Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

A TiO2 abundance map for the northern maria

A map of TiO2 abundance for most of the northern maria is presented. The telescopic data base used is the 0.38/0.56-micron ratio mosaic from Johnson et at. (1977). The titanium content has been estimated using the correlation established by Charette et al. (1974). The combination of observational, processing, and calibration errors indicates that the TiO2 map is accurate to + or - 2% (wt% TiO2) for high TiO2 content (more than 5%) and + or - 1% for low values of TiO2. Analysis of the lunar sample and telescopic data suggests strongly that the spectral parameter mapped is sensitive primarily to TiO2 abundance in the range 3-9% and does not correlate directly with iron content. It is suggested, however, that for the low TiO2 mare regions (less than 2-3% TiO2) there may be a relation between the spectral ratio and iron content and that some of the reddest mare areas in the Imbrium region may have low iron contents as well as low titanium abundances.

Johnson, T. V.↗

Measurement of Aircraft Speed and Altitude

Problems involved in measuring speed and altitude with pressure-actuated instruments (altimeter, airspeed indicator, true-airspeed indicator, Machmeter, and vertical-speed indicator) are examined. Equations relating total pressure and static pressure to the five flight quantities are presented, and criteria for the design of total and static pressure tubes are given. Calibrations of typical static pressure installations (fuselage nose, wing tip, vertical fin, and fuselage vent) are presented, various methods for flight calibration of these installations are described, and the calibration of a particular installation by two of the methods is described in detail. Equations are given for estimating the effects of pressure lag and leaks. Test procedures for the laboratory calibration of the five instruments are described, and accuracies of mechanical and electrical instruments are presented. Operational use of the altimeter for terrain clearance and vertical separation of aircraft is discussed, along with flight technical errors and overall altitude errors of aircraft in cruise operations. Altitude-measuring techniques based on a variety of properties of the Earth and the atmosphere are included. Two appendixes present airspeed and altitude tables and sample calculations for determining the various flight parameters from measured total and static pressures.

Gracey, W.↗

Large, solid particles in the clouds of Venus - Do they exist?

The evidence for solid mode 3 particles in the clouds of Venus is reexamined. The sampling characteristics of the cloud particle size spectrometer (LCPS) are reviewed, and reasons are pointed out for believing that relatively small differences in interpreting the measurements of this instrument could produce systematic errors. It is shown that all of the Pioneer Venus and Venera measurements can be understood if it is assumed that the large particles observed by the LCPS form the tail of the mode 2, H2SO4 size distribution.

Toon, O. B.↗

Combined optimization of image-gathering optics and image-processing algorithm for edge detection

This paper investigates the relationships between the image-gathering and image-processing systems for minimum mean-squared error estimation of scene characteristics. A stochastic optimization problem is formulated in which the objective is to determine a spatial characteristic of the scene rather than a feature of the already blurred, sampled, and noisy image data. The Wiener filter for the sampled image case is obtained as a special case, where the desired characteristics is scene restoration. Optimal edge detection is investigated. It is shown that the optimal edge detector compensates for the blurring introduced by the image-gathering optics, and, notably, that it is not circularly symmetric. The lack of circular symmetry is largely due to the geometric effects of the sampling lattice used in image acquisition.

Halyo, N.↗

The effects of undersampling on multipolarization SAR images

The scattering matrix and Stokes matrix formats for multipolarization synthetic aperture radar (SAR) images are introduced. The effects of converting to the Stokes matrix format, without first doubling the sampling rate to allow for the conversion from a complex to an intensity format is quantified and discussed. It is shown that for most applications the Stokes matrix format is acceptable, since errors introduced by undersampling tend to average out when large numbers of pixels are averaged. For those applications requiring analysis of single image pixels, the scattering matrix format is recommended.

Freeman, A.↗

Digitized synchronous demodulator

A digitized synchronous demodulator is constructed entirely of digital components including timing logic, an accumulator, and means to digitally filter the digital output signal. Indirectly, it accepts, at its input, periodic analog signals which are converted to digital signals by traditional analog-to-digital conversion techniques. Broadly, the input digital signals are summed to one of two registers within an accumulator, based on the phase of the input signal and medicated by timing logic. At the end of a predetermined number of cycles of the inputted periodic signals, the contents of the register that accumulated samples from the negative half cycle is subtracted from the accumulated samples from the positive half cycle. The resulting difference is an accurate measurement of the narrow band amplitude of the periodic input signal during the measurement period. This measurement will not include error sources encountered in prior art synchronous demodulators using analog techniques such as offsets, charge injection errors, temperature drift, switching transients, settling time, analog to digital converter missing code, and linearity errors.

Woodhouse, Christopher E.↗

Portable Microleak-Detection System

The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

Rivers, H. Kevin↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Consistent Evaluation of ACOS-GOSAT, BESD-SCIAMACHY, CarbonTracker, and MACC Through Comparisons to TCCON

Consistent validation of satellite CO2 estimates is a prerequisite for using multiple satellite CO2 measurements for joint flux inversion, and for establishing an accurate long-term atmospheric CO2 data record. Harmonizing satellite CO2 measurements is particularly important since the differences in instruments, observing geometries, sampling strategies, etc. imbue different measurement characteristics in the various satellite CO2 data products. We focus on validating model and satellite observation attributes that impact flux estimates and CO2 assimilation, including accurate error estimates, correlated and random errors, overall biases, biases by season and latitude, the impact of coincidence criteria, validation of seasonal cycle phase and amplitude, yearly growth, and daily variability. We evaluate dry-air mole fraction (X(sub CO2)) for Greenhouse gases Observing SATellite (GOSAT) (Atmospheric CO2 Observations from Space, ACOS b3.5) and SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) (Bremen Optimal Estimation DOAS, BESD v2.00.08) as well as the CarbonTracker (CT2013b) simulated CO2 mole fraction fields and the Monitoring Atmospheric Composition and Climate (MACC) CO2 inversion system (v13.1) and compare these to Total Carbon Column Observing Network (TCCON) observations (GGG2012/2014). We find standard deviations of 0.9, 0.9, 1.7, and 2.1 parts per million vs. TCCON for CT2013b, MACC, GOSAT, and SCIAMACHY, respectively, with the single observation errors 1.9 and 0.9 times the predicted errors for GOSAT and SCIAMACHY, respectively. We quantify how satellite error drops with data averaging by interpreting according to (error(sup 2) equals a(sup 2) plus b(sup 2) divided by n (with n being the number of observations averaged, a the systematic (correlated) errors, and b the random (uncorrelated) errors). a and b are estimated by satellites, coincidence criteria, and hemisphere. Biases at individual stations have year-to-year variability of 0.3 parts per million, with biases larger than the TCCON predicted bias uncertainty of 0.4 parts per million at many stations. We find that GOSAT and CT2013b under-predict the seasonal cycle amplitude in the Northern Hemisphere (NH) between 46 and 53 degrees North latitude, MACC over-predicts between 26 and 37 degrees North latitude, and CT2013b under-predicts the seasonal cycle amplitude in the Southern Hemisphere (SH). The seasonal cycle phase indicates whether a data set or model lags another data set in time. We find that the GOSAT measurements improve the seasonal cycle phase substantially over the prior while SCIAMACHY measurements improve the phase significantly for just two of seven sites. The models reproduce the measured seasonal cycle phase well except for at Lauder_125HR (CT2013b) and Darwin (MACC). We compare the variability within 1 day between TCCON and models in June-July-August; there is correlation between 0.2 and 0.8 in the NH, with models showing 10-50 percent the variability of TCCON at different stations and CT2013b showing more variability than MACC. This paper highlights findings that provide inputs to estimate flux errors in model assimilations, and places where models and satellites need further investigation, e.g., the SH for models and 45-67 degrees North latitude for GOSAT and CT2013b.

ACOS-GOSAT↗

A histogram-free multicanonical Monte Carlo algorithm for the construction of analytical density of states

We report a new multicanonical Monte Carlo (MC) algorithm to obtain the density of states (DOS) for physical systems with continuous state variables in statistical mechanics. Our algorithm is able to obtain an analytical form for the DOS expressed in a chosen basis set, instead of a numerical array of finite resolution as in previous variants of this class of MC methods such as the multicanonical (MUCA) sampling and Wang-Landau (WL) sampling. This is enabled by storing the visited states directly in a data set and avoiding the explicit collection of a histogram. This practice also has the advantage of avoiding undesirable artificial errors caused by the discretization and binning of continuous state variables. Our results show that this scheme is capable of obtaining converged results with a much reduced number of Monte Carlo steps, leading to a significant speedup over existing algorithms.

Li, Ying Wai↗

Human Performance Analysis Depending on Operator Expertise (Student vs. Operator) and Simulator Complexity (Rancor Microworld vs. Compact Nuclear Simulator)

Human reliability analysis (HRA) evaluates human errors and provides human error probabilities (HEPs) for application in probabilistic safety assessment (PSA), which is a comprehensive safety assessment method for nuclear power plants (NPPs). Generally, HRA methods estimate HEPs based on human reliability data collected from actual historical measurement, simulator experiments, or expert judgement. Most recent HRA data collection studies focus on collecting data via full-scope main control room (MCR) simulators with actual licensed reactor operators. Contrary to this, Idaho National Laboratory (INL) has adopted a different approach, which attempts to collect HRA data based on experiment using simplified simulators and student participants by following the Simplified Human Error Experimental Program (SHEEP). This approach has a couple of advantages compared to full-scope data collection. Representatively, it has relatively low entry point for collecting HRA data, and secures large sample sizes with reasonable cost and labor. In the previous studies, we developed the SHEEP framework, then verified whether the data collected through the framework could support a representative full-scope data collection study, i.e., the Human Reliability Data Extraction (HuREX) study. Also, we analyzed human performance measurements depending on participant type (i.e., student vs. operator). In this paper, we analyze human performance data collected from an experiment comparing operator expertise and simulator complexity when using the more simplified simulator developed by INL, i.e., Rancor Microworld and the less simplified simulator, i.e., Compact Nuclear Simulator (CNS) developed by Korea Atomic Energy Research Institute (KAERI). Analysis of variance (ANOVA) tests and correlation analysis are used for analyzing the experimental data.

99 GENERAL AND MISCELLANEOUS↗

Regularized Differentiation for Bioburden Density Estimation in Planetary Protection

In this paper, we propose and investigate the performance of two novel shrinkage estimators for bioburden density estimation in planetary protection. The estimators are based on the regularized differentiation of a cumulative count of colony forming units collected throughout the data collecting session or the life cycle of the entire mission. The regularized differentiation recasts the problem of bioburden density estimation as a linear least squares problem. The least squares problem is then solved through regularization techniques, such as truncated singular value decomposition and penalized least squares. The regularization is necessary to avoid noise amplification during the differentiation of noisy data. The two regularization estimators are compared with four other commonly used estimators to simultaneously evaluate the means of multivariable independent Poisson distributions: the maximum likelihood, noninformative Bayes estimator with Jeffreys prior, Empirical Bayes using conjugate gamma-Poisson model with gamma parameters selected by method of moments, and the Clevenson-Zidek estimator. It is shown through computer-simulated data that the regularized differentiation based on ridge regression has the smallest mean-squared error among all estimators. The analysis of shrinkage mechanism implemented by regularized differentiation is performed, and it is shown that the regularized differentiation amounts to performing a weighted averaging of all the samples. The weights are determined by the regularization parameter automatically selected by the L-curve technique. Since the method of least squares makes no distributional assumptions about the data, it presents an attractive technique for bioburden density estimation when there are concerns about the misspecification of the distributional model. The paper concludes with the analysis of the bioburden data collected during InSight mission and directions for future work.

97 - MATHEMATICS AND COMPUTING↗

Photometric and spectroscopic footprint corrections in the SLOAN Digital Sky Survey’s 6th data release

We identify and correct numerous errors within the photometric and spectroscopic footprints (SFs) of the Sloan Digital Sky Survey’s (SDSS) 6th data release (DR6). Within the SDSS’s boundaries hundreds of millions of objects have been detected. Yet we present evidence that the boundaries themselves contain a significant number of mistakes that are being revealed for the first time within this paper. Left unaddressed, these can introduce systematic biases into galaxy clustering statistics. Using the DR6 Main Galaxy Sample (MGS) targets as tracers, we reveal inconsistencies between the photometric and SF definitions provided in the Catalog Archive Server (CAS), and the measurements of targets therein. First, we find that 19.7 deg{sup 2} of the DR6 photometric footprint are devoid of MGS targets. In volumes of radii 7 h{sup −1} Mpc, this can cause errors in the expected number of galaxies to exceed 60%. Second, we identify seven areas that were erroneously included or excluded from the SF. Moreover, the tiling algorithm that positioned spectroscopic fibers during and between DRs caused many areas along the edge of the SF to be significantly undersampled relative to the footprint’s interior. Through our corrections, we increase the completeness 2.2% by trimming 3.6% of the area from the existing SF. The sum total of these efforts has generated the most accurate description of the SDSS DR6 footprints ever created.

79 ASTRONOMY AND ASTROPHYSICS↗

Lu-Hf and Sm-Nd geochronological constraints on the influence of subduction metamorphism in controlling the Hf-Nd terrestrial array: Evidence from the world’s orogenic belts

To create a better understanding of the influence of subduction metamorphism on the Hf-Nd terrestrial array, this study examines all of the available Lu-Hf and Sm-Nd garnet isochron ages from the world’s orogenic eclogites and amphi bolites. The garnet isochron y-intercept values provide a record of each sample’s epsilon Hf ( ε Hf) and Nd ( ε Nd) at the age recorded by the isochron, which in the case of most orogenic eclogites and amphibolites is the time of prograde metamorphism during subduction. It is further possible to assess the extent to which each sample’s Lu-Hf and Sm-Nd isotope systematics have remained undisturbed since the date recorded by the isochron by comparison of the bulk-rock isotope systematics with the isochron initial value. This approach provides a means of understanding the Lu-Hf and Sm-Nd systematics of post-subduction metamorphic oceanic crust. On a global scale, the coupled Lu-Hf and Sm-Nd isotope systematics of this crust closely align with the Hf-Nd terrestrial array and have average 176 Lu/ 177 Hf and 147 Sm/ 144 Nd ratios within error of the chondritic uniform reservoir values. This is an important finding because it suggests that a reservoir of deeply subducted oceanic crust, possibly residing at the core-mantle boundary, is unlikely to be significantly fractionated from the Hf-Nd terrestrial array. In contrast to the samples of subduction-metamorphosed oceanic crust, metamorphic rocks with a continental crustal protolith demonstrate garnet isochron initial values and bulk-rock Lu-Hf and Sm-Nd isotope systematics indicating significant decoupling from the Hf-Nd terrestrial array. However, because this material is not readily subducted, this strongly decoupled signature is unlikely to be transferred into deep Earth. Mixing calculations aimed at developing a clearer understanding of what factors control decoupling of a sample’s Lu-Hf and Sm-Nd systematics from the Hf-Nd terrestrial array highlight the complexity of mass-transfer regimes operating in the subduction environment.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Experimental Methods for Estimating Matrix Diffusion Coefficients for Contaminant Transport Modeling

Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Visibility of wavelet quantization noise

The discrete wavelet transform (DWT) decomposes an image into bands that vary in spatial frequency and orientation. It is widely used for image compression. Measures of the visibility of DWT quantization errors are required to achieve optimal compression. Uniform quantization of a single band of coefficients results in an artifact that we call DWT uniform quantization noise; it is the sum of a lattice of random amplitude basis functions of the corresponding DWT synthesis filter. We measured visual detection thresholds for samples of DWT uniform quantization noise in Y, Cb, and Cr color channels. The spatial frequency of a wavelet is r 2-lambda, where r is display visual resolution in pixels/degree, and lambda is the wavelet level. Thresholds increase rapidly with wavelet spatial frequency. Thresholds also increase from Y to Cr to Cb, and with orientation from lowpass to horizontal/vertical to diagonal. We construct a mathematical model for DWT noise detection thresholds that is a function of level, orientation, and display visual resolution. This allows calculation of a "perceptually lossless" quantization matrix for which all errors are in theory below the visual threshold. The model may also be used as the basis for adaptive quantization schemes.

NASA Center ARC↗

Determination of elemental composition of shale rocks by laser induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) is used for elemental characterization of outcrop samples from the Marcellus Shale. Powdered samples were pressed to form pellets and used for LIBS analysis. Partial least squares regression (PLS-R) and univariate calibration curves were used for quantification of analytes. The matrix effect is substantially reduced using the partial least squares calibration method. Predicted results with LIBS are compared to ICP-OES results for Si, Al, Ti, Mg, and Ca. As for C, its results are compared to those obtained by a carbon analyzer. Relative errors of the LIBS measurements are in the range of 1.7 to 12.6%. The limits of detection (LODs) obtained for Si, Al, Ti, Mg and Ca are 60.9, 33.0, 15.6, 4.2 and 0.03 ppm, respectively. An LOD of 0.4 wt.% was obtained for carbon. Finally, this study shows that the LIBS method can provide a rapid analysis of shale samples and can potentially benefit depleted gas shale carbon storage research.

58 GEOSCIENCES↗

Improving a Mg/S Battery with YCl 3 Additive and Magnesium Polysulfide

In the originally published version of this article, the SEM image in Figure 4B inadvertently features the wrong sample. The correct Figure 4B is shown below. The authors declare that this correction does not affect the description, interpretation, or the original conclusions of the manuscript. The authors regret the inconvenience this error may have caused.

25 ENERGY STORAGE↗

Refine your search to explore more results.