Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR PHASE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Multi-scale Control and Enhancement of Reactor Boiling Heat Flux by Reagents and Nanoparticles

The phenomenological characterization of the use of non-invasive and passive techniques to enhance the boiling heat transfer in water has been carried out in this extended study. It provides fundamental enhanced heat transfer data for nucleate boiling and discusses the associated physics with the aim of addressing future and next-generation reactor thermal-hydraulic management. It essentially addresses the hypothesis that in phase-change processes during boiling, the primary mechanisms can be related to the liquid-vapor interfacial tension and surface wetting at the solidliquid interface. These interfacial characteristics can be significantly altered and decoupled by introducing small quantities of additives in water, such as surface-active polymers, surfactants, and nanoparticles. The changes are fundamentally caused at a molecular-scale by the relative bulk molecular dynamics and adsorption-desorption of the additive at the liquid-vapor interface, and its physisorption and electrokinetics at the liquid-solid interface. At the micro-scale, the transient transport mechanisms at the solid-liquid-vapor interface during nucleation and bubblegrowth can be attributed to thin-film spreading, surface-micro-cavity activation, and micro-layer evaporation. Furthermore at the macro-scale, the heat transport is in turn governed by the bubble growth and distribution, macro-layer heat transfer, bubble dynamics (bubble coalescence, collapse, break-up, and translation), and liquid rheology. Some of these behaviors and processes are measured and characterized in this study, the outcomes of which advance the concomitant fundamental physics, as well as provide insights for developing control strategies for the molecular-scale manipulation of interfacial tension and surface wetting in boiling by means of polymeric reagents, surfactants, and other soluble surface-active additives.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CFD MODELING AND ANALYSIS FOR A-AREA AND H-AREA COOLING TOWERS

Mechanical draft cooling towers are designed to cool process water via sensible and latent heat transfer to air. Heat and mass transfer take place simultaneously. Heat is transferred as sensible heat due to the temperature difference between liquid and gas phases, and as the latent heat of the water as it evaporates. Mass of water vapor is transferred due to the difference between the vapor pressure at the air-liquid interface and the partial pressure of water vapor in the bulk of the air. Equations to govern these phenomena are discussed here. The governing equations are solved by taking a computational fluid dynamics (CFD) approach. The purpose of the work is to develop a three-dimensional CFD model to evaluate the flow patterns inside the cooling tower cell driven by cooling fan and wind, considering the cooling fans to be on or off. Two types of the cooling towers are considered here. One is cross-flow type cooling tower located in A-Area, and the other is counterflow type cooling tower located in H-Area. The cooling tower located in A-Area is mechanical draft cooling tower (MDCT) consisting of four compartment cells as shown in Fig. 1. It is 13.7m wide, 36.8m long, and 9.4m high. Each cell has its own cooling fan and shroud without any flow communications between two adjacent cells. There are water distribution decks on both sides of the fan shroud. The deck floor has an array of about 25mm size holes through which water droplet falls into the cell region cooled by the ambient air driven by fan and wind, and it is eventually collected in basin area. As shown in Fig. 1, about 0.15-m thick drift eliminator allows ambient air to be humidified through the evaporative cooling process without entrainment of water droplets into the shroud exit. The H-Area cooling tower is about 7.3 m wide, 29.3 m long, and 9.0 m high. Each cell has its own cooling fan and shroud, but each of two corner cells has two panels to shield wind at the bottom of the cells. There is some degree of flow communications between adjacent cells through the 9-in gap at the bottom of the tower cells as shown in Fig. 2. Detailed geometrical dimensions for the H-Area tower configurations are presented in the figure. The model was benchmarked and verified against off-site and on-site test results. The verified model was applied to the investigation of cooling fan and wind effects on water cooling in cells when fans are off and on. This report will discuss the modeling and test results.

42 ENGINEERING↗

INVESTIGATION OF TURBULENT JETS, SPRAYS, AND SUPERCRITICAL MIXING BY TIME RESOLVED RAINBOW SCHLIEREN DEFLECTOMETRY

As technological advancements have enabled higher efficiency compression ignition (CI) engines (diesel engines) by operating at higher pressures and temperatures, the mechanisms of fuel-air mixing are postulated to change. Thus, there is a greater need for experimental data to develop and verify new phenomena. However, the fast time scales and harsh environments associated with CI engines present many experimental difficulties and requires high quality non-intrusive diagnostics to obtain useful data. The diagnostics itself must be validated prior to its implementation in an engine environment. The purpose of this research is to advance rainbow schlieren deflectometry (RSD) to study turbulent fuel sprays including the effects of supercritical mixing in CI engine environments. This objective is met by developing and applying quantitative RSD, for the first time, to three separate aspects of fuel sprays: 1) turbulent mixing, 2) phase boundaries, and 3) non-ideal gas mixing. First, quantitative RSD is demonstrated for turbulent mixing in a canonical helium jet. Rayleigh scattering data in the literature is used to validate the concentration measurements obtained by RSD. The results also provide explanations for phenomena occurring in the helium jet and provide data not yet present in the literature. Second, RSD is applied to high pressure multi-phase fuel sprays and new methodologies are developed to distinguish the liquid region from the vapor region and to quantify the in-between region on a probabilistic basis. Isolating liquid and vapor regions generally requires two separate diagnostics, e.g., Mie scattering (liquid region) and Rayleigh scattering (vapor region). However, the results of this study demonstrate that RSD can be used as a single diagnostic to measure both liquid and vapor boundaries. Third, the optical-to-thermodynamic relations associated with refrac-tometry are investigated under non-ideal gas mixing conditions to develop a generalized relationship valid for both ideal or non-ideal gas mixing. The last part of this research develops the theoretical tools to understand and experimentally realize supercritical mixing at diesel conditions. Guided by the theoretical analysis, RSD is applied to compare supercritical versus transcritical mixing at CI conditions using a constant pressure test rig. It is found that while fully supercritical mixing ers benefits in diesel engines, i.e, faster mixing times (50% higher velocities), the absence of droplets which cause high levels of particulate emissions, etc., it would be difficult to achieve in practice because of the requirements of fuels with low critical temperature and/or substantial fuel preheating.

02 PETROLEUM↗

Structural and optical properties of electron beam evaporated yttria stabilized zirconia thin films

Yttria stabilized zirconia (10 mole % Y{sub 2}O{sub 3}) thin films were deposited on quartz substrates using electron beam physical vapor deposition at the substrate temperatures in the range 300 – 973 K. XRD analysis showed cubic crystalline phase of YSZ films with preferred orientation along (111). The surface roughness was found to increase with the increase of deposition temperatures. The optical band gap of ∼5.7 eV was calculated from transmittance curves. The variation in the optical properties is correlated with the changes in the microstructural features of the films prepared as a function of substrate temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enabling 6.5% Silicon Electric Steel for Motor Application

Compared to the most widely used 3.2% Si steel, 6.5% Si steel exhibits superior magnetic and electric properties and promises an improvement to the efficiency and power density of electrical machines and transformers. However, due to the heterogeneous formation of B2 and D03 ordered phases, 6.5% Si steel is too brittle to be produced using the traditional cold roll process. And the thin sheet obtained via Si vapor deposition followed by diffusion process is difficult to stamp and assemble. At Iowa State University and Ames Laboratory, a novel process was developed to enable the cost-effective deployment of this brittle materials. The process is developed based on the observation that the deleterious ordered phases can be fully or partially suppressed by rapid cooling. The innovation lies in the production of small ductile flakes using rapid solidification and the consolidation of the obtained flakes directly into a fully dense part with near-net-shape.

36 MATERIALS SCIENCE↗

Efficient reflection via four-wave mixing in a Doppler-free electromagnetically-induced-transparency gas system

We experimentally demonstrate the high-efficiency reflection of a probe field in {Lambda}-type three-level atoms of cesium vapor driven by two counterpropagating coupling fields. More than 60% of reflection efficiency is observed at the phase-matching angle. The underlying mechanism theoretically is investigated as the four-wave mixing is enhanced by the electromagnetically-induced transparency. Both of the two Doppler-free two-photon resonances (one for the probe and co-propagating fields, the other for the reflected and the counterpropagation fields) play an important role in satisfying the phase matching in the reflection direction. The phase compensation due to the anomalous dispersion and the decrease of effective absorption length in the atomic system allow the efficient reflection to be observed in a wide range of incident angles of the probe field and detunings of the coupling field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermochemically Driven Gas-Dynamic Fracturing (TDGF)

This report concerns efforts to increase oil well productivity and efficiency via a method of heating the oil-bearing rock of the well, a technique known as Thermochemical Gas-Dynamic Fracturing (TGDF). The technique uses either a chemical reaction or a combustion event to raise the temperature of the rock of the well, thereby increasing oil velocity, and oil pumping rate. Such technology has shown promise for future application to both older wellheads and also new sites. The need for such technologies in the oil extraction field, along with the merits of the TGDF technology is examined in Chapter 1. The theoretical basis underpinning applications of TGDF is explained in Chapter 2. It is shown that productivity of depleted well can be increased by one order of magnitude after heating a reservoir region of radius 15-20 m around the well by 100 degrees 1-2 times per year. Two variants of thermal stimulation are considered: uniform heating and optimal temperature distribution in the formation region around the perforation zone. It is demonstrated that the well productivity attained by using equal amounts of thermal energy is higher by a factor of 3 to 4 in the case of optimal temperature distribution as compared to uniform distribution. Following this theoretical basis, two practical approaches to applying TDGF are considered. Chapter 3 looks at the use of chemical intiators to raise the rock temperature in the well via an exothermic chemical reaction. The requirements for such a delivery device are discussed, and several novel fuel-oxidizing mixtures (FOM) are investigated in conditions simulating those at oil-extracting depths. Such FOM mixtures, particularly ones containing nitric acid and a chemical initiator, are shown to dramatically increase the temperature of the oil-bearing rock, and thus the productivity of the well. Such tests are substantiated by preliminary fieldwork in Russian oil fields. A second, more cost effective approach to TGDF is considered in Chapter 4: use of diesel-fuel to raise the rock temperature by a combustion process in the well. The requirements for such a Gas-Vapor Generator are laid out, and the development of a prototype machine is explained. This is backed up with laboratory experiments showing that the fuel-water mixture used does significantly increase the viscosity of the oil samples. The prototype Gas-Vapor Generator is shown to be able to operate at temperatures of 240 C and pressures of 200 atm. Unfortunately, geopolitical and economic factors outside of our control led to the cancellation of the project before the field testing phase of the generator could be commenced. Nevertheless, it is to be hoped that this report demonstrates both the feasibility and desirability of the Gas-Vapor Generator approach to the application of TDGF technology in both existing and new wells, and provides a foundation for further research in the future.

02 PETROLEUM↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Post-Deposition Recrystallization of Co-Evaporated CuIn x Ga (1-x) Se 2 Films by Bromide Vapor Treatments

CIGS films deposited at 400°C onto molybdenum-coated soda-lime glass substrates by co-evaporation were annealed in InBr 3 vapors or CuBr with Se vapors. The treatments were conducted at 400°C, 450°C, or 500°C for one hour. The InBr 3 treatments above 400°C and CuBr with Se treatments at 500°C resulted in increased grain size, improved crystallinity, and a decrease in Cu 2 Se phase. Annealed samples also exhibited large surface facets. CIGS films deposited at 350°C were also investigated in InBr 3 and CuBr with Se vapors at 450°C for one hour. Furthermore, these treatments resulted in increased grain size and less deviations from the as-deposited composition.

14 SOLAR ENERGY↗

STAR-CCM+ Verification and Validation Plan

The commercial Computational Fluid Dynamics (CFD) code STAR-CCM+ provides general purpose finite volume method solutions for fluid dynamics and energy transport. This document defines plans for verification and validation (V&V) of the base code and models implemented within the code by the Consortium for Advanced Simulation of Light water reactors (CASL). The software quality assurance activities described herein are port of the overall software life cycle defined in the CASL Software Quality Assurance (SQA) Plan [Sieger, 2015]. STAR-CCM+ serves as the principal foundation for development of an advanced predictive multi-phase boiling simulation capability within CASL. The CASL Thermal Hydraulics Methods (THM) team develops advanced closure models required to describe the subgrid-resolution behavior of secondary fluids or fluid phases in multiphase boiling flows within the Eulerian-Eulerian framework of the code. These include wall heat partitioning models that describe the formation of vapor on the surface and the forces the define bubble/droplet dynamic motion. The CASL models are implemented as user coding or field functions within the general framework of the code. This report defines procedures and requirements for V&V of the multi-phase CFD capability developed by CASL THM. Results of V&V evaluations will be documented in a separate STAR-CCM+ V&V assessment report. This report is expected to be a living document and will be updated as additional validation cases are identified and adopted as part of the CASL THM V&V suite.

97 MATHEMATICS AND COMPUTING↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Surface nanostructuring in the carbon–silicon(100) system upon microwave plasma treatment

The study is concerned with the physical and chemical processes and the mechanisms of the effect of plasma preparation of a surface on the systematic features of condensation and surface phase transformations during the formation of Si–C mask domains on p-Si(100) crystals by the deposition of submonolayer C coatings in the microwave plasma of low-pressure ethanol vapors. It is shown that, at short durations of the deposition of carbon onto silicon wafers with a natural-oxide coating at a temperature of 100°C, the formation of domains is observed. The lateral dimensions of the domains lie in the range from 10–15 to 200 nm, and the heights of ridges produced by the plasma chemical etching of silicon through the mask domain coatings vary in the range from 40 to 80 nm.

36 MATERIALS SCIENCE↗

Ice formation on nitric acid coated dust particles: Laboratory and modeling studies

Changes in the ice nucleation characteristics of atmospherically relevant mineral dust particles due to nitric acid coating are not well understood. Further, the atmospheric implications of dust coating on ice-cloud properties under different assumptions of primary ice nucleation mechanisms are unknown. We investigated ice nucleation ability of Arizona test dust, illite, K-feldspar and quartz as a function of temperature (-25 to -30°C) and relative humidity with respect to water (75 to 110%). Particles were size selected at 250 nm and transported (bare or coated) to the ice nucleation chamber to determine the fraction of particles nucleating ice at various temperature and water saturation conditions. All dust nucleated ice at water-subsaturated conditions, but the coated particles showed a reduction in their ice nucleation ability compared to bare particles. However, at water-supersaturated conditions, we observed that bare and coated particles had nearly similar ice nucleation characteristics. X-ray diffraction patterns indicated that structural properties of bare dust particles modified after acid treatment. We found that lattice parameters were slightly different, but crystallite sizes of the coated particles were reduced compared to bare particles. Next, single-column model results show that simulated ice crystal number concentrations mostly depends upon fraction of particles that are coated, primary ice nucleation mechanisms, and the competition between ice nucleation mechanisms to nucleate ice. In general, we observed that coating modify the ice-cloud properties and the picture of ice and mixed-phase cloud evolution is complex when different primary ice nucleation mechanisms are competing for fixed water vapor mass.

Environmental Molecular Sciences Laboratory↗

Gas-Phase Temperature Mapping of Evaporating Microdroplets

Evaporation is a ubiquitous and complex phenomenon of importance to many natural and industrial systems. Evaporation occurs when molecules near the free interface overcome intermolecular attractions with the bulk liquid. As molecules escape the liquid phase, heat is removed, causing evaporative cooling. The influence of evaporative cooling on inducing a temperature difference with the surrounding atmosphere as well as within the liquid is poorly understood. Here, we develop a technique to overcome past difficulties encountered during the study of heterogeneous droplet evaporation by coupling a piezo-driven droplet generation mechanism to a controlled micro-thermocouple to probe microdroplet evaporation. The technique allowed us to probe the gas-phase temperature distribution using a micro-thermocouple (50 μm) in the vicinity of the liquid–vapor interface with high spatial (±10 μm) and temporal (±100 ms) resolution. We experimentally map the temperature gradient formed surrounding sessile water droplets having varying curvature dictated by the apparent advancing contact angle (100° ≲ θ ≲ 165°). The experiments were carried out at temperatures below and above ambient for a range of fixed droplet radii (130 μm ≲ R ≲ 330 μm). Our results provide a primary validation of the centuries-old theoretical framework underpinning heterogeneous droplet evaporation mediated by the working fluid, substrate, and gas thermophysical properties, droplet apparent contact angle, and droplet size. We show that microscale droplets residing on low-thermal-conductivity substrates such as glass absorb up to 8× more heat from the surrounding gas compared to droplets residing on high-thermal-conductivity substrates such as copper. Finally, our work not only develops an experimental understanding of the heat transfer mechanisms governing droplet evaporation but also presents a powerful platform for the study and characterization of liquid–vapor transport at curved interfaces wetting and nonwetting advanced functional surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical Breakdown of Suspended Mono- and Few-Layer Tungsten Disulfide via Sulfur Depletion Identified by in Situ Atomic Imaging

The high bias behavior of mono- and few-layer WS2 is explored by in situ aberration corrected transmission electron microscopy (AC-TEM). The suspended WS2 devices were found to undergo irreversible breakdown at sufficiently high biases, however simultaneous to the removal of WS2 was the accompanying formation of few-layer graphene decorated with W and WS2 nanoparticles. The breakdown of few-layer WS2 resulted in the formation of facetted S-depleted WS2 tendrils along the vaporization boundary, which were found to exhibit lattice contraction indicative of S depletion, alongside pure W phases incorporated into the structure, with the interfaces imaged at atomic resolution. The combination of observing; graphitization of the amorphous carbon surface residue, W nanoparticles, and S depleted WS2 phases, following the high-bias WS2 disintegration all indicate a thermal Joule heating breakdown mechanism over an avalanche process. The observation of graphene formation, and the role the thin amorphous carbon layer has in the pre-breakdown behavior of the device, demonstrate the importance of employing encapsulated heterostructure device architectures that exclude residues.

Fan, Ye↗

Lateral gas phase diffusion length of boron atoms over Si/B surfaces during CVD of pure boron layers

The lateral gas phase diffusion length of boron atoms, L{sub B}, along silicon and boron surfaces during chemical vapor deposition (CVD) using diborane (B{sub 2}H{sub 6}) is reported. The value of L{sub B} is critical for reliable and uniform boron layer coverage. The presented information was obtained experimentally and confirmed analytically in the boron deposition temperature range from 700 °C down to 400 °C. For this temperature range the local loading effect of the boron deposition is investigated on the micro scale. A L{sub B} = 2.2 mm was determined for boron deposition at 700 °C, while a L{sub B} of less than 1 mm was observed at temperatures lower than 500 °C.

36 MATERIALS SCIENCE↗

Refine your search to explore more results.