Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

Particle Image Velocimetry and Total Temperature Characterization of Arc-Heated Mach 4.5 Free Jet

Particle image velocimetry (PIV) measurements were conducted in the Arc-Heated Combustion Tunnel (ACT-II) on a high-enthalpy Mach 4.5 nozzle flow. The primary motivation for the current work is to establish the feasibility of PIV as a high-quality flow diagnostic technique in hypersonic arc-heated flows and produce a high-resolution hypersonic nozzle flow characterization, including nozzle free jet shear layer velocity profiles. Due to the uncertain nature of the gas composition in the flowfield of interest, PIV measurements of a supersonic wedge flow were used to couple the flow velocities to the oblique shock relations. This enabled a PIV-derived total temperature calculation that does not require a priori assumptions of the exact gas composition. A PIV expansion module was developed for this study, and proper seed sizing and material were selected for the present flow. An analysis of the seed particle response from the PIV measurements provided an initial validation of the seed performance while revealing potential issues with consistent seed sizing. These measurements and derived conditions represent a means of acquiring high-resolution velocimetry and temperature datasets that consider uncertainties in the experimental generation of hypersonic high-enthalpy flows.

Engineering↗

In-situ and in-operando analysis of voltage losses using sense wires for proton exchange membrane water electrolyzers

Proton exchange membrane water electrolyzer development requires understanding processes at the materials and interface levels to reach the required performance and lifetime targets for increasing market penetration. To achieve the required progress, it is critical to develop advanced in-situ diagnostics that allow observation of the changes that come with the reduction of catalyst loading combined with long-term intermittent operation. This work presents an internal voltage sensing method that enables observing internal voltage drops in an operating electrolyzer cell. It allows the total cell resistance to be separated into anode, CCM, and cathode resistance. The method is demonstrated by operating cells with different anode porous transport layers (PTLs). The changing properties of the PTLs result in significant variations of the resistances. Enhancing the PTL properties with a protective coating reduces the anode resistance significantly. In addition to these observations, the method enables a real-time monitoring of resistance related values that impact performance in water electrolyzers. Long-term experiments with the method allow us to gain insights into processes that occur during operation such as conditioning or degradation. The internal voltage sensing method presented in this study is a novel technique for diagnosing, analyzing, and optimizing water electrolyzers and other energy conversion devices.

42 ENGINEERING↗

Developing a bright 17 keV x-ray source for probing high-energy-density states of matter at high spatial resolution

A set of experiments were performed on the National Ignition Facility (NIF) to develop and optimize a bright, 17 keV x-ray backlighter probe using laser-irradiated Nb foils. High-resolution one-dimensional imaging was achieved using a 15 μm wide slit in a Ta substrate to aperture the Nb He{sub α} x-rays onto an open-aperture, time integrated camera. To optimize the x-ray source for imaging applications, the effect of laser pulse shape and spatial profile on the target was investigated. Two laser pulse shapes were used—a “prepulse” shape that included a 3 ns, low-intensity laser foot preceding the high-energy 2 ns square main laser drive, and a pulse without the laser foot. The laser spatial profile was varied by the use of continuous phase plates (CPPs) on a pair of shots compared to beams at best focus, without CPPs. A comprehensive set of common diagnostics allowed for a direct comparison of imaging resolution, total x-ray conversion efficiency, and x-ray spectrum between shots. The use of CPPs was seen to reduce the high-energy tail of the x-ray spectrum, whereas the laser pulse shape had little effect on the high-energy tail. The measured imaging resolution was comparably high for all combinations of laser parameters, but a higher x-ray flux was achieved without phase plates. This increased flux was the result of smaller laser spot sizes, which allowed us to arrange the laser focal spots from multiple beams and produce an x-ray source which was more localized behind the slit aperture. Our experiments are a first demonstration of point-projection geometry imaging at NIF at the energies (>10 keV) necessary for imaging denser, higher-Z targets than have previously been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic feature design for cycle life prediction of lithium-ion batteries during formation

Optimization of the formation step in lithium-ion battery manufacturing is challenging due to limited physical understanding of solid-electrolyte interphase formation and the long testing time (∼100 days) for cells to reach the end of life. We propose a systematic feature-design framework that requires minimal domain knowledge for accurate cycle life prediction during formation. By only using two simple Q (V) features designed from our framework, extracted from formation data without any additional diagnostic cycles, we achieved an average of 9.87% error for cycle life prediction. Here, the physics-based investigation guided by the two designed features shows that the voltage ranges identified by our framework capture the effects of formation temperature and microscopic-particle resistance heterogeneity. By designing highly predictive, robust, and interpretable features, our approach can accelerate industrial battery formation research, leveraging the interplay between data-driven feature design and mechanistic understanding.

25 ENERGY STORAGE↗

Application of high-speed, species-specific chemiluminescence imaging for laminar flame speed and Markstein length measurements in spherically expanding flames

A high-speed chemiluminescence imaging diagnostic system has been developed and characterized for measuring species-specific properties of spherically expanding flames, with the objective of obtaining synchronized measurements of multiple flame properties from a single flame experiment. The imaging system comprises a high-speed camera coupled to a high-speed image intensifier and optical filters to isolate emission from desired excited species. Here this study validates the diagnostic scheme specifically for measuring laminar flame speed and Markstein length from chemiluminescence at three wavelength bands corresponding to OH*, CH*, and total chemiluminescence, respectively. Mixtures of methane-air and methane/ethane-air were tested at initial conditions of atmospheric pressure and room temperature. An under-utilized methodology for computing unburned Markstein length from burned Markstein length was implemented. Flame speed modeling of each mixture was conducted in Chemkin using AramcoMech 2.0. No significant differences were observed between the results derived from the three emission wavelength bands for the flame speeds nor the Markstein lengths. For both of these properties, excellent agreement was observed between the experimental results and the values reported in the literature. Because laminar flame speed and Markstein length show no dependency on the imaging wavelength, the present results imply that multiple flame properties, such as laminar flame speed, Markstein length, flame thickness, and excited-species intensity profiles, can all be acquired simultaneously for the same flame using this method.

42 ENGINEERING↗

High-Resolution 3D Acoustic Borehole Integrity Monitoring (Final Report)

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

42 ENGINEERING↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Report Q3FY21 - High-Resolution 3D Acoustic Borehole Integrity Monitoring

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO 2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

42 ENGINEERING↗

Mondo: integrating disease terminology across communities

Precision medicine aims to enhance diagnosis, treatment, and prognosis by integrating multimodal data at the point of care. However, challenges arise due to the vast number of diseases, differing methods of classification, and conflicting terminological coding systems and practices used to represent molecular definitions of disease. This lack of interoperability artificially constrains the potential for diagnosis, clinical decision support, care outcome analysis, as well as data linkage across research domains to support the development or repurposing of therapeutics. There is a clear and pressing need for a unified system for managing disease entities⁠—including identifiers, synonyms, and definitions. To address these issues, we created the Mondo disease ontology—a community-driven, open-source, unified disease classification system that harmonizes diverse terminologies into a consistent, computable framework. Mondo integrates key medical and biomedical terminologies, including Online Mendelian Inheritance in Man (OMIM), Orphanet, Medical Subject Headings (MeSH), National Cancer Institute Thesaurus (NCIt), and more, to provide a comprehensive and accurate representation of disease concepts with fully provenanced and attributed links back to the sources. Mondo can be used as the handle for curation of gene–disease associations utilized in diagnostic applications, research applications such as computational phenotyping, and in clinical coding systems in clinical decision support by pointing the clinician to the numerous knowledge resources linked to the Mondo identifier. Mondo's community-centric approach, stewarded by the Monarch Initiative's expertise in ontologies, ensures that the ontology remains adaptable to the evolving needs of biomedical research and clinical communities, as well as the knowledge providers.

biomedical informatics↗

Highly Sensitive Electro-Optic Modulators

There are very important diagnostic and communication applications that receive faint electrical signals to be transmitted over long distances for capture. Optical links reduce bandwidth and distance restrictions of metal transmission lines; however, such signals are only weakly imprinted onto the optical carrier, resulting in low fidelity transmission. Increasing signal fidelity often necessitates insertion of radio-frequency (RF) amplifiers before the electro-optic modulator, but (especially at high frequencies) RF amplification results in large irreversible distortions. We have investigated the feasibility of a Sensitive and Linear Modulation by Optical Nonlinearity (SALMON) modulator to supersede RF-amplified modulators. SALMON uses cross-phase modulation, a manifestation of the Kerr effect, to enhance the modulation depth of an RF-modulated optical wave. This ultrafast process has the potential to result in less irreversible distortions as compared to a RF-amplified modulator due to the broadband nature of the Kerr effect. Here, we prove that a SALMON modulator is a feasible alternative to an RFamplified modulator, by demonstrating a sensitivity enhancement factor greater than 20 and significantly reduced distortion.

42 ENGINEERING↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

A Thermal and Nanomechanical Study of Molecular Crystals as Versatile Mocks for Pentaerythritol Tetranitrate

Pentaerythritol tetranitrate (PETN) is a commonly used high explosive (HE) in detonators. Often, surrogate or “mock” materials are used in place of HE for mechanical tests, proofing out equipment, or developing new diagnostics. However, there is no commonly accepted mock for PETN. A good mock should match at least one physical property of the target material, and ideally mimic multiple thermal and mechanical properties. Here, we investigate several molecular crystals to evaluate their efficacy in mocking PETN density, melting point, elastic modulus, hardness, plastic deformation, and fracture behavior. Materials were tested with a combination of calorimetry and nanoindentation. Two materials, 2,4,6-trifluorobenzoic acid (246 TFBA) and mesoerythritol, were downselected for detailed indentation study after the initial round of screening experiments, both were found to mimic PETN mechanical behavior quite well, 246 TFBA closer to PETN in most properties (hardness, modulus, and density) than erythritol, but erythritol having advantages in relative cost and matching the onset of yield. Depending on the desired implementation of the mock, one material may be preferred over the other, but both have potential as generic mocks for PETN. Nanoindentation is demonstrated as a versatile tool to provide rapid screening of these materials’ mechanical properties.

42 ENGINEERING↗

High-Resolution 3D Acoustic Borehole Integrity Monitoring (Research Performance Progress Report Q2 2021)

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

15 GEOTHERMAL ENERGY↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf For EnergyPlus® and OpenStudio®, generation of test cases, simulation, and reporting has been a manual or partially automated process that typically took a number of months after a new version of EnergyPlus came out. Building Energy Simulation Test - Generation Simulation and Reporting (BESTEST-GSR) was developed to fully automate this process so it is less error-prone, less time-consuming, and can be quickly run on request for any development branch of EnergyPlus and OpenStudio. The initial use case is to directly support OpenStudio and EnergyPlus development, but the software is configured to support use by external software developers that build tools on top of EnergyPlus and/or OpenStudio. Tools built on top of OpenStudio can leverage the test generation, simulation, and reporting, while tools built on EnergyPlus can leverage the test simulation and reporting. The model generation is accomplished by running OpenStudio measures for envelope, heating, or cooling test cases. At this stage the specified weather file required for a specific test case is assigned to the model. Simulation is enabled using the OpenStudio Command Line Interface (CLI) to run a series of OpenStudio and Reporting measures to a specified seed model. The specified workflow is defined with an OpenStudio OSW file. The first measure generates the test case model, while the second measure is a reporting measure that runs after the simulation to collect necessary simulation results from the EnergyPlus SQL file. The Reporting stage gathers data from individual OpenStudio OSW files and populates a series of BESTEST Microsoft Excel spreadsheets. BESTEST-GSR also gathers zip files from individual simulations for diagnostic purposes.

Goldwasser, David↗

Quantitative near-field water–air spray measurements at elevated pressures by neutron radiography imaging

Extensive experimental research on high-pressure spray has been conducted for decades to deepen our understanding and optimize its use in transportation, aviation, and propulsion applications; however, the near-field and in-nozzle flow characteristics are not fully understood. Dense near-field spray is among the most challenging diagnostic tasks since light is severely scattered and diffused by the liquid droplets and columns. In this work, the near-field spray and in-nozzle flow characteristics of an aeration nozzle at elevated pressures were characterized by neutron radiography imaging at the Oak Ridge National Laboratory High Flux Isotope Reactor. Neutron imaging benefits via strong penetration depths for some metals (i.e., aluminum, lead, and steel) and is sufficiently sensitive to detection of light elements, especially for hydrogen-based molecules, due to the large incoherent scattering cross section of neutrons. Both two-dimensional snapshots of the near-field spray and a three-dimensional tomographic scan of the nozzle geometry and in-nozzle water were obtained. This work provides new quantitative characterization of practical metal nozzle geometry for accurate boundary conditions, internal flow patterns inside the nozzle, and high-pressure spray flows. In conclusion, the findings may be used to improve performance and operating conditions of transportation vehicles and propulsion systems.

42 ENGINEERING↗

On the Prospect of Chemically Transferable Coarse-Grained Electronic Models for Soft Materials

Electronic coarse-graining (ECG) methods predict quantum-mechanical electronic properties directly from coarse-grained (CG) molecular configurations, enabling electronic predictions at mesoscale length scales. Here, we present a diagnostic assessment of the feasibility of chemically transferable ECG models across a broad polymer-relevant chemical space using all-atom, united-atom, and Martini-scale representations. While high-resolution ECG models achieve near-quantitative accuracy, we show that chemically transferable ECG at the Martini resolution fails because the CG force field does not sample the same configurational distribution of local molecular structure as that underlying the DFT-parameterized ECG model. We demonstrate that our proposed Element-Count-Label (ECL) representation, which augments Martini beads with explicit stoichiometric data, significantly improves chemical generalization across diverse polymer chemistries. However, we find that even with improved chemical resolution, the model cannot recover electronic property distributions that are absent from the configurational space sampled by the CG force field. These results demonstrate that chemically transferable ECG requires future Martini-like force fields to explicitly preserve quantum chemistry–compatible local molecular structure in addition to thermodynamic and structural fidelity.

Kidder, Katherine M [Department of Chemistry; Univ↗

Refine your search to explore more results.