Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Scaling Linear Algebra Kernels using Remote Memory Access

This paper describes the scalability of linear algebra kernels based on remote memory access approach. The current approach differs from the other linear algebra algorithms by the explicit use of shared memory and remote memory access (RMA) communication rather than message passing. It is suitable for clusters and scalable shared memory systems. The experimental results on large scale systems (Linux-Infiniband cluster, Cray XT) demonstrate consistent performance advantages over ScaLAPACK suite, the leading implementation of parallel linear algebra algorithms used today. For example, on a Cray XT4 for a matrix size of 102400, our RMA-based matrix multiplication achieved over 55 teraflops while ScaLAPACK’s pdgemm measured close to 42 teraflops on 10000 processes.

99 GENERAL AND MISCELLANEOUS↗

Crystalline symmetry-protected non-trivial topology in prototype compound BaAl 4

The BaAl 4 prototype crystal structure is the most populous of all structure types, and is the building block for a diverse set of sub-structures including the famous ThCr 2 Si 2 family that hosts high-temperature superconductivity and numerous magnetic and strongly correlated electron systems. The MA 4 family of materials (M = Sr, Ba, Eu; A = Al, Ga, In) themselves present an intriguing set of ground states including charge and spin orders, but have largely been considered as uninteresting metals. We predict the exemplary compound BaAl 4 to harbor a three-dimensional Dirac spectrum with non-trivial topology and possible nodal lines crossing the Brillouin zone, wherein one pair of semi-Dirac points with linear dispersion along the k z direction and quadratic dispersion along the k x / k y direction resides on the rotational axis with C 4 v point group symmetry. An extremely large, unsaturating positive magnetoresistance in BaAl 4 despite an uncompensated band structure is revealed, and quantum oscillations and angle-resolved photoemission spectroscopy measurements confirm the predicted multiband semimetal structure with pockets of Dirac holes and a Van Hove singularity (VHS) remarkably consistent with the theoretical prediction. We thus present BaAl 4 as a topological semimetal, casting its prototype status into a role as a building block for a vast array of topological materials.

36 MATERIALS SCIENCE↗

Experiment to demonstrate separation of Cherenkov and scintillation signals

The ability to separately identify the Cherenkov and scintillation light components produced in scintillating mediums holds the potential for a major breakthrough in neutrino detection technology, allowing development of a large, low-threshold, directional detector with a broad physics program. Furthermore, the CHESS (CHErenkov/Scintillation Separation) experiment employs an innovative detector design with an array of small, fast photomultiplier tubes and state-of-the-art electronics to demonstrate the reconstruction of a Cherenkov ring in a scintillating medium based on photon hit time and detected photoelectron density. Our paper describes the physical properties and calibration of CHESS along with first results. The ability to reconstruct Cherenkov rings are demonstrated in a water target, and a time precision of 338 ± 12 ps FWHM is achieved. Finally, Monte Carlo–based predictions for the ring imaging sensitivity with a liquid scintillator target predict an efficiency for identifying Cherenkov hits of 94 ± 1 % and 81 ± 1 % in pure linear alkyl benzene (LAB) and LAB loaded with 2 g/L of a fluor, PPO, respectively, with a scintillation contamination of 12 ± 1 % and 26 ± 1 % .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Laser Interferometric Miniature Sensor

This is the second year of a Phase II Small Business Innovation Research (SBIR) contract geared towards the development of a new seismic sensor. Ground-based seismic monitoring systems have proven to be very capable in identifying nuclear tests, and can provide somewhat precise information on the location and yield of the explosive device. Making these measurements, however, currently requires very expensive and bulky seismometers that are difficult to deploy in places where they are most needed. A high performance, compact device can enable rapid deployment of large scale arrays, which can in turn be used to provide higher quality data during times of critical need. The use of a laser interferometer-based device has shown considerable promise, while also presenting significant challenges. The greatest strength of this optical readout technique is the ability to decouple the mechanical design from the transducer, thus enabling a miniaturized design that is not accessible with conventional sensing techniques. However, the nonlinearity in the optical response must be accounted for in the sensor output. Previously, we had proposed using a force-feedback approach to position the sensor at a point of maximum linearity. However, it can be shown that the combined nonlinearities of the optical response and the force-feedback curve necessarily results in a significant amount of unwanted noise at low frequencies. Having realized this, we have developed a new approach that eliminates force feedback, allowing the proof mass to move freely at all times. This takes advantage of some advanced optical spatial filtering that was developed at Symphony Acoustics for other types of sensors, and was recently adapted to this work. After processing the signals in real time, the digital output of the device is intrinsically linear, and the sensor can operate at any orientation with the same level of resolution, while instantly adapting to significant changes in orientation. Ultimately, we expect the dynamic range to be up to 180 dB. Currently, we have observed the noise floor in a 0.1 Hz to 10 Hz bandwidth to be near -160 dB/Hz relative to 1 m2/s4. To meet the objectives of this program, we are finalizing the design of a 3 axis sensor for shallow borehole deployments, with a diameter of 40 mm and a length a 150 mm.

47 OTHER INSTRUMENTATION↗

Minimizing Timing Jitter’s Impact on Ground-Penetrating Radar Array Coupling Signals

This article presents a novel investigation into the effect of receiver timing jitter on the quality of imaging of ground-penetrating radar systems. We explicitly show the impact of timing jitter throughout an entire example processing pipeline. The process of coupling removal in systems whose receivers have a random Gaussian-distributed jitter with a high standard deviation leaves randomly distributed residue in the radar image. This residue, called jitter-induced coupling noise, extends even into the expected target domain which may cause false alarms. This residue approximately follows a sum of Gaussian and Gamma distributions based on the higher order derivatives of the coupling signal. Once migrated to create an image, the coupling residue is best described by a Weibull distribution. We show that simple filtering does not remove enough residue and propose two preventative design specifications called the linear slope and migrated probability specifications. Antenna and system designers should use these specifications to assess the true severity of coupling signals in a given jitter environment.

47 OTHER INSTRUMENTATION↗

Preparation for quantum simulation of the ( 1 + 1 ) -dimensional O(3) nonlinear σ model using cold atoms

The 1+1D O(3) non-linear σ-model is a model system for future quantum lattice simulations of other asymptotically-free theories, such as non-Abelian gauge theories. We find that utilizing dimensional reduction can make efficient use of two-dimensional layouts presently available on cold atom quantum simulators. A new definition of the renormalized coupling is introduced, which is applicable to systems with open boundary conditions and can be measured using analog quantum simulators. Monte Carlo and tensor network calculations are performed to determine the quantum resources required to reproduce perturbative short-distance observables. In particular, we show that a rectangular array of 48 Rydberg atoms with existing quantum hardware capabilities should be able to adiabatically prepare low-energy states of the perturbatively-matched theory. Furthermore, these states can then be used to simulate non-perturbative observables in the continuum limit that lie beyond the reach of classical computers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream from the patient. Both systems demonstrate substantial utility for online treatment verification and QA of photon external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finite Element Analysis of a Deployable Space Structure

The dynamic characteristics of the Solar Array Flight Experiment (SAFE) structure during deployment and retraction are investigated. The SAFE structure consists of a deployable mast with an attached solar blanket designed with accordion type folds to permit packaging in a small volume. The planar form of the blanket geometry during deployment is maintained by a blanket tension/guidewire system. Structurally, the mast is modeled as an Euler beam column with inplane and out of plane bending and finite torsional stiffness. For out of plane motion, the blanket is modeled as a distributed mass uniformly supported by the three guidewires. For inplane motion the blanket displacements are assumed to vary linearly from the mast base to the mast tip. The mathematical model uses a virtual work formulation, required because the axial loading on the mast is nonconservative, combined with assumed beam modes to derive the differential equations of motion. Consideration of the time dependent boundary conditions results in an infinite set of ODE with time dependent coefficients. Finally, correlation of mast tip accelerations to mast base bending moments for specified modal motions are indicated.

Weeks, G. E.↗

Analysis and Enhancement of Low-Light-Level Performance of Photodiode-Type CMOS Active Pixel Images Operated with Sub-Threshold Reset

Noise in photodiode-type CMOS active pixel sensors (APS) is primarily due to the reset (kTC) noise at the sense node, since it is difficult to implement in-pixel correlated double sampling for a 2-D array. Signal integrated on the photodiode sense node (SENSE) is calculated by measuring difference between the voltage on the column bus (COL) - before and after the reset (RST) is pulsed. Lower than kTC noise can be achieved with photodiode-type pixels by employing "softreset" technique. Soft-reset refers to resetting with both drain and gate of the n-channel reset transistor kept at the same potential, causing the sense node to be reset using sub-threshold MOSFET current. However, lowering of noise is achieved only at the expense higher image lag and low-light-level non-linearity. In this paper, we present an analysis to explain the noise behavior, show evidence of degraded performance under low-light levels, and describe new pixels that eliminate non-linearity and lag without compromising noise.

Pain, Bedabrata↗

SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Method development for comprehensive extraction and analysis of marine toxins: Liquid-liquid extraction and tandem liquid chromatography separations coupled to electrospray tandem mass spectrometry

Toxins from biological sources are recognized as potential chemical weapon threats, with saxitoxin and ricin listed by the chemical weapons convention (CWC) as schedule one agents (CWC reference). These two toxins represent a metabolite (saxitoxin) and protein (ricin) from algal and plant sources, respectively. An array of toxins have been listed as "select agents" by the Health and Human Services (HHS) select agent program, including ricin, abrin, saxitoxin, tetrodotoxin, specific paralytic alpha conotoxin peptides, T-2 toxin, diacetoxyscirpenols, botulinum toxins, and staphylococcal enterotoxins [1]. The quantities of these toxins dictate whether they are considered select agents with federal oversight of their storage and use. While this list captures some of the naturally occurring toxins that may pose a threat to the public, there are a number of other naturally occurring toxins that may also be a concern.

biodetection↗

The GlueX Start Counter and Beam Asymmetry$\Sigma$ in Single $\pi^{0}$ Photoproduction

The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H 2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 10 8 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\vec{p}$→ π 0 p, where π 0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

25-Pin metallic fuel performance benchmark case based on the EBR-II X430 experiments series

A metallic fuel benchmark case was developed for the fuel performance code BISON based on 25 uranium-zirconium and uranium-plutonium-zirconium pins of the Experimental Breeder Reactor II X430 experiment series. Results of the benchmarks were compared with measurements and calculations made at the time of the experiment as well as subsequent measurements reported in 2019. The comparisons were used to quantify the accuracy of the BISON predictions and to identify patterns in the BISON differences.BISON predicted burnup, plenum pressure, and fission gas release fractions accurately. BISON temperature predictions were somewhat cooler than the temperatures determined at the time of the experiment but appeared to be reasonably accurate considering uncertainties in the legacy temperature calculations, uncertainties in the legacy linear heat rate calculations, and the high sensitivities of the BISON-predicted temperatures to BISON inputs. Fuel axial elongation predictions had errors correlated to fuel composition; BISON tended to underpredict the elongation of binary fuels and overpredict the elongation of ternary fuels. BISON cladding radial dilation predictions were also significantly lower than legacy PIE measurements.Recommendations were made to improve the BISON fuel gaseous swelling model to account for fuel composition, to add additional capabilities to the coolant channel temperature model to ease benchmark development, and to continue developing benchmark cases based on a wide range of experiments in several reactors. Once a wide array of benchmarks is developed, an attempt can be made to enhance or calibrate BISON models to improve the cladding dilation predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-247: Multi-Leaf Collimator Model Adjustments Improve Small Field Dosimetry in VMAT Plans

Purpose: The Elekta beam modulator linac employs a 4-mm micro multileaf collimator (MLC) backed by a fixed jaw. Out-of-field dose discrepancies between treatment planning system (TPS) calculations and output water phantom measurements are caused by the 1-mm leaf gap required for all moving MLCs in a VMAT arc. In this study, MLC parameters are optimized to improve TPS out-of-field dose approximations. Methods: Static 2.4 cm square fields were created with a 1-mm leaf gap for MLCs that would normally park behind the jaw. Doses in the open field and leaf gap were measured with an A16 micro ion chamber and EDR2 film for comparison with corresponding point doses in the Pinnacle TPS. The MLC offset table and tip radius were adjusted until TPS point doses agreed with photon measurements. Improvements to the beam models were tested using static arcs consisting of square fields ranging from 1.6 to 14.0 cm, with 45° collimator rotation, and 1-mm leaf gap to replicate VMAT conditions. Gamma values for the 3-mm distance, 3% dose difference criteria were evaluated using standard QA procedures with a cylindrical detector array. Results: The best agreement in point doses within the leaf gap and open field was achieved by offsetting the default rounded leaf end table by 0.1 cm and adjusting the leaf tip radius to 13 cm. Improvements in TPS models for 6 and 10 MV photon beams were more significant for smaller field sizes 3.6 cm or less where the initial gamma factors progressively increased as field size decreased, i.e. for a 1.6cm field size, the Gamma increased from 56.1% to 98.8%. Conclusion: The MLC optimization techniques developed will achieve greater dosimetric accuracy in small field VMAT treatment plans for fixed jaw linear accelerators. Accurate predictions of dose to organs at risk may reduce adverse effects of radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Gravitational Waves as a Source of Large-Scale White Noise: New Constraints

A stochastic gravitational wave (GW) background sources a shear in the flow of cosmic fluid which, through non-linear mode coupling, generates large-scale white noise (LSWN) in the kurvature density field. Building on the LSWN framework of our previous work, we derive the amplitude of this GW-induced LSWN and translate the observational non-detection of LSWN into bounds on the production redshift and density of gravity waves. In particular, a minimal constraint on gravity waves with $z=0$ density parameter $Ω_\mathrm{GW0}^*$ in frequency band $f_*$ generated at redshift $z_*$ must satisfy ${z_*}^2\,Ω_\mathrm{GW0}^*<5\times10^7\,(f_*/\mathrm{nHz})^{3/2}$. This, for example, precludes the gravity waves recently detected by pulsar timing arrays \cite{NANOGrav:2023hvm} from being present before $z_*\sim10^8$, long after the quark hadron phase transition. While orders of magnitude stronger than other constraints on gravity waves, this is a minimal LSWN constraint as realistic modeling of early universe gravity wave production, including the granularity of the gravity-wave sources and the LSWN produced by the associated acoustic waves would probably tighten this constraint by orders of magnitude.

Barenboim, Gabriela [Valencia U., IFIC; Valencia U↗

An improved understanding of the natural resonances of moonpools contained within floating rigid-bodies: Theory and application to oscillating water column devices

The fundamental interactions between waves, a floating rigid-body, and a moonpool that is selectively open to atmosphere or enclosed to purposefully induce pressure fluctuations are investigated. The moonpool hydrodynamic characteristics and the hydrodynamic coupling to the rigid-body are derived implicitly through reciprocity relations on an array of field points. By modeling the free surface of the moonpool in this manner, an explicit hydrodynamic coupling term is included in the equations of motion. This coupling results in the migration of the moonpool's natural resonance frequency from the piston frequency to a new frequency when enclosed in a floating rigid-body. Two geometries that highlight distinct aspects of marine vessels and oscillating water column (OWC) renewable energy devices are analyzed to reveal the coupled natural resonance migration. The power performance of these two OWCs in regular waves is also investigated. The air chamber is enclosed and a three-dimensional, linear, frequency domain performance model that links the rigid-body to the moonpool through a linear resistive control strategy is detailed. Furthermore, an analytic expression for the optimal linear resistive control values in regular waves is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A RECOLLIMATION SHOCK 80 mas FROM THE CORE IN THE JET OF THE RADIO GALAXY 3C 120: OBSERVATIONAL EVIDENCE AND MODELING

We present Very Long Baseline Array observations of the radio galaxy 3C 120 at 5, 8, 12, and 15 GHz designed to study a peculiar stationary jet feature (hereafter C80) located {approx}80 mas from the core, which was previously shown to display a brightness temperature {approx}600 times larger than expected at such distances. The high sensitivity of the images-obtained between 2009 December and 2010 June-has revealed that C80 corresponds to the eastern flux density peak of an arc of emission (hereafter A80), downstream of which extends a large ({approx}20 mas in size) bubble-like structure that resembles an inverted bow shock. The linearly polarized emission closely follows that of the total intensity in A80, with the electric vector position angle distributed nearly perpendicular to the arc-shaped structure. Despite the stationary nature of C80/A80, superluminal components with speeds up to 3 {+-} 1 c have been detected downstream from its position, resembling the behavior observed in the HST-1 emission complex in M87. The total and polarized emission of the C80/A80 structure, its lack of motion, and brightness temperature excess are best reproduced by a model based on synchrotron emission from a conical shock with cone opening angle {eta} = 10 Degree-Sign , jet viewing angle {theta} = 16 Degree-Sign , a completely tangled upstream magnetic field, and upstream Lorentz factor {gamma}{sub u} = 8.4. The good agreement between our observations and numerical modeling leads us to conclude that the peculiar feature associated with C80/A80 corresponds to a conical recollimation shock in the jet of 3C 120 located at a de-projected distance of {approx}190 pc downstream from the nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-TeP2-15: Feasibility Study of Fiber-Optic Cerenkov Radiation Sensors for in Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

Purpose: To evaluate the possibility of a fiber-optic Cerenkov radiation sensor (FCRS) for in vivo dose verification in proton therapy. Methods: The Cerenkov radiation due to the proton beam was measured using a homemade phantom, consisting of a plastic optical fiber (POF, PGSCD1001-13-E, Toray, Tokyo, Japan) connected to each channel of a multianode photomultiplier tube (MAPMT:H7546, Hamamatsu Photonics, Shizuoka, Japan). Data were acquired using a multi-anode photomultiplier tube with the NI-DAQ system (National Instruments Texas, USA). The real-time monitoring graphic user interface was programmed using Labview. The FCRS was analyzed for its dosimetrics characteristic in proton beam. To determine the accuracy of the FCRS in proton dose measurements, we compared the ionization chamber dose measurements using a water phantom. We investigated the feasibility of the FCRS for the measurement of dose distributions near the superficial region for proton plans with a varying separation between the target volume and the surface of 3 patients using a humanoid phantom. Results: The dose-response has good linearity. Dose-rate and energy dependence were found to be within 1%. Depth-dose distributions in non-modulated proton beams obtained with the FCRS was in good agreement with the depth-dose measurements from the ionization chamber. To evaluate the dosimetric accuracy of the FCRS, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the FCRS was within 3%. With in vivo dosimetry using the humanoid phantom, the calculated surface doses overestimated measurements by 4%–8% using FCRS. Conclusion: In previous study, our results indicate that the performance of the array-type FCRS was comparable to that of the currently used a multi-layer ion chamber system. In this study, we also believe that the fiber-optic Cerenkov radiation sensor has considerable potential for use with in vivo patient proton dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Refine your search to explore more results.