Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Systematic study of the nuclear potential through high precision back-angle quasi-elastic scattering measurements of {sup 16}O and {sup 32}S on various targets

Elastic and inelastic scattering have proven an excellent method to probe the nuclear potential in the surface region [1]. A surface diffuseness parameter of around 0.63 fm is accepted as describing elastic and inelastic scattering data. A new method to determine the diffuseness was proposed [2] using high precision quasi-elastic excitation functions at sub-barrier energies, and at backward angles. In response to this proposal, we have made measurements for {sup 32}S+{sup 170}Er, {sup 186}W, {sup 197}Au, {sup 208}Pb[3], and more recently for the reactions {sup 16}O+{sup 144,154}Sm, {sup 186}W, {sup 197}Au, {sup 208}Pb[4].Both single channel and coupled-channels calculations have been performed to extract the diffuseness parameter of the nuclear potential, assuming a Woods-Saxon shape. For the reactions involving near-spherical targets, both theoretical analyses give the same diffuseness parameter, as had been hoped, showing that the effect of couplings to intrinsic excited states in the target and projectile is negligible. On the other hand, for deformed systems, coupling effects are surprisingly important even at deep sub-barrier energies, reducing the flux at backward angles.Energy spectra recorded with the back-angle Si detector show a large number of distinct peaks as well as a broad structure at even higher excitation energies. A comparison of the back-scattered energy spectra with coupled-channels calculations demonstrates that including couplings only to low lying collective states in coupled-channels calculations is inadequate in describing the reaction mechanism even at energies close to the barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exact mapping between system-reservoir quantum models and semi-infinite discrete chains using orthogonal polynomials

By using the properties of orthogonal polynomials, we present an exact unitary transformation that maps the Hamiltonian of a quantum system coupled linearly to a continuum of bosonic or fermionic modes to a Hamiltonian that describes a one-dimensional chain with only nearest-neighbor interactions. This analytical transformation predicts a simple set of relations between the parameters of the chain and the recurrence coefficients of the orthogonal polynomials used in the transformation and allows the chain parameters to be computed using numerically stable algorithms that have been developed to compute recurrence coefficients. We then prove some general properties of this chain system for a wide range of spectral functions and give examples drawn from physical systems where exact analytic expressions for the chain properties can be obtained. Crucially, the short-range interactions of the effective chain system permit these open-quantum systems to be efficiently simulated by the density matrix renormalization group methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic field production via the Weibel instability in interpenetrating plasma flows

Here, many astrophysical systems are effectively “collisionless,” that is, the mean free path for collisions between particles is much longer than the size of the system. The absence of particle collisions does not preclude shock formation, however, as shocks can be the result of plasma instabilities that generate and amplify electromagnetic fields. The magnetic fields required for shock formation may either be initially present, for example, in supernova remnants or young galaxies, or they may be self-generated in systems such as gamma-ray bursts (GRBs). In the case of GRB outflows, the Weibel instability is a candidate mechanism for the generation of sufficiently strong magnetic fields to produce shocks. In experiments on the OMEGA Laser, we have demonstrated a quasi-collisionless system that is optimized for the study of the non-linear phase of Weibel instability growth. Using a proton probe to directly image electromagnetic fields, we measure Weibel-generated magnetic fields that grow in opposing, initially unmagnetized plasma flows. The collisionality of the system is determined from coherent Thomson scattering measurements, and the data are compared to similar measurements of a fully collisionless system. The strong, persistent Weibel growth observed here serves as a diagnostic for exploring large-scale magnetic field amplification and the microphysics present in the collisional–collisionless transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of photosynthetic light harvesting systems interacting with N-photon Fock states

Here, we develop a method to simulate the excitonic dynamics of realistic photosynthetic light harvesting systems, including non-Markovian coupling to phonon degrees of freedom, under excitation by N-photon Fock state pulses. This method combines the input–output and the hierarchical equations of motion formalisms into a double hierarchy of density matrix equations. We show analytically that under weak field excitation relevant to natural photosynthesis conditions, an N-photon Fock state input and a corresponding coherent state input give rise to equal density matrices in the excited manifold. However, an N-photon Fock state input induces no off-diagonal coherence between the ground and excited subspaces, in contrast with the coherences created by a coherent state input. We derive expressions for the probability to absorb a single Fock state photon with or without the influence of phonons. For short pulses (or, equivalently, wide bandwidth pulses), we show that the absorption probability has a universal behavior that depends only upon a system-dependent effective energy spread parameter Δ and an exciton–light coupling constant Γ. This holds for a broad range of chromophore systems and for a variety of pulse shapes. We also analyze the absorption probability in the opposite long pulse (narrow bandwidth) regime. We then derive an expression for the long time emission rate in the presence of phonons and use it to study the difference between collective vs independent emission. Finally, we present a numerical simulation for the LHCII monomer (14-mer) system under single photon excitation that illustrates the use of the double hierarchy equations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of competition of spherical and deformed shells in quasifission of superheavy nuclei

Quasifission and fusion-fission represent the two most likely reaction outcomes to occur postcapture in collisions leading to superheavy nuclei. As such, understanding these mechanisms and how they relate to one another is key to understanding the intricate dynamics that drive the formation (or dissociation) of the nascent compound nuclei formed in fusion reactions. This understanding directly translates to a more informed picture of suitable reaction partners and can provide vital information for experimental efforts to study the physics and chemistry of superheavy elements. In this work we report results from time-dependent simulations of 48 Ca + 238 U and 50 Ti + 236 Th reactions at incident energies just above the Coulomb barrier with a focus on the quasifission process that prevent the formation of a fully equilibrated 286 Cn compound nucleus. We study these reactions systematically and consider a wide range of initial configurations to extract a robust estimate of primary fragment yields for the quasifission process. Multiple preferred exit channels are observed, with both spherical and deformed shell effects in the heavy and light fragments driving contributions to the production yields depending on the initial configuration of the system. Orientation effects of the deformed actinide targets are found to be a primary driver of which exit channels are populated. Here, the impact of moving away from a doubly magic projectile is explored with implications towards the reactions considered for current and future superheavy searches.

Gumbel, Richard [Michigan State University, East L↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

The Global Emergency Observation and Warning System

Based on an extensive characterization of natural hazards, and an evaluation of their impacts on humanity, a set of functional technical requirements for a global warning and relief system was developed. Since no technological breakthroughs are required to implement a global system capable of performing the functions required to provide sufficient information for prevention, preparedness, warning, and relief from natural disaster effects, a system is proposed which would combine the elements of remote sensing, data processing, information distribution, and communications support on a global scale for disaster mitigation.

Bukley, Angelia P.↗

Impact of Radiation Hardness and Operating Temperatures of Silicon Carbide Electronics on Space Power System Mass

The effect of silicon carbide (SiC) electronics operating temperatures on Power Management and Distribution (PMAD), or Power Conditioning (PC), subsystem radiator size and mass requirements was evaluated for three power output levels (100 kW(e) , 1 MW(e), and 10 MW(e)) for near term technology ( i.e. 1500 K turbine inlet temperature) Closed Cycle Gas Turbine (CCGT) power systems with a High Temperature Gas Reactor (HTGR) heat source. The study was conducted for assumed PC radiator temperatures ranging from 370 to 845 K and for three scenarios of electrical energy to heat conversion levels which needed to be rejected to space by means of the PC radiator. In addition, during part of the study the radiation hardness of the PC electronics was varied at a fixed separation distance to estimate its effect on the mass of the instrument rated reactor shadow shield. With both the PC radiator and the conical shadow shield representing major components of the overall power system the influence of the above on total power system mass was also determined. As expected, results show that the greatest actual mass savings achieved by the use of SiC electronics occur with high capacity power systems. Moreover, raising the PC radiator temperature above 600 K yields only small additional system mass savings. The effect of increased radiation hardness on total system mass is to reduce system mass by virtue of lowering the shield mass.

Juhasz, Albert J.↗

Effective mass of two-dimensional electrons in InGaAsN/GaAsSb type II quantum well by Shubnikov-de Haas oscillations

In order to develop optical devices for 2–3 μm wavelength regions, the InP-based InGaAs/GaAsSb type II multiple quantum well system has been investigated. By doping nitrogen into InGaAs layers, the system becomes effective in creating the optical devices with a longer wavelength. In this report, electrical transport properties are reported on the InGaAsN/GaAsSb type II system. The epitaxial layers with the single hetero or multiple quantum well structure on InP substrates are grown by the molecular beam epitaxy. The electrical resistance of samples with different nitrogen concentrations has been measured as a function of the magnetic field up to 9 Tesla at several temperatures between 2 and 6 K. The oscillation of the resistance due to the Shubnikov-de Haas (SdH) effect has been observed at each temperature. The effective mass is obtained from the temperature dependence of the amplitude of the SdH oscillations. The value of the effective mass increases from 0.048 for N = 0.0% to 0.062 for N = 1.2 and 1.5% as the nitrogen concentration increases. The mass enhancement occurs with corresponding to the reduction of the bandgap energy. These results are consistent with the band anticrossing model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Insights into Designing an Efficient and Reliable Microwave-Assisted Methane Dehydroaromatization Process: Effect of Microwave Absorber on Catalyst Performance

Microwave-assisted methane dehydroaromatization has the potential to address challenges of traditional dehydroaromatization reactions. However, catalysts for microwave-enhanced reaction systems require effective coupling of fields with the catalyst to produce heat and reach reaction temperatures. Here, this work presents an in-depth understanding of the effect of the addition of silicon carbide as a microwave absorber on catalyst performance among other variables, the viability of the microwave reactor configuration, and insights into designing an effective and reliable microwave-based methane dehydroaromatization process. The effect of other parameters including temperature, weight hourly space velocity, role of microwave absorber, and methane concentration during microwave-assisted methane dehydroaromatization reaction are studied. Mo/ZSM-5 was found to suffer from low permittivity and nonuniform heating under microwave conditions. Mixing silicon carbide powder as a microwave absorber with the catalyst was found to provide more uniform heating. When assessing the catalytic performance of the mixture, it was found that higher methane partial pressures at 2000 cc/g cat .h and a temperature range of 500-600°C produced the highest amount of benzene. The formation of graphitic carbon on the spent catalyst increased with temperature, gas-solid contact period, and methane concentration, which resulted in higher methane conversion and benzene selectivity. The study indicates that under microwave heating the presence of localized carbon enhanced catalyst life by coupling with microwave energy, leading to localized heating, and improving benzene selectivity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A computer software system for the generation of global ocean tides including self-gravitation and crustal loading effects

A computer software system is described which computes global numerical solutions of the integro-differential Laplace tidal equations, including dissipation terms and ocean loading and self-gravitation effects, for arbitrary diurnal and semidiurnal tidal constituents. The integration algorithm features a successive approximation scheme for the integro-differential system, with time stepping forward differences in the time variable and central differences in spatial variables. Solutions for M2, S2, N2, K2, K1, O1, P1 tidal constituents neglecting the effects of ocean loading and self-gravitation and a converged M2, solution including ocean loading and self-gravitation effects are presented in the form of cotidal and corange maps.

Estes, R. H.↗

Evaluating the Impact of Head Rotation Amplification on Virtual Reality Training Effectiveness

Virtual reality (VR) systems have been proposed for use in numerous training scenarios, such as room clearing, which require the trainee to maintain spatial awareness. But many VR training systems lack a fully surrounding display, requiring trainees to use a combination of physical and virtual turns to view the environment, thus decreasing spatial awareness. One solution to this problem is to amplify head rotations, such that smaller physical turns are mapped to larger virtual turns, allowing trainees to view the surrounding environment with head movements alone. For example, in a multi-monitor system covering only a 90-degree field of regard, head rotations could be amplified four times to allow the user to see the entire 360-degree surrounding environment. This solution is attractive because it can be used with lower-cost VR systems and does not require virtual turning. However, the effects of amplified head rotations on spatial awareness and training transfer are not well understood. We hypothesized that small amounts of amplification might be tolerable, but that larger amplifications might cause trainees to become disoriented and to have decreased task performance and training transfer. In this paper, we will present our findings from an experiment designed to investigate these hypotheses. The experiment placed users in a virtual warehouse and asked them to move from room to room, counting objects placed around them in space. We varied the amount of amplification applied during these trials, and also varied the type of display used (head-mounted display or CAVE). We measured task performance and spatial awareness. We then assessed training transfer in an assessment environment with a fully surrounding display and no amplification. The results of this study will inform VR training system developers about the potential negative effects of using head rotation amplification and contribute to more effective VR training system design.

3D interaction↗

Magnetic Field Effect on Convective Fluid Flow in a Vertical Bridgman System

We studied the magnetic field effects on convective fluid flow in a differentially heated HgCdTe Bridgman growth system with linearly stratified vertical HgTe concentration. We followed J. E. Hart's system set-up, boundary conditions, and formulation. We obtained analytical steady parallel flow solutions for fluid flow's velocity and solutal concentration. These solutions depend only on solutal Rayleigh number. Our analytical solutions had different expressions from that of Hart's, but had similar numerical simulation results for the mean fluid velocity and solutal concentration gradient as a function of solutal Rayleigh number. We studied the effects of a transverse magnetic field on the fluid flow of the Bridgman growth systems both on the ground and in the space. The simulation results and comparison with experimental results will be presented.

Wang, J. C.↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

Alpha-alpha scattering in the Multiverse

We investigate the phase shifts of low-energy α-α scattering under variations of the fundamental parameters of the Standard Model, namely the light quark mass, the electromagnetic fine-structure constant as well as the QCD θ-angle. As a first step, we recalculate α-α scattering in our Universe utilizing various improvements in the adiabatic projection method, which leads to an improved, parameter-free prediction of the S- and D-wave phase shifts for laboratory energies below 10 MeV. We find that positive shifts in the pion mass have a small effect on the S-wave phase shift, whereas lowering the pion mass adds some repulsion in the two-alpha system. The effect on the D-wave phase shift turns out to be more pronounced as signaled by the D-wave resonance parameters. Variations of the fine-structure constant have almost no effect on the low-energy α-α phase shifts. We further show that up-to-and-including next-to-leading order in the chiral expansion, variations of these phase shifts with respect to the QCD θ-angle can be expressed in terms of the θ-dependent pion mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cutaneous exposure to vesicant phosgene oxime: Acute effects on the skin and systemic toxicity

Phosgene Oxime (CX), an urticant or nettle agent categorized as a vesicant, is a potential chemical warfare and terrorist weapon. Its exposure can result in widespread and devastating effects including high mortality due to its fast penetration and ability to cause immediate severe cutaneous injury. It is one of the least studied chemical warfare agents with no effective therapy available. Thus, our goal was to examine the acute effects of CX following its cutaneous exposure in SKH-1 hairless mice to help establish a relevant injury model. Results from our study show that topical cutaneous exposure to CX vapor causes blanching of exposed skin with an erythematous ring, necrosis, edema, mild urticaria and erythema within minutes after exposure out to 8 h post-exposure. These clinical skin manifestations were accompanied with increases in skin thickness, apoptotic cell death, mast cell degranulation, myeloperoxidase activity indicating neutrophil infiltration, p53 phosphorylation and accumulation, and an increase in COX-2 and TNFα levels. Topical CX-exposure also resulted in the dilatation of the peripheral vessels with a robust increase in RBCs in vessels of the liver, spleen, kidney, lungs and heart tissues. These events could cause a drop in blood pressure leading to shock, hypoxia and death. Together, this is the first report on effects of CX cutaneous exposure, which could help design further comprehensive studies evaluating the acute and chronic skin injuries from CX topical exposure and elucidate the related mechanism of action to aid in the identification of therapeutic targets and mitigation of injury. - Highlights: • Phosgene oxime cutaneous exposure causes skin blanching, edema and urticaria. • Penetration of phosgene oxime causes dilation of vasculature in internal organs. • Mast cells could play an important role in phosgene oxime-induced skin injury. • Phosgene oxime could induce low blood pressure and hypoxia leading to mortality. • Data is significant for developing a phosgene oxime-induced skin injury model.

60 APPLIED LIFE SCIENCES↗

Online, real-time analysis of highly complex processing streams: Quantification of analytes in Hanford tank sample

Processing of hazardous materials is a crucial example of where on-line monitoring can significantly reduce operation risk, cost, and time. This is particularly true in the case of the Hanford site, where nuclear materials from the cold war era are being processed for environmental cleanup efforts. In exceedingly complex streams such as those at Hanford, on-line and real-time monitoring can be a challenge due to complexity of signals. Further obstacles are imposed by the caustic nature of processing streams as well as the radiation damage inflicted on instruments and probes. On-line monitoring based on Raman spectroscopy enables the detection of many Hanford tank species of interest, and was demonstrated here on nine chemical species that comprise the majority of tank waste by volume, including Al(OH)4-, C2O42-, CO32-, CrO42-, NO32-, NO3-, OH-, PO43-, SO42-. Real-time analysis of Raman signal allows for immediate quantification of target analytes and was successfully accomplished through the use of chemometric models. Furthermore, irradiation tests reveal Raman monitoring systems can effectively continue to operate even after receiving 1·107 Rad of gamma dose. The on-line, real-time monitoring system developed here was successfully used to simultaneously quantify nine target analytes in a real samples collected from Hanford tank AP-105.

Lines, Amanda M.↗

Refine your search to explore more results.