Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceleration factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Hardware-Accelerated Ray Tracing of CAD-Based Geometry for Monte Carlo Radiation Transport

Monte Carlo radiation transport (MCRT) methods have been used to simulate radiation environments for many decades by tracking individual particles through a model to accumulate statistical information. MCRT geometry is historically formed using the constructive solid geometry (CSG). Recently, significant work has been performed to support simulations using computer-aided design (CAD)-based tessellated surfaces to support highly complex geometries. Ray tracing acceleration data structures from the rendering and visualization community are applied to accelerate particle tracking in CAD-based models. Despite these efforts, CSG representations provide the superior performance in surface intersection operations during particle flight. Concurrently, pseudo Monte Carlo methods have become prevalent in rendering applications to support more realistic models for scattering media, motivating innovations that are advantageous for MCRT simulations. Finally, the authors’ work extends these innovations by employing Intel’s Embree ray tracing kernel within a geometry toolkit for Monte Carlo to improve the simulation performance using CAD-based models by factors of 1.5 to 2.

42 ENGINEERING↗

Mice Drawer System

The Mice Drawer System (MDS) is an Italian Space Agency (ASI) facility which is able to support mice onboard the International Space Station during long-duration exploration missions (from 100 to 150-days) by living space, food, water, ventilation and lighting. Mice can be accommodated either individually (maximum 6) or in groups (4 pairs). MDS is integrated in the Space Shuttle middeck during transportation (uploading and downloading) to the ISS and in an EXPRESS Rack in Destiny, the US Laboratory during experiment execution. Osteoporosis is a debilitating disease that afflicts millions of people worldwide. One of the physiological changes experienced by astronauts during space flight is the accelerated loss of bone mass due to the lack of gravitational loading on the skeleton. This bone loss experienced by astronauts is similar to osteoporosis in the elderly population. MDS will help investigate the effects of unloading on transgenic (foreign gene that has been inserted into its genome to exhibit a particular trait) mice with the Osteoblast Stimulating Factor-1, OSF-1, a growth and differentiation factor, and to study the genetic mechanisms underlying the bone mass pathophysiology. MDS will test the hypothesis that mice with an increased bone density are likely to be more protected from osteoporosis, when the increased bone mass is a direct effect of a gene involved in skeletogenesis (skeleton formation). Osteoporosis is a debilitating disease that afflicts millions worldwide. One of the physiological changes experienced by astronauts during space flight is the accelerated loss of bone mass due to the lack of gravitational loading on the skeleton, a loss that is similar to osteoporosis in the elderly population on Earth. Osteoblast Stimulating Factor-1 (OSF-1), also known as pleiotrophin (PTN) or Heparin-Binding Growth- Associated Molecule (HB-GAM) belongs to a family of secreted heparin binding proteins..OSF-1 is an extracellular matrix-associated growth and differentiation factor that is normally expressed in cartilage; it can stimulate the proliferation and differentiation of human osteoprogenitor cells (cell that differentiate into an osteoblast) in vitro. The Mice Drawer System will study the effects of microgravity on transgenic mouse bones in order to identify genetic mechanisms playing a role in the reduction of the bone mass observed in humans and animals as a consequence of long-duration (greater than 100 days) microgravity exposure. Onboard the ISS, MDS is relatively self-sufficient; a crewmember will check the health status of the rodents on a daily basis, by assessing them through the viewing window. Water levels will be assessed by the crew daily and refilled as needed. Replacement of the food bars and replacement of the waste filters will be conducted inflight by crewmembers every 20-days.

Cancedda, Ranieri↗

Splitting amplitudes at N 3 LO in QCD

In the limit where partons become collinear to each other, scattering amplitudes factorize into a product of universal, process-independent building blocks and scattering amplitudes involving fewer partons. We compute these universal building blocks — known as splitting amplitudes — for two collinear QCD partons up to third loop order in QCD. Our results describe arbitrary time-like splitting processes. Due to the violation of strict collinear factorization in space-like splitting processes, we specifically present space-like splitting amplitudes for three-parton QCD scattering amplitudes at third loop order. To achieve our results, we perform a collinear expansion of three-loop scattering amplitudes using a new expansion-by-subgraph technology, which is based on the method of regions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and Comparison of Control Units for Piezo Actuators to be used for Lorentz Force Compensation inth ILC

Superconducting accelerators, such as the International Linear Collider (ILC), rely on very high Q accelerating cavities to achieve high electric fields at low RF power. Such cavities have very narrow resonances: a few kHz with a 1.3GHz resonance frequency for the ILC. Several mechanical factors cause tune shifts much larger than this: pressure variations in the liquid helium bath; microphonics from pumps and other mechanical devices; and for a pulsed machine such as the ILC, Lorentz force detuning (pressure from the contained RF field). Simple passive stiffening is limited by many manufacturing and material considerations. Therefore, active tuning using piezo actuators is needed. Here we study a supply for their operation. Since commercial power amplifiers are expensive, we analyzed the characteristics of four power amplifiers: (iPZD) built by Istituto Nazionale di Fisica Nucleare (Sezione di Pisa); and a DC-DC converter power supply built in Fermilab (Piezo Master); and two commercial amplifiers, Piezosystem jena and Piezomechanik. This paper presents an analysis and characterization of these amplifiers to understand the cost benefit and reliability when using in a large scale, pulsed beam accelerator like the ILC.

43 PARTICLE ACCELERATORS↗

Beam dynamics and wakefield simulations of the double grating accelerating structure

Laser-driven acceleration in dielectric structures can provide gradients on the order of GeV/m. The small transverse dimension and tiny feature sizes introduce challenges in design, fabrication, and simulation studies of these structures. In this paper we present the results of beam dynamic simulation and short range longitudinal wakefield simulation of the double grating structure. We show the linear trend of acceleration in a dielectric accelerator design and calculate the maximum achievable gradient equal to 0.47E{sub 0} where E0 is maximum electric field of the laser excitation. On the other hand, using wakefield simulations, we show that the loss factor of the structure with 400nm gap size will be 0.12GV/m for a 10fC, 100as electron bunch which is an order of magnitude less than expected gradient near damage threshold of the device.

43 PARTICLE ACCELERATORS↗

Evaluating mesoscale model predictions of diurnal speedup events in the Altamont Pass Wind Resource Area of California

Mesoscale model predictions of wind, turbulence, and wind energy capacity factors are evaluated in the Altamont Pass Wind Resource Area of California (APWRA), where the diurnal regional sea breeze and associated terrain-driven speedup flows drive wind energy production during the summer months. Results from the Weather Research and Forecasting model version 4.4 using a novel three-dimensional planetary boundary layer (3D PBL) scheme, which treats both vertical and horizontal turbulent mixing, are compared to those using a well-established one-dimensional (1D) scheme that treats only vertical turbulent mixing. Each configuration is evaluated over a nearly 3-month-long period during the Hill Flow Study, and due to the recurring nature of the observed speedup flows, diurnal composite averaging is used to capture robust trends in model performance. Both model configurations showed similar overall skill. The general timing and direction of the speedup flows is captured, but their magnitude is overestimated within a typical wind turbine rotor layer. Both also fail to capture a persistent observed near-surface jet-like flow, likely due to the limited grid resolution that is typical of mesoscale models. However, the 3D PBL configuration shows several minor improvements over the 1D PBL configuration, including improved wind speed and turbulence kinetic energy profiles during the accelerating phase of the speedup events, as well as reduced positive wind speed bias at surface stations across the APWRA region. Using a mesoscale wind farm parameterization, modeled capacity factors are also compared to monthly data reported to the US Energy Information Administration (EIA) during the study period. Although the monthly trend in the data is captured, both model configurations overestimate capacity factors by roughly 7 %–11 %. Through model evaluation, this study provides confidence in the 3D PBL scheme for wind energy applications in complex terrain and provides guidance for future testing.

17 WIND ENERGY↗

Parametric Study for use of Stainless Steel as a Material for Thermal Shield in PIP2IT Transferline at Fermilab

Transferline thermal shields are cooled by dedicated cooling lines welded/brazed to the shield at a single point along the circumference. Copper/Aluminium is widely used to fabricate thermal shields because of their higher thermal diffusivity. This causes uniformity of temperature along the surface of the shield thus reducing thermal stresses within allowable values. However, factors such as raw material price, the cost of fabrication depending on standard sizes of pipes/tubes, often drives up the final price of thermal shields. To reduce the cost by making use of easily available stock of standard pipe/tube, it is decided to use stainless steel as a material for thermal shields in the PIP2IT transferline. The present paper discusses the design approach, various factors affecting the conservative selection of thermal shield design.

43 PARTICLE ACCELERATORS↗

The Design of the Parallel Box Cavity with New Radial RF Coupler Design

The design of a E/H parallel cavity has been described. It has been designed with the RF simulation program HFSS. HFSS has been very successfully been used to design and fabricate the Orthogonal E/H box cavity. The main reason for this design choice is to move the RF coupling aperture to surface of minimum electric field gradient. It is suspected that this change will remove the damaged observed in the coupling area experimentally observed in the LBL Pillbox cavity. Another reason for this change is that it corresponds to the location of the coupling aperture in a future real experimental cooling channel. Also, with this design the coupling factor to the cavity can be made adjustable externally, a very useful feature.

43 PARTICLE ACCELERATORS↗

Impedance optimization for EIC

This report provides a summary of the longitudinal impedance optimization performed to date for the following vacuum components: pump slots, transition from the octagonal shape of the arc chambers to the circular shape of the straight section chambers and the main detector chamber. The cut off frequency for E 01 –mode has been estimated for different cross sections of the vacuum chambers. The advantages of using bunch lengthening to decrease the loss factor and reduce the heating effects for the vacuum components is also examined.

43 PARTICLE ACCELERATORS↗

Studies of Resistive Wall Heating at JLAB FEL

When the JLAB FEL is under CW operation, it had been observed that temperature rises over the wiggler vacuum chamber, presumably as the result of the power deposition on the resistive wall of the wiggler chamber. Previous analyses have been done on the resistive wall impedance for various cases, such as DC, AC, and anomalous skin effects*. Here we report an investigation on the beam kinetic energy losses for each of these cases. This study includes the non-ultrarelativistic effect on resistive wall loss, for both round pipe and parallel plates. We will present the comparison of our results with the measured data obtained during CW operation of the JLAB FEL. Other possible factors contributing to the measured heating will also be discussed.

43 PARTICLE ACCELERATORS↗

Recent work on an RF ion thruster

Preliminary results of an RF ion thruster using an immersed coupler in an argon discharge are presented. Conventional ion accelerator optics are used to extract an ion beam. An account is given of the operation of an unoptimized thruster over a range of input powers, propellant flow rates, frequencies, and magnetic field strengths. It is noted that lifetime and overall efficiency factors have not yet been extensively investigated. The results obtained establish the feasibility of this approach and the potential for future improvements. The conical coil employed to couple RF power into the discharge is placed inside the discharge vessel. The discharge is self-sustained by 100-150 MHz RF power at low environmental pressures (approximately 0.00001 torr). The ion extraction is accomplished by conventional accelerator grid optics from an unoptimized 8 cm diameter ion thruster.

Lee, R. Q.↗

Interpreting Space-Mission LET Requirements for SEGR in Power MOSFETs

Single-event gate rupture (SEGR) is a potentially catastrophic failure mechanism of power MOSFETs biased in the off-state. In part due to the severity of-SEGR consequences and in part due to the difficulty of accurated SEGR rate estimation, SEGR mitigation me1hodologies emphasize risk avoidance, using heavy-ion accelerator testing to define safe operating conditions for a surface-incident linear energy transfer {LET). This "safe-operating area" (SOA) within which the device may be biased without experiencing SEGR is then often derated by a prescribed factor to ensure low risk of SEGR. Although research in 1996 indicated that such LET-based SEGR hardness requiremen1s could provide false assurance of safe operation unless one also considered· ion energy], most mission SEGR requirements are still specified in terms of surface-incident LET. Moreover, terrestrial SEGR tests at a given surface-incident LET are limited by the small number of ion species and energies available at heavy-ion accelerators. In comparison, the on-orbit radiation environment is composed of all of the naturally-occurring elements with peak fluxes at nearly GeV/nucleon energies. The primary objective of this study is to examine whether typical derating of high-energy heavy-ion accelerator test data bounds the risk for SEGR from higher-energy on-orbit ions with the mission LET requirement.

Lauenstein, Jean-Marie↗

Benefits and Challenges of the Use of High-Z Plasma Facing Materials in Fusion Devices

The use of high-Z plasma facing components requires intensive research in all areas, i.e. in plasma wall-interaction, in the physics of the confined plasma, diagnostic, and in material development. Only a few present day divertor tokamaks - mainly Alcator C-Mod and ASDEX Upgrade - gained experience with the refractory metals molybdenum and tungsten, respectively. ASDEX Upgrade was stepwise converted from graphite to tungsten PFCs and in parallel a reduction of the deuterium retention by almost a factor of ten has been observed due to the strong suppression of D co-deposition with carbon. The deuterium retained in W is in line with laboratory results. In order to diagnose W sources and the W content in the main plasma adequate spectroscopic methods had to be developed. As expected from the sputtering threshold of Mo and W, negligible erosion by the thermal divertor background plasma is found in ASDEX Upgrade and Alcator C-Mod under low temperature divertor conditions. However, erosion by fast particles and intrinsic impurities, which additionally might be accelerated in rectified electrical fields observed during ion cyclotron frequency heating, plays an important role. The Mo and W concentrations in the plasma centre are strongly affected by plasma transport and variations up to a factor of 50 are observed for similar influxes. However, it could be demonstrated that sawteeth and turbulent transport driven by central heating can suppress central accumulation. The inward transport of high-Z ions at the edge can be efficiently reduced by 'flushing' the pedestal region caused by frequent edge instabilities. Since with metal walls the edge radiation by low-Z impurities is reduced, it has to be substituted in a pure high-Z device by artificially injected low-Z impurities in order to keep the power load at an acceptable level. Experiments at ASDEX Upgrade suggest that a regime with benign erosion and favourable confinement can be achieved. Extrapolations to ITER and DEMO are difficult since the physics of plasma transport is not yet completely understood, the particle and energy fluxes are orders of magnitude higher and the technical boundary conditions in DEMO strongly differ from those of present day devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CCDM model from quantum particle creation: constraints on dark matter mass

In this work the results from the quantum process of matter creation have been used in order to constrain the mass of the dark matter particles in an accelerated Cold Dark Matter model (Creation Cold Dark Matter, CCDM). In order to take into account a back reaction effect due to the particle creation phenomenon, it has been assumed a small deviation ε for the scale factor in the matter dominated era of the form t{sup 2/3+ε}. Based on recent H(z) data, the best fit values for the mass of dark matter created particles and the ε parameter have been found as m = 1.6× 10{sup 3} GeV, restricted to a 68.3% c.l. interval of 1.5 < m < 6.3× 10{sup 7}) GeV and ε = -0.250{sup +0.15}{sub -0.096} at 68.3% c.l. For these best fit values the model correctly recovers a transition from decelerated to accelerated expansion and admits a positive creation rate near the present era. Contrary to recent works in CCDM models where the creation rate was phenomenologically derived, here we have used a quantum mechanical result for the creation rate of real massive scalar particles, given a self consistent justification for the physical process. This method also indicates a possible solution to the so called ''dark degeneracy'', where one can not distinguish if it is the quantum vacuum contribution or quantum particle creation which accelerates the Universe expansion.

79 ASTRONOMY AND ASTROPHYSICS↗

Proposal for a proton-bunch compression experiment at IOTA in the strong space-charge regime

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton-based muon source for a muon collider. This paper discusses a proton-bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring that can circulate a 2.5-MeV proton beam with varying beam parameters and lattice configurations. The study will aim to demonstrate a bunch-compression factor of at least 2 in the IOTA ring while examining the impact of intense space-charge effects on the compression process.

43 PARTICLE ACCELERATORS↗

Nonstoichiometric complex of gramicidin D with KI at 0.80 [angstrom] resolution

The crystal structure of a nonstoichiometric complex of gramicidin D (gD) with KI has been determined at 100 K using synchrotron radiation. The final R factor was 0.106 for 83 988 observed reflections (Friedel pairs were not merged) collected to 0.80 {angstrom}. The structure consists of four independent pentadecapeptides and numerous solvent molecules and salt ions. The general architecture of the antiparallel double-stranded gramicidin dimers in the crystal (a right-handed antiparallel DS{beta}H{sub R} form) closely resembles that of previously published cation complexes of gD. However, a significantly different mixture of gramicidin isomers is found in the crystal of the KI complex, including partial occupancy of phenylalanine at position 11. Only three sites in each of the two crystallographically independent channels are partially occupied by potassium cations instead of the commonly observed seven sites. The sum of the partial occupancies of K{sup +} (1.10 per two dimers) is consistent with the sum of the iodide occupancies (1.095 over eight sites), which is also confirmed by the anomalous signal of the iodide. There was a significant asymmetry of the distribution and occupancies of cations in the crystallographically independent gramicidin channels, in contrast to the distribution found in the rubidium chloride complex with gD.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-D-213-02: Characterization of the Effect of a New Commercial Transmission Detector On Radiotherapy Beams

Purpose: To evaluate the influence of a new commercial transmission detector on radiotherapy beams of various energies. Methods: A transmission detector designed for online treatment monitoring was characterized on a TrueBeam STx linear accelerator with 6MV, 6FFF, 10MV, and 10FFF beams. Measurements of beam characteristics including percentage depth doses (PDDs), inplane and crossplane off-axis profiles at different depths, transmission factors, and skin dose were acquired at field sizes of 3×3cm, 5×5m, 10×10cm, and 20×20cm at 100cm and 80cm source-to-surface distance (SSD). All measurements were taken with and without the transmission detector in the path of the beam. A CC04 chamber was used for all profile and transmission factor measurements. Skin dose was assessed at 100cm, 90cm, and 80cm SSD and using a variety of detectors (Roos and Markus parallel-plate chambers, and OSLD). Results: The PDDs showed small differences between the unperturbed and perturbed beams for both 100cm and 80cm SSD (≤4mm dmax difference and <1.2% average profile difference). The differences were larger for the flattened beams and at larger field sizes. The off-axis profiles showed similar trends. The penumbras looked similar with and without the transmission detector. Comparisons in the central 80% of the profile showed a maximum average (maximum) profile difference between all field sizes of 0.756% (1.535%) and 0.739% (3.682%) for 100cm and 80cm SSD, respectively. The average measured skin dose at 100cm (80cm) SSD for 10×10cm field size was <4% (<35%) dose increase for all energies. For 20×20cm field size, this value increased to <10% (≤45%). Conclusion: The transmission detector has minimal effect on the clinically relevant radiotherapy beams for IMRT and VMAT (field sizes 10×10cm and less). For larger field sizes, some perturbations are observable which would need to be assessed for clinical impact. The authors of this publication has research support from IBA Dosimetry.

60 APPLIED LIFE SCIENCES↗

The Acceleration of Energetic Particles at Coronal Shocks and Emergence of a Double Power-law Feature in Particle Energy Spectra

We present numerical modeling of particle acceleration at coronal shocks propagating through a streamer-like magnetic field by solving the Parker transport equation with spatial diffusion both along and across the magnetic field. We show that the location on the shock where the high-energy particle intensity is the largest, depends on the energy of the particles and on time. The acceleration of particles to more than 100 MeV mainly occurs in the shock-streamer interaction region, due to perpendicular shock geometry and the trapping effect of closed magnetic fields. A comparison of the particle spectra to that in a radial magnetic field shows that the intensity at 100 MeV (200 MeV) is enhanced by more than one order (two orders) of magnitude. This indicates that the streamer-like magnetic field can be an important factor in producing large solar energetic particle events. We also show that the energy spectrum integrated over the simulation domain consists of two different power laws. Further analysis suggests that it may be a mixture of two distinct populations accelerated in the streamer and open field regions, where the acceleration rate differs substantially. Our calculations also show that the particle spectra are affected considerably by a number of parameters, such as the streamer tilt angle, particle spatial diffusion coefficient, and shock compression ratio. While the low-energy spectra agree well with standard diffusive shock acceleration theory, the break energy ranges from ~1 MeV to ~90 MeV and the high-energy spectra can extend to ~1 GeV with a slope of ~2–3.

97 MATHEMATICS AND COMPUTING↗

Refine your search to explore more results.