Search NASA⌕ Search

SEARCH · Search NASA

Results for “delay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

{beta}-Delayed Deuteron Emission from {sup 11}Li: Decay of the Halo

The deuteron-emission channel in the {beta} decay of the halo nucleus {sup 11}Li was measured at the Isotope Separator and Accelerator facility at TRIUMF by implanting postaccelerated {sup 11}Li ions into a segmented silicon detector. The events of interest were identified by correlating the decays of {sup 11}Li with those of the daughter nuclei. This method allowed the energy spectrum of the emitted deuterons to be extracted, free from contributions from other channels, and a precise value for the branching ratio B{sub d}=1.30(13)x10{sup -4} to be deduced for E{sub c.m.}>200 keV. The results provide the first unambiguous experimental evidence that the decay takes place essentially in the halo of {sup 11}Li and that it proceeds mainly to the {sup 9}Li+d continuum, opening up a new means to study the halo wave function of {sup 11}Li.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of a Delay Attack in the Secondary Control of Grid-Tied Inverter Systems

This work is developed for the identification of a denial-of-service cyberattack on the secondary controller of inverter systems which is connected to the power grid. The identification is made through the dynamic response of the reactive power (Q) of the system under attack. By observing the dynamic characteristic of Q, it is possible to correlate the attack with the nominal response of the hierarchical controller. The article shows that the occurrence of the attack can be identified through a supervisory control that runs a model in parallel. The article argues that after an early identification of the attack, a local controller can take action to mitigate its effects on the system’s response.

Roig Greidanus, Mateo D.↗

A New Model of Frequency Delay in Power Systems

Observations of slow frequency signals in power systems have been explained by continuum wave equations that approximate the system's electromechanical dynamics. These continuum models predict that the signal speed is a function of the rotational inertia of the generators and impedances of the transmission lines. Here, we show that frequency signals with speeds modulated by these factors are predicted by the swing and Kirchhoff equations, without resorting to a continuum model. Our analysis also shows that the precision of the sensors used to measure frequency has a significant impact on the apparent speed of the frequency signal.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

High-Fuel Loading Ignition Delay Time Characterization of Hydrogen/Natural Gas/Ammonia at Gas Turbine-Relevant Conditions Inside a High-Pressure Shock Tube

Abstract This study explores the combustion characterization of high-fuel percentage, air-diluted mixtures of H2 mixed with natural gas (NG) as well as mixtures of H2 and NH3 at temperatures and pressures relevant to turbine operating conditions (20–30 bar, 1000–1500 K). Lower temperatures (below 1070 K) exhibit preignition characteristics due to non-homogeneity. An attempt to mitigate these occurrences at high pressures is investigated using the constrained reaction volume (CRV) stage-filling technique. Due to the need to further refine the facility CRV stage-filling uncertainty, only higher temperature data will be interpreted at this time. The test conditions in this study closely replicate the temperatures, pressures, and mixtures that would be seen in hydrogen-powered gas turbines, making it the first to explore such conditions. The experimental IDTs were compared against the current state-of-the-art chemical kinetic models for mechanism validation. The current work will advance H2-powered turbines and aims to determine the optimum molecular ratio of H2 when mixed with natural gas.

Pierro, Michael↗

Refine your search to explore more results.