detail. Our approach offers a pathway to control ultrashort bunches and supports, as one example, the development of compact accelerators with low energy footprints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical evaluation of a medical high dynamic range display

Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.09% of difference. For the difficult nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 1.38% of difference. The averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in function of the local average luminance around the nodules. For the lowest luminance range, there is more than 30% in favor of the HDR display. For the highest luminance range, there is less than 6% in favor of the LDR display. Conclusions: This study shows the potential benefit of using a HDR display in radiology.

60 APPLIED LIFE SCIENCES↗

Evaluating large scale aqueous organic redox flow battery performance with a hybrid numerical and machine learning framework

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low-capacity degradation in 10 cm$^2$ cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier to commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm$^2$ DHP-based AORFB by combining a physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. Such combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Fluid-Dynamic Mechanisms Underlying Wind Turbine Wake Control with Strouhal-Timed Actuation

A reduction in wake effects in large wind farms through wake-aware control has considerable potential to improve farm efficiency. This work examines the success of several emerging, empirically derived control methods that modify wind turbine wakes (i.e., the pulse method, helix method, and related methods) based on Strouhal numbers on the O(0.3). Drawing on previous work in the literature for jet and bluff-body flows, the analyses leverage the normal-mode representation of wake instabilities to characterize the large-scale wake meandering observed in actuated wakes. Idealized large-eddy simulations (LES) using an actuator-line representation of the turbine blades indicate that the n=0 and ±1 modes, which correspond to the pulse and helix forcing strategies, respectively, have faster initial growth rates than higher-order modes, suggesting these lower-order modes are more appropriate for wake control. Exciting these lower-order modes with periodic pitching of the blades produces increased modal growth, higher entrainment into the wake, and faster wake recovery. Modal energy gain and the entrainment rate both increase with streamwise distance from the rotor until the intermediate wake. This suggests that the wake meandering dynamics, which share close ties with the relatively well-characterized meandering dynamics in jet and bluff-body flows, are an essential component of the success of wind turbine wake control methods. A spatial linear stability analysis is also performed on the wake flows and yields insights on the modal evolution. In the context of the normal-mode representation of wake instabilities, these findings represent the first literature examining the characteristics of the wake meandering stemming from intentional Strouhal-timed wake actuation, and they help guide the ongoing work to understand the fluid-dynamic origins of the success of the pulse, helix, and related methods.

17 WIND ENERGY↗

End-User Perspectives on Using Quantitative Real-Time PCR and Genomic Sequencing in the Field

Quantitative real-time PCR and genomic sequencing have become mainstays for performing molecular detection of biological threat agents in the field. There are notional assessments of the benefits, disadvantages, and challenges that each of these technologies offers according to findings in the literature. However, direct comparison between these two technologies in the context of field-forward operations is lacking. Most market surveys, whether published in print form or provided online, are directed to product manufacturers who can address their respective specifications and operations. One method for comparing these technologies is surveying end-users who are best suited for discussing operational capabilities, as they have hands-on experience with state-of-the-art molecular detection platforms and protocols. These end-users include operators in military defense and first response, as well as various research scientists in the public sector such as government and service laboratories, private sector, and civil society such as academia and nonprofit organizations performing method development and executing these protocols in the field. Our objective was to initiate a survey specific to end-users and their feedback. We developed a questionnaire that asked respondents to (1) determine what technologies they currently use, (2) identify the settings where the technologies are used, whether lab-based or field-forward, and (3) rate the technologies according to a set list of criteria. Of particular interest are assessments of sensitivity, specificity, reproducibility, scalability, portability, and discovery power. This article summarizes the findings from the end-user perspective, highlighting technical and operational challenges.

59 BASIC BIOLOGICAL SCIENCES↗

An Approach to Dependence Assessment in Human Reliability Analysis: Application of Lag and Linger Effects

Dependence assessment refers to an approach used in human reliability analysis (HRA) to adjust a human error probability (HEP) for the following action by considering the impact of the preceding action. It has been known to significantly affect the overall results of probabilistic safety assessment (PSA). If the dependence assessment is not adequate, the result could be unconvincing for explaining the operator failures in the context of PSA. To date, several methods and some recent research have identified suggestions for treating dependence issues in HRA; however, these are still exclusively based on the intrinsic approach of the Technique for Human Error Rate Prediction (THERP), an HRA method. THERP inevitably has a challenge with the subjectivity of expert evaluation as well as the requirement for PSA and HRA expertise with resource-intensive and time-consuming processes. This paper suggests an approach to dependence assessment that could not only minimize the influence of expert judgment, but also saves time to perform the analysis with reasonable manpower. It modifies existing HRA methods with considering lag and linger effects to apply dependence effects for them. Based on a representative HRA method, i.e., Standardized Plant Analysis Risk - HRA (SPAR-H), guidance for how to apply lag and linger effects for the HRA method is suggested. Then, an investigation is carried out to compare quantification results of the revised HRA method with that of the original approach based on experimental data.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of an electrochemical N2/H2 gas separator

A program was successfully completed to evaluate an electrochemical nitrogen/hydrogen (N2/H2) separator for use in a spacecraft nitrogen (N2) generator. Based on the technical data obtained a N2/H2 separator subsystem consisting of an organic polymer gas permeator first stage and an electrochemical second and third stage was estimated to have the lowest total spared equivalent weight, 257 kg (566 lb), for a 15 lb/day N2 generation rate. A pre-design analysis of the electrochemical N2/H2 separator revealed that its use as a first stage resulted in too high a power requirement to be competitive with the organic polymer membrane and the palladium-silver membrane separation methods. As a result, program emphasis was placed on evaluating the electrochemical. A parametric test program characterized cell performance and established second- and third-stage electrochemical N2/H2 separator operating conditions. A design verification test was completed on the second and third stages. The second stage was then successfully endurance tested for 200 hours.

Marshall, R. D.↗

Free-flying teleoperator for space missions

The design of a free-flying teleoperator (FFTO) intended to assist the Space Shuttle in performing its various missions is discussed, where FFTO is to be carried into earth orbit and returned to earth by the Shuttle. The FFTO system is described as to configuration, major subsystems, and mechanization concept. The kinematics of the manipulator and methods of sedating a satellite are discussed. Satellite equations of motion are provided, and cases of zero tumbling rate and non-zero tumbling rate are examined. Cases for which use of FFTO is compulsory are indicated, and the FFTO contributions to the Shuttle missions are analyzed.

Hung, J. C.↗

Silicon film solar cell process

The most promising way to reduce the cost of silicon in solar cells while still maintaining performance is to utilize thin films (10 to 20 microns thick) of crystalline silicon. The method of solution growth is being employed to grow thin polycrystalline films of silicon on dissimilar substrates. The initial results indicate that, using tin as the solvent, this growth process only requires operating temperatures in the range of 800 C to 1000 C. Growth rates in the range of 0.4 to 2.0 microns per minute and grain sizes in the range of 20 to 100 microns were achieved on both quartz and coated steel substrates. Typically, an aspect ratio of two to three between the width and the Si grain thickness is seen. Uniform coverage of Si growth on quartz over a 2.5 x 2.5 cm area was observed.

Hall, R. B.↗

Loitering and range performance of turbojet-powered aircraft determined by off-design engine cycle analysis

The loitering and range performance of airplanes equipped with several different turbojet engines was analytically investigated by applying the results of off-design cycle analyses to specific airplane characteristics. The method of off-design cycle analysis is presented herein and is verified by a check with experimental data. For all engines considered, the loitering and the range fuel flows obtained with rated tail-pipe nozzle area, variable engine speed operations were within 2 or 3 percent of the optimum fuel flow obtainable with any method of engines operation. The optimum loitering altitude generally occurred between approximately 25,000 and 35,000 feet with corresponding optimum flight Mach numbers of 0.4 to 0.65. In general, the optimum range fuel flows occurred at 3000 to 5000 feet higher altitude and at approximately 0.15 higher flight Mach numbers than the optimum loitering fuel flow.

Koutz, Stanley L↗

Refine your search to explore more results.