At least 1,801 records · Page 100

Spectroscopic diagnostics of high-temperature plasma in stellar coronae using Fe XXIV-XXIV K-shell lines with XRISM

The RS CVn type binary star GT Muscae was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV-XXIV K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional ionization equilibrium and Maxwell electron energy distribution with a single temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$\alpha$, Ly$\alpha$, and He$\beta$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with thermal broadening of Fe xxv, and the broad-band fitting results in the 1.7–10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $\kappa$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

X-rays: stars↗

Demonstration of a Novel Radiochemical Mix Diagnostic for Fusion Implosions at the National Ignition Facility

Mixing of the ablator material into the fuel of an inertial confinement fusion implosion reduces compression and enhances radiative losses, preventing ignition. Here, we describe a novel use of charged-particle radiochemistry to measure the ablator mix in contact with the fusion hot spot. The capsule uses a graded Be-Cr layer to increase the confinement of the hot spot. 52 Mn and 51 Cr isotopes are collected from the implosion and counted, and the ratio is related to the amount of Cr mixed into the hot spot. Thus, a new diagnostic to determine the degradation due to mix on fusion implosions has been developed.

MacLaren, S. A. [Lawrence Livermore National Labor↗

Statefinder diagnostic for cosmology with the abnormally weighting energy hypothesis

In this paper, we apply the statefinder diagnostic to the cosmology with the abnormally weighting energy hypothesis (AWE cosmology), in which dark energy in the observational (ordinary matter) frame results from the violation of the weak equivalence principle by pressureless matter. It is found that there exist closed loops in the statefinder plane, which is an interesting characteristic of the evolution trajectories of statefinder parameters and can be used to distinguish AWE cosmology from other cosmological models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic age, statefinder, and Om diagnostics in the decaying vacuum cosmology

As an extension of the cosmological constant model ({lambda}CDM), the decaying vacuum (DV) model describes dark energy as a varying vacuum whose energy density decays linearly with the Hubble parameter at late times, {rho}{sub {lambda}}(t){proportional_to}H(t), and produces the matter component. We examine the high-z cosmic age problem in the DV model, and compare it with {lambda}CDM and the Yang-Mills condensate (YMC) dark energy model. Without employing a dynamical scalar field for dark energy, these three models share a similar behavior of late-time evolution. It is found that the DV model, like the YMC, can accommodate the high-z quasar APM 08279+5255, thus greatly alleviating the high-z cosmic age problem. We also calculate the statefinder (r,s) and the Om diagnostics in the model. It is found that the evolutionary trajectories of r(z) and s(z) in the DV model are similar to those in the kinessence model, but are distinguished from those in {lambda}CDM and the YMC. The Om(z) in the DV model has a negative slope and its height depends on the matter fraction, while the YMC has a rather flat Om(z), whose magnitude depends sensitively on the coupling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Primordial B-mode diagnostics and self-calibrating the CMB polarization

Distortions in the primordial cosmic microwave background (CMB) along the line of sight can be modeled and described using 11 fields. These distortion fields correspond to various cosmological signals such as weak gravitational lensing of the CMB by a large-scale structure, screening from patchy reionization, and rotation of the plane of polarization due to magnetic fields or parity violating physics. Various instrumental systematics such as gain fluctuations, pixel rotation, differential gain, pointing, and differential ellipticity are also described by the same distortion model. All these distortions produce a B mode that contaminates the primordial tensor B-modes signal. In this paper we show that, apart from generating B modes, each distortion uniquely couples different modes (l{sub 1{ne}}l{sub 2}) of the CMB anisotropies, generating <EB> correlations which for the primordial CMB are zero. We describe and implement unbiased minimum variance quadratic estimators which using the off-diagonal correlations in the CMB can extract the map of distortions. We perform Monte Carlo simulations to characterize the estimators and illustrate the level of distortions that can be detected with current and future experiments. The estimators can be used to look for cosmological signals, or to check for any residual systematics in the data. As a specific example of primordial tensor B-mode diagnostics, we compare the level of minimum detectable distortions using our method with maximum allowed distortion level for the B-modes detection. We show that for any experiment, the distortions will be detected at high significance using correlations before they would show up as spurious B modes in the power spectrum. In other words, if B modes were to be detected, the presence of any nonprimordial contribution could be checked and removed using the off-diagonal correlations in the CMB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive autoencoder latent space tuning for more robust machine learning beyond the training set for six-dimensional phase space diagnostics of a time-varying ultrafast electron-diffraction compact accelerator

In this work, we present a general adaptive latent space tuning approach for improving the robustness of machine learning tools with respect to time variation and distribution shift. We demonstrate our approach by developing an encoder-decoder convolutional neural network-based virtual 6D phase space diagnostic of charged particle beams in the HiRES ultrafast electron diffraction (UED) compact particle accelerator with uncertainty quantification. Our method utilizes model-independent adaptive feedback to tune a low dimensional 2D latent space representation of ~1 million dimensional objects which are the 15 unique 2D projections (x, y),...,(z, p z ) of the 6D phase space (x, y, z, p x , p y , p z ) of the charged particle beams. We demonstrate our method with numerical studies of short electron bunches utilizing experimentally measured UED input beam distributions.

43 PARTICLE ACCELERATORS↗

Intensity Spikes in Laser Filamentation: Diagnostics and Application

We present calculations with subcycle precision of laser-driven filamentation in argon which show that the laser peak intensity can exceed the clamping intensity by a factor of 3 during recurring spikes which can last over several centimeters of propagation. The high intensity occurs during a few-femtosecond subpulse in the trailing edge of the main pulse and gives rise to isolated 500 attosecond, 2 pJ pulses which can be extracted from the filament. We also show that the high harmonic radiation emerging from the filament is an excellent diagnostic of the intensity spikes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnostics of Mixed-State Topological Order and Breakdown of Quantum Memory

Topological quantum memory can protect information against local errors up to finite error thresholds. Such thresholds are usually determined based on the success of decoding algorithms rather than the intrinsic properties of the mixed states describing corrupted memories. Here we provide an intrinsic characterization of the breakdown of topological quantum memory, which both gives a bound on the performance of decoding algorithms and provides examples of topologically distinct mixed states. We employ three information-theoretical quantities that can be regarded as generalizations of the diagnostics of ground-state topological order, and serve as a definition for topological order in error-corrupted mixed states. We consider the topological contribution to entanglement negativity and two other metrics based on quantum relative entropy and coherent information. In the concrete example of the two-dimensional (2D) Toric code with local bit-flip and phase errors, we map three quantities to observables in 2D classical spin models and analytically show they all undergo a transition at the same error threshold. This threshold is an upper bound on that achieved in any decoding algorithm and is indeed saturated by that in the optimal decoding algorithm for the Toric code. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LossLens: Diagnostics for Machine Learning Through Loss Landscape Visual Analytics

Modern machine learning often relies on optimizing a neural network's parameters using a loss function to learn complex features. Beyond training, examining the loss function with respect to a network's parameters (i.e., as a loss landscape) can reveal insights into the architecture and learning process. While the local structure of the loss landscape surrounding an individual solution can be characterized using a variety of approaches, the global structure of a loss landscape, which includes potentially many local minima corresponding to different solutions, remains far more difficult to conceptualize and visualize. To address this difficulty, we introduce LossLens, a visual analytics framework that explores loss landscapes at multiple scales. LossLens integrates metrics from global and local scales into a comprehensive visual representation, enhancing model diagnostics. Here we demonstrate LossLens through two case studies: visualizing how residual connections influence a ResNet-20, and visualizing how physical parameters influence a physics-informed neural network (PINN) solving a simple convection problem.

97 MATHEMATICS AND COMPUTING↗

A Weakly Supervised Machine Learning Procedure for Magnet Quench Diagnostics

Voltage taps remain the standard and reliable diagnostic tool for detecting quenches in superconducting magnets. However, they identify a quench only at the time of voltage rise and do not provide information on earlier physical precursors. In this work, we investigate whether acoustic emission data can reveal precursor activity that occurs before conventional voltage detection using machine learning techniques. We introduce an event selection method and a weakly supervised machine learning procedure to learn data-driven criteria for identifying potential acoustic precursors to quenches. Two Convolutional Neural Network (CNN) architectures are trained: one on acoustic sensor events from our selection procedure and one on the Fast Fourier Transforms (FFTs) of these events. Both networks are trained iteratively using confidence-weighted loss functions to associate certain subsets of training data with a precursor label. We evaluate the performance of these models by examining the time distribution of events classified as potential precursors relative to the quench onset. Results indicate that the proposed approach can possibly distinguish acoustic emission events occurring closer to the quench from earlier acoustic activity during ramping, suggesting the potential for flagging quench precursors in acoustic data.

Khan, Maira [Fermilab] (ORCID:0009000891602387)↗

Fidelity of a Time-Resolved Imaging Diagnostic for Electron Beam Profiles

An optical tomographic diagnostic instrument has been fielded at the Dual-Axis Radiographic Hydrodynamic Test Facility at Los Alamos National Laboratory. Four optical lines of sight create projections of an image of an electron beam on a Cerenkov target, which are relayed via optical fiber to streak cameras. From these projections, a reconstruction algorithm creates time histories of the beam’s cross section. The instrument was fielded during and after facility commissioning, and tomographic reconstructions reported beam parameters. Results from reconstructions and analysis are noted.

Dual-Axis Radiographic Hydrodynamic Test, DARHT, e↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗

Real-Time Ethernet Interface for NSTX-U’s Thomson Scattering Diagnostic (2023)

Here, the multipoint Thomson scattering (MPTS) diagnostic system at the National Spherical Torus Experiment Upgrade (NSTX-U) facility is undergoing an upgrade to operate in real-time and interface with the plasma control system (PCS) for NSTX-U. Previous prototyping efforts have shown that spectral analysis and rapid calculations of electron temperature and density are possible on a real-time Linux machine when using up to a 100-Hz laser pulse repetition rate. A remaining challenge was transferring the real-time data to NSTX-U’s PCS, which utilizes the front panel data port (FPDP) protocol. The original proposed method was to convert the real-time data into analog values, but a new solution was developed to keep the output format digital by using an Ethernet controller with a field-programmable gate array (FPGA). This article focuses on a new input module that has been developed to accept incoming user datagram protocol (UDP) packets sent over Ethernet, convert into FPDP format, and integrate into the existing data stream under NSTX-U’s real-time framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of rapid diagnostics assays for detection of histoplasmosis and cryptococcosis in central american people living with HIV

Abstract Objectives Histoplasmosis and cryptococcosis are important public health problems in people living with HIV (PLHIV) in Central America. Conventional laboratory assays, based on microscopy and culture, are not optimal for the diagnosis of either disease. However, antigen (Ag) assays are rapid and highly accurate for the diagnosis of these infections. Methods Laboratory surveillance of PLHIV was carried out in four hospitals in Panama, Honduras and Nicaragua, between 2015 and 2019. Detection of Histoplasma antigens in urine was performed by enzyme immunoassay (EIA), and Cryptococcus antigen detection in sera and cerebrospinal fluid specimens was performed by lateral flow assay (LFA). Results A total of 4,453 PLHIV with clinical suspicion of histoplasmosis ( n = 1,343) or cryptococcosis ( n = 3,110; 2,721 sera and 389 CSF) were tested. Of 1,343 patients suspected of having histoplasmosis, 269 (20%) were Histoplasma Ag positive. Of 3,110 patients tested using the Cryptococcus Ag assay, 329 (11%) were positive. Honduras reported the highest positivity rates (32% for Histoplasma Ag, and 16% for Cryptococcus Ag); Panama reported the largest number of patients testing positive using the Histoplasma Ag assay ( n = 201); and Nicaragua reported the largest number of patients testing positive using the Cryptococcus Ag assay ( n = 170). Conclusion Here, we show how the implementation of rapid diagnostics assays impacted case detection and was useful for the care of people with advanced HIV. Rapid and accurate diagnosis could reduce mortality associated with histoplasmosis and cryptococcosis in PLHIV.

Caceres, Diego H.↗

Self-bias voltage diagnostics for the amorphous-to-microcrystalline transition in a-Si:H under a hydrogen-plasma treatment

The authors demonstrate the possibility of using self-bias voltage on the radio-frequency electrode of a capacitively coupled deposition system as a diagnostic tool to detect the amorphous-to-microcrystalline silicon transition during the exposure of a-Si:H thin films to a hydrogen plasma. This is achieved by combining self-bias voltage (V{sub dc}) and kinetic-ellipsometry measurements, which provide real-time information on the film properties. On intrinsic and n-type a-Si:H films, the hydrogen-plasma exposure results in the formation of a hydrogen-modified layer, which is accompanied with a decrease in the absolute values of V{sub dc}, until a plateau corresponding to the nucleation and the growth of the microcrystalline layer occurs. On p-type a-Si:H, the amorphous-to-microcrystalline transition is characterized by a rapid increase in the absolute values of V{sub dc}. This particular trend is ascribed to the effects of boron on both the solid and plasma phases.

36 MATERIALS SCIENCE↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

Fielding of a Time-Resolved Tomographic Diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an x-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, and adverse conditions will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗