Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Intelligent Gate Drive for Fast Switching and Crosstalk Suppression of SiC Devices

This study presents an intelligent gate drive for silicon carbide (SiC) devices to fully utilize their potential of high switching-speed capability in a phase-leg configuration. Based on the SiC device's intrinsic properties, a gate assist circuit consisting of two auxiliary transistors with two diodes is introduced to actively control gate voltages and gate loop impedances of both devices in a phase-leg configuration during different switching transients. Compared to conventional gate drives, the proposed circuit has the capability of accelerating the switching speed of the phase-leg power devices and suppressing the crosstalk to below device limits. Based on Wolfspeed 1200-V SiC MOSFETs, the test results demonstrate the effectiveness of this intelligent gate drive under varying operating conditions. More importantly, the proposed intelligent gate assist circuitry is embedded into a gate drive integrated circuit, offering a simple, compact, and reliable solution for end-users to maximize benefits of SiC devices in actual power electronics applications.

30 DIRECT ENERGY CONVERSION↗

Applying the ATOM drug discovery platform to small-molecule antivirals (Annual Report)

The objective of this project is to advance our understanding of the ML approaches needed to find the most potent inhibitor through an AI guided search that simultaneously optimizes for limited off-target safety activity and desirable pharmacokinetics (PK) properties. The methods will be tested for inhibiting SARS-CoV-2 activity through inhibition of the main protease as a demonstration, but the methodology will be developed to apply to any biothreat target using a small-molecule protein binding-based intervention, with limited experimental data. Computational experiments are conducted using our ATOM generative molecular design (GMD) loop software, which is the implementation of our AI/ML drug design pipeline.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

How to sustain a CO 2 -thermosiphon in a partially saturated geothermal reservoir: Lessons learned from field experiment and numerical modeling

CO 2 has been proposed as a working fluid for geothermal energy production because of its ability to establish a self-sustaining CO 2 thermosiphon, taking advantage of the strong temperature dependence of CO 2 density. To test the concept of CO 2 heat extraction, in January 2015 a CO 2 thermosiphon was operated at the SECARB Cranfield Site, Cranfield, Mississippi, where a brine-saturated sand at a depth of 3.2 km has been under near continuous CO 2 flood since December 2009 as part of a U.S. Department of Energy demonstration of CO 2 sequestration, resulting in a partially saturated reservoir surrounding a well pair. The lateral distance between the producer and injector was 112 m at reservoir depth, a distance considered pre-commercial in scale, but great enough that thermal breakthrough was still not significant after several years of injection. Instead of producing power with a turbine, heat was extracted heat from recirculated fluid using a heat exchanger and portable chiller. The well field and surface equipment were instrumented to compare field observations with predicted responses from numerical models. Thermosiphon flow could be initiated by venting, but thereafter flow rate steadily declined, indicating that the thermosiphon was not sustainable. To model the system, the capability of T2Well, a fully coupled wellbore/reservoir numerical simulator, was expanded to enable simulation of the entire loop of fluid circulation in the fully-coupled system consisting of the injection/production wells, the reservoir, and the surface devices (heat exchanger, flow-rate regulator etc.). Combined with the newly developed TOUGH2 equation of state module called EOS7CMA, the enhanced T2 Well was used prior to the field experiment to simulate the circulation of a CO 2 -H 2 O-CH 4 mixture in a model geothermal system patterned after the Cranfield demonstration test. The model predicted that a sustainable thermosiphon could be achieved. After the field thermosiphon did not achieve the pre-test prediction of flow rates and thermosiphon sustainability, the numerical model was modified to improve realism and calibrate certain processes; it was then able to reproduce the major phenomena observed in the field. In a series of sensitivity studies, many factors were found that could potentially contribute to the failing of a sustainable thermosiphon. These factors could be categorized as two types: factors that increase the resistance to flow and factors that increase heat loss of the working fluid. In conclusion, the lessons learned can be applied to both future modeling and to achieving CO 2 -based geothermal reservoir exploitation.

15 GEOTHERMAL ENERGY↗

Off-axis neutral beam current drive for advanced scenario development in DIII-D

Modification of the two existing DIII-D neutral beamlines is planned to allow vertical steering to provide off-axis neutral beam current drive (NBCD) peaked as far off-axis as half the plasma minor radius. New calculations for a downward-steered beam indicate strong current drive with good localization off-axis so long as the toroidal magnetic field, B-T, and the plasma current, I-p, point in the same direction. This is due to good alignment of neutral beam injection (NBI) with the local pitch of the magnetic field lines. This model has been tested experimentally on DIII-D by injecting equatorially mounted NBs into reduced size plasmas that are vertically displaced with respect to the vessel midplane. The existence of off-axis NBCD is evident in the changes seen in sawtooth behaviour in the internal inductance. By shifting the plasma upwards or downwards, or by changing the sign of the toroidal field, off-axis NBCD profiles measured with motional Stark effect data and internal loop voltage show a difference in amplitude (40-45%) consistent with differences predicted by the changed NBI alignment with respect to the helicity of the magnetic field lines. The effects of NBI direction relative to field line helicity can be large even in ITER: off-axis NBCD can be increased by more than 30% if the B-T direction is reversed. Modification of the DIII-D NB system will strongly support scenario development for ITER and future tokamaks as well as provide flexible scientific tools for understanding transport, energetic particles and heating and current drive.

Murakami, Masanori↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Walmart Experimental Store Performance Stories: Preprint

Walmart opened two experimental stores--one in Colorado and one in Texas--in 2005 to serve as test beds for several advanced building systems. Each embodied more than 50 experiments covering materials, water systems, energy systems, and renewable energy production. Walmart worked for three years with the National Renewable Energy Laboratory for the Colorado Store and Oak Ridge National Laboratoryfor the Texas store to monitor, analyze, and report on their performance. HVAC experiments included waste oil boilers, a microturbine/absorption chiller combined heat and power system, evaporative cooling, and a transpired solar collector. The refrigeration systems integrated a medium-temperature secondary loop, evaporatively cooled condenser, doors on medium-temperature cases, andlight-emitting diodes on cases. Experiments in the lighting systems included a redesigned roof for clerestory daylighting and T-5 fluorescent lamps. Three photovoltaic systems for a total of 135 kW and a 50-kW wind turbine are also included. The energy system performance was compared to the measured performance of a prototypical Walmart store and to other benchmarks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and construction of a water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory

In this paper, a liquid water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory (NSCL) was designed and constructed as the initial step in proof-of-principle experiments to harvest useful radioisotopes from the Facility for Rare Isotope Beams (FRIB). FRIB will be a new national user facility for nuclear science, to be completed in 2020, at which radioisotopes will be collected synergistically from the water in cooling-loops for the primary beam dump that cycle the water at flow rates in excess of hundreds of gallons per minute. As part of the development of radiochemical expertise required to harvest long-lived radioisotopes of interest in this environment, the water target system described here was constructed and successfully used to collect a test beam of relativistic 24 Na ions produced at the NSCL. Finally, future studies will involve collecting interesting transition metal isotopes such as 67 Cu from less purified secondary projectile fragment beams.

07 ISOTOPE AND RADIATION SOURCES↗

Closed-Loop Error Learning Control for Uncertain Nonlinear Systems With Experimental Validation on a Mobile Robot

This article develops a closed-loop error learning control (CLELC) algorithm for feedback linearizable systems with experimental validation on a mobile robot. Traditional feedback and feedforward controllers are designed based on the nominal model by using the feedback linearization control (FLC) method. Then, an intelligent controller is designed based on the sliding mode learning algorithm that utilizes closed-loop error dynamics to learn the system behavior. The controllers are working in parallel, and the intelligent controller can gradually replace the feedback controller from the control of the system. In addition to the stability of the sliding mode learning algorithm, the closed-loop stability of an nth-order feedback linearizable system is proven. The simulation results demonstrate that the CLELC algorithm can improve control performance (e.g., smaller rise time, settling time, and overshoot) in the absence of uncertainties, and also provides robust control performance in the presence of uncertainties as compared to traditional FLC method. To test the efficiency and efficacy of the CLELC algorithm, the trajectory tracking problem of a tracked mobile robot is studied in real time. The experimental results demonstrate that the CLELC algorithm ensures highly accurate trajectory tracking performance than traditional FLC method.

97 MATHEMATICS AND COMPUTING↗

Effect of Hydrogen on Steady-State and Transient Combustion Instability Characteristics

This paper examines the effects of steady-state and transient hydrogen enrichment on thermoacoustic instability in a model gas turbine combustor. Combustion instability, a feedback loop between flame heat release rate oscillations and combustor acoustics, is characterized in a swirl-stabilized flame operated at a range of hydrogen–natural gas fuel blends and heat rates. Measurements of combustor chamber pressure fluctuations and CH* chemiluminescence imaging are used to characterize instability at a range of operating conditions. Steady-state tests show that both mixture heat rate and hydrogen content affect system stability. At a given heat rate, higher levels of hydrogen result in unstable combustion. As heat rate increases, instability occurs at lower concentrations of hydrogen in the fuel. Transient operation was tested in two directions—instability onset and decay—and two hydrogen-addition times—a short time of 1 ms and a longer time of 4 s. Results show that instability onset processes, through the transient addition of hydrogen, are highly repeatable regardless of the timescale of hydrogen addition. Certain instability decay processes are less repeatable, resulting in cases that do not fully transition from unstable to stable combustion despite similar changes in hydrogen fuel flow rate. Flame behavior before, during, and after the transient is characterized using high-speed CH* chemiluminescence imaging. Analysis of the high-speed images shows changes in flame stabilization and dynamics during the onset and decay processes. Finally, the results of this study can have implications for systems that experience variations in fuel composition, particularly in light of growing interest in hydrogen as a renewable fuel.

42 ENGINEERING↗

R&D ERL: 5 Cell 704 MHz SRF Cavity

One of the key components for the superconducting RF Energy Recovery Linac, (ERL) under development in the Collider Accelerator Department at Brookhaven National Laboratory, is the Linac cavity and cryomodule. The cavity is a 5 cell accelerating cavity designed to operate at 703.75 MHz, and to accelerate 2 MeV electrons from the photoinjector up to 15-20 MeV, allow them to make a single pass around the ERL loop and then decelerate them back down to 2 MeV prior to sending them to the beam dump. This cavity was designed by Rama Calaga and Ilan Ben-Zvi at BNL and fabricated by Advanced Energy Systems in Medford, NY. The cavity was then delivered to Thomas Jefferson Laboratory in VA for chemical processing, testing and assembly of the hermetic string assembly suitable for shipment back to BNL. Once at BNL it was built into a complete cryomodule, installed in the ERL test facility and commissioned. This paper will review the key components of the cavity and cryomodule and discuss the present status of the cryomodule commissioning. The BNL 5 cell accelerating cavity has been designed for use in our high average current Energy Recovery Linac, a proof of principle machine to demonstrate key components necessary for the future upgrades to RHIC as well as applications for future ampere class high current, high brightness ERL programs. The cavity has been tested at greater than 20 MV/m with a Q{sub 0} of 1e{sup 10}, meeting the design specifications for use at full energy in the ERL. This paper will review the cavity design and specifications as well as the RF measurements that have been made both in the VTA at Jefferson Lab as well as during the commissioning in the ERL test cave at BNL. Finally the future plan for cavity testing and measurements prior to its use in ERL operations will be reviewed. The general physics parameters for the cavity can be found in table 1, and the reader is referred to Rama Calaga's Thesis for a much more detailed review of the cavity geometry and design. There are several different parameters that make this cavity design very unique. The first is the 17 cm diameter cavity iris and 24 cm diameter beampipe. The geometry, along with the cavity design, results in a cavity with no trapped higher order modes, and a BBU threshold is > 2 amperes. Another feature of the geometry of this particular cavity is the fact that the lowest mechanical resonance is at {approx}200 Hz, thus making it much less susceptible to microphonics.

43 PARTICLE ACCELERATORS↗

Energy Recovery Linac: 5 Cell 704 MHz SRF Cavity

One of the key components for the superconducting RF Energy Recovery Linac, (ERL) under development in the Collider Accelerator Department at Brookhaven National Laboratory, is the Linac cavity and cryomodule. The cavity is a 5 cell accelerating cavity designed to operate at 703.75 MHz, and to accelerate 2 MeV electrons from the photoinjector up to 15-20 MeV, allow them to make a single pass around the ERL loop and then decelerate them back down to 2 MeV prior to sending them to the beam dump. This cavity was designed by Rama Calaga and Ilan Ben-Zvi at BNL and fabricated by Advanced Energy Systems in Medford, NY. The cavity was then delivered to Thomas Jefferson Laboratory in VA for chemical processing, testing and assembly of the hermetic string assembly suitable for shipment back to BNL. Once at BNL it was built into a complete cryomodule, installed in the ERL test facility and commissioned. This paper will review the key components of the cavity and cryomodule and discuss the present status of the cryomodule commissioning.

43 PARTICLE ACCELERATORS↗

Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems

The project “Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems” was conducted jointly by Westinghouse Electric Company (Westinghouse) and Argonne National Laboratory (ANL), over the period October 1, 2013- March 31, 2016. The project’s motivation was the need to provide designers of Sodium Fast Reactors (SFRs) with a validated, state-of-the-art computational tool for the prediction of sodium oxide (Na 2 O) deposition in small-diameter sodium heat exchanger (HX) channels, such as those in the diffusion bonded HXs proposed for SFRs coupled with a supercritical CO 2 (sCO 2 ) Brayton cycle power conversion system. In SFRs, Na 2 O deposition can potentially occur following accidental air ingress in the intermediate heat transport system (IHTS) sodium and simultaneous failure of the IHTS sodium cold trap. In this scenario, oxygen can travel through the IHTS loop and reach the coldest regions, represented by the cold end of the sodium channels of the HXs, where Na 2 O precipitation may initiate and continue. In addition to deteriorating HX heat transfer and pressure drop performance, Na 2 O deposition can lead to channel plugging especially when the size of the sodium channels is small, which is the case for diffusion bonded HXs whose sodium channel hydraulic diameter is generally below 5 mm. Sodium oxide melts at a high temperature well above the sodium melting temperature such that removal of a solid plug such as through dissolution by pure sodium could take a lengthy time. The Sodium Plugging Phenomena Loop (SPPL) was developed at ANL, prior to this project, for investigating Na 2 O deposition phenomena within sodium channels that are prototypical of the diffusion bonded HX channels envisioned for SFR-sCO 2 systems. In this project, a Computational Fluid Dynamic (CFD) model capable of simulating the thermal-hydraulics of the SPPL test section and provided with Na 2 O deposition prediction capabilities, was developed. This state-of-the-art computational tool incorporates a first-principles Na 2 O deposition model developed by ANL, and combines it with predictive capabilities for the spatial and temporal variation of temperature, velocity, dissolved oxygen concentration, and wall temperature under flowing sodium conditions. The CFD model was validated under no-deposition conditions using experimental data collected with the SPPL, demonstrating the model’s capability to predict the thermal-hydraulics of the SPPL test section within the measurement uncertainty characterizing the SPPL instrumentation. The model’s deposition prediction capability was not, however, validated as the SPPL could not be operated under plugging conditions during the project, resulting in the lack of deposition data with adequate pedigree for a CFD model validation. Two novel diagnostic techniques to detect and characterize Na 2 O deposits, i.e. Ultrasonic Time Domain Reflectometry (UTDR) and Potential Drop (PD) techniques, were developed to ultimately assist in the validation effort under plugging conditions, which can be performed once the SPPL becomes operational. This development effort consisted first in demonstrating, analytically and/or computationally, the capability of these techniques to diagnose Na 2 O deposits inside of small channels (particularly the deposit’s thickness), and subsequently in the fabrication and testing of prototypical UTDR and PD instrumentation. The testing, performed on mockups of the SPPL test section, demonstrated the capability of these techniques to detect and characterize material discontinuities like those induced by sodium oxide deposition on stainless steel channel walls. Because of the mentioned impossibility to run the SPPL in a plugging mode, the developed instrumentation could not be tested in-situ, i.e. at the SPPL while deposits are being formed inside of the SPPL test section. Recommended future work includes a possible enhancement in the CFD modeling technique and installation of the developed UTDR and PD instrumentation on the test section, followed by plugging tests to be conducted with the SPPL. The installation of the UTDR and PD diagnostic instrumentation on the SPPL test section will allow collection of Na 2 O deposition data after the onset of deposition to nearly complete channel plugging, which can ultimately be used for the validation of the CFD model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Provision of Grid Services by PV Plants with Integrated Battery Energy Storage System: Preprint

Battery energy storage systems (BESS), due to their tremendous range of uses and configurations, may assist PV integration in any number of ways by increasing power system flexibility. In this paper we describe results of a research project conducted by NREL and First Solar for developing controls and demonstrating many use cases for PV-BESS systems including (1) matching generation to loads through time shifting, reducing PV curtailment,; (2) promoting higher levels of PV penetrations by balancing the grid through ancillary services; (3) use of PV-BESS systems to provide wide-area stability services in the form of oscillations damping controls; and (r) use of gird forming BESS for enabling black start and islanded applications for PV-BESS systems. In the paper we will also describe the unique multi-MW test and validation platform developed at NREL for conducting research on fielded utility-scale PV-BESS systems. The platform consists of First Solar 0.43 MW PV power plant, NREL’s 1MW/1MW BESS, 2MW PV power supplies and 7MVA power electronic grid simulator interfaced with industrial plant controllers and power-hardware-in-the-loop (PHIL) capability.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Model-based, in-situ, non-destructive qualification and certification of parts made by autonomous additive manufacturing

To address the significant productivity challenges associated with the qualification and certification (Q&C) tasks of additively manufactured (AM) parts, which have traditionally relied on rigorous post‐build inspection and testing, we propose an integrated framework that combines model‐based qualification and certification (MBQ&C) with autonomous additive manufacturing (AAM). MBQ&C employs high‐fidelity predictive models, developed within the Integrated Computational Materials Engineering (ICME) paradigm, to simulate process–structure–property–performance relationships for assessing a part’s fitness for use. Since predictive models are commonly machine learning (ML)-based or reduced-order surrogates of validated physics models, they run efficiently, enabling timely inference. In parallel, the self-driving AAM utilises ML-based adaptive, closed‐loop control strategies to avoid, mitigate, or repair defects and anomalies during fabrication, thereby increasing the likelihood of producing acceptable parts. A key feature of the combined AAM-MBQ&C framework is that predictive models explicitly incorporate defects or anomalies that persist after the build, using instance-specific data captured via in-situ sensing. This customisation enables a build‐specific assessment of fitness for use, rather than relying on nominal or generic parameters. Such individualised evaluation provides a robust basis for Q&C-related acceptance decisions relating to each build. Additionally, the rapid solution capabilities of ML or reduced-order models enable the determination of a part’s suitability for service shortly after build completion. As the framework matures, it has the potential to substantially reduce reliance on conventional point‐design approaches—such as time‐consuming post‐build computed tomography scanning and costly destructive testing. Thus, the AAM-MBQ&C framework represents a transformative, scalable strategy for quality assurance of AM components, as parts produced within a stable, validated, and certified envelope can be certified with reduced testing. Key benefits include: (1) significant gains in Q&C productivity through efficient, model-centric assessment; (2) performance-based classification of defects into critical and non-critical categories; (3) the ability to predict potential deviations in the performance of parts affected by real-time, adaptive process control interventions relative to those produced under a certified process, and (4) the enabling of virtual Q&C for service environments that are difficult, hazardous, or impractical to access or reproduce experimentally. Collectively, these capabilities strengthen the business case for AM, particularly for high‐consequence and mission‐critical applications. Finally, although this work focuses on powder-based AM, the proposed techniques could be extended to AM processes employing alternative feedstock forms.

Gunasegaram, Dayalan↗

Effect of Irradiation Mode on Irradiated Microstructure of HT9

Core components in Generation IV fast reactors are expected to be exposed to very high damage levels of 200 displacements per atom (dpa) and above. Numerous issues with in-reactor irradiations including residual radioactivity, expense, length of irradiation and availability have led to increased interest in ion irradiation as a surrogate. Self-ion irradiations can produce damage rates of around 10{sup -3} dpa/s with well-controlled temperature, doses and dose rates, allowing for accelerated irradiation testing. Along with these benefits, ion irradiations have been shown to reproduce many of the same irradiation-induced features as in reactor irradiations. Of particular interest at high doses is formation of voids, precipitates and evolution of the dislocation microstructure. However, the beam mode under ion irradiation must be addressed. Raster scanning has been shown to produce microstructural features similar to those observed in-reactor irradiations, however, since they are a pulsed type irradiation, they may induce artifacts as a result of annealing between pulses. Defocused beams have the benefit of full coverage 100% of the time, but may be challenging in terms of ensuring even irradiation over a large area as well as in reaching high enough currents to maintain acceptable damage rates to be useful as a surrogate. This paper reports upon the comparison of behavior of ferritic martensitic steels under a raster scanned or defocused beam mode. The objective is to determine the effect of beam condition the irradiated microstructural; specifically, on the formation of voids, precipitates and dislocation loops and analyze these results within the context of the FDRT model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System design of a 1 MW north-facing, solid particle receiver

Falling solid particle receivers (SPR) utilize small particles as a heat collecting medium within a cavity receiver structure. The components required to operate an SPR include the receiver (to heat the particles), bottom hopper (to catch the falling particles), particle lift elevator (to lift particles back to the top of the receiver), top hopper (to store particles before being dropped through the receiver), and ducting. In addition to the required components, there are additional features needed for an experimental system. These features include: a support structure to house all components, calibration panel to measure incident radiation, cooling loops, and sensors (flux gages, thermocouples, pressure gages). Each of these components had to be designed to withstand temperatures ranging from ambient to 700 °C. Thermal stresses from thermal expansion become a key factor in these types of high temperature systems. The SPR will be housing ~3000 kg of solid particles. The final system will be tested at the National Solar Thermal Test Facility in Albuquerque, NM.

14 SOLAR ENERGY↗

Refine your search to explore more results.