Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

HIGH-ENERGY X-RAY PINHOLE CAMERA FOR HIGH-RESOLUTION ELECTRON BEAM SIZE MEASUREMENTS

The Advanced Photon Source (APS) is developing a multi-bend achromat (MBA) lattice based storage ring as the next major upgrade, featuring a 20-fold reduction in emittance. Combining the reduction of beta functions, the electron beam sizes at bend magnet sources may be reduced to reach 5 – 10 µm for 10% vertical coupling. The x-ray pinhole camera currently used for beam size monitoring will not be adequate for the new task. By increasing the operating photon energy to 120 – 200 keV, the pinhole camera’s resolution is expected to reach below 4 µm. The peak height of the pinhole image will be used to monitor relative changes of the beam sizes and enable the feedback control of the emittance. We present the simulation and the design of a beam size monitor for the APS storage ring.

Yang, B.↗

X-ray emission possibly coincident with the radio tail of PKS 0301 - 123

X-ray, radio, and optical observations are reported for a very poor cluster of galaxies containing the radio source PKS 0301 - 123. A long, 100,000 second X-ray observation using the Einstein Observatory's IPC resulted in the serendipitous discovery of a peculiar extended X-ray morphology associated with the poor cluster. The X-ray emission is extended in the same direction and is approximately the same length as the radio-tailed source, PKS 0301 - 123, which was mapped at 6 and 20 cm with the VLA. Optical redshift observations with the KPNO IIDS on the 2.1 m telescope confirm the identification of the X-ray and radio emission with the poor cluster at z = 0.1. It is argued that the X-ray extension is unlikely to be a chance coincidence of a background source projected onto the foreground cluster. Therefore, four possible mechanisms which might physically link the X-ray and radio emission are considered: thermal bremsstrahlung from a cluster with a flattened potential well; inverse Compton scattering of the relativistic electrons in the radio source, X-ray synchrotron radiation; and heating the cluster gas by the turbulent wake of the radio galaxy. The prospects for future observations of such X-ray/radio coincidences are briefly discussed.

Burns, J. O.↗

DIY XES-development of an inexpensive, versatile, and easy to fabricate XES analyzer and sample delivery system

The application of X-ray emission spectroscopy (XES) has grown substantially with the development of X-ray free-electron lasers, third and fourth generation synchrotron sources, and high-power benchtop sources. By providing the high X-ray flux required for XES, these sources broaden the availability and application of this method of probing electronic structure. As the number of sources increase, so does the demand for X-ray emission detection and sample delivery systems that are cost effective and customizable. In this work, we present a detailed fabrication protocol for von Hamos X-ray optics and give details for a 3D-printed spectrometer design. Additionally, we outline an automated, externally triggered liquid sample delivery system that can be used to repeatedly deliver nanoliter droplets onto a plastic substrate for measurement. These systems are both low cost, efficient, and easy to recreate or modify depending on the application. A low cost multiple X-ray analyzer system enables measurement of dilute samples, whereas the sample delivery limits sample loss and reproducibly replaces spent sample with fresh sample in the same position. While both systems can be used in a wide range of applications, the design addresses several challenges associated specifically with time-resolved XES (TRXES). As an example application, we show results from TRXES measurements of photosystem II, a dilute, photoactive protein.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of ion beams for space effects testing using an ECR ion source

At LBNL's 88-Inch Cyclotron and Berkeley Accelerator Space Effects (BASE) Facility, a range of ion beams at energies from 1 to 55 MeV/nucleon are used for radiation space effects testing. By bombarding a component with ion beams the radiation component of the space environment can be simulated and single event effects (SEEs) determined. The performance of electronic components used in space flight and high altitude aircraft can then be evaluated. The 88- Inch Cyclotron is coupled to the three electron cyclotron resonance ion sources (ECR, AECR-U, VENUS). These ion sources provide a variety of ion species, ranging from protons to heavy ions such as bismuth, for these tests. In particular the ion sources have been developed to provide {sup c}ocktails{sup ,} a mixture of ions of similar mass-to-charge ratio, which can be simultaneously injected into the cyclotron, but selectively extracted from it. The ions differ in both their linear energy transfer (LET) deposited to the part and in their penetration depth into the tested part. The current heavy ion cocktails available are the 4.5, 10, 16, and 30 MeV per nucleon.

43 PARTICLE ACCELERATORS↗

A simple photoionization scheme for characterizing electron and ion spectrometers

We present a simple diode laser-based photoionization scheme for generating electrons and ions with well-defined spatial and energetic (≲2 eV) structures. This scheme can easily be implemented in ion or electron imaging spectrometers for the purpose of off-line characterization and calibration. The low laser power ∼1 mW needed from a passively stabilized diode laser and the low flux of potassium atoms in an effusive beam make our scheme a versatile source of ions and electrons for applications in research and education.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A soft ring oscillator

Periodic actuation of multiple soft, pneumatic actuators requires coordinated function of multiple, separate components. This work demonstrates a soft, pneumatic ring oscillator that induces temporally coordinated periodic motion in soft actuators using a single, constant-pressure source, without hard valves or electronic controls. The fundamental unit of this ring oscillator is a soft, pneumatic inverter (an inverting Schmitt trigger) that switches between its two states (“on” and “off”) using two instabilities in elastomeric structures: buckling of internal tubing and snap-through of a hemispherical membrane. An odd number of these inverters connected in a loop produces the same number of periodically oscillating outputs, resulting from a third, system-level instability; the frequency of oscillation depends on three system parameters that can be adjusted. These oscillatory output pressures enable several applications, including undulating and rolling motions in soft robots, size-based particle separation, pneumatic mechanotherapy, and metering of fluids. The soft ring oscillator eliminates the need for hard valves and electronic controls in these applications.

Robotics↗

X-ray spectra of A0620-00 obtained with a Bragg crystal spectrometer

The OSO 8 graphite crystal spectrometer was used to obtain observations, in October 1975 and January 1976, of the transient X-ray source A0620-00, which yield upper limits of no more than about 10 eV to the equivalent widths of narrow emission lines of Si XIII, Si XIV, S XV, and S XVI. Photoionization is unlikely to alter the principal conclusion that the electron scattering in the source is substantial. High-resolution spectra obtained in October 1975 reveal a featureless continuum which is better characterized as blackbody (kT about 0.5 keV) than as thin bremsstrahlung emission.

Long, K. S.↗

ComDMFT: A massively parallel computer package for the electronic structure of correlated-electron systems

ComDMFT is a massively parallel computational package to study the electronic structure of correlated-electron systems (CES). Our approach is a parameter-free method based on ab initio linearized quasiparticle self-consistent GW (LQSGW) and dynamical mean field theory (DMFT). The non-local part of the electronic self-energy is treated within ab initio LQSGW and the local strong correlation is treated within DMFT. In addition to ab initio LQSGW+DMFT, charge self-consistent LDA+DMFT methodology is also implemented, enabling multiple methods in one open-source platform for the electronic structure of CES. Here, this package can be extended for future developments to implement other methodologies to treat CES.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental determination of the elastic cotunneling rate in a hybrid single-electron box

We report measurements of charge configurations and charge transfer dynamics in a hybrid single-electron box composed of aluminum and copper. We used two single-electron transistors (SETs) to simultaneously read out different parts of the box, enabling us to map out stability diagrams of the box and identify various charge transfer processes in the box. We further characterized the elastic cotunneling in the box, which is an important source of error in electron turnstiles consisting of hybrid SETs, and found that the rate was as low as 1 Hz at degeneracy and compatible with theoretical estimates for electron tunneling via virtual states in the central superconducting island of the box.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasi-isentropic compressibility of a strongly nonideal deuterium plasma at pressures of up to 5500 GPa: Nonideality and degeneracy effects

We report on the experimental results on the quasi-isentropic compressibility of a strongly nonideal deuterium plasma that have been obtained on setups of cylindrical and spherical geometries in the pressure range of up to P ≈ 5500 GPa. We describe the characteristics of experimental setups, as well as the methods for the diagnostics and interpretation of the experimental results. The trajectory of metal shells that compress the deuterium plasma was detected using powerful pulsed X-ray sources with a maximal electron energy of up to 60 MeV. The values of the plasma density, which varied from ρ ≈ 0.8 g/cm{sup 3} to ρ ≈ 6 g/cm{sup 3}, which corresponds to pressure P ≈ 5500 GPa (55 Mbar), were determined from the measured value of the shell radius at the instant that it was stopped. The pressure of the compressed plasma was determined using gasdynamic calculations taking into account the actual characteristics of the experimental setups. We have obtained a strongly compressed deuterium plasma in which electron degeneracy effects under the conditions of strong interparticle interaction are significant. The experimental results have been compared with the theoretical models of a strongly nonideal partly degenerate plasma. We have obtained experimental confirmation of the plasma phase transition in the pressure range near 150 GPa (1.5 Mbar), which is in keeping with the conclusion concerning anomaly in the compressibility of the deuterium plasma drawn in [1].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method of aligning a laser-based radiation source

A method for temporally and spatially aligning a laser-based x-ray source and maintaining alignment is disclosed. A pump laser beam, which interacts with a plasma source to create an electron beam, is aligned with the electron beam. A scattering laser beam is overlapped with the pump laser beam at an intersection point. The pump laser beam and scattering laser beam alignments are monitored and adjusted to maintain optimal alignment during operation of the laser-based x-ray source.

Umstadter, Donald↗

Cyclotron instability in the afterglow mode of minimum-B ECRIS

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. It was found that even in various gases (helium and oxygen were studied) and at different values of magnetic field and heating power, the dynamic spectra demonstrate common features: decreasing frequency within a single burst as well as from one burst to another.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the direct and dissociative excitation of the O(3s 3S0) state by electron impact on atomic and molecular oxygen

The ratio of the cross sections for the direct and dissociative excitation of the OI(3s 3S0-2p 3P; 1304 A wavelength) transition, sigma A/sigma D, are accurately determined, and the sigma A/sigma D ratio is directly normalized to the ratio of the O(+) and O2(+) ionization cross sections using a high-density diffuse gas source, an electrostatically focused electron gun, a vacuum-ultraviolet monochromater, and a quadrupole mass spectrometer for simultaneous optical and composition measurements. Using revised sigma A(1304 A) values calculated with new calibration standards, the shape of the cross section for the excitation of the O(3s 3S0) state agrees well with previous results, though the absolute magnitude of sigma A(1304 A) is smaller than the results of Stone and Zipf (1974) by a factor of 2.8. The revised cross sections agree well with recent quantum calculations when cascade excitation of the 3s 3S0 state is taken into account.

Zipf, E. C.↗

Handling radiation generated during an ion source commissioning

Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H{sup +} ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D{sup +} beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.

43 PARTICLE ACCELERATORS↗

Search for an axion-induced oscillating electric dipole moment for electrons using atomic magnetometers

We propose an experimental search for an axion-induced oscillating electric dipole moment (OEDM) for electrons using state-of-the-art alkali vapor-cell atomic magnetometers. The axion is a hypothesized new fundamental particle which can resolve the strong charge-parity problem and be a prominent dark matter candidate. This experiment utilizes an atomic magnetometer as both a source of optically polarized electron spins and a magnetic-field sensor. The interaction of the axion field, oscillating at a frequency equal to the axion mass, with an electron spin induces a sizable OEDM of the electron at the same frequency as the axion field. When the alkali vapor is subjected to an electric field and a magnetic field, the electron OEDM interacts with the electric field, resulting in an electron spin precession at the spin’s Larmor frequency in the magnetic field. The resulting precession signal can be sensitively detected with a probe laser beam of the atomic magnetometer. We estimate that the experiment is sensitive to the axion-photon interaction in ultralight axion masses from 10 -15 to 10 -10 eV. It is able to improve the current experimental limit up to 5 orders of magnitude, exploring new axion parameter spaces.

74 ATOMIC AND MOLECULAR PHYSICS↗

Recent progress in high-temperature superconducting undulators

Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.

43 PARTICLE ACCELERATORS↗

A localized view on molecular dissociation via electron-ion partial covariance

Inner-shell photoelectron spectroscopy provides an element-specific probe of molecular structure, as core-electron binding energies are sensitive to the chemical environment. Short-wavelength femtosecond light sources, such as Free-Electron Lasers (FELs), even enable time-resolved site-specific investigations of molecular photochemistry. Here, we study the ultraviolet photodissociation of the prototypical chiral molecule 1-iodo-2-methylbutane, probed by extreme-ultraviolet (XUV) pulses from the Free-electron LASer in Hamburg (FLASH) through the ultrafast evolution of the iodine 4d binding energy. Methodologically, we employ electron-ion partial covariance imaging as a technique to isolate otherwise elusive features in a two-dimensional photoelectron spectrum arising from different photofragmentation pathways. The experimental and theoretical results for the time-resolved electron spectra of the 4d 3/2 and 4d 5/2 atomic and molecular levels that are disentangled by this method provide a key step towards studying structural and chemical changes from a specific spectator site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refine your search to explore more results.