Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Experimental Validation of Calorimetric Electron Capture Spectral Theory with 193 Pt

Using microcalorimeters, a high statistics, high-resolution calorimetric spectrum of electron capture in 163 Ho can be used to determine the neutrino mass. The spectral shape can be calculated from first principles with various assumptions and approximations. To determine the validity of these choices, the theoretical calculations must be compared to data from multiple isotopes. In this work, new calorimetric data for a 193 Pt-in-Pt absorber measured with a transition edge sensor are presented and compared to theoretical calculations and values from the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the Validity of Linear Response Theory in High-Dimensional Deterministic Dynamical Systems

This theoretical work considers the following conundrum: linear response theory is successfully used by scientists in numerous fields, but mathematicians have shown that typical low-dimensional dynamical systems violate the theory’s assumptions. Here we provide a proof of concept for the validity of linear response theory in high-dimensional deterministic systems for large-scale observables. We introduce an exemplary model in which observables of resolved degrees of freedom are weakly coupled to a large, inhomogeneous collection of unresolved chaotic degrees of freedom. By employing statistical limit laws we give conditions under which such systems obey linear response theory even if all the degrees of freedom individually violate linear response. We corroborate our result with numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Feature-Based Stochastic Permeability of Shale: Part 1—Validation and Two-Phase Permeability in a Utica Shale Sample

Estimate of permeability plays a crucial role in flow-based studies of fractured tight-rocks. It is well known that most of the flow through tight-rocks (e.g., shales) is controlled by permeable features (e.g., fractures, laminations, etc.), and there is negligible flow through the matrix. However, current approaches in the literature to model permeability of tight-rocks do not account for such features present within the rock ranging from micro-scale to field-scale. Current permeability modeling approach assumes a single continuum without considering the presence of permeable features within the matrix (e.g., micro-fractures) or outside the matrix (e.g., natural fractures). Although the laboratory-measured permeability implicitly captures discrete features present in that sample (e.g., fractures, laminations, micro-fractures), most of the permeability models proposed for shale do not account for these features. Fracture permeability in the literature is typically modeled using an ideal slit assumption; however, this highly overestimates its permeability because fractures in real medium are non-ideal in terms of their porosity and tortuosity, which affect their permeability. Additionally, the transition zone between fracture and matrix also affects the permeability of fracture. Here in this study, part of a two-part series, a new method to predict permeability of fractured shale by discretizing the medium into matrix (inorganic and organic) and fractures is presented. New analytical expressions of permeability are derived to account for non-ideal nature of porous medium and two-phase flow in fractures. Rock feature in each cell of the grid is identified as one of the three elements (organic matter, inorganic matter, or fracture), and permeability of that cell is estimated using a suitable analytical expression. This method allows estimating permeability at any scale of interest and more robustly than by a pure analytical approach. The proposed method is validated against local and global-scale measurements on three fractured samples from laboratory. Finally, the method is used to predict two-phase flow permeability of supercritical CO 2 displacing water within a fracture in a Utica shale sample. The proposed two-phase flow permeability equations can be used as a quick analytical tool to predict relative permeability estimates of two-phase flow in fractured shale samples. In Part 2, the proposed method is used to estimate field-scale permeability through an optimization process that uses field-scale production and other readily available information.

58 GEOSCIENCES↗

Experimental Validation of Numerical Simulations of a New-Generation NiTi Endodontic File Under Bending

The superelasticity of NiTi shape memory alloy has been used in endodontics since the 1990s. To study the mechanical behavior of endodontic instruments, a traditional approach consists in experimental investigations. However, finite element analysis constitutes another way to assess their mechanical behavior and to facilitate their design. The main aim of this study is to compare experimental and numerical bending results on different structures (NiTi wire, spreader, and instruments) to estimate the reliability of the finite element simulations. These investigations were carried out as follows. Firstly, experimental material parameters identification was performed using NiTi wires. These parameters were implemented in an appropriate NiTi model. Bending was numerically applied to the meshed structures generated by the finite element method. Experimental tests were performed on real structures under bending, with exactly the same loading, in order to compare experimental and numerical results. These results were in good agreement for each of the considered structures. This enabled the validation of the simulation results and the use of simulations to design new endodontic instruments.

36 MATERIALS SCIENCE↗

Interface-Driven Plasticity in Metal–Ceramic Nanolayered Composites: Direct Validation of Multiscale Deformation Modeling via In Situ Indentation in TEM

Here, we present in situ indentation in a transmission electron microscope on Al-TiN multilayers with individual layer thicknesses of 50 nm and 2.7 nm to explore the effect of length scales on the plastic co-deformability of a metal and a ceramic. At 50 nm, plasticity was confined to the Al layers with brittle fracture in the TiN layers. At 5 nm and below, cracking in TiN was suppressed with co-deformation evident in both layers. The in situ transmission electron microscopy (TEM) straining results demonstrate a profound size effect in enhancing plastic co-deformability in nanoscale metal-ceramic multilayers, as well as direct validation of ex situ and 3-D elastic–plastic deformation models.

36 MATERIALS SCIENCE↗

Validating a Model for Welding Induced Residual Stress Using High-Energy X-ray Diffraction

Integrated computational materials engineering (ICME) provides a pathway to advance performance in structures through the use of physically-based models to better understand how manufacturing processes influence product performance. As one particular challenge, consider that residual stresses induced in fabrication are pervasive and directly impact the life of structures. For ICME to be an effective strategy, it is essential that predictive capability be developed in conjunction with critical experiments. In the present paper, simulation results from a multi-physics model for gas metal arc welding are evaluated through x-ray diffraction using synchrotron radiation. A test component was designed with intent to develop significant gradients in residual stress, be representative of real-world engineering application, yet remain tractable for finely spaced strain measurements with positioning equipment available at synchrotron facilities. Finally, the experimental validation lends confidence to model predictions, facilitating the explicit consideration of residual stress distribution in prediction of fatigue life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99m Tc-tetrofosmin: Method and validation

The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

60 APPLIED LIFE SCIENCES↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron microscopy holdings of the Protein Data Bank: the impact of the resolution revolution, new validation tools, and implications for the future

Abstract As a discipline, structural biology has been transformed by the three-dimensional electron microscopy (3DEM) “Resolution Revolution” made possible by convergence of robust cryo-preservation of vitrified biological materials, sample handling systems, and measurement stages operating a liquid nitrogen temperature, improvements in electron optics that preserve phase information at the atomic level, direct electron detectors (DEDs), high-speed computing with graphics processing units, and rapid advances in data acquisition and processing software. 3DEM structure information (atomic coordinates and related metadata) are archived in the open-access Protein Data Bank (PDB), which currently holds more than 11,000 3DEM structures of proteins and nucleic acids, and their complexes with one another and small-molecule ligands (~ 6% of the archive). Underlying experimental data (3DEM density maps and related metadata) are stored in the Electron Microscopy Data Bank (EMDB), which currently holds more than 21,000 3DEM density maps. After describing the history of the PDB and the Worldwide Protein Data Bank (wwPDB) partnership, which jointly manages both the PDB and EMDB archives, this review examines the origins of the resolution revolution and analyzes its impact on structural biology viewed through the lens of PDB holdings. Six areas of focus exemplifying the impact of 3DEM across the biosciences are discussed in detail (icosahedral viruses, ribosomes, integral membrane proteins, SARS-CoV-2 spike proteins, cryogenic electron tomography, and integrative structure determination combining 3DEM with complementary biophysical measurement techniques), followed by a review of 3DEM structure validation by the wwPDB that underscores the importance of community engagement.

Burley, Stephen K. (ORCID:0000000224879713)↗

Analytical Validation of a Portable Mass Spectrometer Featuring Interchangeable, Ambient Ionization Sources for High Throughput Forensic Evidence Screening

Forensic evidentiary backlogs are indicative of the growing need for cost-effective, high-throughput instrumental methods. One such emerging technology that shows high promise in meeting this demand while also allowing on-site forensic investigation is portable mass spectrometric (MS) instrumentation, particularly that which enables the coupling to ambient ionization techniques. While the benefits of rapid, on-site screening of contraband can be anticipated, the inherent legal implications of field-collected data necessitates that the analytical performance of technology employed be commensurate with accepted techniques. To this end, comprehensive analytical validation studies are required before broad incorporation by forensic practitioners can be considered, and are the focus of this work. Pertinent performance characteristics such as throughput, selectivity, accuracy/precision, method robustness, and ruggedness have been investigated. Reliability in the form of false positive/negative response rates is also assessed, examining the effect of variables such as user training and experience level. To provide flexibility toward broad chemical evidence analysis, a suite of rapidly-interchangeable ion sources has been developed and characterized through the analysis of common illicit chemicals and emerging threats like substituted phenethylamines. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry

Using contemporary theory for ion mobility spectrometry (IMS), gas-phase ion mobilities within a trapped ion mobility-mass spectrometer (TIMS) are not easily deduced using first principle equations due to non-linear pressure changes and consequently variations in E/N. It is for this reason that prior literature values have traditionally been used for TIMS calibration. Additionally, given that verified mobility standards currently do not exist and the that the exact conditions used to measure reported literature values may not always represent the environment within the TIMS, a direct approach to validating the behavior of the TIMS system is warranted. A calibration procedure is presented where an ambient pressure, ambient temperature, two-gate, printed circuit board drift-tube IMS (PCBIMS) is coupled to the front of a TIMS allowing reduced mobilities to be directly measured on the same instrument as the TIMS. These measured mobilities were used to evaluate the TIMS calibration procedure which correlates reduced mobility and TIMS elution voltages with literature values. When using the measured PCBIMS-reduced mobilities of tetraalkyl ammonium salts and tune mix for TIMS calibration of the alkyltrimethyl ammonium salts, the percent error is less than 1% as compared with using the reported literature K{sub 0} values where the percent error approaches 5%. This method provides a way to obtain accurate reference mobilities for ion mobility techniques that require a calibration step (i.e., TIMS and TWAVE). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of a Tapered Impact Damper for Traffic Signal Structure Vibrations Using the Method of Harmonic Balance

Significant vibration amplitudes and cycles can be produced when traffic signal structures with low inherent damping are excited near one of their natural frequencies. For the mitigation of wind-induced vibrations, dynamic vibration absorbers coupled to the structure are often used. Here, this research investigates the performance of a tapered impact damper, consisting of a hanging spring-mass oscillator inside a housing capable of reducing vibration amplitude over a broader frequency range than the conventional tuned mass damper. A nonlinear, two degree-of-freedom model is developed with coordinates representing the traffic structure and the tapered impact damper. This research focuses on the application of the harmonic balance method to approximate the periodic solutions of the nonlinear equations to compute the nonlinear dynamics of the damped traffic signal structure. After designing and manufacturing a tapered impact damper, the traffic signal structure is tested with and without the damper using free vibration snapback tests. The experimental frequency and damping backbone curves are used to validate the analytical model, and the effectiveness of the damper is discussed.

42 ENGINEERING↗

Fundamental microscopic properties as predictors of large-scale quantities of interest: Validation through grain boundary energy trends

Correlations between fundamental microscopic properties computable from first principles, which we term canonical properties, and complex large-scale quantities of interest (QoIs) provide an avenue to predictive materials discovery. Here, we propose that such correlations can be efficiently discovered through simulations utilizing approximate interatomic potentials (IPs), which serve as an ensemble of “synthetic materials”. As a proof of principle we build a regression model relating canonical properties to the symmetric tilt grain boundary (GB) energy curves in face-centered cubic crystals, characterized by the scaling factor in the universal lattice matching model of Runnels et al. (2016), which we take to be our QoI. Our analysis recovers known correlations of GB energy to other properties and discovers new ones. We also demonstrate, using available density functional theory (DFT) GB energy data, that the regression model constructed from IP data is consistent with DFT results, confirming the assumption that the IPs and DFT belong to same statistical pool and thereby validating the approach. Regression models constructed in this fashion can be used to predict large-scale QoIs based on first-principles data and provide a general method for training IPs for QoIs beyond the scope of first-principles calculations.

36 MATERIALS SCIENCE↗

Grain boundary segregation in BCC vanadium-based alloys: Quantum-accurate computed segregation spectra and targeted experimental validations

Grain boundaries are critically important to the material performance of fusion reactor materials such as vanadium, particularly mechanical properties and irradiation resistance. A key challenge to the design and control of grain boundaries in vanadium alloys is the lack of quantitative data on grain boundary segregation. In this study, we combine computational and experimental methods to address this gap. Furthermore, using a machine learning-accelerated quantum mechanics/molecular mechanics approach, we calculated the segregation spectra for 28 transition metal elements in polycrystalline vanadium, and validated these predictions experimentally for a subset of solutes that sample a range of segregation behavior, specifically zirconium, titanium, and tungsten, using analytical transmission electron microscopy. Furthermore, the agreement between experiment and theory highlights the predictive capability of our approach. Critically, this work provides a comprehensive database of quantum-accurate solute segregation enthalpies in vanadium, enabling the development of advanced alloys for fusion reactors applications.

Fusion materials↗

Verification and validation of a rapid heat transfer calculation methodology for transient melt pool solidification conditions in powder bed metal additive manufacturing

A fundamental understanding of spatial and temporal thermal distributions is crucial for predicting solidification and solid-state microstructural development in parts made by additive manufacturing. While sophisticated numerical techniques that are based on finite element or finite volume methods are useful for gaining insight into these phenomena at the length scale of the melt pool (100 - 500 µm), they are ill-suited for predicting engineering trends over full part cross-sections (> 10 x 10 cm) or many layers over long process times (> many days) due to the necessity of fully resolving the heat source characteristics. On the other hand, it is extremely difficult to resolve the highly dynamic nature of the process using purely in-situ characterization techniques. This article proposes a pragmatic alternative based on a semi-analytical approach to predicting the transient heat conduction during powder bed metal additive manufacturing process. The model calculations were theoretically verified for selective laser melting of AlSi10Mg and electron beam melting of IN718 powders for simple cross-sectional geometries and the transient results are compared to steady state predictions from the Rosenthal equation. It is shown that the transient effects of the scan strategy create significant variations in the melt pool geometry and solid-liquid interface velocity, especially as the thermal diffusivity of the material decreases and the pre-heat of the process increases. With positive verification of the strategy, the model was then experimentally validated to simulate two point-melt scan strategies during electron beam melting of IN718, one intended to produce a columnar and one an equiaxed grain structure. Lastly, through comparison of the solidification conditions (i.e. transient and spatial variations of thermal gradient and liquid-solid interface velocity) predicted by the model to phenomenological CET theory, the model accurately predicted the experimental grain structures.

36 MATERIALS SCIENCE↗

Validation of energy moments from the one-dimensional energy dependent neutron diffusion equation, MCNP5 and Attila-7.1.0 with the GODIVA experiment

Normalized neutron energy moments (moments) from the one-dimensional energy dependent neutron diffusion equation (EDNDE), Monte Carlo N Particle 5 version 1.40 (MCNP5) and Attila-7.1.0-beta version (Attila) are validated with the GODIVA experiment (GODIVA). Energy moments 0–5 for all three methods are compared to GODIVA moments. GODIVA moments are measured with two methods. The 1st method is a time of flight (T-O-F) measurement of the average energy (moment 1) of the leaking neutrons from the surface of GODIVA and the 2nd method is from back calculating moments from foil activation analysis of various metal foils at the center of GODIVA. The error range of the EDNDE normalized moments compared to GODIVA is from 0% to 24%. The MCNP5 error range compared to GODIVA is 0–12% and the Attila error range is 0–79%. The method of moments is shown to be a fast reliable method, compared to either Monte Carlo methods (MCNP5) or 30 multi-energy group methods (Attila) with regard to the GODIVA experiment.

99 GENERAL AND MISCELLANEOUS↗

Refine your search to explore more results.