Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Numerical Simulation and Modeling of Hydrogen Gas Evolution on Planar and Microwire Array Electrodes

The impact of gas evolution on the electrochemical characteristics of planar electrodes and microwire array electrodes has been analyzed using modeling and simulation. The impacts can mainly be broken into three phenomena: a) a shift in the local reversible hydrogen electrode potential; b) hyperpolarization; and c) an increase in the solution resistance of the electrolyte. The local reversible hydrogen electrode potential shift was found to play the most important role, constituting >40% of the total potential drop between the cathode and reference electrode, following correction for cell resistance. Compared to planar electrodes, a microwire array structure reduces the impact of bubbles on the solution conductance, but the shift in the local reversible hydrogen electrode potential varies with distance from the actual electrode surface.

25 ENERGY STORAGE↗

Si/TiO 2 Tandem-Junction Microwire Arrays for Unassisted Solar-Driven Water Splitting

In this work, tandem-junction microwire array photoelectrodes have been fabricated by coating np + -Si radial homojunction microwire arrays sequentially with fluorine-doped tin oxide (FTO) and titanium dioxide (TiO 2 ). These photoelectrodes effected unassisted water splitting under simulated 1 Sun conditions with an open-circuit potential ($E_{\text{oc}}$) of –1.5 V vs the formal potential for oxygen evolution, $E^0$'(OH – /O 2 ), a current density at $E = E^0$'(OH – /O 2 ) of 0.78 mA cm –2 , a fill factor ($\textit{ff}$) = 0.51, and a photovoltaic-biased photoelectrochemical ideal regenerative cell efficiency of 0.6%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Machine Learning Algorithms for Natural Gas Identification with Mixed Potential Electrochemical Sensor Arrays

Mixed-potential electrochemical sensor arrays consisting of indium tin oxide (ITO), La 0.87 Sr 0.13 CrO 3 , Au, and Pt electrodes can detect the leaks from natural gas infrastructure. Algorithms are needed to correctly identify natural gas sources from background natural and anthropogenic sources such as wetlands or agriculture. We report for the first time a comparison of several machine learning methods for mixture identification in the context of natural gas emissions monitoring by mixed potential sensor arrays. Random Forest, Artificial Neural Network, and Nearest Neighbor methods successfully classified air mixtures containing only CH 4 , two types of natural gas simulants, and CH 4 +NH 3 with >98% identification accuracy. The model complexity of these methods were optimized and the degree of robustness against overfitting was determined. Finally, these methods are benchmarked on both desktop PC and single-board computer hardware to simulate their application in a portable internet-of-things sensor package. The combined results show that the random forest method is the preferred method for mixture identification with its high accuracy (>98%), robustness against overfitting with increasing model complexity, and had less than 10 ms training time and less than 0.1 ms inference time on single-board computer hardware.

03 NATURAL GAS↗

Compact and multi-view solid state neutral particle analyzer arrays on National Spherical Torus Experiment-Upgrade

A compact and multi-view Solid State Neutral Particle Analyzer (SSNPA) diagnostic based on silicon photodiode arrays has been successfully tested on the National Spherical Torus Experiment-Upgrade (NSTX-U). The SSNPA diagnostic provides spatially, temporally, and pitch-angle resolved measurements of fast-ion distribution by detecting fast neutral flux resulting from charge exchange (CX) reactions. The system consists of three 16-channel subsystems: t-SSNPA viewing the plasma mid-radius and neutral beam (NB) line #2 tangentially, r-SSNPA viewing the plasma core and NB line #1 radially and p-SSNPA with no intersection with any NB lines. Due to the setup geometry, the active CX signals of t-SSNPA and r-SSNPA are mainly sensitive to passing and trapped particles respectively. In addition, both t-SSNPA and r-SSNPA utilize three vertically stacked arrays with different filter thickness to obtain coarse energy information. The experimental data show that all channels are operational. The signal to noise ratio is typically larger than 10 and the main noise is x-ray induced signal. The active and passive CX signals are clearly observed on t-SSNPA and r-SSNPA during NB modulation. The SSNPA data also indicate significant losses of passing particles during sawteeth, while trapped particles are weakly affected. Fluctuations up to 120 kHz, have been observed on SSNPA, and they are strongly correlated with magnetohydrodynamics (MHD) instabilities.

Charge exchange neutral particle fast ion distribu↗

Geometric concepts for stellarator permanent magnet arrays

The development of stellarators that use permanent magnet arrays to shape their confining magnetic fields has been a topic of recent interest, but the requirements for how such magnets must be shaped, manufactured, and assembled remain to be determined. To address these open questions, we have performed a study of geometric concepts for magnet arrays with the aid of the newly developed MAGPIE code. A proposed experiment similar to the National Compact Stellarator Experiment (NCSX) is used as a test case. Two classes of magnet geometry are explored: curved bricks that conform to a regular grid in cylindrical coordinates, and hexahedra that conform to the toroidal plasma geometry. In addition, we test constraints on the magnet polarization. While magnet configurations constrained to be polarized normally to a toroidal surface around the plasma are unable to meet the required magnetic field parameters when subject to physical limitations on the strength of present-day magnets, configurations with unconstrained polarizations are shown to satisfy the physics requirements for a targeted plasma.

stellarator, permanent magnet, optimization↗

Kokkos Array

The Kokkos Array library implements shared-memory array data structures and parallel task dispatch interfaces for data-parallel computational kernels that are performance-portable to multicore-CPU and manycore-accelerator (e.g., GPGPU) devices.

Edwards Daniel Sunderland, HaroldCarter↗

CasCollect: Detecting cas genes and CRISPR arrays in raw sequence data v1

This software examines raw Illumina sequence data files for cas genes and CRISPR arrays, either to be used as evidence of genome editing or for basic analysis of bacterial genomes. It translates sequencing reads into peptide sequences, and runs these against sensitive hidden Markov models for numerous Cas protein families. The set of hit read seeds is then expanded leftward and rightward by sequence matching to remaining reads, and after multiple cycles, this small fraction of the original reads is assembled to produce Cas operons. A separate mode using known CRISPR repeat sequences for a genus are used to identify CRISPR arrays that may be in genomic locations that are isolated from Cas genes.SAND2019-11770 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Williams, Kelly↗

Temporal light modulation: A phantom array visibility measure

At temporal light modulation (TLM) frequencies between 80 Hz and 20 000 Hz observers may perceive a series of repeated images called the phantom array effect (PAE) when they move their eyes in large saccades across a modulating light source or across a scene lit by the modulating light source. To date, there is no well-established measure for quantifying PAE visibility, but there is growing awareness of the need for one among design professionals and sensitive populations. This paper documents a new measure, the phantom array visibility measure (PAVM), which is based on the results of recent human factors experiments. The measure follows the mathematical underpinning used by the flicker visibility measure and the stroboscopic visibility measure, where the time-domain TLM waveform is converted into its Fourier frequency components; each component is evaluated through a threshold curve of modulation depth, then summed through an equation employing a Minkowski exponent. This scales the PAVM so that a value of 1 indicates a waveform at a threshold visibility in the conditions of the underlying experiment.

Tan, J.↗

STILGAR Seismic Array Data

Two three-component dense seismic arrays were deployed above an active limestone mine in Pleasant Gap, Pennsylvania; one in the fall and one in the spring of 2023. Each campaign lasted approximately four weeks and included 80 to 100 seismic stations with stations spaced between 100 and 400 meters apart. Each campaign also included several small dense seismic arrays. Two types of seismic stations were deployed including FairfieldNodal ZLand 3C All-in-One seismometers and Geospace 3C GS-ONE geophone paired with GSX3 and GSX4 dataloggers. This dataset includes ~ 4 TB of three-component continuously recorded seismic data in the miniseed format data from both campaigns as well as a readme file for the data structure.

58 GEOSCIENCES↗

Terahertz spectroscopy with a holographic Fourier transform spectrometer plus array detector using coherent synchrotron radiation

By use of coherent terahertz synchrotron radiation, we experimentally tested a holographic Fourier transform spectrometer coupled to an array detector to determine its viability as a spectral device. Somewhat surprisingly, the overall performance strongly depends on the absorptivity of the birefringent lithium tantalate pixels in the array detector.

43 PARTICLE ACCELERATORS↗

Temperature and nonlinearity corrections for a photodiode array spectrometer used in the field

Temperature and nonlinearity effects are two important factors that limit the use of photodiode array spectrometers. Usually the spectrometer is calibrated at a known temperature against a reference source of a particular spectral radiance, and then it is used at different temperatures to measure sources of different spectral radiances. These factors are expected to be problematic for nontemperature-stabilized instruments used for in-the-field experiments, where the radiant power of the site changes continuously with the sun tilt. This paper describes the effect of ambient temperature on a nontemperature-stabilized linear photodiode array spectrometer over the temperature range from 5 deg. C to 40 deg. C. The nonlinearity effects on both signal amplification and different levels of radiant power have also been studied and are presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Far infrared thermal detectors for laser radiometry using a carbon nanotube array

We present a description of a 1.5 mm long, vertically aligned carbon nanotube array (VANTA) on a thermopile and separately on a pyroelectric detector. Three VANTA samples, having average lengths of 40 {mu}m, 150 {mu}m, and 1.5 mm were evaluated with respect to reflectance at a laser wavelength of 394 {mu}m(760 GHz), and we found that the reflectance decreases substantially with increasing tube length, ranging from 0.38 to 0.23 to 0.01, respectively. The responsivity of the thermopile by electrical heating (98.4 mA/W) was equal to that by optical heating (98.0 mA/W) within the uncertainty of the measurement. We analyzed the frequency response and temporal response and found a thermal decay period of 500 ms, which is consistent with the specific heat of comparable VANTAs in the literature. The extremely low (0.01) reflectance of the 1.5 mm VANTAs and the fact that the array is readily transferable to the detector's surface is, to our knowledge, unprecedented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fourier-method beam analysis for coherent vertical cavity surface emitting laser arrays

Effective engineering and exploitation of coherently coupled vertical cavity surface emitting laser arrays will benefit from simple and fast characterization of the optical coupling and coherence. We propose a Fourier method of analyzing beam profiles as an alternative to the prior beam visibility analysis and show that the mode suppression ratio and phase between a pair of supermodes can be extracted. Our analysis enables fast quantitative determination of the array coherence and supermode characteristics.

Strzebonski, Pawel (ORCID:0000000156286296)↗

Altering apparent optical properties with an array of semitransparent mesoscale structures

The ability to control and optimize interactions between light and matter has much utility in engineering design. A well-researched way to achieve optical property modulation is via the use of optical metamaterials, which feature sub-wavelength scale surface structures. In this work, an alternative approach for modulating optical properties is presented using a composite surface modified with a periodic array of semitransparent hemispherical shell mesoscale structures which are larger than the incident light wavelength. A ray-tracing simulation approach is used to predict the optical behavior for an arrayed surface. At oblique angles of incidence, significant increases and decreases in apparent absorptance are achieved via the use of optically thick and thin shells, respectively. Additionally, a potential application to solar cells is described with optimal spectral behavior achieved via the use of semitransparent external structures.

Kucuktas, Onur A.↗

Coherent Beam Combining of High Power Broad-Area Laser Diode Array with a Closed-V-shape External Talbot Cavity

We have coherently combined a high-power broad-area laser diode array by using a feedback loop closed off-axis external Talbot cavity. The off-axis feedback from two gratings provides transverse-mode control of broad-area lasers. The Talbot configuration of the external cavity implements diffractive coupling among laser diodes. Feedback from two gratings increases external cavity quality factor and spectrum selection capability. As a result, spatial coherence was improved and spectral linewidth was narrowed down. The high visibility of the far-field profile indicates that high spatial coherence was achieved. We also observed symmetric far-field profiles indicating that laser array was phase locked to in-phase and out-of-phase super-modes, respectively. Transition between these super-modes was observed by tuning one grating's tilted angle.

42 ENGINEERING↗

Interplay between gain and loss in arrays of nonlinear plasmonic nanoparticles: toward parametric downconversion and amplification

With the help of a theoretical model and finite-difference time-domain (FDTD) simulations based on the hydrodynamic–Maxwell model, we examine the effect of difference-frequency generation (DFG) in an array of L-shaped metal nanoparticles (MNPs) characterized by intrinsic plasmonic nonlinearity. The outcomes of the calculations reveal the spectral interplay between gain and loss in the vicinity of the fundamental frequency of the localized surface plasmon resonances. Subsequently, we identify different array thicknesses and pumping regimes facilitating parametric amplification and spontaneous parametric downconversion. Our results suggest that the parametric amplification regime becomes feasible on a scale of hundreds of nanometers and spontaneous parametric downconversion on the scale of tens of nanometers, opening up new exciting opportunities for developing building blocks of photonic metasurfaces.

Shah, Syed A.↗

Data Arrays for Microearthquake (MEQ) Monitoring using Deep Learning for the Newberry EGS Sites

The 'Machine Learning Approaches to Predicting Induced Seismicity and Imaging Geothermal Reservoir Properties' project looks to apply machine learning (ML) methods to Microearthquake (MEQ) data for imaging geothermal reservoir properties and forecasting seismic events, in order to advance geothermal exploration and safe geothermal energy production. As part of the project, this submission provides data arrays for 149 microearthquakes between the year 2012 and 2013 at the Newberry EGS Site for use with the Deep Learning Algorithm that has been developed. The data provided includes raw waveform data, location data, normalized waveform data, and processed waveform data. Penn State Geothermal Team has shared the following files from the project: - 149 microearthquakes (MEQs) between 2012 and 2013 at Newberry EGS sites, 'Normalized Waveform Inputs.npz' are normalized waveforms. - labels of 149 MEQs: Processed Waveform Inputs.npz - location labels of 149 MEQs: Location Data.npz Note: .npz is the python file format by NumPy that provides storage of array data.

15 GEOTHERMAL ENERGY↗

Refine your search to explore more results.