Search NASA⌕ Search

SEARCH · Search NASA

Results for “device simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

The Flostation - an Immersive Cyberspace System

A flostation is a computer-controlled apparatus that, along with one or more computer(s) and other computer-controlled equipment, is part of an immersive cyberspace system. The system is said to be immersive in two senses of the word: (1) It supports the body in a modified form neutral posture experienced in zero gravity and (2) it is equipped with computer-controlled display equipment that helps to give the occupant of the chair a feeling of immersion in an environment that the system is designed to simulate. Neutral immersion was conceived during the Gemini program as a means of training astronauts for working in a zerogravity environment. Current derivatives include neutral-buoyancy tanks and the KC-135 airplane, each of which mimics the effects of zero gravity. While these have performed well in simulating the shorter-duration flights typical of the space program to date, a training device that can take astronauts to the next level will be needed for simulating longer-duration flights such as that of the International Space Station. The flostation is expected to satisfy this need. The flostation could also be adapted and replicated for use in commercial ventures ranging from home entertainment to medical treatment. The use of neutral immersion in the flostation enables the occupant to recline in an optimal posture of rest and meditation. This posture, combines savasana (known to practitioners of yoga) and a modified form of the neutral posture assumed by astronauts in outer space. As the occupant relaxes, awareness of the physical body is reduced. The neutral body posture, which can be maintained for hours without discomfort, is extended to the eyes, ears, and hands. The occupant can be surrounded with a full-field-of-view visual display and nearphone sound, and can be stimulated with full-body vibration and motion cueing. Once fully immersed, the occupant can use neutral hand controllers (that is, hand-posture sensors) to control various aspects of the simulated environment.

Park, Brian↗

Quantum Simulation of Molecular Electronic States with a Transcorrelated Hamiltonian: Higher Accuracy with Fewer Qubits

Simulation of electronic structure is one of the most promising applications on noisy intermediate-scale quantum (NISQ) era devices. However, NISQ devices suffer from a number of challenges like limited qubit connectivity, short coherence times, and sizable gate error rates. Thus, desired quantum algorithms should require shallow circuit depths and low qubit counts to take advantage of these devices. Here, we attempt to reduce quantum resource requirements for molecular simulations on a quantum computer while maintaining the desired accuracy with the help of classical quantum chemical theories of canonical transformation and explicit correlation. In this work, compact ab initio Hamiltonians are generated classically, in the second quantized form, through an approximate similarity transformation of the Hamiltonian with (a) an explicitly correlated two-body unitary operator with generalized pair excitations that remove the Coulombic electron–electron singularities from the Hamiltonian and (b) a unitary one-body operator to efficiently capture the orbital relaxation effects required for accurate description of the excited states. The resulting transcorrelated Hamiltonians are able to describe both the ground and the excited states of molecular systems in a balanced manner. Using the variational quantum eigensolver (VQE) method based on the unitary coupled cluster with singles and doubles (UCCSD) ansatz and only a minimal basis set (ANO-RCC-MB), we demonstrate that the transcorrelated Hamiltonians can produce ground state energies comparable to the reference CCSD energies with the much larger cc-pVTZ basis set. This leads to a reduction in the number of required CNOT gates by more than 3 orders of magnitude for the chemical species studied in this work. Furthermore, using the quantum equation of motion (qEOM) formalism in conjunction with the transcorrelated Hamiltonian, we are able to reduce the deviations in the excitation energies from the reference EOM-CCSD/cc-pVTZ values by an order of magnitude. In conclusion, the transcorrelated Hamiltonians developed here are Hermitian and contain only one- and two-body interaction terms and thus can be easily combined with any quantum algorithm for accurate electronic structure simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance analysis of boron nitride embedded armchair graphene nanoribbon metal–oxide–semiconductor field effect transistor with Stone Wales defects

We study the performance of a hybrid Graphene-Boron Nitride armchair nanoribbon (a-GNR-BN) n-MOSFET at its ballistic transport limit. We consider three geometric configurations 3p, 3p + 1, and 3p + 2 of a-GNR-BN with BN atoms embedded on either side (2, 4, and 6 BN) on the GNR. Material properties like band gap, effective mass, and density of states of these H-passivated structures are evaluated using the Density Functional Theory. Using these material parameters, self-consistent Poisson-Schrodinger simulations are carried out under the Non Equilibrium Green's Function formalism to calculate the ballistic n-MOSFET device characteristics. For a hybrid nanoribbon of width ∼5 nm, the simulated ON current is found to be in the range of 265 μA–280 μA with an ON/OFF ratio 7.1 × 10{sup 6}–7.4 × 10{sup 6} for a V{sub DD} = 0.68 V corresponding to 10 nm technology node. We further study the impact of randomly distributed Stone Wales (SW) defects in these hybrid structures and only 2.5% degradation of ON current is observed for SW defect density of 3.18%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrating micromagnets and hybrid nanowires for topological quantum computing

Majorana zero modes are expected to arise in semiconductor-superconductor hybrid systems, with potential topological quantum computing applications. One limitation of this approach is the need for a relatively high external magnetic field that should also change direction at the nanoscale. This proposal considers devices that incorporate micromagnets to address this challenge. We perform numerical simulations of stray magnetic fields from different micromagnet configurations, which are then used to solve for Majorana wavefunctions. Several devices are proposed, starting with the basic four-magnet design to align magnetic field with the nanowire and scaling up to nanowire T-junctions. The feasibility of the approach is assessed by performing magnetic imaging of prototype patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Speed Single-Event Current Transient Measurements in SiGe HBTs

Time-resolved ion beam induced charge reveals heavy ion response of IBM 5AM SiGe HBT: 1) Position correlation. 2) Unique response for different bias schemes. 3) Similarities to TPA pulsed-laser data. Heavy ion broad-beam transients provide more realistic device response: 1) Feedback using microbeam data 2) Overcome existing issues of LET and ion range with microbeam Both micro- and broad-beam data sets yield valuable input for TCAD simulations. Uncover detailed mechanisms for SiGe HBTs and other devices fabricated on lightly-doped substrates.

Pellish, Jonathan A.↗

Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. Conclusions: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.

60 APPLIED LIFE SCIENCES↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Shape‐Dependent Multi‐Weight Magnetic Artificial Synapses for Neuromorphic Computing

Abstract In neuromorphic computing, artificial synapses provide a multi‐weight (MW) conductance state that is set based on inputs from neurons, analogous to the brain. Herein, artificial synapses based on magnetic materials that use a magnetic tunnel junction (MTJ) and a magnetic domain wall (DW) are explored. By fabricating lithographic notches in a DW track underneath a single MTJ, 3–5 stable resistance states that can be repeatably controlled electrically using spin‐orbit torque are achieved. The effect of geometry on the synapse behavior is explored, showing that a trapezoidal device has asymmetric weight updates with high controllability, while a rectangular device has higher stochasticity, but with stable resistance levels. The device data is input into neuromorphic computing simulators to show the usefulness of application‐specific synaptic functions. Implementing an artificial neural network (NN) applied to streamed Fashion‐MNIST data, the trapezoidal magnetic synapse can be used as a metaplastic function for efficient online learning. Implementing a convolutional NN for CIFAR‐100 image recognition, the rectangular magnetic synapse achieves near‐ideal inference accuracy, due to the stability of its resistance levels. This work shows MW magnetic synapses are a feasible technology for neuromorphic computing and provides design guidelines for emerging artificial synapse technologies.

Leonard, Thomas↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive elasticity policies for staging-based in situ visualization

In situ processing aims to alleviate the growing gap between computation and I/O capabilities by performing data processing close to the data source. In situ processing is widely used to process data generated by multiple data sources, including observation data from edge devices or scientific observational facilities and the simulation data generated by scientific computation on a high-performance computing (HPC) platform. For a scientific workflow that is run on an HPC platform and composed of a simulation program and an in situ data analytics or visualization (abbreviated as ana/vis) task, there is an implicit assumption that the computing resources assigned to the workflow keep static during the workflow execution. However, with the converging trend between the HPC and cloud computing platform, running the in situ ana/vis task in an elastic way is promising to decrease its overhead and improve its resource utilization rate. Resource elasticity represents the ability to change resource configurations such as the number of computing nodes/processes during workflow execution. An elastic job may dynamically adjust resource configurations; it may use a few resources at the beginning and more resources toward the end of the job when interesting data appear. However, it is hard to predict a priori how many computing nodes/processes need to be added/removed during the workflow execution to adapt to changing workflow needs. How to efficiently guide elasticity operations, such as growing or shrinking the number of processes used for in situ analysis during workflow execution, is an open-ended research question. In this article, we present adaptive elasticity policies that adopt workflow runtime information collected during workflow execution to predict how to trigger the addition/removal of processes in order to minimize in situ processing overhead. Taking in situ visualization tasks as an example, we integrate the presented elasticity policies into a staging-based elastic workflow and evaluate its efficiency in multiple elasticity scenarios. Compared with the situation without elasticity or with a static elasticity policy that uses a fixed number of processes for each rescaling operation, the adaptive elasticity policy can save overhead in finding a proper resource configuration and improve resource utilization efficiency. Furthermore, one experiment illustrates that the adaptive elasticity policy saves 41% of core-hours compared with the situation without the resource elasticity.

97 MATHEMATICS AND COMPUTING↗

Postoperative Intensity-Modulated Radiotherapy in Low-Risk Endometrial Cancers: Final Results of a Phase I Study

Purpose: To determine the maximum tolerated dose of short-course radiotherapy (intensity-modulated radiotherapy technique) to the upper two thirds of the vagina in endometrial cancers with low risk of local recurrence. Patients and Methods: A Phase I clinical trial was performed. Eligible patients had low-risk resected primary endometrial adenocarcinomas. Radiotherapy was delivered in 5 fractions over 1 week. The planning target volume was the clinical target volume plus 5 mm. The clinical target volume was defined as the upper two thirds of the vagina as evidenced at CT simulation by a vaginal radio-opaque device. The planning target volume was irradiated by a seven-field intensity-modulated radiotherapy technique, planned by the Plato Sunrise inverse planning system. A first cohort of 6 patients received 25 Gy (5-Gy fractions), and a subsequent cohort received 30 Gy (6-Gy fractions). The Common Toxicity Criteria scale, version 3.0, was used to score toxicity. Results: Twelve patients with endometrial cancer were enrolled. Median age was 58 years (range, 49-74 years). Pathologic stage was IB (83.3%) and IC (16.7%). Median tumor size was 30 mm (range, 15-50 mm). All patients completed the prescribed radiotherapy. No patient experienced a dose-limiting toxicity at the first level, and the radiotherapy dose was escalated from 25 to 30 Gy. No patients at the second dose level experienced dose-limiting toxicity. The most common Grade 2 toxicity was gastrointestinal, which was tolerable and manageable. Conclusions: The maximum tolerated dose of short-course radiotherapy was 30 Gy at 6 Gy per fraction. On the basis of this result, we are conducting a Phase II study with radiotherapy delivered at 30 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fast algorithm for sparse matrix computations related to inversion

We have developed a fast algorithm for computing certain entries of the inverse of a sparse matrix. Such computations are critical to many applications, such as the calculation of non-equilibrium Green’s functions G{sup r} and G{sup <} for nano-devices. The FIND (Fast Inverse using Nested Dissection) algorithm is optimal in the big-O sense. However, in practice, FIND suffers from two problems due to the width-2 separators used by its partitioning scheme. One problem is the presence of a large constant factor in the computational cost of FIND. The other problem is that the partitioning scheme used by FIND is incompatible with most existing partitioning methods and libraries for nested dissection, which all use width-1 separators. Our new algorithm resolves these problems by thoroughly decomposing the computation process such that width-1 separators can be used, resulting in a significant speedup over FIND for realistic devices — up to twelve-fold in simulation. The new algorithm also has the added advantage that desired off-diagonal entries can be computed for free. Consequently, our algorithm is faster than the current state-of-the-art recursive methods for meshes of any size. Furthermore, the framework used in the analysis of our algorithm is the first attempt to explicitly apply the widely-used relationship between mesh nodes and matrix computations to the problem of multiple eliminations with reuse of intermediate results. This framework makes our algorithm easier to generalize, and also easier to compare against other methods related to elimination trees. Finally, our accuracy analysis shows that the algorithms that require back-substitution are subject to significant extra round-off errors, which become extremely large even for some well-conditioned matrices or matrices with only moderately large condition numbers. When compared to these back-substitution algorithms, our algorithm is generally a few orders of magnitude more accurate, and our produced round-off errors stay at a reasonable level.

97 MATHEMATICS AND COMPUTING↗

Optically connected memory for disaggregated data centers

Recent advances in integrated photonics enable the implementation of reconfigurable, high-bandwidth, and low energy-per-bit interconnects in next-generation data centers. We propose and evaluate an Optically Connected Memory (OCM) architecture that disaggregates the main memory from the computation nodes in data centers. OCM is based on micro-ring resonators (MRRs), and it does not require any modification to the DRAM memory modules. We calculate energy consumption from real photonic devices and integrate them into a system simulator to evaluate performance. Here, our results show that (1) OCM is capable of interconnecting four DDR4 memory channels to a computing node using two fibers with 1.02 pJ energy-per-bit consumption and (2) OCM performs up to 5.5× faster than a disaggregated memory with 40G PCIe NIC connectors to computing nodes.

97 MATHEMATICS AND COMPUTING↗

Analysis of dislocation configurations in SiC crystals through X-ray topography aided by ray tracing simulations

Silicon carbide as a wide bandgap semiconductor is of great research interest for its widespread deployment in a range of electronic and optoelectronic devices, particularly in power electronics. However, defects in silicon carbide crystals are still major concerns that is hampering the development of high-performance devices. X-ray topography, particularly using the synchrotron beam has been instrumental in characterizing and analyzing defect configurations in silicon carbide crystals to optimize crystal growth as well as understand the effect of defects on device performance. Here, in recent years, the use of ray-tracing simulation technique based on the orientation contrast mechanism to simulate contrast of defects observed on actual X-ray topographs has proven to be an effective approach to investigate the nature of crystallographic defects in various semiconductors. This review discusses the principle of ray-tracing simulation and its application and modifications to incorporate the effects of surface relaxation and photoelectric absorption to better simulate different dislocations observed in 4H–SiC as well as 6H–SiC crystals of various orientations. The adaptation to weak beam topography and plane wave topography is also discussed. The application of ray-tracing simulation in dislocation characterization of silicon carbide of different polytypes is systematically reviewed including different types of dislocations observed in both off-axis wafers and axial-sliced samples through synchrotron X-ray topography under various beam conditions, recording geometries and reflections. The result of ray-tracing simulation is further utilized in other studies including the investigation of effective penetration depth of all types of dislocations lying on the basal plane on grazing-incidence X-ray topography.

Engineering↗

Density of States Broadening in CH 3 NH 3 PbI 3 Hybrid Perovskites Understood from ab Initio Molecular Dynamics Simulations

Lead-halide perovskites are promising materials in optoelectronic devices for their unique properties including direct band gap, strong light absorption, high carrier mobility, and low fabrication cost. Here, by using ab inito molecular dynamics and electronic structure calculations, we report a systematic study on the broadening density of states (DOS) deep in the valence bands that has been experimentally observed but absent in static calculations. We quantify the broadening DOS reduction from the cubic phase to lower-temperature tetragonal and orthorhombic phases and attribute observed effects to the molecular vibrations and the anharmonicity of iodine atoms motion. Specifically, the MA cations’ vibrations are strongly linked to the moderate C–N stretch and CH 3 bend, as well as the strong CH 3 and NH 3 + stretches. Furthermore, these results present a theoretical perspective on the structural dynamics in lead-halide perovskites which may be valuable for future studies toward desired functionalities in perovskite-based optoelectronic devices.

36 MATERIALS SCIENCE↗

Off-resonant detection of domain wall oscillations using deterministically placed nanodiamonds

Abstract Nitrogen-vacancy (NV) centers in diamond offer a sensitive method of measuring the spatially localized dynamics of magnetization and associated spin textures in ferromagnetic materials. We use NV centers in a deterministically positioned nanodiamond to demonstrate off-resonant detection of microwave field-driven GHz-scale oscillations of a single domain wall (DW). The technique exploits the enhanced relaxation of NV center spins due to the broadband stray field noise generated by an oscillating DW pinned at an engineered defect in a lithographically patterned ferromagnetic nanowire. Discrepancies between the observed DW oscillation frequency and predictions from micromagnetic simulations suggest extreme sensitivity of DW dynamics to patterning imperfections such as edge roughness. These experiments and simulations identify potential pathways toward quantum spintronic devices that exploit current-driven DWs as nanoscale microwave generators for qubit control, greatly increasing the driving field at an NV center and thus drastically reducing the π pulse time.

Rable, Jeffrey↗

Quantum simulation of conical intersections

We explore the simulation of conical intersections (CIs) on quantum devices, setting the groundwork for potential applications in nonadiabatic quantum dynamics within molecular systems.

Chemistry↗

Improved foilless Ku-band transit-time oscillator for generating gigawatt level microwave with low guiding magnetic field

An improved foilless Ku-band transit-time oscillator with low guiding magnetic field is proposed and investigated in this paper. With a non-uniform buncher and a coaxial TM{sub 02} mode dual-resonant reflector, this improved device can output gigawatt level Ku-band microwave with relatively compact radial dimensions. Besides the above virtue, this novel reflector also has the merits of high TEM reflectance, being more suitable for pre-modulating the electron beam and enhancing the conversion efficiency. Moreover, in order to further increase the conversion efficiency and lower the power saturation time, a depth-tunable coaxial collector and a resonant cavity located before the extractor are employed in our device. Main structure parameters of the device are optimized by particle in cell simulations. The typical simulation result is that, with a 380 kV, 8.2 kA beam guided by a magnetic field of about 0.6 T, 1.15 GW microwave pulse at 14.25 GHz is generated, yielding a conversion efficiency of about 37%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refine your search to explore more results.