Quantitative Advanced Data Analysis for Neutron Scatter Cameras.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
We present quantitative fluid inclusion gas analysis on a suite of violently-formed glasses. We used the incremental crush mass spectrometry method (Norman & Blamey, 2001) to analyze eight pieces of Libyan Desert Glass (LDG). As potential analogues we also analyzed trinitite, three impact crater glasses, and three fulgurites. The 'clear' LDG has the lowest CO{sub 2} content and O{sub 2}/Ar ratios are two orders of magnitude lower than atmospheric. The 'foamy' glass samples have heterogeneous CO{sub 2} contents and O{sub 2}/Ar ratios. N{sub 2}/Ar ratios are similar to atmospheric (83.6). H{sub 2} and He are elevated but it is difficult to confirm whether they are of terrestrial or meteoritic origin. Combustion cannot account for oxygen depletion that matches the amount of CO{sub 2} produced. An alternative mechanism is required that removes oxygen without producing CO{sub 2}. Trinitite has exceedingly high CO{sub 2} which we attribute to carbonate breakdown of the caliche at ground zero. The O{sub 2}/Ar ratio for trinitite is lower than atmospheric but higher than all LDG samples. N{sub 2}/Ar ratios closely match atmospheric. Samples from Lonar, Henbury and Aouelloul impact craters have atmospheric N{sub 2}/Ar ratios. O{sub 2}/Ar ratios at Lonar and Henbury are 9.5 to 9.9 whereas the O{sub 2}/Ar ratio is 0.1 for the Aouelloul sample. In most fulgurites the N{sub 2}/Ar ratio is higher than atmospheric, possibly due to interference from CO. Oxygen ranges from 1.3 to 19.3%. Gas signatures of LDG inclusions neither match those from the craters, trinitite nor fulgurites. It is difficult to explain both the observed depletion of oxygen in the LDG and a CO{sub 2} level that is lower than it would be if the CO{sub 2} were simply a product of hydrocarbon combustion in air. One possible mechanism for oxygen depletion is that as air turbulently mixed with a hot jet of vaporized asteroid from an airburst and expanded, the atmospheric oxygen reacted with the metal vapor to form metal oxides that condensed. This observation is compatible with the model of Boslough & Crawford (2008) who suggest that an airburst incinerates organic materials over a large area, melting surface materials that then quench to form glass. Bubbles would contain a mixture of pre-existing atmosphere with combustion products from organic material and products of the reaction between vaporized cosmic materials (including metals) and terrestrial surface and atmosphere.
Not provided.
In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.
The development of microbial communities depends on a combination of complex deterministic and stochastic factors that can dramatically alter the spatial distribution and activities of community members. In this study, we have developed a microwell array platform that can be used to rapidly assemble and track thousands of bacterial communities in parallel. This protocol highlights the utility of the platform and describes its use for optically monitoring the development of simple, two-member communities within an ensemble of arrays within the platform. This demonstration uses two mutants of Pseudomonas aeruginosa, part of a series of mutants developed to study Type VI secretion pathogenicity. Chromosomal inserts of either mCherry or GFP genes facilitate the constitutive expression of fluorescent proteins with distinct emission wavelengths that can be used to monitor community member abundance and location within each microwell. This protocol describes a detailed method for assembling mixtures of bacteria into the wells of the array and using time-lapse fluorescence imaging and quantitative image analysis to measure the relative growth of each member population over time. Lastly, the seeding and assembly of the microwell platform, the imaging procedures necessary for the quantitative analysis of microbial communities within the array, and the methods that can be used to reveal interactions between microbial species area all discussed.
Laboratory methods to determine quantitative nitrogen, hydrogen, oxygen, and carbon impurities in sodium
To investigate the prognostic utility of quantitative 3-dimensional magnetic resonance imaging radiomic analysis for primary pediatric embryonal brain tumors.
The paper describes the results of the quantitative Uncertainty and Sensitivity (U/S) Analysis of a Rod Ejection Accident (REA) which is simulated by the coupled system code ATHLET-QUABOX/CUBBOX applying the GRS tool for U/S analysis SUSA/XSUSA. For the present study, a UOX/MOX mixed core loading based on a generic PWR is modeled. A control rod ejection is calculated for two reactor states: Hot Zero Power (HZP) and 30% of nominal power. The worst cases for the rod ejection are determined by steady-state neutronic simulations taking into account the maximum reactivity insertion in the system and the power peaking factor. For the U/S analysis 378 uncertain parameters are identified and quantified (thermal-hydraulic initial and boundary conditions, input parameters and variations of the two-group cross sections). Results for uncertainty and sensitivity analysis are presented for safety important global and local parameters. (authors)
Fungi generate a wide range of extracellular hydrolytic and oxidative enzymes and reactive metabolites, collectively known as the secretome, that synergistically drive plant litter decomposition in the environment. While secretome studies of model organisms have greatly expanded our knowledge of these enzymes, few have extended secretome characterization to environmental isolates or directly compared temporal patterns of enzyme utilization among diverse species. Thus, the mechanisms of carbon (C) degradation by many ubiquitous soil fungi remain poorly understood. Here we use a combination of iTRAQ proteomics and custom bioinformatic analyses to compare the protein composition of the secretomes of four manganese(II)-oxidizing Ascomycete fungi over a three-week time course. We demonstrate that although the fungi produce a similar suite of extracellular enzymes, they exhibit striking differences in the regulation of these enzymes among species and over time, revealing species-specific and temporal shifts in C utilization strategies as they degrade the same substrate. Specifically, our findings suggest that Paraconiothyrium sporulosum AP3s5-JAC2a and Alternaria alternata SRC1lrK2f employ sequential enzyme secretion patterns concomitant with decreasing resource availability, Stagonospora sp. SRC1lsM3a preferentially degrades proteinaceous substrate before switching to carbohydrates, and Pyrenochaeta sp. DS3sAY3a utilizes primarily peptidases to aggressively attack carbon sources in a concentrated burst. This work highlights the diversity of operative metabolic strategies among cellulose-degrading Ascomycetes and enhances our understanding of their role in C turnover in the environment.
Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.
Quantitative multivariate statistical analysis of average evoked potentials and application to visual stimulus intensity and duration
An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstrated good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL{sup -1}. At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 {mu} L of 200 ng mL{sup -1} mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.
We have proposed the novel isotope analysis technique with Resonance Ionization Mass Spectrometry using Inductively Coupled Plasma as an atomic source (ICP-RIMS). Each component of ICP-RIMS is conceptually designed. We conclude that the orthogonal acceleration time-of-flight mass spectrometer (oa-TOF-MS) driven by a high-repetition-rate pulsed laser would be suitable system for ICP-RIMS. We, additionally, suggest that the first vacuum stage of the vacuum interface, which is between the sampling and skimmer cones, is desired to maintain as low pressure as possible in order to suppress the Doppler broadening and to skim the supersonic jet effectively.
We are investigating the possibility to use laser photodetachment of negative ions as an isobaric selective filter in accelerator mass spectrometry (AMS). If successful, this method can be used to obtain higher sensitivity realized through better selectivity by suppression of molecular and/or elemental isobaric interference in different investigations using ultra rare isotopes in the 10{sup -13} range and below.
HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.
A regional Proton induced X-ray Emission (PIXE) facility is newly developed using 3 Mev Proton beam from Variable Energy Cyclotron, Panjab University, Chandigarh (India). A new target chamber has been designed to cater for Proton Induced Gamma Emission (PIGE) and Rutherford Back Scattering (RBS) along with PIXE measurements. The HPGe x-ray detector, the Ge (Li) gamma-ray detector and a silicon surface barrier (SSB) detector can be mounted simultaneously in the chamber for this purpose. A remotely controlled stepper motor is provided to move the target wheel holding 12/24 samples at a time. This facility is now routinely used for the detection of trace elements in the aerosol, medical and forensic science samples. The paper presents the analysis of Aerosol samples collected from highly polluted steel city of Mandi Govindgarh in Punjab state and relatively clean city of Jammu in Jammu and Kashmir region. The results from the analysis of these samples show some basic differences in the trace element profile of the two cities. The paper also describes the trace element analysis of fly ash in the vicinity of Ropar Thermal Power plant in Punjab. The scope of this study was to determine the concentration and composition of atmospheric particulate matter (PM) in the vicinity of coal-fired thermal power plants in India. The data taken for the Bio-medical samples are also discussed.
Hydrogen is a ubiquitous contaminant that is known to have dramatic effects on the electrical, chemical, and mechanical properties of many types of materials in even minute quantities. Thus, the detection of hydrogen in materials is of major importance. Nuclear Reaction Analysis (NRA) is a powerful technique for nondestructive profiling hydrogen in materials. However, NRA has found only limited use in many applications because of poor sensitivity due to cosmic ray background (CSRB). Most attempts to eliminate CSRB to achieve ppm detection levels using higher energy nuclear reactions or tons of passive shielding are not compatible with commercial ion beam analysis space and equipment requirements Zimmerman, et al. have previously reported upon a coincidence detector that meets IBA space requirements and reduces the cosmic ray background, but the detector suffers from lower detection efficiency and small sample size. We have replaced the BGO well detector in the Zimmerman coincidence detection scheme with a larger Nal well detector and used faster timing electronics to produce a detector that can handle larger samples with higher detection efficiency, and still eliminate cosmic ray background.
This work presents the possibilities offered by a blind source separation method such Multivariate Curve Resolution- Alternating Least Squares (MCR-ALS) in the analysis of Ion Mobility Spectra (IMS). Two security applications are analyzed in this context: the detection of TNT both in synthetic and real samples. Results obtained show the possibilities offered by the direct analysis of the drift time spectra when an appropriate resolution method is used.
Refine your search to explore more results.